Specifications
- Operating Voltage: 220-240V, 50/60Hz
- Protection Rating: IP66
- Optical Gear: IK08 / IK03
- LED Color Codes: 722, 727, 827, 730, 830, 740, 840, 757, 857, 957
- Energy Efficiency Class: D, C, B
- Dimensions and Weight:
- Size 1: 236mm x 186mm, 3kg
- Size 2: 243mm x 193mm, 3.3kg
- Size 1 with IP Cover: 277mm x 243mm, 3.6kg
- Size 2 with IP Cover: 271mm x 237mm, 4kg
Product Usage Instructions
Product Overview
The Circle LED Base comes in two sizes (Size 1 and Size 2) with or without an
IP cover. Ensure you have the correct size for your installation needs.
Mounting Dimensions
The LED luminaire comes with a standard adaptation plate and mounting clamps
for easy installation. Follow the provided mounting dimensions for proper
installation.
Electrical Connection
Follow the cable types and connections specified in the manual based on
whether you are using the luminaire with or without an IP cover. Make sure to
adhere to the specified cable sizes and connection instructions for safe
electrical setup.
FAQ
Q: Can I replace the light source in the luminaire myself?
A: The light source should only be replaced by the manufacturer, their service
agent, or a qualified person to ensure safety and proper functioning.
INSTALLATION INSTRUCTIONS
PRODUCT OVERVIEW
MOUNTING DIMENSIONS
Standard adaptation plate and mounting clamps are supplied together with the LED luminaire by default.
ELECTRICAL CONNECTION
SAFETY INSTRUCTIONS
The light source contained in this luminaire shall only be replaced by the
manufacturer or his service agent or a similar qualified person. Always switch
off the power prior to installa-tion, maintenance or repair activities.
RISK GROUP 2 – CAUTION! Hazardous optical radiation may be emitted from this
product. Do not stare at the luminaire when operating as it may be harmful to
the eyes. The luminaire should be positioned so that prolonged staring at the
luminaire at a distance of less than 0.94m is not expected.
This product contains a light source of an energy efficiency class … – see
table.
In case of PVC insulated mains cable, the installer MUST ensure that the WHOLE
cable is protected against climatic conditions, especially UV rays and rain,
by making sure that the cable is contained inside the luminaire and pole
DISCLAIMER
The performance characteristics of the complete lighting product may differ from those published for the independent Circle LED Base unit. Schréder will not hold any responsibility for the performance of the complete lighting product in which the Circle LED Base is integrated nor for any legal obligation related to this complete lighting product. Schréder’s instructions and installation sheets shall always be strictly complied with. Any warranty granted with the Circle LED Base shall cover the Circle LED Base itself and not the complete lighting product.