SAFETY INSTRUCTIONS

This manual is an integral part of your product. These instructions are provided for your safety. Read this manual carefully before installing and keep it in a safe place for future reference. Select a suitable location. Make sure you can easily insert screws and wallplugs into the wall. Do not connect your electrical appliance until your equipment is totally installed and controlled. The installation, electric connections and settings must be made using best practices by a specialized and qualified person. The power supply must be installed in a dry place. Check the product is only used for its intended purpose.

DESCRIPTION

Content/ Dimensionsscs-sentinel-CodeAccess-A-Coding-Keypad-
fig-1

WIRING/ INSTALLING

Installing

scs-sentinel-CodeAccess-A-Coding-Keypad-fig-2

Wiring diagram
You don’t need a transformer if your automation is an SCS Sentinel.

To gate automation

scs-sentinel-CodeAccess-A-Coding-Keypad-fig-3

To strike/electric lock

scs-sentinel-CodeAccess-A-Coding-Keypad-fig-4

TO RESET TO FACTORY DEFAULT

  • Disconnect power from the unit
  • Press and hold# key whilst powering the unit back up
  • On hearing two “Di” release# key, system is now back factory settings Please note only installer data is restored, user data will not be affected.

INDICATIONS

scs-sentinel-CodeAccess-A-Coding-Keypad-fig-9

USING

Fast programming

Programming a code

scs-sentinel-CodeAccess-A-Coding-Keypad-fig-5

Programming a badge

scs-sentinel-CodeAccess-A-Coding-Keypad-fig-6

Door opening
Trigger the opening through user code

  • To trigger the opening with a badge, you only have to present the badge to the keypad.

Detailed Programming Guide

User Settings

scs-sentinel-CodeAccess-A-Coding-Keypad-fig-10 scs-sentinel-CodeAccess-A-Coding-Keypad-fig-11

Door settings

scs-sentinel-CodeAccess-A-Coding-Keypad-fig-12

Changing the master code

scs-sentinel-CodeAccess-A-Coding-Keypad-fig-13

For security reasons, we recommend changing the master code from default.

TECHNICAL FEATURES

  • Voltage 12V DC +/-10%
  • Badge reading distance 0-3 cm
  • Active current< 60mA
  • Stand-by current 25±5mA
  • Lock load output 3A max
  • Operating temperature -35°C ~ 60°C
  • Relay output delay time
  • Possible wiring connections: electric lock, gate automation, exit button
  • Backlight keys
  • 100 users, supports badge, PIN, badge+ PIN
  • Full programming from the keypad
  • Can be used as a stand-alone keypad
  • The keyboard can be used to remove the lost badge number, thoroughly eliminate the hidden safety trouble
  • Adjustable Door Output time, Alarm time, Door Open time
  • Fast operating speed
  • Lock output current short circuit protection
  • Indicator light and buzzer
  • Frequency: 125 kHz
  • Maximum transmitted power: <20mW

Online assistance

Any question?
For an individual answer, use our online chat on our website www.scs- sentinel.com

WARRANTY

Warranty 2 years
The invoice will be required as proof of purchase date. Please keep ij during the warranty period. Carefully keep the barcode and the proof of purchase, that will be necessary to claim warranty.

WARNINGS

  • Maintain a minimum distance of 10 cm around the device for sufficient ventilation.
  • Keep matches, candles, and flames away from the device.
  • Product functionality can be influenced by strong electromagnetic interference.
  • This equipment is intended for private consumer use only.
  • The appliance should not be exposed to dripping or splashing water; no objects filled with liquids, such as vases, should be placed near the appliance.
  • Do not use in a tropical climate.
  • Connect all the parts before switching on the power.
  • Do not cause any impact on the elements as their electronics are fragile.
  • When installing the product, keep the packaging out of reach of children and animals. It is a source of potential danger.
  • This appliance is not a toy. It is not designed to be used by children.
    • Disconnect the appliance from the main power supply before service. Do not clean the product with solvent, abrasive or corrosive substances. Only use a soft cloth. Do not spray anything on the appliance.
    • Make sure that your appliance is properly maintained and regularly checked in order to detect any sign of wear. Do not use it if a repair or adjustment is needed. Always call on qualified personnel.
    • Don’t throw batteries or out-of-order products with the household waste (garbage). The dangerous substances that they are likely to include may harm health or the environment. Make your retailer take back these products or use the selective collection of garbage proposed by your city.
  • Direct current

Toutes les infos sure :www.scs-sentinel.com

  • 110rue Pierre-Gilles de Gennes 49300 Chalet – France

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SCS sentinel User Manuals

Related Manuals