Product Information

Specifications

  • Protocol: Z-Wave Plus, 868.4MHz
  • Chip: Z-Wave 700 chip
  • Rated Voltage: 230VAC 50Hz
  • Max Load: 3600W (resistive load), 750W self-limiting heating cable
  • Max Current: 16A

Product Usage Instructions

Installation
Installation must be done by a qualified electrician following national building codes. Before installation, ensure the power is disconnected from the mains at all times.

Connection
Use 1.5mm to 2.5mm cables based on the connected load for the device mains power. Connect the load between the Output (O) and Neutral (N). Power connections for Live (L) and Neutral (N) are at 230VAC.

Add/Remove Device

  1. Set the primary controller to add mode (secure/non-secure).
  2. Press the configuration button or switch connected to S1 three times rapidly.
  3. The LED will blink in green to indicate successful initiation of the adding procedure.
  4. Adjust Parameter 11 to 10% of your connected load.
  5. If adding is successful, the LED will stay green for 3 seconds. The device is ready for use with default settings.
  6. If adding fails, the LED will turn red for 3 seconds. Try removing and adding again.

Resetting Parameters
If the device is removed from the gateway, parameters are not reset. Refer to the full manual for instructions on resetting parameters.

Frequently Asked Questions (FAQ)

  • Q: What should I do if the LED turns red during adding?
    A: If the LED shows red during adding, please perform a remove device process and try adding again. Consult the full manual for further assistance on adding, removing, and factory reset procedures.

INTRODUCTION

Heatit ZM Single Relay is a high power relay for in-wall installations. The relay allows you to control connected devices either through your Z-Wave network or via a wired switch. The module is equipped with a 16A relay and has a scene controller functionality. The device can withstand a load of max 16A/3600W at 230VAC.

STATEMENT REGARDING PRODUCTS FROM MULTIPLE MANUFACTURERS
Please read this before installation:
This device may be used with all devices certified with the Z-Wave Plus™ certificate and should be compatible with such devices produced by any manufacturer. Every primary controller is different depending on the manufacturer, their target audience and intended use/application. Please review the functionalities implemented by the primary controller you intend to use with our Z-Wave Plus certified device to ensure that it provides the necessary controls to take full advantage of our product’s capabilities.

INSTALLATION

Installation must be done by a qualified electrician in accordance with national building codes. Before installation, disconnect the power to the device from the mains. During installation of the device, power to the device must be disconnected AT ALL TIMES!

Use 1.5mm to 2.5mm cables according to connected load for the device mains power.HEATIT-16A-ZM-SINGLE-RELAY- \(2\)

  • N Power connection (Neutral) 230VAC.

  • O Output. Load needs to be connected between O and Neutral.

  • L Power connection (Live) 230VAC.

  • L Power connection (Live) 230VAC.

  • S2 Switch 2 is used as a scene controller.
    NB! In toggle mode, S2 must not be connected.

  • S1 Switch 1. Used to control the internal relay.

ADD/REMOVE

  1. Set the primary controller to add mode (secure/non-secure).
  2. Press the configuration button or switch connected to S1 x 3 times in rapid succession.
  3. The device LED will blink in green when adding procedure has been successfully initiated.
  4. Change the value of Parameter 11 to 10% of your connected load.

When the device has been included in the home automation system, the LED will stay green for 3 seconds. The device is now ready for use with default settings.
If the adding process was unsuccessful, the LED will show a red light for 3 seconds. Please perform a ”remove device” process and try to add again. If the LED goes red, please see the full manual for more information regarding adding, removing and factory reset.
Adding/removing mode is indicated on the device by a flashing green light. This lasts until timeout occurs after 90 seconds, or until the device has been added/removed from the network.
NB! When the device is removed from the gateway, the parameters are not reset. To reset the parameters, see the full manual.

HEATIT-16A-ZM-SINGLE-RELAY- \(3\)

TECHNICAL DATA

  • Protocol Z-Wave Plus, 868.4MHz
  • Chip Z-Wave 700 chip
  • Rated voltage 230VAC 50Hz
  • Max load
    • 3600W (resistive load)
    • 750W self-limiting heating cable
  • Max current 16A
  • Power consum. <1W
  • Ambient temp. 5°C to 40°C
  • Storage temp. -30°C to 70°C
  • Humidity Max 95% RH
  • Range RF Min. 40 meters
  • IP Code IP 20
  • Size (DxWxH) 46 x 45 x 25mm
  • Approvals
    • Z-Wave Plus V2,
    • CE,
    • EN 60669-1:2018,
    • EN 60669-2-1:2004 + A1:2009,
    • EN 60669-1:2004/A12:2010,
    • EN 60669-2-5:2016,
    • IEC 965-2-1, EN 62479:2010,
    • ETSI EN 301 489-3 V2.1.1(2017-03),
    • ETSI EN 300 220-2 V3.1.1(2017-02),
    • RoHs 2002/95/EG,
    • WEE 2002/96/EC

Heatit Controls AB can not be held liable for typographical errors, other errors or omittances in our information. Product specifications may change without further notice. All electrical installations must be carried out by a licensed electrician. The product must be installed in accordance with national building codes and our installers manual.

Heatit Controls AB l Läkarvägen 4, 454 31 BRASTAD, SWEDEN
Phone: +47 61 18 77 77
post@heatit.com
www.heatit.com

Read the full manual at: manuals.heatit.com

HEATIT-16A-ZM-SINGLE-RELAY- \(1\)

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals