Use and care manual. Important safeguards. This product is for domestic use only.
Dear Customer:
Dear users (customer), this manual contains the product’s basic knowledge, use instruction, fault diagnosis and basic trouble shooting methods. In order to better understand and use this product, please take good care of this manual and read it carefully.
Important safety instructions
- The range of operating voltage: 97V~130V. In order to avoid damaging the electrical performance of the compressor, please equip with a voltage stabilizer appliance of power not less than 500W, to protect the cooler when the voltage is lower than 97V or higher than130V.
- Individual single-phase socket must be used. It should be reliably connected to a grounding wire. Caution: The grounding wire is not allowed to connect to a water pipe or a gas pipe.
- Strong base, strong acid, organic solvent and corrosive goods or those are easy to pollute to food are prohibited storing in the cooler; otherwise, it can cause corrosiveness oraccident.
- Don’t raise the cooler or the shell of the electric parts, or it will cause the decline in insulation and cause corrosion.
- When the cooler will be not be used for a long time, disconnect the power and clean it. Please examine the circuit whether it is ok before reuse.
- If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.
- The appliance shall be disconnected from its power source during cleaning or maintenance and when replacing parts.
- The A-weighted emission sound pressure level is below 60dB(A).
- Do not store explosive substances such as aerosol cans with a flammable propellant inside the appliance.
- Flammable blowing gas of the cooler should be handled according to local regulations. Before you scrap the appliance, please take off the doors to prevent children trapped.
Caution:
- Risk of fire / flammable materials, taking care to avoid causing a fire by igniting flammable material.
- Keep clear of obstruction all ventilation openings in the appliance enclosure or in the structure for building-in.
- Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.
- Do not damage the refrigerant circuit.
- Do not use electrical appliances inside the food storage compartments of the appliance, unless they are of the type recommended by the manufacturer.
- The ambient temperature and humidity conditions of the cooler climate class following the tab below:
Test room climate class| Dry bulb temperature (° C)| Relative Humidity (%)| Dew point ( °C)|
Water vapor mass in dry air (g/kg)
---|---|---|---|---
0| 20| 50| 9.3| 7.3
1| 16| 80| 12.6| 9.1
8| 23.9| 55| 14.3| 10.2
2| 22| 65| 15.2| 10.8
3| 25| 60| 16.7| 12.0
4| 30| 55| 20.0| 14.8
6| 27| 75| 21.1| 15.8
5| 40| 40| 23.9| 18.8
7| 35| 75| 30.0| 27.3
NOTE: the water vapor mass in dry air is one of the main points
influencing the performance and the energy consumption of the coolers.
Therefore, the order of the climate class in the table is based on the water
vapor mass column.
Refrigerant class A3 per ANSI/ASHRAE 34
Transportation and Placement
Transportation:
- Take out packing and clean all the cabinet using warm water together with 5% of neutral soap then dry it with a soft-cloth; for the glass parts only use specific products, avoiding the use of water which can leave on the glass limestone residues.
- Keep a distance from the wall of 10 cm at least. Please level the unit by settling the adjustable feet.
- Cabinet must be installed on a perfectly even surface, far away from any heat source included sun ray.
- Do not install the unit in open places and do not expose it to rain.
Note: schematic diagram for demand size of product space
Choosing the installation location:
The unit is for indoor application only.
Due to the fact that the unit has a glass door, its performance is highly
influenced by environmental conditions. To minimize the environmental effects
on the unit’s performance, the following are recommended:
- The unit is not to be placed near any kind of heat source
- The unit is not to be placed near or inside air streams produced by ventilation fans, open doors and/ or windows
- The unit is not to be situated under a roof-mounted ventilation system.
- The unit should have sufficient space to ‘breathe’ (always use the rear space to ensure minimum clearance).
- The unit should not be placed under direct sunlight.
- Keep all ventilation openings in the appliance enclosure or in the structure clear of obstruction.
- In order to reduce fire hazard, the installation of this appliance must be carried out only by a suitably qualified person.
Levelling the unit :
Place the unit at the chosen location. Using a spirit level, check whether the
unit is levelled in both directions.
The spirit level can be placed on one of the shelves.
It is essential that the unit is levelled during operation so as to avoid
possible ice formation on the evaporator’s fins due to insufficient drainage
of the condensates. Tilt unit by 2° angle for easy closing of door and drain.
- Do not insert cream or spray bottles inside the cooler.
- Do not store explosive substances such as aerosol cans with flammable propellant in thecooler.
Product Features
- It uses quality, effective and hermetic compressor with broad range of starting voltage, suitable ambient temperature: not higher than 40℃, reasonable matching of the cooler system guarantees its powerful refrigerating ability and energy saving.
- Goods stored can be displayed clearly through the door made of luxurious hollowglass.
- The thermal insulation layer of the cooler made from hard polyurethane foamed plastics makes it be light and good ability to keep the contents cold.
Installation accessories
Shelf installation
A. Hook shelf clips onto clip hanger
B. Place shelves on shelf clips making sure all corners are seated properly
C. Hook the plastic frame of price tag on shelves
Remove the glass door bracket from the door before use
Operation of the Temperature controller
To display or set the temperature, proceed as follows:
- Press SET for 1s, the set value will start flashing ;
- Increase or decrease the value by per click ;
- Press the SET button again to confirm the new value.
Electrical Connection
Electronic diagram(PRN165DX,PRN185DX,PRN210DX,PRN290DX)
Electronic diagram(PRN2110DX)
WARNING
-
Do not, under any circumstances, cut or remove the third ground prong from the powercord supplied.
This appliance is not designed to be used with an inverter.
The cord should be secured behind the appliance and not left exposed or dangling to prevent accidental injury. -
Never unplug the cooler by pulling the power cord. Always grip the plug firmly and pull straight out from the receptacle.
-
Do not use an extension cord with this appliance. If the power cord is too short, have a qualified electrician or service technician install an outlet near the appliance. Use of an extension cord can negatively affect the performance of the unit.
-
Improper use of the grounded plug can result in the risk of electrical shock. If the power cord is damaged, have it replaced by an authorized service center.
Caution for Safety
Warning! Do not damage the refrigerant circuit
Warning! Do not damage walls of the machine: the cooling fluid circuit may
damage
Warning! Do not use electrical appliances inside the food storage
compartments of the appliance, unless they are of the type recommended by the
manufacturer.
Warning! The equipment must not be used by persons (including children)
whose physical, sensorial, or mental capacities are reduced, or who lack
experience and know-how, unless they have been provided, by means of a person
responsible for their safety, with suitable monitoring or instructions about
the use of the equipment. Children must be monitored to ensure they do not
play with the equipment.
Warning! Keep clear of obstruction all ventilation openings in the
appliance enclosure or in the structure for building-in
Warning! The appliance shall be installed in accordance with national
wiring regulations.
Warning! Do not use means to accelerate the defrosting process or to
clean, other than those recommended by the manufacturer.
Warning! The appliance shall be stored in a well-ventilated area where the
room size corresponds to the room area as specified for operation.
Warning! The appliance shall be stored in a room without continuously
operating open flames (for example an operating gas appliance) and ignition
sources (for example an operating electric heater).
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.
Warning! The appliance shall be stored so as to prevent mechanical damage
from occurring.
Warning! Keep ventilation openings, in the appliance enclosure or in the
built-in structure, clear of obstruction.
Notice! Any person who is involved with working on or breaking into a
refrigerant circuit should hold a current valid certificate from an industry-
accredited assessment authority, which authorizes their competence to handle
refrigerants safely in accordance with an industry recognized assessment
specification.
Notice! Servicing shall only be performed as recommended by the equipment
manufacturer.
Maintenance and repair requiring the assistance of other skilled personnel
shall be carried out under the supervision of the person competent in the use
of flammable refrigerants.
Notice! Component parts shall be replaced with like components so as to
minimize the risk of possible ignition due to incorrect parts. The appliance
is to be installed in accordance with the Safety
Notice! Any person who is involved with working on or breaking into a
refrigerant circuit should hold a current valid certificate from an industry-
accredited assessment authority, which authorizes their competence to handle
refrigerants safely in accordance with an industry recognized assessment
specification.
Notice! Servicing shall only be performed as recommended by the equipment
manufacturer.
Maintenance and repair requiring the assistance of other skilled personnel
shall be carried out under the supervision of the person competent in the use
of flammable refrigerants.
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the
appliance.
Cleaning and user maintenance shall not be made by children without
supervision.
Please according to local regulations regarding disposal of the appliance for
its flammable blowing gas. Before you scrap the appliance, please take off the
doors to prevent children trapped.
If the supply cord is damaged, it must be replaced by the manufacturer or its
service agent or a similarly qualified person in order to avoid a hazard.
Please according to local regulations regarding disposal of the appliance for
its flammable blowing gas. Before you scrap the appliance, please take off the
doors to prevent children trapped.
This appliance is intended to be used in household and similar applications
such as – staff kitchen areas in shops, offices and other working
environments;
– farm houses and by clients in hotels, motels and other residential type
environments;
– Catering and similar non-retail applications.
The appliance shall not be installed in public corridors or lobbies.
The appliance is to be installed in accordance with the Safety Standard for
Refrigeration Systems, ANS\/ASHRAE 15.
Check that cabling will not be subject to wear, corrosion, excessive pressure,
vibration, sharp edges, or any other adverse environmental effects. The check
shall also take into account the effects of aging or continual vibration from
sources such as compressors or fans.
Before carrying out Decommissioning procedure, it is essential that the
technician is completely familiar with the equipment and all its detail. It is
recommended good practice that all refrigerants are recovered safely. Prior to
the task being carried out, an oil and refrigerant sample shall be taken in
case analysis is required prior to re-use of recovered refrigerant. It is
essential that electrical power is available before the task is commenced.
When removing refrigerant from a system, either for servicing or
decommissioning, it is recommended good practice that all refrigerants are
removed safely.
The recovery equipment shall be in good working order with a set of
instructions concerning the equipment that is at hand and shall be suitable
for the recovery of all appropriate refrigerants including, when applicable,
FLAMMABLE REFRIGERANTS
The recovered refrigerant shall be returned to the refrigerant supplier in the
correct recovery cylinder, and the relevant waste transfer note arranged. Do
not mix refrigerants in recovery units and especially not in cylinders
The maximum loading of each type of shelf is 30kg.
All maintenance staff and others working in the local area shall be instructed
on the nature of work being carried out. Work in confined spaces shall be
avoided.
If any hot work is to be conducted on the refrigerating equipment or any
associated parts, appropriate fire extinguishing equipment shall be available
on hand. A dry chemical or CO2 fire extinguisher should be adjacent to the
charging area.
No person carrying out work in relation to a REFRIGERATING SYSTEM which
involves exposing any pipe work shall use any sources of ignition in such a
manner that it may lead to the risk of fire or explosion. All possible
ignition sources, including cigarette smoking, should be kept sufficiently far
away from the site of installation, repairing, removing and disposal, during
which refrigerant can possibly be released to the surrounding space. Prior to
work taking pl ace, the area around the equipment shall be surveyed to make
sure that there are no flammable hazards or ignition risks. “No Smoking” signs
shall be displayed.
Checking for presence of refrigerant, The area shall be checked with an
appropriate refrigerant detector prior to and during work, to ensure the
technician is aware of potentially toxic or flammable atmospheres. Ensure that
the leak detection equipment being used is suitable for use with all
applicable refrigerants, i.e., no spark, adequately sealed, or intrinsically
safe.
Ensure that the area is in the open or that it is adequately ventilated before
breaking into the system or conducting any hot work. A degree of ventilation
shall continue during the period that the work is carried out. The ventilation
should safely disperse any released refrigerant and preferably expel it
externally into the atmosphere.
Where electrical components are being changed, they shall be fit for the
purpose and to the correct specification. At all times, the manufacturer’s
maintenance and service guidelines shall be followed. If in doubt, consult the
manufacturer’s technical department for assistance.
Detection of flammable refrigerants: Under no circumstances shall potential
sources of ignition be used in the searching for or detection of refrigerant
leaks. A halide torch (or any other detector using a naked flame) shall not be
used.
Caution for Using
- Unpack all packages before using the cooler. Don’t slant it over more than 60°, while moving it.
- When initial operation, the cooler should run emptily about two hours before storing food in it.
- The control button could adjust the temperature inside the cooler. Generally, the temperature setting of 5℃ is appropriate
- To save energy, the door should not be frequently opened or left open for a long time.
- The surface and the inside of the cooler should be dry and clean. Long termmoisture will cause the cooler rust slowly. (There will be some stains on the surface.)
- Periodical cleaning is suggested for your reference. Generally, 30-45 days once is the best. When cleaning, it is best to wipe the inside and the surface of the cooler with a soft cloth with neutral soap or detergent.
Caution: To ensure safety, the power plug must be pulled out before cleaning.
Cleaning of the unit
For cleaning the unit’s internal plastic parts, use a light solution of soap
and water. Do not apply hard chemical detergents on the plastics as they may
lose their brightness or even get deformed.
The same applies to the external metallic surfaces. The use of hard chemicals
could harm the painting of the metallic surfaces, thus affecting the sanitary
protection of the unit.
Ordinary Trouble and Remedies:
Please refer to the below trouble shooting lists to overcome any minor problems that occur during operations.
Trouble| Reason| Check| Solution|
Remark
---|---|---|---|---
Lamp not lighting| No voltage| Fuse breaking off| Check fuse| Change fuse|
Ask professional to maintain.
Poor connection between the plug and socket| The connection lease or not|
Repair or change socket
Have voltage| lamp has poor contact or worn down| Check the circuit and lamp|
Tighten the connection or change a new lamp| Ask professional to maintain.
Lamp switch has poor contact| Check the switch| Tighten the connection or
change a new switch
Condenser fan Not running| Compressor works orderly| Condenser fan broken
down| Remove condenser fan| Change condenser fan
Compressor does not work
| Thermostat is not set to the work position| Check the position of the
thermostat knob| Revolve the thermostat knob to the operating position
Thermostat terminal is not connected properly| Check the thermostat terminal|
Reconnect the terminal
Notice: The following are not trouble but common phenomenon:
- Sound, the refrigerant flows inside the cooler.
- Compressor and condenser become hot.
- If the ambient humidity is high, there may be dewdrop on the surface, please use soft and dry cloth to clean in time
Documents / Resources
|
PREMIUM LEVELLA PPN Series Double Door Merchandiser
Refrigerator
[pdf] User Manual
PRN165DX, PRN185DX, PRN210DX, PRN2110DX, PRN290DX, PPN Series Double Door
Merchandiser Refrigerator, PPN Series, PPN Series Merchandiser Refrigerator,
Double Door Merchandiser Refrigerator, Merchandiser Refrigerator, Refrigerator
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>