LOCINOX 20240130 Venus Gate Motor User Manual

May 15, 2024
LOCINOX

LOCINOX 20240130 Venus Gate Motor

COPYRIGHT
Copyright© 2023 Locinox. All rights reserved. This product incorporates copyright-protected technology that is protected by some EU patent method claims and other intellectual property rights owned by the Locinox Corporation and other rightsholders. Use of this copyright-protected technology must be authorized by the Locinox Corporation. Reverse engineering or disassembly is prohibited. No part of this publication can either be reproduced, communicated, transcribed, stored in a retrieval system or be translated into any language in any form or by any means, whether electronic, mechanical, magnetic, optical, chemical, manual or otherwise, unless explicit written consent has been given by the copyright holder.

NOTICE
The contents of this publication are subject to change. The Locinox Corporation reserves the right to alter the contents of this publication at any time and without notice. The contents of this publication may contain inaccuracies or typographical errors and is supplied for informational use only.

TECHNICAL SUPPORT

If you require any additional information or assistance during the installation, please contact your dealer, who will be able to provide the latest information. Alternatively, you can visit the Locinox website for more technical information or e-mail us on [email protected]. Please keep the serial number at hand of your product for future support.

LOCINOX-20240130-Venus-Gate-Motor-FIG-1

Safety and installation notices

  • Locinox declines all liability caused by improper use or use other than that for which the automated system was intended.
  • Do not install the equipment in an explosive atmosphere: the presence of inflammable gas or fumes is a serious danger to safety.
  • Connection to the power supply must be made by a professional electrician. Cut off the mains power supply before installation or maintenance interventions.
  • The safety of this equipment is only guaranteed when it is effectively earthed in conformity with current safety standards and regulations.
  • Respect the minimum cable sections for the power and signal cables.
  • Prepare suitable piping and ducts for routing the electrical cables, ensuring protection against mechanical damage.
  • The gate structure should be solid and suitable. If necessary, add suitable reinforcement at the anchoring points. The use of a steel gate post with a thickness of 3mm is recommended.
  • The hinges should be in good condition and greased, bearing hinges are recommended.
  • The gate should be placed level. Do not install on tilted gates.
  • The Venus operator arm should be installed on the top side. Do not install the product upside down.
  • Ensure there is a stop installed in the closed position. An opening stop is not mandatory, but recommended.
  • Guarantee sufficient distance between the moving gate and the gate post to avoid finger entrapment.
  • Follow the current status of directives, standards and country-specific regulations.
  • Europe: EN16005 / US: ANSI 156.19
  • In compliance with Machine Directive 2006/42/EC, a risk analysis must be performed and automated gate identified in accordance with CE Marking directive 93/68/EEC before the system is commissioned.

Product Description

Models

VENUS-S:
Reversible motor for pedestrian gates with integrated electronics including sliding arm

VENUS-A:
Reversible motor for pedestrian gates with integrated electronics including articulated arm

Accessories

  • VENUS-ARM-S:
    Sliding arm for the Venus motor

  • VENUS-ARM-A:
    Articulated arm for the Venus motor

  • VENUS-RAIL:
    1.5m long rail to be cut to length, can be used in combination with 180° hinges

Intended use

The Venus gate motor is designed for the automatic opening and closing of pedestrian swing gates and outdoor use. This is a reversible motor, so an (electric) lock is mandatory. The operating speed is limited to low-energy settings according EN16005 and ANSI 156.19 standards. Any improper use, as well as modifications to the products, is not permitted.

Technical specifications

  • Power supply (V)
    • 110 – 240V AC (50/60Hz)
  • Motor voltage (V)
    • 24V DC
  • Nominal power
    • 30 W
  • Max power (W)
    • 150 W
  • Max motor torque (Nm)
    • 150 Nm
  • Operating temperature range (°C)
    • -30°C ÷ 70°C
  • Opening time to 90° (s)
    • 4 sec

  • Degree of protection
    • IP 54
  • Weight excluding arm (kg)
    • 6.1 kg

Connection scheme

‘Locinox’ installation app is required for initialization and configuration

  1. 110-240V AC ±10% 50/60Hz
  2. 3 programmable outputs:
    • Electric lock (Fail Open / Fail Close)
    • Flashlight/light with timer
    • 24V DC AUX Total output power: max 2A (48W)
  3. programmable inputs:
    • Activation device (N.O.)
    • Safety device (N.C. / 8K2)

HOW TO USE

LOCINOX-20240130-Venus-Gate-Motor-FIG-3 LOCINOX-20240130-Venus-Gate-Motor-FIG-37 LOCINOX-20240130-Venus-Gate-Motor-FIG-4 LOCINOX-20240130-Venus-Gate-Motor-FIG-25 LOCINOX-20240130-Venus-Gate-Motor-FIG-26 LOCINOX-20240130-Venus-Gate-Motor-FIG-27 LOCINOX-20240130-Venus-Gate-Motor-FIG-28 LOCINOX-20240130-Venus-Gate-Motor-FIG-29 LOCINOX-20240130-Venus-Gate-Motor-FIG-30Motor setup LOCINOX-20240130-Venus-Gate-Motor-FIG-32 LOCINOX-20240130-Venus-Gate-Motor-FIG-34 LOCINOX-20240130-Venus-Gate-Motor-FIG-35 LOCINOX-20240130-Venus-Gate-Motor-FIG-36