Specifications:
- Model: HEAT CONTROLLER AS-Q123E7Y0
- Cooling Capacity: 0.90~3.52~4.04 kW (3,070~12,000~13,800 Btu/h)
- Heating Capacity: 0.90~3.52~4.04 kW (3,070~12,000~13,800 Btu/h)
- Power Input: 1120 W
- Running Current: 5.0 A
- Starting Current: 5.0 A
- EER: 3.14
- Power Supply: 1/208-230V/60Hz
- Fan Type: Cross Flow Fan (Indoor), Propeller Fan (Outdoor)
- Refrigerant: R410A
- Net Weight: 35 kg (77.2 lbs)
- Operation Range: -10°C to 46°C (14.0°F to 114.8°F)
Product Usage Instructions
Safety Precautions:
Before servicing the unit, read the safety precautions in the manual. Only
authorized service personnel should perform maintenance.
Installation:
Follow the provided piping diagrams for proper installation of the indoor and
outdoor units.
Operation:
Ensure proper power supply and cable connections before starting the unit. Use
the wireless LCD remote control for convenient operation.
Maintenance:
Regularly clean the filters and ensure proper drainage by checking the drain
hose. Refer to the manual for detailed maintenance instructions.
This Owner’s Manual is provided and hosted by Appliance Factory Parts.
Model: AS-Q093E7Y0 [VMC09SB-1] AS-Q123E7YO [VMC12SB-1]
HEAT CONTROLLER
AS-Q123E7Y0
Owner’s Manual
Shop genuine replacement parts for HEAT CONTROLLER AS-Q123E7Y0
Find Your HEAT CONTROLLER Air Conditioner Parts – Select From 32 Models
CAUTION
Before servicing the unit, read the “safety precautions” in this manual.
Only for authorized service personnel.
Specification
Models| AS-Q093E7Y0 [VMC09SB-1]| AS-Q123E7Y0
[VMC12SB-1]
---|---|---
Cooling Capacity
(Min~Rating~Max)
| kW| 0.90~2.70~3.70| 0.90~3.52~4.04
Btu/h| 3,070~9,200~12,620| 3,070~12,000~13,800
Heating Capacity
(Min~Rating~Max)
| kW| –| –
Btu/h| –| –
Power Input| Cooling/Heating| W| 690/-| 1120/-
Running Current| Cooling/Heating| A| 3.2/-| 5.0/-
Starting Current| Cooling/Heating| A| 3.2/-| 5.0/-
EER| W/W| 3.91| 3.14
Btu/h.W| 13.3| 10.7
COP| W/W| –| –
Power Supply| Ø / V / Hz| 1/208-230/60| 1/208-230/60
Power Factor| %| 94| 97
Air Flow Rate| Indoor,Max| m3/min(cfm)| 8.5(300)| 9.5(335)
Outdoor,Max| m3/min(cfm)| 29(1,024)| 29(1,024)
Moisture Removal| l/h| 0.6| 1.3
Sound Level| Indoor,H/M/L| dB(A)+3| 36/33/30| 39/33/30
Outdoor,Max| dB(A)+3| 48| 48
Refrigerant & Charge(at 7.5m)| g(oz)| R410A, 1,000(35.3)| R410A,1,000(35.3)
Additional Refrigerant Charge| g/m(oz/ft)| 20(0.22)| 20(0.22)
Compressor| Type| Rotary| | Rotary|
Model| 5RS102XAA21| | 5RS102XAA21|
Motor Type| BLDC| | BLDC|
Oil Type| FV50S| | FV50S|
Oil Charge| cc| 320| | 320|
O.L.P Name| –| | –|
Fan(Indoor)| Type| Cross Flow Fan| Cross Flow Fan
Motor Output| W| 20| 20
Fan(outdoor)| Type| Propeller| Propeller
Motor Type| BLDC| BLDC
Motor Output| W| 43| 43
Circuit Breaker*| A| 15| 15
Power Supply Cable| AWG| 14| 14
Power and Transmission Cable| AWG| 18| 18
Piping
Connections
| Liquid Side| mm(in)| 6.35(1/4)| 6.35(1/4)
Gas Side| mm(in)| 9.52(3/8)| 9.52(3/8)
Drain Hose| O.D , I.D| mm(in)| 21.5,16.0(0.85,0.63)| 21.5,16.0(0.85,0.63)
Dimension| Indoor(WHD)| mm| 895282165| 895282165
inch| 35.211.16.5| 35.211.16.5
Outdoor(WHD)| mm| 770545245| 770545245
inch| 30.321.59.6| 30.321.59.6
Net Weight| Indoor| kg(lbs)| 8(17.6)| 8(17.6)
Outdoor| kg(lbs)| 35(77.2)| 35(77.2)
Operation Range| Cooling(Outdoor)| °C(°F)| -10 ~ 46 (14.0~114.8)(Low Ambient)|
-10 ~ 46 (14.0~114.8)(Low Ambient)
Heating(Outdoor)| °C(°F)| –| –
Max. Piping Length| m(ft)| 15(49)| 15(49)
Max. Elevation Difference| m(ft)| 7(23)| 7(23)
Tool Code(Chassis)| Indoor + Outdoor| SE + UL| SE + UL
Functions| Temperature Control| Thermistor| Thermistor
Plasma Filter| –| –
Prefilter(washable/anti-fungus)| O| O
Auto Clean| O| O
CHAOS Wind(Auto Wind)| O| O
Steps, Fan/Cool/Heat| -/4/-| -/4/-
Airflow Direction Control(up&down)| Auto| Auto
Airflow Direction Control(left&right)| Manual| Manual
Remocon Type| Wireless LCD| Wireless LCD
Setting Temperature
Range
| Cooling [°C(°F)]| 18 ~ 30 (64~86)| 18 ~ 30 (64~86)
Heating [°C(°F)]| –| –
Auto Operation (Micom Control)| –| –
Auto Changeover (Micom Control)| –| –
Self Diagnosis| O| O
Timer| 24h On/Off| 24h On/Off
Sleep Operation| O| O
Soft Dry Operation| O| O
Restart Delay(minute)| 2| 2
Deice Control(Defrost)| –| –
Hot Start| –| –
Jet Cool / Heat| O / –| O / –
Low Ambient Operation| O| O
Special Function| –| –
Network Functions| Dry Contact| –| –
Network Solution(LGAP)| –| –
PI485| –| –
Note:
O : Applied, – : No relation
For circuit breaker rating, please conform to local standards wherever necessary.
- Some of functions are slightly different depending upon models.
- The specification may be subject to change without prior notice for purpose of improvement.
- Capacity : based on 203V
Piping Diagrams
LOC. | Description | PCB Connector |
---|---|---|
Th1 | Thermistor for indoor air temperature | CN_TH1(INDOOR) |
Th2 | Thermistor for evaporating temperature | |
Th3 | Thermistor for discharge pipe temperature | CN_D_PIPE(Outdoor) |
Th4 | Thermistor for condensing temperature | CN_TH1(OUTDOOR) |
Th5 | Thermistor for outdoor air temperature |
EEV: Electronic Expansion Valve.
Wiring Diagrams
Indoor Unit
Outdoor Unit
Exploded View
Indoor Unit
Note) * Please ensure GCSC since the replacement parts may be changed
depending upon the buyer’s request.
Please check the correct parts in View RPL(Replacement Part List) on GCSC.
(GCSC Website http://biz.Lgservice.com,)
Outdoor Unit
Note) * Please ensure GCSC since the replacement parts may be changed
depending upon the buyer’s request.
Please check the correct parts in View RPL(Replacement Part List) on GCSC.
(GCSC Website http://biz.Lgservice.com,)
Frequently Asked Questions (FAQ)
Q: What should I do if the unit is not cooling/heating properly?
A: Check the air filters for blockages and ensure proper airflow. Also,
make sure the temperature settings are correct on the remote control.
Q: How often should I clean the filters?
A: It is recommended to clean the filters every 2-4 weeks depending on
usage to maintain optimal performance.
Q: Can I install the unit myself?
A: Installation should be done by a certified technician to ensure proper
setup and avoid any safety hazards.
Specifications and performance data subject to change without notice.
HEAT CONTROLLER, INC.
1900 WELLWORTH AVENUE • JACKSON, MICHIGAN 49203
THE QUALITY LEADER IN CONDITIONING AIR
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
References
- Repair Your Grill: Shop Replacement Parts for 24,880 Models
- Heat Controller Air Conditioner Parts - Select From 32 Models
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>