WatchDog NXT85C Crawl Space Dehumidifier Installation Guide
- June 5, 2024
- WatchDog
Table of Contents
- WatchDog NXT85 Crawl Space Dehumidifier
- Important Notes
- Specifications
- Installation Requirements
- Installation
- Key Functions
- Indicator Lights
- Remote Control Instructions
- Operating Instructions
- Unit Diagram
- Maintenance
- Dehumidifier Storage
- Ducted Applications
- Troubleshooting
- Spare Parts
- Limited Warranty
- Warranty Exclusions
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
WatchDog NXT85 Crawl Space Dehumidifier
Important Notes
- Always connect your dehumidifier using a grounded, dedicated electrical connection that is GFCI protected with at least 15 amp capacity.
- The use of any other type of wiring will void your warranty.
- Install dehumidifier according to all applicable local, state, and national codes
- Be sure to follow your GFCI manufacturer’s maintenance instructions. You will typically need to test the operation of the trip circuit monthly.
- For ease of testing and operation, it may be helpful to put the test switch and indicator lights in a convenient location.
- Your dehumidifier should only be repaired by a qualified technician.
- Do not insert objects or your fingers into the inlet or discharge.
- Do not use water to clean the exterior of the dehumidifier. To clean unit, unplug from power, then use a damp cloth to wipe the exterior.
- Do not stand on the dehumidifier or place objects on it.
- Do not use with an extension cord or plug adapter.
- Unless otherwise noted, all maintenance should be done with the unit powered off.
Specifications
- Capacity @ 80°F/60%RH: 85 Pints Per Day
- Airflow @ 0.0” SP: 185CFM
- Operating Temp. Range: 33-105°F
- Operating Relative Humidity Range: 36%-90%
- COP: 2.71 L/kWh
- Refrigerant: R410A
- Amperage Usage: 5.3 Amps
- Power Supply: 115V/60Hz/Single Phase
- Outlet Requirement: 15 Amp, 3 prong, GFCI
- Sound Level: 59 dBa
- Dimensions LxWxH: 21.7” x 12” x 12”
- ETL Listed: Yes
How It Works
WatchDog dehumidifiers use an integrated humidistat to monitor the conditioned
space. When the relative humidity goes above the selected setpoint, the
dehumidifier will energize. Air is then drawn across an evaporator coil, which
is cooler than the dew point of air. This means moisture will condense out of
the air. The air is then reheated through the condenser coil and distributed
back into the room.
Installation Requirements
- The area where the dehumidifier is located should be sealed with a vapor barrier.
- If the unit is installed in a crawl space, all vents should be sealed.
- For proper ventilation, neither the inlet or discharge should be positioned against a wall. The inlet needs a minimum of 12” clearance and the discharge requires a minimum of 36” clearance.
- For the best air diffusion, install the unit so that a side panel faces the wall.
- WatchDog dehumidifiers are only intended for operation when the unit is upright and level with the feet on the ground.
Installation
Place the dehumidifier on a level surface.
- Do not place unit directly on vapor barrier. For example, use blocks or pavers to create a level surface.
- If unit has been turned or flipped so that the compressor did not remain upright, place the unit on a level surface and wait a minimum of 2 hours before proceeding.
Set up the drain line
- Remove the compression nut and slide it over the end of the hose to be attached to unit.
- Slide the side of hose with compression nut over the insert on the compression fitting completely.
- Tighten compression nut.
Plug unit into a dedicated, 15 amp GFCI protected circuit.
Key Functions
Power Key
- Use this button to turn the dehumidifier on and off.
- Press once to turn the machine on. You will hear two beeps and the light will illuminate green (solid or flashing depending on
- Press the power button a second time and you will hear one beep as the machine shuts down. Note that there is a 1 minute fan delay.
Arrow Buttons
- Use the up and down arrows to set the desired humidity setpoint on the display screen.
- The setpoint can be any number between 36%-90%. When the indoor humidity is higher than the setpoint, the unit will operate.
- Keep in mind that the displayed humidity levels are approximate ( +/-5%)
Continuous Mode
- To set the unit to run continuously regardless of humidity, simply use the down arrow key to set the humidity below 36%.
- The continuous light will illuminate green and the display will show “CO”.
- To switch back to normal humidistat operation, use the arrow keys to move the setpoint above 36%.
Manual Drain Button
- If you need to store or move your dehumidifier, press the “Drain” button to remove water from the integral pump’s reservoir.
Pump Trouble Warning
- If the pump reservoir level gets too high, the water sensor will activate to prevent overflow.
- When this occurs, the compressor will stop automatically, and the display will show “E4”. After a 1 minute delay, the fan motor will turn off and the dehumidifier will not operate until the problem has been resolved.
- Check to verify that the pump is functioning, then unplug the unit for two minutes to reset the error code.
Auxillary Terminals A5/A6
- The A5/A6 on the terminal strip can be used as a safety switch for an external float switch.
- It should be set to N/O (normally open) at the accessory float switch.
- If an E4 error occurs immediately, switch the wiring on external switch to N/C (normally closed). You may need to unplug the unit to reset the error code.
Indicator Lights
Humidity Display Screen
- The display screen has two functions:
- When the unit is powered on, it shows the humidity of the space
- When setting the desired humidity level, the screen will show the set point. After a brief delay, it will revert to current humidity of the space.
Power Indicator Light
- This light indicates that the unit is properly powered on and ready to operate.
- Always make sure the unit is “off” prior to performing any service, unless otherwise indicated.
- If the humidity is above the setpoint, the light will be solid green and the machine will operate.
- If the humidity is below the setpoint, the unit will be in standby mode and the light will be flashing.
Continuous Mode/ Auto Defrost Light
- When the light illuminates green, it indicates that the dehumidifier is set to continuous operation mode.
- When the light illuminates red, it means the unit is in auto defrost mode and clearing the evaporate coils of any ice buildup.
Compressor Light
- When the light illuminates red, it indicates the compressor has been initiated but is currently warming up.
- Once the light switches to green, it means the compressor is currently in working status.
Remote Control Instructions
WatchDog Dehumidifiers can be controlled using an optional remote accessory.
The remote connects to your dehumidifier via a 25’ CAT 5 cable, with the
integrated sensor giving you multiple options for monitoring surrounding
conditions.
Example #1- Install the dehumidifier in the laundry room and duct it into
the living room. Mount the remote in the living room and use the remote
sensor.
Example #2- Install the dehumidifier in your crawl space with the remote
mounted in your garage.
On/Off (Power) Button
Press the on/off button and the machine will start running. Press the button
again to turn the machine off.
Up Button/ Down Button
Use the up and down arrows to adjust the humidity level.
Mode
Use the mode button to switch between a dehumidifier and a ducted
application.
- The symbol on the display indicates the sensor on the remote control is being utilized.
- The symbol on the display indicates the sensor on the dehumidifier is being utilized.
Temperature
The T button changes the temperature reading on your remote. The remote comes
from the factory in Celsius. Press this button once to switch to Fahrenheit.
Continuous
Press this button to switch the unit into continuous mode. “CONT.” will appear
on the display screen.
Drain Pump
Use this button if the unit will not be used for an extended period of time.
This button will remove water from the pump reservoir.
Operating Instructions
- Start the machine
- Press the power key to turn the dehumidifier on.
- Adjust the settings
- Use the up and down arrow keys to adjust your desired setpoint (typically 50-55%)
- Stop the machine
- Press the power button again and the dehumidifier will stop. Note that the fan will continue to operate for 1 minute after the unit has shut off. DO NOT DISCONNECT THE POWER CORD TO FORCE THE UNIT TO STOP.
- Water Drainage
Unit Diagram
Maintenance
For more detailed instructions, visit www.SeairaGlobal.com
WARNING: Always unplug the unit before doing any maintenance.
Cleaning the Machine Body**
- Use a soft, damp cloth to clean the exterior of unit. Do not use any soap or solvents
Coil Maintenance
- Once per year, clean the coils with an approved coil cleaner. The coil cleaner should be a self-rinsing, foaming, cleaner, such as WEB® Coil Cleaner.
Cleaning the Filter
- Unplug the unit.
- For PreFilter:
- a. Remove prefilter from the inlet of the machine.
- b. Vacuum or wash with warm water (no soap).
- For MERV-10/HEPA/Carbon Filters:
- a. Replace as necessary- we recommend checking the filter at least 1x/year
Electrical Access
- Unscrew the 9 screws on the sideboard.
- Remove the 2 screws on the control board cover.
Pump Maintenance
Your WatchDog NXT85c is equipped with an integral condensate pump designed to
pump water from the dehumidifier out to the desired drain. The pump requires
routine maintenance that is not covered by the warranty. Preventative
maintenance is necessary to prevent issues from dirt and slime that may
accumulate in the drain system. This includes the drain pan, hose to the
condensate pump, pump reservoir, pump head assembly, and discharge tubing.
Removing the Pump
- Remove the 9 screws on the side panel and set panel aside.
- Remove the screw holding the pump in place.
- Undo the 3 pump electrical quick connects and 1 drain quick connect.
- Insert a flat head screwdriver into the notch on the side of the pump. This will allow you to gently lift the pump off its reservoir (the reservoir remains attached to the unit).
Basic Pump Cleaning
- Remove filter(s) from inlet of unit to access drain tray. Press the drain button to drain the reservoir.
- Disconnect power to the dehumidifier.
- Mix a 16-ounce solution of bleach (1 oz bleach + 15 oz water) OR vinegar (4 oz white vinegar + 12 oz water).
- Pour the cleaning solution into the drain tray at the base of the coils. If any cleaning solution gets on the coils, flush with water.
- Allow the solution to soak for 15 minutes.
- Reconnect the dehumidifier to power.
- Fill the reservoir with water (16-32 ounces) and flush/cycle the pump at least 2x.
- If the drain line is still filled with debris, repeat process. If drain line still does not appear clean, move on to Advanced Cleaning.
Advanced Pump Cleaning
Complete as needed
- Press the drain button to drain the water from the reservoir (a wet-dry vacuum or towels can be used to remove any remaining water).
- Unplug the dehumidifier and remove the cover so you have access to the pump.
- Remove the pump head from the reservoir by unscrewing the screw. Wipe reservoir clean with a paper towel.
- Reassemble pump.
- Mix a 16 ounce solution of bleach (1 oz bleach + 15 oz water) OR vinegar (4 oz white vinegar + 12 oz water).
- Pour the cleaning solution into the drain tray at the base of the coils. If any cleaning solution gets on the coils, flush with water.
- Allow solution to soak for 15 minutes.
- Reconnect the dehumidifier to power.
- Fill the reservoir with water (16-32 ounces) and flush/cycle the pump at least 2x.
Dehumidifier Storage
If the unit will be stored for an extended period of time, complete the following steps:
- Turn off the unit and allow it to dry.
- Wrap and secure the power cord.
- Cover the filter mesh.
- Store in a clean, dry space.
Ducted Applications
Ducting the dehumidifier allows the unit to be in one room while conditioning
an adjacent room. Both the inlet/return grille and the supply grille are
designed for 10” flex ducting.
Ducting Installation Notes
- Be sure to secure the ducting with tie wrap.
- Maximum total length of duct run = 10’
- Inlet and outlet duct adapters are optional accessories
Duct Adapter Installation
- Screw in the 4 screws on each duct adapter.
Flex Duct Installation
- Slide ducting over the adapter and secure with a tie-wrap or clamps
Troubleshooting
Spare Parts
Limited Warranty
All warranty benefits apply to the original owner only. Warranty cannot be
transferred or assigned.
5 Years (From Date of Purchase):
Seaira Global warrants the dehumidifier will operate free of defects in
workmanship and materials. At its discretion, Seaira will repair or replace
any malfunctioning components, free of charge
(excluding transportation costs)
Customer Responsibilities:
In order to take advantage of the warranty service, the customer must do the
following:
Customer must provide normal care and maintenance (including, but not limited
to cleaning filters, coils and pumps)
- Removal and re-installation of unit is the sole responsibility of owner.
- If customer cannot return unit to certified repair center, all costs associated with freight shipment are borne by the customer. In addition, all ancillary charges related to freight shipments, including but not limited to palletizing, wrapping, labeling, and pickup are associated with the customer.
- If shipped, customer is responsible for all risk of loss or damage.
Warranty Procedure:
-
Customer must mail in warranty registration card to Seaira Global. If no card is submitted, warranty period will begin the day the shipment left the warehouse. Please be sure to record serial # and date of installation in the spaces provided on page 2 of the manual. You will need this information to receive an RA number.
