Schreder CLB1 Circle LED Base for Hestia MIDI
Specifications:
- Product Name: CIRCLE LED BASE 1&2 for HESTIA MIDI
- Dimensions: 625mm x 132mm x 257mm
- Weight: 185.7mm
- Compatible with HESTIA MIDI luminaire
- Adaptation plate size: 236mm x 83mm
Product Usage Instructions
Preparation
- Disconnect the luminaire from the network.
- Clean the surface of the luminaire.
- Open the luminaire to access the gear compartment and light source.
\ Installation Steps
- Disconnect mains power.
- Disconnect HID cables.
- Remove screws holding the optical compartment. Keep them for later use.
- Remove the optical compartment.
- Remove optical compartment connection to gear plate.
- Remove gearplate.
- Apply silicone sealant in the sealing groove.
- Place CLB adaptation plate into the luminaire.
- Fix the adaptation plate using clamps and screws previously removed.
- Connect the earthing cable of the adaptation plate to the luminaire body.
- Connect mains cable to CLB unit.
- Fasten the adaptation plate and clamps with screws (tightening torque: 2Nm).
- Close the lock on the bottom side of the luminaire.
Frequently Asked Questions (FAQ):
Q: Can I use CLB2 with HESTIA MIDI?
A: Yes, CLB2 is also available for HESTIA MIDI with the same adaptation plate
size dimensions, only the cut-out is different.
TOOLS REQUIRE
All the tightening torques values are given for assemblies without the addition of a grease-decreasing friction.
DIMENSION
CLB2 is also available for HESTIA MIDI, with the same adaptation plate size dimensions (only the cut-out being different)
INSTALLATION INSTRUCTION
- Disconnect the luminaire from network and clean the surface
- Open the luminaire for gear compartment and light source access
- Disconnect mains
- Disconnect HID cables
- Remove screws holding the optical compartment. KEEP THESE FOR LATER USE!
- Remove optical compartment
- Remove optical compartment connection to gear plate
- Remove gear plate
- Use silicone sealant in the sealing groove and place CLB adaptation plate into the luminaire
- Fix the adaptation plate into position in the luminaire body with the clamps provided and the screws previously removed
- Fasten the adaptation plate and clamps with the screws (tightening torque: 2Nm)
- Connect earthing cable of the adaptation plate to luminaire body
- Connect mains cable to CLB unit
- Close the lock on the bottom side of the luminaire
- Connect the assembly back on the network