Step 1: Install the Backup Battery

  1. Secure the battery to the backside of the panel enclosure with the provided double-sided tape. Do not cover the tamper location. Refer to Figure 1.
  2. Remove the front cover of the panel enclosure and pull the battery wires through the wiring cutout.
  3. Connect the battery lead connector to the battery connection header on the panel. Refer to Figure 2.
  4. Replace the front cover of the panel enclosure after completing panel programming.

Step 2: Prepare the Backbox for Wiring
Drill out the desired conduit knockouts for routing wires to the panel. Secure the wires that exit the backbox.

Step 3: Wire the Panel
Route wires from the outside of the backbox through to the inside, then connect them to the panel. Ensure wires do not interfere with the tamper switch. Refer to the following sections for information about wiring the panel.

Caution : Ensure the power supply is not plugged into an outlet before wiring. Failure to do so may result in equipment damage or injury.

Install the Ethernet Cable

  1. Remove the tab on the back of the panel enclosure to make space for the Ethernet cable.
  2. Route the Ethernet cable through the space, then connect the Ethernet cable to the panel.

Install the Keypad
The 7060 Thinline Keypad, 699-W Deskstand, and Model 330-4 Wiring Harness with right angle connector are included in the TMSentry Kit and may also be ordered separately.

  1. Place the keypad on the deskstand and put it inside the ATM.
  2. Connect the right angle connector to the keypad wiring harness and then connect it to the keypad connection header on the panel. The black wire should be on top and the red wire should be on the bottom.
  3. Secure the wiring harness to the backbox.
  4. Program the keypad as a device in the TMSentry and program the keypad. Refer to the 7000 Series Installation and Programming Guide for more information.

Wire the Terminals
Observe polarity when wiring the power connection terminals. Refer to Figure 5 for terminal wiring information. Secure all terminal wires to the backbox with strain relief.

Step 4: Mount the TMSentry

  1. Secure the panel enclosure to the 685 Series Conduit Backbox using the four provided 1” #6 screws.
  2. Secure the assembled TMSentry to the inside of the ATM using the provided hook and loop strip.

Step 5: Install the Antenna

  1. Drill a 1/2” hole in the outside of the ATM (1) or use the existing knockout. It is recommended to install the antenna on the back near the top.
  2. Route the antenna wire through the drilled hole to the inside of the ATM (2).
  3. Secure the antenna puck to the outside of the ATM using the provided washers and nut (3).
  4. Place the antenna onto the SMA connector on the panel and twist until tightly secured (4). Secure the antenna to the backbox.

Designed, engineered, and manufactured in Springfield, MO using U.S. and global components.
LT-2871 24271

INTRUSION • FIRE • ACCESS • NETWORKS
2500 North Partnership Boulevard
Springfield, Missouri 65803-8877
Domestic : 800.641.4282 | International : 417.831.9362
DMP.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals