HEAT CONTROLLER AS-Q093E7Y0, AS-Q123E7Y0 Wall Mounted Mini Split System Inverter Single Zone Air Conditioning Instruction Manual

August 13, 2024
Heat Controller

HEAT CONTROLLER AS-Q093E7Y0, AS-Q123E7Y0 Wall Mounted Mini Split System Inverter Single Zone Air Conditioning Instruction Manual

CAUTION
Before servicing the unit, read the “safety precautions” in this manual.

Only for authorised service personnel.

Specification

Models| AS-Q093E7Y0 [VMC09SB-1]| AS-Q123E7Y0 [VMC12SB-1]
---|---|---
Cooling Capacity(Min~Rating~Max)| kW| 0.90~2.70~3.70| 0.90~3.52~4.04
Btu/h| 3,070~9,200~12,620| 3,070~12,000~13,800
Heating Capacity(Min~Rating~Max)| kW| –| –
Btu/h| –| –
Power Input| Cooling/Heating| W| 690/-| 1120/-
Running Current| Cooling/Heating| A| 3.2/-| 5.0/-
Starting Current| Cooling/Heating| A| 3.2/-| 5.0/-
EER| W/W| 3.91| 3.14
Btu/h.W| 13.3| 10.7
COP| W/W| –| –
Power Supply| Ø / V / Hz| 1/208-230/60| 1/208-230/60
Power Factor| %| 94| 97
Air Flow Rate| Indoor,Max| m3/min(cfm)| 8.5(300)| 9.5(335)
Outdoor,Max| m3/min(cfm)| 29(1,024)| 29(1,024)
Moisture Removal| l/h| 0.6| 1.3
Sound Level| Indoor,H/M/L| dB(A)+3| 36/33/30| 39/33/30
Outdoor,Max| dB(A)+3| 48| 48
Refrigerant & Charge(at 7.5m)| g(oz)| R410A, 1,000(35.3)| R410A,1,000(35.3)
Additional Refrigerant Charge| g/m(oz/ft)| 20(0.22)| 20(0.22)
Compressor| Type| Rotary| | Rotary|
Model| 5RS102XAA21| | 5RS102XAA21|
Motor Type| BLDC| | BLDC|
Oil Type| FV50S| | FV50S|
Oil Charge| cc| 320| | 320|
O.L.P Name| –| | –|
Fan(Indoor)| Type| Cross Flow Fan| Cross Flow Fan
Motor Output| W| 20| 20
Fan(outdoor)| Type| Propeller| Propeller
Motor Type| BLDC| BLDC
Motor Output| W| 43| 43
Circuit Breaker| A| 15| 15
Power Supply Cable| AWG| 14| 14
Power and Transmission Cable| AWG| 18| 18
Piping Connections| Liquid Side| mm(in)| 6.35(1/4)| 6.35(1/4)
Gas Side| mm(in)| 9.52(3/8)| 9.52(3/8)
Drain Hose| O.D , I.D| mm(in)| 21.5,16.0(0.85,0.63)| 21.5,16.0(0.85,0.63)
Dimension| Indoor(W
HD)| mm| 895282165| 895282165
inch| 35.2
11.16.5| 35.211.16.5
Outdoor(W
HD)| mm| 770545245| 770545245
inch| 30.3
21.59.6| 30.321.5*9.6
Net Weight| Indoor| kg(lbs)| 8(17.6)| 8(17.6)
Outdoor| kg(lbs)| 35(77.2)| 35(77.2)
Operation Range| Cooling(Outdoor)| °C(°F)| -10 ~ 46 (14.0~114.8)(Low Ambient)| -10 ~ 46 (14.0~114.8)(Low Ambient)
Heating(Outdoor)| °C(°F)| –| –
Max. Piping Length| m(ft)| 15(49)| 15(49)
Max. Elevation Difference| m(ft)| 7(23)| 7(23)
Tool Code(Chassis)| Indoor + Outdoor| SE + UL| SE + UL
Functions| Temperature Control| Thermistor| Thermistor
Plasma Filter| –| –
Prefilter(washable/anti-fungus)| O| O
Auto Clean| O| O
CHAOS Wind(Auto Wind)| O| O
Steps, Fan/Cool/Heat| -/4/-| -/4/-
Airflow Direction Control(up&down)| Auto| Auto
Airflow Direction Control(left&right)| Manual| Manual
Remocon Type| Wireless LCD| Wireless LCD
Setting Temperature Range| Cooling [°C(°F)]| 18 ~ 30 (64~86)| 18 ~ 30 (64~86)
Heating [°C(°F)]| –| –
Auto Operation (Mi com Control)| –| –
Auto Changeover (Mi com Control)| –| –
Self Diagnosis| O| O
Timer| 24h On/Off| 24h On/Off
Sleep Operation| O| O
Soft Dry Operation| O| O
Restart Delay(minute)| 2| 2
Deice Control(Defrost)| –| –
Hot Start| –| –
Jet Cool / Heat| O / –| O / –
Low Ambient Operation| O| O
Special Function| –| –
Network Functions| Dry Contact| –| –
Network Solution(LGAP)| –| –
PI485| –| –

Note:
O : Applied, – : No relation

  • For circuit breaker rating, please conform to local standards wherever necessary.
    ❈ Some of functions are slightly different depending upon models.
    ❈ The specification may be subject to change without prior notice for purpose of improvement.
    Capacity : based on 203V

Piping Diagrams

LOC. Description PCB Connector
Th1 Thermistor for indoor air temperature CN_TH1(INDOOR)
Th2 Thermistor for evaporating temperature
Th3 Thermistor for discharge pipe temperature CN_D_PIPE(Outdoor)
Th4 Thermistor for condensing temperature CN_TH1(OUTDOOR)
Th5 Thermistor for outdoor air temperature
  • EEV : Electronic Expansion Valve.

Wiring Diagrams

**Indoor Unit

**

**Outdoor Unit

**

Exploded View

Indoor Unit

Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer’s request. Please check the correct parts in View RPL(Replacement Part List) on GCSC. (GCSC Website http://biz.Lgservice.com,)

**Outdoor Unit

**

Specifications and performance data subject to change without notice.
HEAT CONTROLLER, INC.
1900 WELL WORTH AVENUE • JACKSON, MICHIGAN 49203
THE QUALITY LEADER IN CONDITIONING AIR