PEDROLLO HT-PRO Stainless Steel Multi Stage Centrifugal Pumps User Guide

July 18, 2024
pedrollo

HT-PRO Stainless Steel Multi Stage Centrifugal Pumps

“`html

Specifications:

  • Pump Type: Multi-stage centrifugal pump

  • Material: Stainless steel AISI 304

  • Applications: Clean water, Civil use, Agricultural use,
    Industrial use

  • Electric Motor: Three-phase with IE3 efficiency class,
    Single-phase with IE2 efficiency class

  • Protection: Class F insulation and IPX4 protection

Product Usage Instructions:

1. Installation:

Follow these steps to install the HT-PRO Stainless steel
multi-stage centrifugal pump:

  1. Choose a stable and flat surface for installation.

  2. Connect the pump according to the provided electrical
    specifications.

  3. Ensure proper ventilation around the pump for efficient
    operation.

2. Operation:

To operate the pump:

  1. Turn on the power supply and ensure the pump is primed.

  2. Monitor the pressure and flow rate to ensure optimal
    performance.

  3. Check for any unusual noise or vibrations during
    operation.

3. Maintenance:

Regular maintenance is essential for prolonging the life of the
pump:

  1. Inspect and clean the pump components regularly.

  2. Check for leaks or worn-out parts and replace them as
    needed.

  3. Keep the pump motor well-lubricated for smooth operation.

FAQ:

Q: What are the available requests for the HT-PRO pump?

A: The available requests include:

  • AISI 316 stainless steel pump
  • Handling of liquids with higher or lower temperatures
  • Pump body with NPT threaded ports ANSI B 1.20.1
  • Pump protection kit to prevent dry running
  • O-rings in EPDM or VITON (standard version in NBR)

Q: What are the key features of the HT-PRO pumps?

A: The key features include:

  • High hydraulic performance
  • Robust, compact, and reliable mechanical construction
  • Long service life with low noise operation
  • Stainless steel components for enhanced efficiency

“`

HT-PRO Stainless steel multi-stage centrifugal pumps

Pump entirely made of stainless steel

Clean water Civil use Agricultural use Industrial use

HT-PRO pumps are designed for high hydraulic performance combined with a robust, compact and reliable mechanical construction.
PERFORMANCE RANGE
· Flow rate up to 800 l/min (48 m3/h) · Head up to 160 m
INSTALLATION AND USE Designed to transfer clean water free from abrasive particles and liquids that will not damage the pump’s components. Their high efficiency and adaptability to a wide variety of applications make them an ideal choice in the domestic, civil, agricultural, and industrial sectors, particularly for water distribution along pressure tanks to increase overall network pressure. Suggested uses include fire-fighting systems, heavy-duty cleaning applications, industrial power washers, and irrigation.
KEY FEATURES The multi-stage stainless steel construction guarantees
a long service life and a very low noise threshold during operation. Stainless steel components extend service life and enhance efficiency. Multi-stage design results in exceptionally quiet operation
50 Hz | HT-PRO

Pump body: Stainless steel AISI 304

Cover:

Stainless steel AISI 304

Jacket

Stainless steel AISI 304

Impellers: Stainless steel AISI 304

Diffusers: Stainless steel AISI 304

Shaft

Stainless steel AISI 431

APPLICATION LIMITS
· Manometric suction head up to 7 m · Liquid temperature between -15 °C and +90 °C · Ambient temperature up to +40 °C · Maximum working pressure 16 bar
ELECTRIC MOTOR The three-phase pumps are equipped with newly developed electric motors designed to work with inverters, which guarantee stable and quiet operation. Efficiency class IE3 for three-phase motors and IE2 for single-phase motors, with class F insulation and IPX4 protection.
AVAILABLE UPON REQUEST AISI 316 stainless steel pump Handling of liquids with higher or lower temperatures. Pump body with NPT threaded ports ANSI B 1.20.1 Pump protection kit to prevent dry running O-rings in EPDM or VITON (standard version in NBR) Different voltage requirements 60 Hz frequency

HT 3 – PRO

CURVES AND PERFORMANCE DATA ­ HS=0 m

Head H (metres) 4

0

5

0

5

170

HT 3/10-PRO 160

150 HT 3/9-PRO 140 130 HT 3/8-PRO

120 HT 3/7-PRO
110

100 HT 3/6-PRO

90 HT 3/5-PRO
80

70 HT 3/4-PRO 60

50

40

30

20

10

0

0

10

20

0

1

4

10

30

40

2

10
50 3

15 60

NPSH (metres)

3

2

P2 (kW)

1
0.4 Power input per stage
0.35

0.3

0.25

0.2

0.15

0.1

0

10

20

30

40

50

60

Flow rate Q 4

20 15
= 43%

50 Hz
US g.p.m. 20 Imp g.p.m.
feet
MEI 0.40
500 40.3
400

H (feet)

300

200

100

NPSH (feet)

70 4
70

0

80

90

l/min

5

m³/h

10

5

0.5

0.4

0.3

0.2

80

90

l/min

P2 (HP)

TYPE Single-phase Three-phase

POWER (P2)

m³/h 0

kW HP 1~ 3~ Q l/min 0

0.3 0.6 1.2 2.4 3.6 4.8 5.4 5 10 20 40 60 80 90

HTm 3/4 – PRO HT 3/4 – PRO 0.75 1

65 65 63.5 62 57 50 40.5 35

HTm 3/5 – PRO HT 3/5 – PRO 1.1 1.5

81 80 79 77 71 62.5 51 44

HTm 3/6 – PRO HT 3/6 – PRO

1.5

2

97 96 95 93 86 75 61 52

HTm 3/7 – PRO HT 3/7 – PRO

1.8 2.5 IE2 IE3 H metres 113 112 111 108 100 88 71 61

­

HT 3/8 – PRO 2.2 3

129 128 127 124 114 100 81 69.5

­

HT 3/9 – PRO

3

4

146 144 143 139 129 113 91 78

­

HT 3/10 – PRO 3

4

­ 160 159 155 143 125 102 87

Q = Flow rate H = Total manometric head HS = Suction height

Performance curves comply with EN ISO 9906 Grade 3B tolerance limits.

Start of production 06.2024

HT 3 – PRO | 50 Hz

HT 5 – PRO

CURVES AND PERFORMANCE DATA ­ HS=0 m

Head H (metres) 4

0

0 170

160 HT 5/9-PRO 150

140 HT 5/8-PRO

130 120 HT 5/7-PRO

110 HT 5/6-PRO 100

90 HT 5/5-PRO

80 70 HT 5/4-PRO

60 HT 5/3-PRO
50

40 HT 5/2-PRO 30

20

10

0

0

10 20

0

1

4

10 10

30 40 50

2

3

20 20

60 70 4

80 90 5

30 = 53.5%

50 Hz
US g.p.m. Imp g.p.m.
feet
MEI 0.40
500 52.5

400

H (feet)

300

200

100

0 100 110 120 130 l/min

6

7

8 m³/h

NPSH (feet)

NPSH (metres)

3

10

P2 (HP)

P2 (kW)

2 5

1

0.5

Power input per stage

0.6

0.4 0.5

0.3

0.4

0.3 0.2

0.2

0.1

0

10

20

30

40

50

60

70

80

90 100 110 120 130 l/min

Flow rate Q 4

TYPE

POWER (P2)

Single-phase Three-phase kW HP

HTm 5/2 – PRO HT 5/2 – PRO 0.75 1

HTm 5/3 – PRO HT 5/3 – PRO 1.1 1.5

HTm 5/4 – PRO HT 5/4 – PRO

1.5

2

HTm 5/5 – PRO HT 5/5 – PRO 1.8 2.5

HTm 5/6 – PRO HT 5/6 – PRO 2.2 3

­

HT 5/7 – PRO

3

4

­

HT 5/8 – PRO

3

4

­

HT 5/9 – PRO

4

5.5

Q = Flow rate H = Total manometric head HS = Suction height

m³/h 0 0.3 0.6 1.2 2.4 3.6 4.8 5.4 6 7.8 1~ 3~ Q l/min 0 5 10 20 40 60 80 90 100 130

35 35 32.7 32.3 32.5 31 25.5 27.5 26 20.5 51.5 51.5 51 50.5 49 46.5 43 41 39 31

68.5 68.5 68 67 65

IE2 IE3 H metres

86 103

85 103

85 102

84 101

81 98

62 57.5 55 52 41 77 72 68.5 65 51.5 93 86 82 78 62

120 120 119 118 114 108 101 96 91 72
137 137 136 134 130 124 115 110 104 82 154 154 153 151 146 139 129 124 117 93

Performance curves comply with EN ISO 9906 Grade 3B tolerance limits.

50 Hz | HT 5 – PRO Start of production 06.2024

HT 8 – PRO

CURVES AND PERFORMANCE DATA ­ HS=0 m

Head H (metres) 4

0

10

0

10

170

160

HT 8/10-PRO

150

140

HT 8/9-PRO

130

HT 8/8-PRO

120

110

HT 8/7-PRO

100

HT 8/6-PRO

90

80

HT 8/5-PRO

70 HT 8/4-PRO
60

50

HT 8/3-PRO

40

30

20

10

0

0

20

40

60

0

1

2

3

4

10

8

6

4

2

0
0.5 Power input per stage

20 20

80

100

5

6

NPSH (metres)

0.4

30

40

30

= 58%

120

140

160

7

8

9

10

P2 (kW)

0.3

0.2

0.1

0

20

40

60

80

100

120

140

160

Flow rate Q 4

50 Hz

50

US g.p.m.

40

Imp g.p.m.

feet
MEI 0.40

500

400 41.7
300

H (feet)

200

100

NPSH (feet)

0

180

200 l/min

11

12

m³/h

30

20

10

0

0.6

0.5

0.4

0.3

0.2

180

200 l/min

P2 (HP)

TYPE

POWER (P2)

Single-phase Three-phase kW HP

HTm 8/3 – PRO HT 8/3 – PRO 1.1 1.5

HTm 8/4 – PRO HT 8/4 – PRO

1.5

2

HTm 8/5 – PRO HT 8/5 – PRO 1.8 2.5

HTm 8/6 – PRO HT 8/6 – PRO 2.2 3

­

HT 8/7 – PRO

3

4

­

HT 8/8 – PRO

4

5.5

­

HT 8/9 – PRO

4

5.5

­

HT 8/10 – PRO 5.5 7.5

Q = Flow rate H = Total manometric head HS = Suction height

m³/h 0 1.2 2.4 3.6 4.8 6.0 7.2 8.4 9.6 10.8 12.0 1~ 3~ Q l/min 0 20 40 60 80 100 120 140 160 180 200

47 46.5 45.5 44 42 39.5 36.5 32.5 28 23 17

62.5 62 60.5 58.5 56 53 48.5 43.5 37.5 31 23

78 77.5 76 73 70 66 61 54.5 47 38.5 28.5

IE2 IE3 H metres

94 109

93 108

91 106

88 103

84 98

79 92

73 65.5 56.5 46 34.5 85 76 66 54 40

125 124 121 117 112 106 97 87 75 61.5 45.5

141 139 136 132 126 119 109 98 85 69 51.5

156 155 152 147 140 132 122 109 94 77 57

Performance curves comply with EN ISO 9906 Grade 3B tolerance limits.

Start of production 06.2024 HT 8 – PRO | 50 Hz

HT 10 – PRO

CURVES AND PERFORMANCE DATA ­ HS=0 m

50 Hz

H (feet)

Head H (metres) 4

0

10

20

30

40

50

0

10

20

30

40

160

150

140

HT 10/9-PRO

= 62.5%

60

US g.p.m.

50

Imp g.p.m.

feet
MEI 0.40 500

130

HT 10/8-PRO 120

400

110

HT 10/7-PRO

100 HT 10/6-PRO
90

80

HT 10/5-PRO

41.2 300

70

HT 10/4-PRO 60

200

50

HT 10/3-PRO

40

30

100

20

10

0

0

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 l/min

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15 m³/h

8

NPSH (feet)

NPSH (metres)

6

20

4 10
2

0

0

0.5

Power input per stage

0.6

0.4 0.5

P2 (HP)

P2 (kW)

0.3

0.4

0.3 0.2
0.2
0.1 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 l/min Flow rate Q 4

TYPE

Single-phase Three-phase

HTm 10/3 – PRO HT 10/3 – PRO

HTm 10/4 – PRO HT 10/4 – PRO

HTm 10/5 – PRO HT 10/5 – PRO

­

HT 10/6 – PRO

­

HT 10/7 – PRO

­

HT 10/8 – PRO

­

HT 10/9 – PRO

POWER (P2)

kW HP

1.5 2

1.8 2.5

2.2

3

3

4

3

4

4 5.5

4 5.5

m³/h 0 1.8 3 3.6 4.8 7.2 9 10.2 12 13.2 15 1~ 3~ Q l/min 0 30 50 60 80 120 150 170 200 220 250
47 45.5 44 43.5 42 38 33.5 30.5 24.7 20.3 13 62 61 59 58 56 50.5 45 40.5 33 27 18 77 75.5 74 73 70 63 56 50.5 41 34 21.5 IE2 IE3 H metres 93 91 88 87 84 76 67.5 61 49.5 40.5 26 108 106 103 102 98 88 79 71 57.5 47.5 30 124 121 118 116 112 101 90 81 66 54.5 34.5 139 136 133 131 126 113 101 91 74 61 38.5

Q = Flow rate H = Total manometric head HS = Suction height

Performance curves comply with EN ISO 9906 Grade 3B tolerance limits.

50 Hz | HT 10 – PRO Start of production 06.2024

HT 15 – PRO

CURVES AND PERFORMANCE DATA ­ HS=0 m

0

25

50

0

25

50

180

HT 15/7-PRO 160

140

HT 15/6-PRO

120

HT 15/5-PRO

75 75
= 62%

50 Hz

100

US g.p.m.

Imp g.p.m. feet
MEI 0.40

500

50

400

H (feet)

Head H (metres) 4

100

HT 15/4-PRO

300

80 HT 15/3-PRO

60

HT 15/3R-PRO

200

40

HT 15/2R-PRO

100

20

NPSH (feet)

NPSH (metres)

00

50

100

0

5

4

3

2

1
1.6 Power input per stage
1.4

1.2

1.0

0.8

0.6

0.4

0

50

100

150

200

250

10

15

150

200

250

Flow rate Q 4

300

350

20

400 25

0 l/min
m³/h

10

5

2

15/3÷7

1.5

15/2R-3R

1

300

350

400

l/min

P2 (HP)

P2 (kW)

TYPE Three-phase

POWER (P2)

m³/h 0

kW HP 3~ Q l/min

0

3

6

12

18

21

24

50

100

200

300

350

400

HT 15/2R – PRO

2.2 3

44

43

41.5

36.5

27.5

20.5

HT 15/3R – PRO

3

4

64.5

62.5

60.5

52.0

37.5

27

HT 15/3 – PRO

4 5.5

72

70

68.5

61

48

38.5

27

HT 15/4 – PRO

5.5 7.5 IE3 H metres 96

94

91

81

64

51.5

36

HT 15/5 – PRO

7.5 10

120

117

114

102

80

64.5

45

HT 15/6 – PRO

9.2 12.5

140

137

133

119

94

75.5

52.5

HT 15/7 – PRO

9.2 12.5

­

160

155

139

109

88

61.5

Q = Flow rate H = Total manometric head HS = Suction height

Performance curves comply with EN ISO 9906 Grade 3B tolerance limits.

HT 15 – PRO | 50 Hz

HT 30 – PRO

CURVES AND PERFORMANCE DATA ­ HS=0 m

0

50

100

150

0

50

100

180

Head H (metres) 4

160

HT 30/8-PRO

140

HT 30/7-PRO

120

HT 30/6-PRO

100

HT 30/5-PRO

80

HT 30/4-PRO

60

HT 30/3-PRO

40

HT 30/2-PRO

HT 30/2R-PRO 20

= 68%

NPSH (metres)

00

100

200

300

400

500

600

0

10

20

30

5

4

3

2

1

0
1.8 Power input per stage
1.6

1.4

1.2

1.0

0.8

0.6

0

100

200

300

400

500

600

Flow rate Q 4

P2 (kW)

50 Hz

200

US g.p.m.

150

Imp g.p.m.

feet
MEI 0.40

500

400

H (feet)

300
34 200

100

NPSH (feet)

700 40
30/2R

800 50

0 l/min
m³/h 15

10

5

0

2
30/2÷8

1.5

P2 (HP)

1

700

800

l/min

TYPE Three-phase

POWER (P2)

m³/h 0

kW HP 3~ Q l/min 0

6

12

18

24

36

42

48

100 200 300 400 600 700 800

HT 30/2R – PRO

3

4

35

34

33

31

28

17.6

10

HT 30/2 – PRO

4 5.5

40

39

37.5

35

31.5

22

15.7

8

HT 30/3 – PRO

5.5 7.5

60

58.5

56

52.5 47.5

33

23.5

12

HT 30/4 – PRO HT 30/5 – PRO

7.5 9.2

10 12.5

IE3 H metres

80 100

78 98

75 93

70 87

63 79

44

31.3

16

55

39

20

HT 30/6 – PRO

11 15

120

117

112

105

95

66.5

47

24

HT 30/7 – PRO

15 20

137 134 128 120 108

76

53.5 27.5

HT 30/8 – PRO

15 20

158 154 147 138

125

87

62

31.5

Q = Flow rate H = Total manometric head HS = Suction height

Performance curves comply with EN ISO 9906 Grade 3B tolerance limits.

50 Hz | HT 30 – PRO

HT – PRO

ABSORPTION
TYPE
Single-phase
HTm 3/4 – PRO HTm 3/5 – PRO HTm 3/6 – PRO HTm 3/7 – PRO HTm 5/2 – PRO HTm 5/3 – PRO HTm 5/4 – PRO HTm 5/5 – PRO HTm 5/6 – PRO HTm 8/3 – PRO HTm 8/4 – PRO HTm 8/5 – PRO HTm 8/6 – PRO HTm 10/3 – PRO HTm 10/4 – PRO HTm 10/5 – PRO

VOLTAGE
230 V
7.5 A 9.0 A 10.5 A 12.5 A 6.1 A 8.5 A 10.3 A 12.5 A 13.5 A 8.7 A 10.5 A 12.5 A 14.0 A 9.5 A 11.0 A 13.5 A

TYPE
Three-phase
HT 3/4 – PRO HT 3/5 – PRO HT 3/6 – PRO HT 3/7 – PRO HT 3/8 – PRO HT 3/9 – PRO HT 3/10 – PRO HT 5/2 – PRO HT 5/3 – PRO HT 5/4 – PRO HT 5/5 – PRO HT 5/6 – PRO HT 5/7 – PRO HT 5/8 – PRO HT 5/9 – PRO HT 8/3 – PRO HT 8/4 – PRO HT 8/5 – PRO HT 8/6 – PRO HT 8/7 – PRO HT 8/8 – PRO HT 8/9 – PRO HT 8/10 – PRO HT 10/3 – PRO HT 10/4 – PRO HT 10/5 – PRO HT 10/6 – PRO HT 10/7 – PRO HT 10/8 – PRO HT 10/9 – PRO HT 15/2R – PRO HT 15/3R – PRO HT 15/3 – PRO HT 15/4 – PRO HT 15/5 – PRO HT 15/6 – PRO HT 15/7 – PRO HT 30/2R – PRO HT 30/2 – PRO HT 30/3 – PRO HT 30/4 – PRO HT 30/5 – PRO HT 30/6 – PRO HT 30/7 – PRO HT 30/8 – PRO

VOLTAGE

230 V – t 400 V – s 400 V – t 690 V – s

5.2 A

3.0 A

­

­

6.1 A

3.5 A

­

­

6.9 A

4.0 A

­

­

8.3 A

4.8 A

­

­

11.2 A 6.5 A

­

­

11.8 A 6.8 A

­

­

12.1 A

7.0 A

­

­

4.9 A

2.8 A

­

­

5.5 A

3.2 A

­

­

6.6 A

3.8 A

­

­

8.3 A

4.8 A

­

­

9.0 A

5.2 A

­

­

11.8 A 6.8 A

­

­

13.0 A 7.5 A

­

­

14.7 A 8.5 A

­

­

5.7 A

3.3 A

­

­

6.9 A

4.0 A

­

­

8.3 A

4.8 A

­

­

9.3 A

5.4 A

­

­

12.1 A 7.0 A

­

­

14.7 A 8.5 A

­

­

16.4 A 9.5 A

­

­

­

­

10.5 A 6.1 A

5.9 A

3.4 A

­

­

7.8 A

4.5 A

­

­

9.0 A

5.2 A

­

­

11.2 A 6.5 A

­

­

12.5 A 7.2 A

­

­

14.4 A 8.3 A

­

­

15.6 A 9.0 A

­

­

10.4 A 6.0 A

­

­

12.5 A 7.2 A

­

­

15.2 A 8.8 A

­

­

­

­

11.2 A 6.5 A

­

­

14.2 A 8.2 A

­

­

15.0 A 8.7 A

­

­

16.5 A 9.5 A

12.1 A 7.0 A

­

­

15.2 A 8.8 A

­

­

­

­

11.2 A 6.5 A

­

­

14.1 A 8.2 A

­

­

16.5 A 9.5 A

­

­

19.0 A 11.0 A

­

­

22.0 A 12.7 A

­

­

24.5 A 14.2 A

PALLET CAPACITY

TYPE

Single-phase Three-phase

HTm 3/4 – PRO HTm 3/5 – PRO HTm 3/6 – PRO HTm 3/7 – PRO HTm 3/8 – PRO ­ ­ HTm 5/2 – PRO HTm 5/3 – PRO HTm 5/4 – PRO HTm 5/5 – PRO HTm 5/6 – PRO ­ ­ ­

HT 3/4 – PRO HT 3/5 – PRO HT 3/6 – PRO HT 3/7 – PRO HT 3/8 – PRO HT 3/9 – PRO HT 3/10 – PRO HT 5/2 – PRO HT 5/3 – PRO HT 5/4 – PRO HT 5/5 – PRO HT 5/6 – PRO HT 5/7 – PRO HT 5/8 – PRO HT 5/9 – PRO

HTm 8/3 – PRO HTm 8/4 – PRO HTm 8/5 – PRO HTm 8/6 – PRO ­ ­ ­ ­

HT 8/3 – PRO HT 8/4 – PRO HT 8/5 – PRO HT 8/6 – PRO HT 8/7 – PRO HT 8/8 – PRO HT 8/9 – PRO HT 8/10 – PRO

HTm 10/3 – PRO HTm 10/4 – PRO HTm 10/5 – PRO ­ ­ ­ ­

HT 10/3 – PRO HT 10/4 – PRO HT 10/5 – PRO HT 10/6 – PRO HT 10/7 – PRO HT 10/8 – PRO HT 10/9 – PRO

­

HT 15/2R – PRO

­

HT 15/3R – PRO

­

HT 15/3 – PRO

­

HT 15/4 – PRO

­

HT 15/5 – PRO

­

HT 15/6 – PRO

­

HT 15/7 – PRO

­

HT 30/2R – PRO

­

HT 30/2 – PRO

­

HT 30/3 – PRO

­

HT 30/4 – PRO

­

HT 30/5 – PRO

­

HT 30/6 – PRO

­

HT 30/7 – PRO

­

HT 30/8 – PRO

NO. OF PUMPS
12 12 12 12 4 4 4 12 12 12 12 12 4 4 4 12 12 12 12 4 4 4 4 12 12 12 12 4 4 4 4 4 4 4 4 2 2 4 4 4 4 2 2 2 2

HT – PRO | 50 Hz

HT – PRO Technical data
DIMENSIONS AND WEIGHT

FLANGE

h

MADE IN ITALY

PUMP Q
3~ P2

Rel.

l/min H

m

H min

m t max °C

kW-

HP

Hz

min-1 I.CL.

IP

V

V

W2 U2 V2

A

W2 U2 V2

A

U1 V1 W1

U1 V1 W1

120000DIE3

San Bonifacio (VR) ITALY Tel. 045 6136311 www.pedrollo.com

EFFICIENCY CLASS IE3

h1 DN1

a b

c

m

n1

4 fori

d

DN2

Ø hioles

DN K D

TYPE
HT 3 – PRO HT 5 – PRO HT 8 – PRO HT 10 – PRO HT 15 – PRO HT 30 – PRO

DN

D

K

mm mm mm

25 115 85

32 140 100

40 150 110

40 150 110

50 165 125

65 185 145

HOLES N° Ø mm
14
4 18

e

n2

TYPE

PORTS

Single-phase Three-phase DN1 DN2 STAGES a b c

HTm 3/4 – PRO HT 3/4 – PRO

4

HTm 3/5 – PRO HT 3/5 – PRO HTm 3/6 – PRO HT 3/6 – PRO

5 6

126 231

HTm 3/7 – PRO HT 3/7 – PRO 1″ 1″

7

­

HT 3/8 – PRO

8

­

HT 3/9 – PRO

9 151 257

­

HT 3/10 – PRO

10

HTm 5/2 – PRO HT 5/2 – PRO

2

250

HTm 5/3 – PRO HT 5/3 – PRO

3

HTm 5/4 – PRO HT 5/4 – PRO

4 126 231

HTm 5/5 – PRO HT 5/5 HTm 5/6 – PRO HT 5/6

– PRO – PRO

1¼”

1¼”

5 6

­

HT 5/7 – PRO

7

­

HT 5/8 – PRO

8 151 257

­

HT 5/9 – PRO

9

HTm 8/3 – PRO HT 8/3 – PRO

3

HTm 8/4 – PRO HT 8/4 – PRO HTm 8/5 – PRO HT 8/5 – PRO

4 5

126 231

HTm 8/6 – PRO HT 8/6

­

HT 8/7

– PRO – PRO

1½”

1½”

6 7

­

HT 8/8 – PRO

­

HT 8/9 – PRO

8 9

151 257

­

HT 8/10 – PRO

10

280

HTm 10/3 – PRO HT 10/3 – PRO

3

HTm 10/4 – PRO HT 10/4 – PRO

4 126 231

HTm 10/5 – PRO HT 10/5 – PRO

5

­

HT 10/6 – PRO 1½” 1½” 6

­

HT 10/7 – PRO

­

HT 10/8 – PRO

7 8

151 257

­

HT 10/9 – PRO

9

­

HT 15/2R – PRO

2

­

HT 15/3R – PRO

3

­

HT 15/3 – PRO

3 151 275

­

HT 15/4 – PRO 2″ 2″

4

300

­

HT 15/5 – PRO

5

­

HT 15/6 – PRO

­

HT 15/7 – PRO

6 7

181 305

­

HT 30/2R – PRO

2

­

HT 30/2 – PRO

­

HT 30/3 – PRO

2 3

151 275

­ ­

HT 30/4 – PRO HT 30/5 – PRO

2½”

2½”

4 5

320

­

HT 30/6 – PRO

­

HT 30/7 – PRO

6 7

181 305

­

HT 30/8 – PRO

8

50 Hz | HT – PRO

DIMENSIONS mm

kg

d

e

h h1 n1 n2 m 1~ 3~

509

31.5 31.5

535

31.7 31.7

561

33.0 33.0

607

37.9 37.9

685

­ 45.2

711

­ 46.2

737

­ 47.1

457 75

29.9 29.9

483

30.1 30.1

509

32.1 32.1

555

34.5 34.5

581

35.5 35.5

659

­ 44,3

685

­ 45,3

15

210

711 488

100

180

Ø 13

­ 30.6

49,5 30.6

514

32.6 32.6

560

36.1 36.1

586

36.9 36.9

664

­ 44.6

690

­ 48.7

716

­ 49.7

742 80

­ 54.7

488

30.7 30.7

534

32.7 32.7

560

36.2 36.2

586

­ 44.5

664

­ 44.7

690

­ 48.8

716

­ 49.8

589

­ 52.0

633

­ 52.5

633

­ 57.0

677 90

­ 63.0

771

­ 71.0

900

­ 115.5

944

­ 116.0

18 247 604

130 215 Ø 14 ­ 53.5

604

­ 56.5

648

­ 61.5

742 871

105

­ 70.0 ­ 123.5

915

­ 124.0

959

­ 136.5

1003

­ 137.0

MATERIALS AND COMPONENTS

1 Pump body 2 Cover

Stainless steel AISI 304,provided with ISO 228/1 threaded ports
8
Stainless steel AISI 304

3 External sleeve

Stainless steel AISI 304

2

4 Impellers

Stainless steel AISI 304

7

6

5 Diffusers

Stainless steel AISI 304

6 Mechanical seal

4

Water pump

Seal

Shaft

Materials

HT 3 – 5 – 8 – 10 PRO

FN-18

Ø 18 mm Graphite / Ceramic / NBR

HT 15 – 30 PRO

FN-KU-24 Ø 24 mm Graphite / Ceramic / NBR

5

ISO 3069 EN 12756

7 Shaft

Stainless steel AISI 316L

8 Electric motor

­ HTm – PRO: single-phase 230 V – 50 Hz with capacitor and winding integrated thermal

motor protection

3

­ HT – PRO: three-phase 230/400 V – 50 Hz up to 4 kW 400/690 V – 50 Hz from 5.5 to 15 kW

Pumps are equipped with high-efficiency motors (IEC 60034-30-1) class IE2 for single-phase models class IE3 for three-phase models
Continuous running duty S1

1

HT – PRO | 50 Hz

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals