LOCINOX VENUS Motorised Gate Closer Instruction Manual

July 29, 2024
LOCINOX

LOCINOX VENUS Motorised Gate Closer

FCC statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including interference that may cause undesired operation.

CAUTION: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.
  • This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjuntion with any other antenna or transmitter.

COPYRIGHT
Copyright© 2023 Locinox. All rights reserved. This product incorporates copyright protected technology that is protected by a number of EU patent method claims and other intellectual property rights owned by the Locinox Corporation and other rightholders. Use of this copyright protected technology must be authorized by the Locinox Corporation. Reverse engineering or disassembly is prohibited. No part of this publication can either be reproduced, communicated, transcribed, stored in a retrieval system or be translated into any language in any form or by any means, whether electronic, mechanical, magnetic, optical, chemical, manual or otherwise, unless explicit written consent has been given by the copyright holder.

NOTICE
The contents of this publication are subject to change. The Locinox Corporation reserves the right to alter the contents of this publication at any time and without notice. The contents of this publication may contain inaccuracies or typographical errors and is supplied for informational use only.

TECHNICAL SUPPORT
If you require any additional information or assistance during the installation, please contact your dealer, who will be able to provide the latest information. Alternatively, you can visit the Locinox website for more technical information or e-mail us on info@locinox.com. Please keep the serial number at hand of your product for future support.

Safety and installation notices

  • Locinox declines all liability caused by improper use or use other than that for which the automated system was intended.
  • Do not install the equipment in an explosive atmosphere: the presence of inflammable gas or fumes is a serious danger to safety.
  • Connection to the power supply must be made by a professional electrician. Cut off the mains power supply before installation or maintenance interventions.
  • The safety of this equipment is only guaranteed when it is effectively earthed in conformity with current safety standards and regulations.
  • Respect the minimum cable sections for the power and signal cables.
  • Prepare suitable piping and ducts for routing the electrical cables, ensuring protection against mechanical damage.
  • The gate structure should be solid and suitable. If necessary, add suitable reinforcement at the anchoring points. The use of a steel gate post with a thickness of 3mm is recommended, minimum 2mm. Aluminum gate post requires a thickness of 5mm.
  • The hinges should be in good condition and greased, bearing hinges are recommended. The forces on the gate hinges can be high during fast and powerful gate movements. It is recommended to add a safety cable and oversize the gate hinges.
  • The gate should be placed level. Do not install on tilted gates.
  • The Venus operator arm should be installed on the top side. Do not install the product upside down.
  • Ensure there is a stop installed in the closed position. An opening stop is not mandatory, but recommended.
  • Guarantee sufficient distance between the moving gate and the gate post to avoid finger entrapment.
  • Venus can be configured using a mobile application via a Wi-Fi connection. To download the application, scan the QR code provided on the product or refer to the last step in the installation manual. Follow the app’s instructions to configure the motor.
  • Follow the current status of directives, standards and country-specific regulations.
  • Europe : EN16005 / US: ANSI 156.19
  • In compliance with Machine Directive 2006/42/ EC, a risk analysis must be performed and automated gate identified in accordance with CE Marking directive 93/68/EEC before the system is commissioned.

Product description

Models

  • VENUS-S:
    Reversible motor for pedestrian gates with integrated electronics including sliding arm

  • VENUS-A:
    Reversible motor for pedestrian gates with integrated electronics including articulated arm

  • VENUS-G:
    Reversible motor for pedestrian gates with integrated electronics, including compact arm for 180° hinges

Accessories

  • VENUS-ARM-S:
    Sliding arm for the Venus motor.

  • VENUS-ARM-A:
    Articulated arm for the Venus motor.

  • VENUS-ARM-G:
    Compact arm for the Venus motor.

  • VENUS-RAIL:
    Accessory for VENUS-S and VENUS-A in combination with 180° hinges.

  • VENUS-ADAPTERPLATE:
    Adapter plate for mounting on wall or 60 mm post.

Intended use
The Venus gate motor is designed for the automatic opening and closing of pedestrian swing gates and outdoor use. This is a reversible motor, so an (electric) lock is mandatory. The operating speed is limited to low-energy settings according EN16005 and ANSI 156.19 standards. Any improper use, as well as modifications to the products, is not permitted.

Technical specifications

  • Power supply (V) 110 – 240V AC (50/60Hz)
  • Motor voltage (V) 24V DC
  • Nominal power 50 W
  • Max motor torque (Nm) 150 Nm
  • Operating temperature range (°C) -30°C ÷ 70°C
  • Opening time to 90° (s) > 4 sec
  • Degree of protection IP 54
  • Weight excluding arm (kg) 6.1 kg

Connection scheme

Locinox’ installation app required for initialization and configuration

  1. 110-240V AC ±10% 50/60Hz
  2. 3 programmable outputs:
    • Electric lock (Fail Open / Fail Close)
    • Flashlight / light with timer
    • 24V DC AUX
    • Total output power: max 0.5A (12W)
  3. 3 programmable inputs:
    • Activation device (N.O.)
    • Safety device (N.C. / 8K2)

LOCINOX-VENUS-Motorised-Gate-Closer-fig-1

LOCINOX-VENUS-Motorised-Gate-Closer-fig-2

Doc. Nr.: P00017261
Locinox NV • Brabantstraat 107 • 8790 Waregem • Belgium
Locinox CEE• Irysowa 9 • 55-040 Bielany Wrocławskie • Poland
Locinox LLC • 460 Windy Point Drive • Glendale Heights – IL 60139 • USA

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals