scs sentinel MBA0103 Articulated Arm Motor For Revolving Door Installation Guide
- July 22, 2024
- SCS sentinel
Table of Contents
- scs sentinel MBA0103 Articulated Arm Motor For Revolving Door
- INSTALLING THE MOTORISED SYSTEM
- ****MAINTENANCE AND UPKEEP OF THE MOTORISED DEVICE
- DESCRIPTION
- Dimensions
- WIRING/ INSTALLING
- Inside opening
- C5- Wiring diagram
- Inside opening
- C6- Installing
- SETTING/ USING
- D10 – System learning process simple gate
- E- TECHNICAL FEATURES
- F- MAINTENANCE
- Troubleshooting
- H-WARRANTY
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
scs sentinel MBA0103 Articulated Arm Motor For Revolving Door
SAFETY INSTRUCTIONS
WARNING: Important safety instructions. It is essential to follow these
instructions for reasons of personal safety, as incorrect installation may
result in serious injury. Keep these instructions in a safe place. If
installation is carried out by a third party, this manual must be given to
the end user. The end user must also be trained in the safe use of the
appliance in accordance with the instructions in this manual.
CD INFORMATION
SGS SENTINEL certifies that its motorised operators comply with the standards and safety regulations for motorised gate operators (EN 60335-2-103).
The use of this product outside the specified conditions or the use of components or accessories not recommended by SGS SENTINEL may compromise the safety of property and persons, and is therefore prohibited. SGS SENTINEL accepts no liability for any damage resulting from failure to comply with the instructions provided in this manual.
BEFORE INSTALLING
This product is only designed for the automation of a swing gate for
“residential” use.
Installation requires qualified staff with mechanical and electrical skills.
Before installing the motorised device, check that the driven part is in good
mechanical condition, properly balanced and opens and closes correctly.
Make sure that the temperature range indicated on the motorised system is
suitable for the installation’s location.
PLEASE NOTE: The motorised system cannot be used with a driven part
incorporating a side gate.
ELECTRICAL INSTALLATION
CAUTION: The power supply installation must comply with current standards
in the country where the product is installed (NF G 15-100 for France) and be
carried out by qualified staff.
The mains supply must be protected against overload by a suitable trip switch
and an earth leakage circuit breaker. A means of disconnecting all the poles
of the power supply network must be provided. This device must be connected
directly to the supply terminals and have a contact separation distance on all
poles to ensure complete disconnection in accordance with the installation
rules.
If the power cable is damaged, it must be replaced by the manufacturer, its
after-sales service or similarly qualified persons in order to avoid a hazard.
INSTALLING THE MOTORISED SYSTEM
CAUTION: The motorised device must be dis
UJ connected from its power source during installation.
WARNING: Make sure that in the installation environment (gate and fixed parts), the zones at risk are avoided or at least signposted (see “Potential risks” section after these instructions).
Ensure that crushing caused by the opening movement of the driven part is avoided between the driven part and the surrounding fixed parts.
WARNING: Activation of the manual disconnection device may cause uncontrolled movement of the driven part due to mechanical failure or loss of balance. If a fixed control device is installed (keypad, key selector, etc.), it must be installed 1.5 m above the ground, away from moving parts but always within sight of the gate.
- If the gate is to operate in automatic closing mode, or if it is to be opened remotely without a direct view of the gate, photocells must be installed without fail.
- If your gate closes automatically, or if it opens onto the public highway, it may be compulsory to install a flashing light, depending on the regulations in the country where the motorised device is installed.
- It is the installer’s responsibility to ensure that the installation is compliant.
- After installation, make sure that the mechanism is properly adjusted and that the protection system and any manual disconnection devices function properly. Permanently attach the label concerning the manual disconnection device to the operating element of this device.
USING THE MOTORISED SYSTEM
PLEASE NOTE : This appliance may be used by children at least 8 years old
and by people with reduced physical, sensory or mental capabilities or
without experience or knowledge, if they are properly supervised or
instructed in the safe use of the appliance, and if the risks involved have
been understood.
Children should not play with the appliance.
The user’s cleaning and maintenance must not be carried out by unsupervised
children.
Do not allow children to play with the unit or its controls. Keep remote
control units out of the reach of children.
WARNING: The user must supervise the gate during operation and keep people away until the gate is fully opened or closed. Do not deliberately hinder gate movement.
****MAINTENANCE AND UPKEEP OF THE MOTORISED DEVICE
CAUTION: The motorised device must be dis
UJ connected from its power source during cleaning, maintenance and parts
replacement.
Check the installation frequently for poor balancing or signs of wear or damage to cables, springs and mounting. Do not use the appliance if any repairs or adjustments are required. Only original parts should be used to replace or repair the motorised system.
For further information, see section
F – Maintenance
REMOTE CONTROLS
This product contains a button cell battery. If swallowed, the button cell
battery can cause severe internal burns in only 2 hours and may cause death.
Keep new and used batteries out of the reach of children. If the battery
compartment does not close securely, stop using the product and keep it out
of the reach of children. If you suspect a battery or other part has been
swallowed or inserted into any part of the body, seek medical advice
immediately. Do not clean the remote control with abrasive or corrosive
substances.
Just use a soft cloth. Do not allow children to play with the product or its packaging. When replacing batteries, ensure they have the same characteristics as the ones supplied with the product. If the device is not being used for a prolonged period, remove the batteries unless the system is intended for emergency situations. Do not expose the batteries to excessive heat or throw them in a fire.
Potential risks
Risk 1 : Shock and crushing
Prevention
- Obstacle detection by motor.
- Use of photocells.
Risk 2: Hand crushing
Prevention
- Leave a minimum distance of 10 cm between the leaf and the pillar/wall.
- Notch the corner of the pillar without weakening it.
Risk 3 : Imprisonment and crushing
Prevention
- Obstacle detection by the motor.
- Leave a minimum distance of 50 cm between the motor arm and the wall (or other fixed part).
Risk 4 : Crushing of the feet
Prevention
To avoid a danger zone for feet, leave a minimum distance of 12 cm or a
maximum of 5 mm between the bottom of the leaves and the floor.
DESCRIPTION
81- Contents
Dimensions
WIRING/ INSTALLING
C1- Standard installation
24V DC LED blinker with antenna
Photocells
24V DC gate opener
G) Remote control
C2- Dimension chart
Comply with the measures shown on the chart for proper installation. Adjust
the gate structure to fit it for best automation, if necessary.
Before starting the installation, please make sure that the gate moves freely and that
- Hinges are properly positioned and greased.
- No any obstacle in the moving area.
- No frictions between two gate leaf’s or and on the ground while moving.
- Enough space is left when the gate is opening.
- Distance perpendicularly from gate bolt to the front of fixing bracket.
- Distance from the bolt perpendicular to the surface of articulated arm opener.
- Distance between the position of arm fixation and the bolt.
- Installation angle from full closed and full opened position.
COTE A
minimum 50 mm
maximum 200 mm
COTE B
minimum 50 mm maximum 150 mm
Inside opening
Dimension chart
CJ- Motor fixing
- Refer to the Dimension Chart to choose the correct dimensions of the motors and position.
- Check if the mounting surface of the brackets to be installed is smooth, vertical and rigid.
- Arrange the cables for power supply cable of the motors.
- Motor installation and setting for mechanical stopper in opened and closed position.
Remove the upper cover and mechanical stoppers on the bottom of motor.
Place the gate in the full closed position and fix the LI-shaped fixing plate on the wall.
Install the motor on the LI-shape with screws (n°8) and corresponding nuts.
After positioning the front of curved arm on the bottom of motor, position the minor arm on the end of curved arm and mounting bracket with corresponding screws and nuts.
To unlock the arms refer to paragraph C4
Closed position adjustment: Once the full closed position is decided, fix
the corresponding mechanical stopper in this position.
Opened position adjustment : Adjust the gate to full opened position and once the position is decided, fix with corresponding mechanical stopper.
This operation must be carried out a second time to install the second arm
C4- Emergency release
- Insert the release key to the release slot
- Turn the release key clockwise
- Release and move the gate
At the beginning you may notice that the motors are difficult to release. ___
Do not worry, it will disappear with time.
Position of locked motor: the pintle should be exited
Position of unlocked motor: the pintle should be pressed
TIP
Instead of unlocking a motor with arms strength, you can use a battery
connecting the white and yellow motor cables one way or the other following
the polarity to operate the motors.
The white and yellow cables must be L ! 1 disconnected from the electronic card.
C5- Wiring diagram
Inside opening
Cas n°1
Cas n°2
The main and secondary motors can be installed on the right or on the left pillar.
C6- Installing
Power supply connections
Please kindly notice that the operation of power connection should be carried
out by a qualified electrician with following steps.
Make sure that all your connections (motors, blinker, antenna, photocells,
lock, etc.) are perfectly made before connecting the 230V power supply to the
grey domino.
See diagram (Figure 1 – page 24)
Wire connection secondary motor
Photocells
The photocells are safety devices for control automatic gates. Consist of one transmitter and one receiver based in waterproof covers; it is triggered while breaking the path of the beams. If an obstacle is detected, the gate stops and opens again slightly allowing the obstacle to be released safely.
Blinker
Remove any packaging before connecting.
If you want to improve the operating range of your remote, you can connect the blinker antenna with a RG58 coaxial cable (not supplied).
In this case you must disconnect the original antenna and then connect the coaxial copper core to the terminal ANT and the coaxial braided shield to the terminal GND on both antenna and ELECTRONIC cacd
SETTING/ USING
D1- Switch settings (dip switch 1)
Switch settings: « on» down position, «off» up position.
DIP SWITCH 1
ON = double gate operation
OFF = single gate operation (connection on 5 and 6)
D2- Power setting (dip switch 2 et 3)
DJ- Gate auto-close adjustment (dip switch 4)
DIP SWITCH 4
«ON»: Active automatic closing in 30 seconds. Simultaneously pressing the
two remotes top keys closed gate) will turn OFF the automatic mode (the
blinker will flash 3 times as confirmation). Repeat the operation to turn ON
the automatic mode (the blinker will flash 3 times as confirmation).
Note : in case of automatic closing, photocells are required.
«OFF» : Automatic closing OFF (caution it will still be possible to turn ON with the remote)
D4- Photocell adjustment (dip switch 5)
DIP SWITCH 5
ON: Photocells ON. When the photocells detect an obstacle while the gate
is closing, the gate stops and opens during 2 seconds.
If the gate auto-close is adjusted, and the photocells detect an obstacle when
the gate is totally opened, then the closing time will be reseted.
OFF : No detection by the photocells, the photocells will not control the
opening of the gate.
D5- Dephasing of the leaves (dip switch 6)
DIP SWITCH 6
ON: Dephasing in closing/ opening of 8 seconds.
OFF: Dephasing in closing/ opening of 3 seconds.
D6- Declaration speed
The speed is 70% output of the full speed (no adjustment possible).
D7- LED indication
LED 1 RF indicator : radio frequency
LEDl blinks when remote controls are activated.
LED 2 System learning
LED 2 blinks twice per seconded during normal operation and once per seconded
during learning. Static LED2 means incorrect programming.
LED 3 Photocells
LED 3 will be on when photocells are not aligned or when an obstacle is
between the photocells.
LED 4 Start
LED 4 will be on if the switch of the transmitter, key selector, or the push
button is activated.
DB- Remote controls learning process
Press “RF-learn” button for 2 seconds, and the Led will be on; then press the
transmitter top left button. The LEDl will blink twice and stay on for 10
seconds then be off. And the remote memorize has completed.
D9- System learning process double gate
L!\ The remote control memory storing operation must be over before starting
the final system learning process.
Let your gate totally opened then lock them (part C4)
Press «SYS-learn» (until the LED2 light begins to flash once every second,
instead of twice every second as it normally would), then press the upper-left
key for a double gate.
The system learning process will be as follows, step by step
After step 6, the system learning process is complete. You can use it with the remote control:
Double gate full following, pedestrian opening (Single gate)
The LED2 light will remain ON until the system learning process is not over. Check the wiring connection and repeat the step.
D10 – System learning process simple gate
Switch 1 OFF.
Totally open the leaf gate.
Press «SYS-learn» (until the LED2 light begins to flash once every second,
instead of twice every second as it normally would) , then press the upper-
right key for a single gate.
The system learning process will be as follows, step by step
E- TECHNICAL FEATURES
Motor
Dimensions 285 mm x 160 mm x 298 mm
The A-weighted emitted sound pressure level of the motor is equal or less than 70 dB (A).
Motor
Photocells
Remote controls
F- MAINTENANCE
F1- Motor
Conduct the following operations at least every 6 months. If in high intensity
of use, shorten the period in between.
Disconnect the power supply
- Clean and lubricate the screws, the pins, and the hinge with grease.
- Check the fastening points are properly tightened.
- Make the wire connection are in good condition.
Connect the power supply
- Check the power adjustments.
- Check the function of the manual release.
- Check the function of photocells or other safety device.
F2- Remote control
FJ- Maintenance advice
G- TECHNICAL ASSISTANCE
Troubleshooting
GJ- Free online
Any question?
For an individual answer, use our on line chat on our website www.scs-
sentinel.com
H-WARRANTY
SCS Sentinel grants to this product a longer warranty period, beyond the legal
time, as a sign of quality and reliability.
The invoice will be required as proof of purchase date. Please keep it during
the warranty period.
Carefully keep the barcode and the proof of purchase, that will be necessary
to claim warranty.
Are never covered by our warranty
- Damage resulting from the consequences of a bad installation (bad wiring, reverse polarity … ).
- Damage resulting from improper use of the device (use in contradiction with the manual) or its modification.
- Damage resulting from the consequences of the use of components not from SCS SENTINEL.
- Damage due to lack of maintenance, physical shock.
- Damage due to weather: hail, lightning, strong wind etc ..
- Returns made without a copy of the invoice or receipt.
WARNINGS
Don’t throw batteries or out of order products with the household waste
(garbage). The dangerous A A substances that they are likely to include may
harm health or the environment. Make your retailer take – back these products
or use the selective collect of garbage proposed by your city.
J- DECLARATION OF CONFORMITY
SCS Sentinel hereby declares that this product is in compliance with the
essential requirements and other relevant provisions of Directive 2014/53/EU
and Directive 2006/42/EC. The Declaration of Conformity can be found at: www
.scs-sentinel.com/downloads
110, rue Pierre-Gilles de Gennes 49300 Chalet – France
Read User Manual Online (PDF format)