PREMIUM LEVELLA DF2-11 Mini Fridge Freezer Owner’s Manual
- June 3, 2024
- PREMIUM LEVELLA
Table of Contents
Service manual
Model: DF2-11 PRF316300HS
Product description
BRAND: | Premium Levella |
---|---|
MODEL: | PRF316300HS |
PRODUCT DESCRIPTION: | Mini Bar, glass shelves, crystal crisper, recessed |
handle
Color| Inox
LOADING QTY/40HQ| 274
PRODUCT DIMENSION (WDH mm)| 480500850
PACKING DIMENSION (WDH mm)| 500540885
PRODUCT WEIGHT (Kg):| Gross Weight (G.W)| Net Weight (N.W)
26| 24
Total Gross Capacity (Cu.Ft)| 87
Total Net Capacity (Cu.Ft)| 85
The cooling system
General exploded view
No. | Homa Code | Description of Spare Part | Quantity |
---|---|---|---|
4 | 20122080036 | Door hinge screw cover | 1 |
5 | 20122080091 | Door hinge cover | 1 |
6 | 3031400148 | Upper door hinge | 1 |
7 | 2208101188 | Middle hinge washer | 1 |
8 | 3031400116 | Middle door hinge | 1 |
9 | 3031400067 | Lower door hinge | 1 |
10 | 2100152587 | Upper door | 1 |
10.1 | 3020400145 | Upper door gasket | 1 |
10.2 | 20122090005 | Right Aid Closer Of Upper Door | 1 |
10.3 | 20122090011 | Left Aid Closer Of Upper Door | 1 |
11 | 2100152588 | Lower door | 1 |
11.1 | 3020400146 | Lower door gasket | 1 |
11.2 | 3031500031 | Door joist, straight | 1 |
11.3 | 3031500044 | Door joist, curved | 1 |
11.4 | 3031500011 | Lower door joist | 1 |
11.5 | 20122090162 | Right Aid Closer Of Lower Door | 1 |
11.6 | 20122090179 | Left Aid Closer Of Lower Door | 1 |
12 | 2501100002 | Door switch | 1 |
13 | 20120020226 | Fridge shelf assembly | 1 |
17 | 3031500055 | Bottle rack for drinks | 1 |
18 | 3020500092 | Upper door joist | 1 |
19 | 2207400523 | Crisper drawer assembly | 1 |
20 | 20120030010 | Cover of crisper drawer | 1 |
21 | 3050100117 | Power supply cord | 1 |
22 | 3039900264 | Compressor bracket | 1 |
25 | 20122990039 | Drain pan | 1 |
26 | 3050200095 | Earthing wire of compressor | 1 |
28 | 2400100282 | Compressor | 1 |
29 | 3040500011 | Drier filter | 1 |
30 | 20114070006 | Connecting tube | 1 |
31 | 3040600005 | Process tube | 1 |
32 | 20120010085 | Thermostat controller | 1 |
32.1 | 2400200005 | Thermostat | 1 |
32.11 | 20122010037 | Thermostat Knob | 1 |
32.3 | 2500500002 | Light Bulb | 1 |
32.5 | 20122010002 | Controller Shell | 1 |
32.6 | 20122010048 | Lamp Cover | 1 |
32.7 | 2500600001 | Light Holder | 1 |
42 | 20122990019 | Higher Leveling Foot | 1 |
--- | --- | --- | --- |
44 | 20122990006 | Shorter Leveling Foot | 1 |
300 | 2700501337 | Trademark | 1 |
301 | 2700117929 | Carton | 1 |
Trouble shooting guide
No | Problem | Possible Cause | What To Do |
---|---|---|---|
**** 1 | **** Refrigerator room temperature Ok and compressor running Fan not |
working
Freezer room temperature not enough cold
No air in the freezer air outlets| the fan motor failure| 1-
Open the cover board of the air duct in the freezer room and check the fan
2- If not running, measure the voltage between the red wire and black wire
of fan
3- If the voltage is 12V, the fan motor is failure and replace it with a new
one
the failure of the inner wire to fan connector| 1- Measure the
voltage between the CN2 red and black wire of PCB
2- If the voltage is 12V, check from the inner wire to fan connector
the PCB failure| 1- Measure the voltage between the CN2 red and
black wire of PCB
2- If the voltage is zero, then the PCB failure and change a new PCB
2| No defrost Freezer room temperature is not cold enough Refrigerator room:
duct and ice formation on the evaporator| the drainpipe contains impurity| 1-
Disconnect power, and let the ice melt and inspect the water if it is flowing
through the drain pipe
2- If not, check if there is impurity and clean the drain pipe
the sensor failure or PCB failure| 1- Check the fuse
2- If the fuse is melted, it means that the sensor failure or PCB failure
3- Change the sensor or PC
the defrost heater is broken or PCB failure| 1- Check the CN4 defrost
heater two connector
2- If the heater is OK then is the PCB failure and change the PCB
3| The temperature of the freezer and refrigerator is not cold
enough
The temperature can not be adjusted by the potentiometer (thermostat)|
the potentiometer failure| 1- Inspect the potentiometer (thermostat)
2- Measure the resistance value by adjusting the potentiometer (thermostat)
3- The resistance value is not changed by adjusting the potentiometer
(thermostat)
the sensor failure| 1- If the potentiometer (thermostat) setting
is below 3 degrees, the compressor will be running 20 minutes and then stop 30
minutes
2- If the potentiometer (thermostat) setting is more than 3 degrees, the
compressor will be running 30 minutes and then stop 20 minutes
3- If the compressor works like the above situation, it means the sensor
failure
4-Open the back of the refrigerator and change the sensor of the refrigerator
evaporator
4| LED light is not working| the led failure| 1- Open the refrigerator
door and measure the voltage of CN3 in the PCB
2- If the voltage is zero then it means the connecting wire failure
3- If the voltage is 12V, it means the led failure
---|---|---|---
the switch circuit failure| 1- If the CN3 voltage is not 12V, then
check the CN4 voltage
2- If the CN4 voltage is not changed by closing and opening the door, it
means the switch circuit failure
5| Compressor not start running| no problem| 1- The time between
two starting is shorter than 12min
2- The refrigerator room temperature is lower than the set temperature
3- In this case, it is no problem. Please wait for longer
PCB failure| PCB has automatic self-examination:
1- Open the cover of PCB at the back of the product, plug-in power and push
the SW101, switch 3 seconds and the PCB begin automatic self-examination
program
2- Then the led, compressor, fan and defrost heater will work for two
seconds and then stop and quit the automatic self-examination program. After
that, the program will reset to the original setting.
3- If the automatic self-examination program is not working, it means the
PCB failure and needed to be changed
**** compressor wire failure or compressor damage| 1- Measure the voltage
of compressor input connector
2- If it is OK then check the starting and relay of the compressor
3- Also check the wire if it is OK
6| Not woeking at all| the PCB failure| **** 1- Check the power
by multimeter
2- If the input voltage is 220V-240V, but the led, compressor, fan, and
defrost heater are all not working, it means the PCB failure and needed to be
changed