PEDROLLO HT-PRO Stainless Steel Multi Stage Centrifugal Pumps User Guide
- July 18, 2024
- pedrollo
Table of Contents
HT-PRO Stainless Steel Multi Stage Centrifugal Pumps
“`html
Specifications:
-
Pump Type: Multi-stage centrifugal pump
-
Material: Stainless steel AISI 304
-
Applications: Clean water, Civil use, Agricultural use,
Industrial use -
Electric Motor: Three-phase with IE3 efficiency class,
Single-phase with IE2 efficiency class -
Protection: Class F insulation and IPX4 protection
Product Usage Instructions:
1. Installation:
Follow these steps to install the HT-PRO Stainless steel
multi-stage centrifugal pump:
-
Choose a stable and flat surface for installation.
-
Connect the pump according to the provided electrical
specifications. -
Ensure proper ventilation around the pump for efficient
operation.
2. Operation:
To operate the pump:
-
Turn on the power supply and ensure the pump is primed.
-
Monitor the pressure and flow rate to ensure optimal
performance. -
Check for any unusual noise or vibrations during
operation.
3. Maintenance:
Regular maintenance is essential for prolonging the life of the
pump:
-
Inspect and clean the pump components regularly.
-
Check for leaks or worn-out parts and replace them as
needed. -
Keep the pump motor well-lubricated for smooth operation.
FAQ:
Q: What are the available requests for the HT-PRO pump?
A: The available requests include:
- AISI 316 stainless steel pump
- Handling of liquids with higher or lower temperatures
- Pump body with NPT threaded ports ANSI B 1.20.1
- Pump protection kit to prevent dry running
- O-rings in EPDM or VITON (standard version in NBR)
Q: What are the key features of the HT-PRO pumps?
A: The key features include:
- High hydraulic performance
- Robust, compact, and reliable mechanical construction
- Long service life with low noise operation
- Stainless steel components for enhanced efficiency
“`
HT-PRO Stainless steel multi-stage centrifugal pumps
Pump entirely made of stainless steel
Clean water Civil use Agricultural use Industrial use
HT-PRO pumps are designed for high hydraulic performance combined with a
robust, compact and reliable mechanical construction.
PERFORMANCE RANGE
· Flow rate up to 800 l/min (48 m3/h) · Head up to 160 m
INSTALLATION AND USE Designed to transfer clean water free from abrasive
particles and liquids that will not damage the pump’s components. Their high
efficiency and adaptability to a wide variety of applications make them an
ideal choice in the domestic, civil, agricultural, and industrial sectors,
particularly for water distribution along pressure tanks to increase overall
network pressure. Suggested uses include fire-fighting systems, heavy-duty
cleaning applications, industrial power washers, and irrigation.
KEY FEATURES The multi-stage stainless steel construction guarantees
a long service life and a very low noise threshold during operation. Stainless
steel components extend service life and enhance efficiency. Multi-stage
design results in exceptionally quiet operation
50 Hz | HT-PRO
Pump body: Stainless steel AISI 304
Cover:
Stainless steel AISI 304
Jacket
Stainless steel AISI 304
Impellers: Stainless steel AISI 304
Diffusers: Stainless steel AISI 304
Shaft
Stainless steel AISI 431
APPLICATION LIMITS
· Manometric suction head up to 7 m · Liquid temperature between -15 °C and
+90 °C · Ambient temperature up to +40 °C · Maximum working pressure 16 bar
ELECTRIC MOTOR The three-phase pumps are equipped with newly developed
electric motors designed to work with inverters, which guarantee stable and
quiet operation. Efficiency class IE3 for three-phase motors and IE2 for
single-phase motors, with class F insulation and IPX4 protection.
AVAILABLE UPON REQUEST AISI 316 stainless steel pump Handling of liquids with
higher or lower temperatures. Pump body with NPT threaded ports ANSI B 1.20.1
Pump protection kit to prevent dry running O-rings in EPDM or VITON (standard
version in NBR) Different voltage requirements 60 Hz frequency
HT 3 – PRO
CURVES AND PERFORMANCE DATA HS=0 m
Head H (metres) 4
0
5
0
5
170
HT 3/10-PRO 160
150 HT 3/9-PRO 140 130 HT 3/8-PRO
120 HT 3/7-PRO
110
100 HT 3/6-PRO
90 HT 3/5-PRO
80
70 HT 3/4-PRO 60
50
40
30
20
10
0
0
10
20
0
1
4
10
30
40
2
10
50 3
15 60
NPSH (metres)
3
2
P2 (kW)
1
0.4 Power input per stage
0.35
0.3
0.25
0.2
0.15
0.1
0
10
20
30
40
50
60
Flow rate Q 4
20 15
= 43%
50 Hz
US g.p.m. 20 Imp g.p.m.
feet
MEI 0.40
500 40.3
400
H (feet)
300
200
100
NPSH (feet)
70 4
70
0
80
90
l/min
5
m³/h
10
5
0.5
0.4
0.3
0.2
80
90
l/min
P2 (HP)
TYPE Single-phase Three-phase
POWER (P2)
m³/h 0
kW HP 1~ 3~ Q l/min 0
0.3 0.6 1.2 2.4 3.6 4.8 5.4 5 10 20 40 60 80 90
HTm 3/4 – PRO HT 3/4 – PRO 0.75 1
65 65 63.5 62 57 50 40.5 35
HTm 3/5 – PRO HT 3/5 – PRO 1.1 1.5
81 80 79 77 71 62.5 51 44
HTm 3/6 – PRO HT 3/6 – PRO
1.5
2
97 96 95 93 86 75 61 52
HTm 3/7 – PRO HT 3/7 – PRO
1.8 2.5 IE2 IE3 H metres 113 112 111 108 100 88 71 61
HT 3/8 – PRO 2.2 3
129 128 127 124 114 100 81 69.5
HT 3/9 – PRO
3
4
146 144 143 139 129 113 91 78
HT 3/10 – PRO 3
4
160 159 155 143 125 102 87
Q = Flow rate H = Total manometric head HS = Suction height
Performance curves comply with EN ISO 9906 Grade 3B tolerance limits.
Start of production 06.2024
HT 3 – PRO | 50 Hz
HT 5 – PRO
CURVES AND PERFORMANCE DATA HS=0 m
Head H (metres) 4
0
0 170
160 HT 5/9-PRO 150
140 HT 5/8-PRO
130 120 HT 5/7-PRO
110 HT 5/6-PRO 100
90 HT 5/5-PRO
80 70 HT 5/4-PRO
60 HT 5/3-PRO
50
40 HT 5/2-PRO 30
20
10
0
0
10 20
0
1
4
10 10
30 40 50
2
3
20 20
60 70 4
80 90 5
30 = 53.5%
50 Hz
US g.p.m. Imp g.p.m.
feet
MEI 0.40
500 52.5
400
H (feet)
300
200
100
0 100 110 120 130 l/min
6
7
8 m³/h
NPSH (feet)
NPSH (metres)
3
10
P2 (HP)
P2 (kW)
2 5
1
0.5
Power input per stage
0.6
0.4 0.5
0.3
0.4
0.3 0.2
0.2
0.1
0
10
20
30
40
50
60
70
80
90 100 110 120 130 l/min
Flow rate Q 4
TYPE
POWER (P2)
Single-phase Three-phase kW HP
HTm 5/2 – PRO HT 5/2 – PRO 0.75 1
HTm 5/3 – PRO HT 5/3 – PRO 1.1 1.5
HTm 5/4 – PRO HT 5/4 – PRO
1.5
2
HTm 5/5 – PRO HT 5/5 – PRO 1.8 2.5
HTm 5/6 – PRO HT 5/6 – PRO 2.2 3
HT 5/7 – PRO
3
4
HT 5/8 – PRO
3
4
HT 5/9 – PRO
4
5.5
Q = Flow rate H = Total manometric head HS = Suction height
m³/h 0 0.3 0.6 1.2 2.4 3.6 4.8 5.4 6 7.8 1~ 3~ Q l/min 0 5 10 20 40 60 80 90 100 130
35 35 32.7 32.3 32.5 31 25.5 27.5 26 20.5 51.5 51.5 51 50.5 49 46.5 43 41 39 31
68.5 68.5 68 67 65
IE2 IE3 H metres
86 103
85 103
85 102
84 101
81 98
62 57.5 55 52 41 77 72 68.5 65 51.5 93 86 82 78 62
120 120 119 118 114 108 101 96 91 72
137 137 136 134 130 124 115 110 104 82 154 154 153 151 146 139 129 124 117 93
Performance curves comply with EN ISO 9906 Grade 3B tolerance limits.
50 Hz | HT 5 – PRO Start of production 06.2024
HT 8 – PRO
CURVES AND PERFORMANCE DATA HS=0 m
Head H (metres) 4
0
10
0
10
170
160
HT 8/10-PRO
150
140
HT 8/9-PRO
130
HT 8/8-PRO
120
110
HT 8/7-PRO
100
HT 8/6-PRO
90
80
HT 8/5-PRO
70 HT 8/4-PRO
60
50
HT 8/3-PRO
40
30
20
10
0
0
20
40
60
0
1
2
3
4
10
8
6
4
2
0
0.5 Power input per stage
20 20
80
100
5
6
NPSH (metres)
0.4
30
40
30
= 58%
120
140
160
7
8
9
10
P2 (kW)
0.3
0.2
0.1
0
20
40
60
80
100
120
140
160
Flow rate Q 4
50 Hz
50
US g.p.m.
40
Imp g.p.m.
feet
MEI 0.40
500
400 41.7
300
H (feet)
200
100
NPSH (feet)
0
180
200 l/min
11
12
m³/h
30
20
10
0
0.6
0.5
0.4
0.3
0.2
180
200 l/min
P2 (HP)
TYPE
POWER (P2)
Single-phase Three-phase kW HP
HTm 8/3 – PRO HT 8/3 – PRO 1.1 1.5
HTm 8/4 – PRO HT 8/4 – PRO
1.5
2
HTm 8/5 – PRO HT 8/5 – PRO 1.8 2.5
HTm 8/6 – PRO HT 8/6 – PRO 2.2 3
HT 8/7 – PRO
3
4
HT 8/8 – PRO
4
5.5
HT 8/9 – PRO
4
5.5
HT 8/10 – PRO 5.5 7.5
Q = Flow rate H = Total manometric head HS = Suction height
m³/h 0 1.2 2.4 3.6 4.8 6.0 7.2 8.4 9.6 10.8 12.0 1~ 3~ Q l/min 0 20 40 60 80 100 120 140 160 180 200
47 46.5 45.5 44 42 39.5 36.5 32.5 28 23 17
62.5 62 60.5 58.5 56 53 48.5 43.5 37.5 31 23
78 77.5 76 73 70 66 61 54.5 47 38.5 28.5
IE2 IE3 H metres
94 109
93 108
91 106
88 103
84 98
79 92
73 65.5 56.5 46 34.5 85 76 66 54 40
125 124 121 117 112 106 97 87 75 61.5 45.5
141 139 136 132 126 119 109 98 85 69 51.5
156 155 152 147 140 132 122 109 94 77 57
Performance curves comply with EN ISO 9906 Grade 3B tolerance limits.
Start of production 06.2024 HT 8 – PRO | 50 Hz
HT 10 – PRO
CURVES AND PERFORMANCE DATA HS=0 m
50 Hz
H (feet)
Head H (metres) 4
0
10
20
30
40
50
0
10
20
30
40
160
150
140
HT 10/9-PRO
= 62.5%
60
US g.p.m.
50
Imp g.p.m.
feet
MEI 0.40 500
130
HT 10/8-PRO 120
400
110
HT 10/7-PRO
100 HT 10/6-PRO
90
80
HT 10/5-PRO
41.2 300
70
HT 10/4-PRO 60
200
50
HT 10/3-PRO
40
30
100
20
10
0
0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 l/min
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15 m³/h
8
NPSH (feet)
NPSH (metres)
6
20
4 10
2
0
0
0.5
Power input per stage
0.6
0.4 0.5
P2 (HP)
P2 (kW)
0.3
0.4
0.3 0.2
0.2
0.1 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200
210 220 230 240 250 l/min Flow rate Q 4
TYPE
Single-phase Three-phase
HTm 10/3 – PRO HT 10/3 – PRO
HTm 10/4 – PRO HT 10/4 – PRO
HTm 10/5 – PRO HT 10/5 – PRO
HT 10/6 – PRO
HT 10/7 – PRO
HT 10/8 – PRO
HT 10/9 – PRO
POWER (P2)
kW HP
1.5 2
1.8 2.5
2.2
3
3
4
3
4
4 5.5
4 5.5
m³/h 0 1.8 3 3.6 4.8 7.2 9 10.2 12 13.2 15 1~ 3~ Q l/min 0 30 50 60 80 120 150
170 200 220 250
47 45.5 44 43.5 42 38 33.5 30.5 24.7 20.3 13 62 61 59 58 56 50.5 45 40.5 33 27
18 77 75.5 74 73 70 63 56 50.5 41 34 21.5 IE2 IE3 H metres 93 91 88 87 84 76
67.5 61 49.5 40.5 26 108 106 103 102 98 88 79 71 57.5 47.5 30 124 121 118 116
112 101 90 81 66 54.5 34.5 139 136 133 131 126 113 101 91 74 61 38.5
Q = Flow rate H = Total manometric head HS = Suction height
Performance curves comply with EN ISO 9906 Grade 3B tolerance limits.
50 Hz | HT 10 – PRO Start of production 06.2024
HT 15 – PRO
CURVES AND PERFORMANCE DATA HS=0 m
0
25
50
0
25
50
180
HT 15/7-PRO 160
140
HT 15/6-PRO
120
HT 15/5-PRO
75 75
= 62%
50 Hz
100
US g.p.m.
Imp g.p.m. feet
MEI 0.40
500
50
400
H (feet)
Head H (metres) 4
100
HT 15/4-PRO
300
80 HT 15/3-PRO
60
HT 15/3R-PRO
200
40
HT 15/2R-PRO
100
20
NPSH (feet)
NPSH (metres)
00
50
100
0
5
4
3
2
1
1.6 Power input per stage
1.4
1.2
1.0
0.8
0.6
0.4
0
50
100
150
200
250
10
15
150
200
250
Flow rate Q 4
300
350
20
400 25
0 l/min
m³/h
10
5
2
15/3÷7
1.5
15/2R-3R
1
300
350
400
l/min
P2 (HP)
P2 (kW)
TYPE Three-phase
POWER (P2)
m³/h 0
kW HP 3~ Q l/min
0
3
6
12
18
21
24
50
100
200
300
350
400
HT 15/2R – PRO
2.2 3
44
43
41.5
36.5
27.5
20.5
HT 15/3R – PRO
3
4
64.5
62.5
60.5
52.0
37.5
27
HT 15/3 – PRO
4 5.5
72
70
68.5
61
48
38.5
27
HT 15/4 – PRO
5.5 7.5 IE3 H metres 96
94
91
81
64
51.5
36
HT 15/5 – PRO
7.5 10
120
117
114
102
80
64.5
45
HT 15/6 – PRO
9.2 12.5
140
137
133
119
94
75.5
52.5
HT 15/7 – PRO
9.2 12.5
160
155
139
109
88
61.5
Q = Flow rate H = Total manometric head HS = Suction height
Performance curves comply with EN ISO 9906 Grade 3B tolerance limits.
HT 15 – PRO | 50 Hz
HT 30 – PRO
CURVES AND PERFORMANCE DATA HS=0 m
0
50
100
150
0
50
100
180
Head H (metres) 4
160
HT 30/8-PRO
140
HT 30/7-PRO
120
HT 30/6-PRO
100
HT 30/5-PRO
80
HT 30/4-PRO
60
HT 30/3-PRO
40
HT 30/2-PRO
HT 30/2R-PRO 20
= 68%
NPSH (metres)
00
100
200
300
400
500
600
0
10
20
30
5
4
3
2
1
0
1.8 Power input per stage
1.6
1.4
1.2
1.0
0.8
0.6
0
100
200
300
400
500
600
Flow rate Q 4
P2 (kW)
50 Hz
200
US g.p.m.
150
Imp g.p.m.
feet
MEI 0.40
500
400
H (feet)
300
34 200
100
NPSH (feet)
700 40
30/2R
800 50
0 l/min
m³/h 15
10
5
0
2
30/2÷8
1.5
P2 (HP)
1
700
800
l/min
TYPE Three-phase
POWER (P2)
m³/h 0
kW HP 3~ Q l/min 0
6
12
18
24
36
42
48
100 200 300 400 600 700 800
HT 30/2R – PRO
3
4
35
34
33
31
28
17.6
10
HT 30/2 – PRO
4 5.5
40
39
37.5
35
31.5
22
15.7
8
HT 30/3 – PRO
5.5 7.5
60
58.5
56
52.5 47.5
33
23.5
12
HT 30/4 – PRO HT 30/5 – PRO
7.5 9.2
10 12.5
IE3 H metres
80 100
78 98
75 93
70 87
63 79
44
31.3
16
55
39
20
HT 30/6 – PRO
11 15
120
117
112
105
95
66.5
47
24
HT 30/7 – PRO
15 20
137 134 128 120 108
76
53.5 27.5
HT 30/8 – PRO
15 20
158 154 147 138
125
87
62
31.5
Q = Flow rate H = Total manometric head HS = Suction height
Performance curves comply with EN ISO 9906 Grade 3B tolerance limits.
50 Hz | HT 30 – PRO
HT – PRO
ABSORPTION
TYPE
Single-phase
HTm 3/4 – PRO HTm 3/5 – PRO HTm 3/6 – PRO HTm 3/7 – PRO HTm 5/2 – PRO HTm 5/3
– PRO HTm 5/4 – PRO HTm 5/5 – PRO HTm 5/6 – PRO HTm 8/3 – PRO HTm 8/4 – PRO
HTm 8/5 – PRO HTm 8/6 – PRO HTm 10/3 – PRO HTm 10/4 – PRO HTm 10/5 – PRO
VOLTAGE
230 V
7.5 A 9.0 A 10.5 A 12.5 A 6.1 A 8.5 A 10.3 A 12.5 A 13.5 A 8.7 A 10.5 A 12.5 A
14.0 A 9.5 A 11.0 A 13.5 A
TYPE
Three-phase
HT 3/4 – PRO HT 3/5 – PRO HT 3/6 – PRO HT 3/7 – PRO HT 3/8 – PRO HT 3/9 – PRO
HT 3/10 – PRO HT 5/2 – PRO HT 5/3 – PRO HT 5/4 – PRO HT 5/5 – PRO HT 5/6 – PRO
HT 5/7 – PRO HT 5/8 – PRO HT 5/9 – PRO HT 8/3 – PRO HT 8/4 – PRO HT 8/5 – PRO
HT 8/6 – PRO HT 8/7 – PRO HT 8/8 – PRO HT 8/9 – PRO HT 8/10 – PRO HT 10/3 –
PRO HT 10/4 – PRO HT 10/5 – PRO HT 10/6 – PRO HT 10/7 – PRO HT 10/8 – PRO HT
10/9 – PRO HT 15/2R – PRO HT 15/3R – PRO HT 15/3 – PRO HT 15/4 – PRO HT 15/5 –
PRO HT 15/6 – PRO HT 15/7 – PRO HT 30/2R – PRO HT 30/2 – PRO HT 30/3 – PRO HT
30/4 – PRO HT 30/5 – PRO HT 30/6 – PRO HT 30/7 – PRO HT 30/8 – PRO
VOLTAGE
230 V – t 400 V – s 400 V – t 690 V – s
5.2 A
3.0 A
6.1 A
3.5 A
6.9 A
4.0 A
8.3 A
4.8 A
11.2 A 6.5 A
11.8 A 6.8 A
12.1 A
7.0 A
4.9 A
2.8 A
5.5 A
3.2 A
6.6 A
3.8 A
8.3 A
4.8 A
9.0 A
5.2 A
11.8 A 6.8 A
13.0 A 7.5 A
14.7 A 8.5 A
5.7 A
3.3 A
6.9 A
4.0 A
8.3 A
4.8 A
9.3 A
5.4 A
12.1 A 7.0 A
14.7 A 8.5 A
16.4 A 9.5 A
10.5 A 6.1 A
5.9 A
3.4 A
7.8 A
4.5 A
9.0 A
5.2 A
11.2 A 6.5 A
12.5 A 7.2 A
14.4 A 8.3 A
15.6 A 9.0 A
10.4 A 6.0 A
12.5 A 7.2 A
15.2 A 8.8 A
11.2 A 6.5 A
14.2 A 8.2 A
15.0 A 8.7 A
16.5 A 9.5 A
12.1 A 7.0 A
15.2 A 8.8 A
11.2 A 6.5 A
14.1 A 8.2 A
16.5 A 9.5 A
19.0 A 11.0 A
22.0 A 12.7 A
24.5 A 14.2 A
PALLET CAPACITY
TYPE
Single-phase Three-phase
HTm 3/4 – PRO HTm 3/5 – PRO HTm 3/6 – PRO HTm 3/7 – PRO HTm 3/8 – PRO HTm 5/2 – PRO HTm 5/3 – PRO HTm 5/4 – PRO HTm 5/5 – PRO HTm 5/6 – PRO
HT 3/4 – PRO HT 3/5 – PRO HT 3/6 – PRO HT 3/7 – PRO HT 3/8 – PRO HT 3/9 – PRO HT 3/10 – PRO HT 5/2 – PRO HT 5/3 – PRO HT 5/4 – PRO HT 5/5 – PRO HT 5/6 – PRO HT 5/7 – PRO HT 5/8 – PRO HT 5/9 – PRO
HTm 8/3 – PRO HTm 8/4 – PRO HTm 8/5 – PRO HTm 8/6 – PRO
HT 8/3 – PRO HT 8/4 – PRO HT 8/5 – PRO HT 8/6 – PRO HT 8/7 – PRO HT 8/8 – PRO HT 8/9 – PRO HT 8/10 – PRO
HTm 10/3 – PRO HTm 10/4 – PRO HTm 10/5 – PRO
HT 10/3 – PRO HT 10/4 – PRO HT 10/5 – PRO HT 10/6 – PRO HT 10/7 – PRO HT 10/8 – PRO HT 10/9 – PRO
HT 15/2R – PRO
HT 15/3R – PRO
HT 15/3 – PRO
HT 15/4 – PRO
HT 15/5 – PRO
HT 15/6 – PRO
HT 15/7 – PRO
HT 30/2R – PRO
HT 30/2 – PRO
HT 30/3 – PRO
HT 30/4 – PRO
HT 30/5 – PRO
HT 30/6 – PRO
HT 30/7 – PRO
HT 30/8 – PRO
NO. OF PUMPS
12 12 12 12 4 4 4 12 12 12 12 12 4 4 4 12 12 12 12 4 4 4 4 12 12 12 12 4 4 4 4
4 4 4 4 2 2 4 4 4 4 2 2 2 2
HT – PRO | 50 Hz
HT – PRO Technical data
DIMENSIONS AND WEIGHT
FLANGE
h
MADE IN ITALY
PUMP Q
3~ P2
Rel.
l/min H
m
H min
m t max °C
kW-
HP
Hz
min-1 I.CL.
IP
V
V
W2 U2 V2
A
W2 U2 V2
A
U1 V1 W1
U1 V1 W1
120000DIE3
San Bonifacio (VR) ITALY Tel. 045 6136311 www.pedrollo.com
EFFICIENCY CLASS IE3
h1 DN1
a b
c
m
n1
4 fori
d
DN2
Ø hioles
DN K D
TYPE
HT 3 – PRO HT 5 – PRO HT 8 – PRO HT 10 – PRO HT 15 – PRO HT 30 – PRO
DN
D
K
mm mm mm
25 115 85
32 140 100
40 150 110
40 150 110
50 165 125
65 185 145
HOLES N° Ø mm
14
4 18
e
n2
TYPE
PORTS
N°
Single-phase Three-phase DN1 DN2 STAGES a b c
HTm 3/4 – PRO HT 3/4 – PRO
4
HTm 3/5 – PRO HT 3/5 – PRO HTm 3/6 – PRO HT 3/6 – PRO
5 6
126 231
HTm 3/7 – PRO HT 3/7 – PRO 1″ 1″
7
HT 3/8 – PRO
8
HT 3/9 – PRO
9 151 257
HT 3/10 – PRO
10
HTm 5/2 – PRO HT 5/2 – PRO
2
250
HTm 5/3 – PRO HT 5/3 – PRO
3
HTm 5/4 – PRO HT 5/4 – PRO
4 126 231
HTm 5/5 – PRO HT 5/5 HTm 5/6 – PRO HT 5/6
– PRO – PRO
1¼”
1¼”
5 6
HT 5/7 – PRO
7
HT 5/8 – PRO
8 151 257
HT 5/9 – PRO
9
HTm 8/3 – PRO HT 8/3 – PRO
3
HTm 8/4 – PRO HT 8/4 – PRO HTm 8/5 – PRO HT 8/5 – PRO
4 5
126 231
HTm 8/6 – PRO HT 8/6
HT 8/7
– PRO – PRO
1½”
1½”
6 7
HT 8/8 – PRO
HT 8/9 – PRO
8 9
151 257
HT 8/10 – PRO
10
280
HTm 10/3 – PRO HT 10/3 – PRO
3
HTm 10/4 – PRO HT 10/4 – PRO
4 126 231
HTm 10/5 – PRO HT 10/5 – PRO
5
HT 10/6 – PRO 1½” 1½” 6
HT 10/7 – PRO
HT 10/8 – PRO
7 8
151 257
HT 10/9 – PRO
9
HT 15/2R – PRO
2
HT 15/3R – PRO
3
HT 15/3 – PRO
3 151 275
HT 15/4 – PRO 2″ 2″
4
300
HT 15/5 – PRO
5
HT 15/6 – PRO
HT 15/7 – PRO
6 7
181 305
HT 30/2R – PRO
2
HT 30/2 – PRO
HT 30/3 – PRO
2 3
151 275
HT 30/4 – PRO HT 30/5 – PRO
2½”
2½”
4 5
320
HT 30/6 – PRO
HT 30/7 – PRO
6 7
181 305
HT 30/8 – PRO
8
50 Hz | HT – PRO
DIMENSIONS mm
kg
d
e
h h1 n1 n2 m 1~ 3~
509
31.5 31.5
535
31.7 31.7
561
33.0 33.0
607
37.9 37.9
685
45.2
711
46.2
737
47.1
457 75
29.9 29.9
483
30.1 30.1
509
32.1 32.1
555
34.5 34.5
581
35.5 35.5
659
44,3
685
45,3
15
210
711 488
100
180
Ø 13
30.6
49,5 30.6
514
32.6 32.6
560
36.1 36.1
586
36.9 36.9
664
44.6
690
48.7
716
49.7
742 80
54.7
488
30.7 30.7
534
32.7 32.7
560
36.2 36.2
586
44.5
664
44.7
690
48.8
716
49.8
589
52.0
633
52.5
633
57.0
677 90
63.0
771
71.0
900
115.5
944
116.0
18 247 604
130 215 Ø 14 53.5
604
56.5
648
61.5
742 871
105
70.0 123.5
915
124.0
959
136.5
1003
137.0
MATERIALS AND COMPONENTS
1 Pump body 2 Cover
Stainless steel AISI 304,provided with ISO 228/1 threaded ports
8
Stainless steel AISI 304
3 External sleeve
Stainless steel AISI 304
2
4 Impellers
Stainless steel AISI 304
7
6
5 Diffusers
Stainless steel AISI 304
6 Mechanical seal
4
Water pump
Seal
Shaft
Materials
HT 3 – 5 – 8 – 10 PRO
FN-18
Ø 18 mm Graphite / Ceramic / NBR
HT 15 – 30 PRO
FN-KU-24 Ø 24 mm Graphite / Ceramic / NBR
5
ISO 3069 EN 12756
7 Shaft
Stainless steel AISI 316L
8 Electric motor
HTm – PRO: single-phase 230 V – 50 Hz with capacitor and winding integrated thermal
motor protection
3
HT – PRO: three-phase 230/400 V – 50 Hz up to 4 kW 400/690 V – 50 Hz from 5.5 to 15 kW
Pumps are equipped with high-efficiency motors (IEC 60034-30-1) class IE2 for
single-phase models class IE3 for three-phase models
Continuous running duty S1
1
HT – PRO | 50 Hz
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>