-
If warranty service is necessary, customer must contact Seaira Global Tech Support by phone 910-660-0962 to receive a Return Authorization (RA number).
-
Once an RA has been issued, it is the customer’s job to bring the unit to a certified repair center.
If this is not an option, shipping will be arranged to bring the unit back to the Seaira warehouse (at the expense of the customer). -
After the unit has been received by Seaira (whether at a repair center or the warehouse), an initial inspection will be completed, if it is determined to be an invalid warranty claim (see exclusions below), unit will only be completed after receiving payment from customer for all associated costs.
-
If unit is defective, the necessary parts will be repaired or replaced and the unit will be available for pickup at certified repair center or returned via freight shipment (at customer’s expense). Keep in mind that work is only done during normal working hours. After being repaired, all units are required to go through a rigorous testing process prior to being returned to customer.
-
Once a part is repaired and the dehumidifier is returned, the original warranty period still applies (no extensions).
Warranty Exclusions
THE FOLLOWING IS NOT COVERED UNDER WARRANTY
- ACTS OF NATURE- INCLUDING BUT NOT LIMITED TO:
- FLOODING
- FIRE
- WATER DAMAGE
- HURRICANE/STORM DAMAGE
- IMPROPER USAGE- INCLUDING BUT NOT LIMITED TO:
- POOL/SPA/TUB APPLICATIONS
- MISUSE, ABUSE, OR TAMPERING WHETHER INTENTIONAL OR ACCIDENTAL
- IMPROPER INSTALLATION OR DESIGN
- IMPROPER VOLTAGE
- LACK OF NORMAL CARE
- FAILURE TO FOLLOW INSTRUCTIONS
- CORROSION
- FREEZING
- ANY ADDITIONAL COSTS DUE TO CHANGES IN LAWS OR BUILDING CODES
- FREIGHT CHARGES
- ANY COSTS DUE TO LOST PROFIT OR DELAY
- DAMAGE TO PROPERTY
- CAUSE BEYOND CONTROL
- CONSUMABLE PARTS, INCLUDING BUT NOT LIMITED TO:
- FILTERS
- BATTERIES
- POWER CORDS
- VALVES
- SWITCHES
- RUBBER PARTS
- APPLICABLE LAW AND VENUE ALL ASPECTS OF THIS AGREEMENT SHALL BE INTERPRETED BY AND UNDER THE LAWS OF THE STATE OF NORTH CAROLINA. ANY LITIGATION, ENFORCEMENT OF ARBITRATION, OR LITIGATION RELATED TO SHALL BE BROUGHT IN THE APPROPRIATE COURT IN NEW HANOVER COUNTY, NORTH CAROLINA.
- DIRECT, INDIRECT, COLLATERAL OR INCONSEQUENTIAL DAMAGES OF ANY KIND THE WARRANTIES AND LIABILITIES SET FORTH ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, IN LAW OR IN FACT, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. SEAIRA GLOBAL’S TOTAL LIABILITY, REGARDLESS OF NATURE OF THE CLAIM SHALL NOT EXCEED THE ORIGINAL PURCHASE PRICE OF THE PRODUCT. IF A PRODUCT OR COMPONENT IS REPLACED WHILE UNDER WARRANTY, THE APPLICABLE WARRANTY PERIOD SHALL NOT BE EXTENDED BEYOND THE ORIGINAL WARRANTY TIME PERIOD. THE FOREGOING SHALL CONSTITUTE THE TOTAL LIABILITY OF THE SELLER IN THE CASE OF DEFECTIVE PERFORMANCE OF ALL OR ANY OF THE EQUIPMENT OR SERVICES PROVIDED TO THE BUYER. BUYER AGREES TO ACCEPT AND HEREBY ACCEPTS THE FOREGOING AS THE SOLE AND EXCLUSIVE REMEDY FOR ANY BREACH OR ALLEGED BREACH OF WARRANTY BY SELLER. ANY DISHONESTY OR FRAUD IN CONNECTION WITH SEAIRA GLOBAL WARRANTY THOROUGHLY VOIDS ALL WARRANTY POLICIES. SEAIRA GLOBAL EXPRESSLY RESERVES THE RIGHT TO PURSUE LEGAL ACTION IN THE EVENT OF DISHONESTY, FRAUD, OR ATTEMPTED FRAUD.
Read User Manual Online (PDF format)