TELETEK IRIS4 Series Addressable Fire Alarm System Owner’s Manual
- July 20, 2024
- Teletek
Table of Contents
TELETEK IRIS4 Series Addressable Fire Alarm System
Flexible solution for installations
Flexible solution for installations with high standards!
iRIS4 is the most versatile fire alarm panel in Teletek’s portfolio. The panel offers a huge variety of functionalities, which help the installers for any type of installation – from small to large buildings. The initial purpose of iRIS4 is to be used for fire alarm warning but due to its flexible design it can be modified to carry out many other functions like control and indication applications.
1000 addressable devices in one system
iRIS4 fits up to 4 loops and has a maximum coverage of 96 zones. Up to 250
devices can be connected to every system loop, giving a total of 1000 devices
for the whole system. The panel expandability makes it suitable for small,
medium and even large projects.
panels in network
Up to 64 panels in the network
- To cover the needs of the large installations, our iRIS series provides networking options between the panels. Up to 64 iRIS4 panels can be connected in a network, making it ideal for the largest sites including schools, hospitals, supermarkets, critical infrastructure and major commercial and industrial facilities.
- There are two options for connecting iRIS4 panels in a network – via LAN(Ethernet) or Redundant(RS485) connection.
Remote access
- Each iRIS4 panel could be connected to the Teletek-Cloud. The panel has a built-in LAN card, which allows it to be connected to the Internet. Any user registered to the Cloud can add the panel easily by scanning a QR code which could be found inside the panel’s menu. Teletek-Cloud offers wide range of functionalities such as:
Hybrid Fire Alarm System
- We combined the knowledge that we’ve gained over the years of experience in the field of wireless technologies, used by our intruder alarm solutions, with the professional approach of our fire systems, to create a wireless fire solution that provides the same high levels of reliability and life safety provided by a standard wired system, alongside the superior flexibility of wireless technology.
Smart control
One of the greatest benefits of the iRIS4 panel is the logical programming of
cause-and-effect scenarios. This functionality builds on to the initial
purpose of the panel as a fire alarm system and allows it to be used for
various applications. The logical programming of inputs and outputs can be
used to manage different scenarios, such as – triggering of physical
outputs(relays), generating events in the system, triggering network events,
taking actions, etc…
Serial connection with PA/VA system
The cooperation between the voice evacuation and the fire alarm panels is
crucial for the reliability of the systems. iRIS4 supports serial connection
to our SPIKA voice evacuation and public announcement system. The serial link
assures that the fire alarm panel will send all the information and will
trigger the voice evacuation, in case of a fire condition.
Galvanic Isolated Loop boards
The panel supports up to 4 loop expansion cards, as each of them could work
with up to 250 addressable devices. However, thanks to the modular structure
of the iRIS4, the installer might easily add or remove loop expansion boards,
depending on the installation specifics. iRIS4 loop expander cards are
galvanically insulated. The isolation protects the loop line against false
alarms and line communication interference.
“Clean me now” message
iRIS4 panel has an algorithm for measuring the pollution levels of the
addressable smoke detectors. When the pollution of the smoke chamber of a
certain detector reaches critical levels that may affect the proper work of
the system, the panel will generate a special fault message – Clean me now.
72H backup power supply
Some markets and installations have specific requirements regarding the backup
power supply of the fire alarm systems. By using expansion boxes, iRIS4 can be
configured to support additional backup batteries to achieve 72 hours in
standby without a mains power supply.
Thermal Printer
iRIS4 is equipped with an interphase for connection with a thermal printer,
which is used for printing the event log of the system. IRIS Printer box can
be mounted together with the iRIS4 panel to provide a modular box structure,
containing both the re-alarm panel and the printer.
RED colored panel box
iRIS4 has a red box modification, suitable for markets and installation with
specific requirements regarding the color of the fire alarm panel.
Loop and battery calculator software
Planning the installation precisely can save you a lot of time and trouble. As we mentioned, our iRIS4 supports up to 250 devices per loop. However, this number can vary depending on the type of devices that we use. That is why we strongly suggest the installers to use our Loop and Battery Calculator application, which can be downloaded for free from our official website. The application allows the installer to calculate the system configuration, before the actual installation, to limit the margin for errors.
BMS Integration Protocol
iRIS4 supports MODBUS protocol for connection with BMS software. The integration is possible thanks to the built-in LAN network of the iRIS4 panel.
Did you know…
The presence of people is the main reason for false fire alarms. Our iRIS
panels have a schedule feature, which allows us to create a day/night
sensitivity mode for the addressable fire detectors in the system. The main
task of this schedule is to lower the sensitivity in the period of the day
with a higher chance of false alarm, and respectively increase the sensitivity
back to normal for the rest of the day.
TELETEK ELECTRONICS
- Adress: 2 Iliyansko shose Str., 1220 Sofia, Bulgaria
- Telephone: +359 2 9694 800
- E-mail: info@teletek-electronics.bg
- Website: www.teletek-electronics.com