CLIPSAL Airflow 6500ADS Installation Guide

June 7, 2024
CLIPSAL

CLIPSAL
Airflow®6500ADS
Installation Instructions

Thank you for purchasing this Clipsal Airflow®product.Please install the product carefully, according to these instructions. Airflow®3-in-1 products combine an exhaust fan, light, and gentle heat in one single unit. All functions switch separately from a supplied switch plate.

Safety, Installation and Operating Requirements

RISK OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH

  •  This product must only be installed and serviced by appropriately qualified and/or licensed electrical personnel.
  • Isolate the electrical supply before doing any work on this product.
  • Ensure that the product has been correctly installed and tested for safe operation before reconnecting the electrical supply.
  • The product must be installed so that the switches and other controls cannot be touched by a person in the bath or shower.

Failure to follow these instructions will result in death or serious injury.

WARNING
RISK OF FIRE AND SERIOUS INJURY

  • Do not install the product close to curtains or other combustible materials.
  •  Do not cover the product with insulating or other materials.
  • Only install R125 275 Wheat reflector globes in the heat cavities of the product.
  • Do not install heat reflector globes greater than 275 W in the heat cavities of this product.

Failure to follow these instructions can result in fire and serious injury.

CAUTION
EQUIPMENT OPERATION HAZARDS

  • This product is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction by a person responsible for their safety.
  • Ensure that the switch is in the Off position before changing the center globe or heat reflector globes.
    Failure to follow these instructions can result in injury.

THIS CARD IS ALSO YOUR INSTALLATION TEMPLATE

Installation Steps

  1.  (See A →) Using this card in its open state as a template, position the card in the area of the ceiling where  you want to mount your Airflow ®3-in-1 unit and draw around the edges with a pencil to mark the hole
    cutting size.

  2. (See B →) Use a saw to cut the section along the drawn lines. CLIPSAL Airflow 6500ADS ab

  3.  The lamp surround easily unclips from the main body by lifting gently from any side. Remove the lamp surround and heat reflector globes to avoid damage from knocks and vibrations.

  4.  (Optional) Fit the back draught shutter to the top of the Airflow ® 3-in-1 unit. If required, screw the shutter into place in three positions around the perimeter with self-drilling screws.

  5.  (See C →) Pull both side springs inward so that the Airflow ® 3-in-1 unit can pass through the hole without damaging the plaster, then insert the Airflow ® 3-in-1  unit through the hole.CLIPSAL Airflow 6500ADS CD

  6.  Once the Airflow® 3 in1 unit is in position, return the side springs to their original position to support the Airflow ® 3-in-1  unit in the ceiling.
    Note: Springs are adjusted to suit either a 10 mm or 13 mm plasterboard ceiling.

  7.  (See D →) Clip the lamp surround back onto the body, making sure that both clips snap into place.

  8.  (See E →) Screw the center globe into place. The lamp surround has been shaped to position the heat reflector globes correctly in the main body.CLIPSAL Airflow 6500ADS E

  9.  Screw the four large heat reflector globes through the lamp surround holes, tightening firmly to ensure a
    good electrical contact.

Wiring

CLIPSAL Airflow 6500ADS Wiring

  1.  Decide the best position for the switch plate, then set and mount it. Make sure to click the switches into the backing plate in the desired order.
  2.  Connect wiring to switches as shown in the diagram above.
  3.  Remove the screws from the electrical terminal cover on the Airflow®3-in-1 unit and put them aside.  Wire according to the table beside the terminal strip. Remove a knockout in the terminal cover to prevent fouling of the incoming cable when the cover is fitted. Replace the cover and cover screws.
  4.  Check that power is switched on and that all switches activate properly according to their marked function.

CAUTION
CLEANING HAZARD

  • Ensure that the product is switched off before cleaning.
  • Remove heat reflector globes when they are at room temperature. Wipe with a damp cloth. Never immerse the globes in liquid.
  •  Always use a soft, non-abrasive cloth to clean the product.
  • Regularly clean away excess fluff from inside the body, motor, blades and brackets.

Failure to follow these instructions can result in injury and equipment damage.

NOTICE
USAGE HAZARD

  •  Do not install the product directly over baths or showers or in areas subject to direct splashing.
  •  Do not leave heat globes on for extended periods of time. For applications where the heat globes may be left on for longer than 20 minutes, it is recommended to install a separate timer to automatically switch off the heat globes.
  • The product should not be covered or installed in locations that restrict natural ventilation for cooling purposes.
  • Ensure that the product grille is kept free of objects, dust build-up and other matter that may restrict airflow.

Failure to follow these instructions can result in equipment damage or a reduced lifespan of components.

NOTICE
INSTALLATION HAZARD

  •  This product is designed specifically for cavity-type ceilings.
  •  It is NOT recommended to install this product in flat-roof, raked or cathedral ceilings.
  • The heat globes are not designed to heat entire rooms, but rather apply instant, concentrated heat to persons standing directly below the product.
  • It is recommended that the ceiling space is adequately ventilated to allow appropriate airflow through the unit. Any restrictions on return air entering the room or exhausted air escaping from the ceiling space will impair the effectiveness and may contribute to premature failure.
  • A minimum of 500 mm clearance is required above the ceiling where the product is to be installed.
  • A minimum of 100 mm clearance is required between the installation location and any ducting in the ceiling space.
  • Regulations regarding the discharge of air must be complied with.
  • Joists, beams, and rafters must not be cut or notched to install the product.

Failure to follow these instructions can result in reduced product performance or equipment damage.

NOTICE
CORRECT INSTALLATION

  • Failure to position the lamp surround correctly may cause the heat reflector globes to touch the main body and cause warping.
  • The product’s centre cavity is designed to accept only R63 8 W LED reflector globes.
  •  Only install R63 8 W LED reflector globes in the centre cavity. Do not install any other type of globe as this may cause overheating and subsequent warping of the body.
  • The heat cavities have been designed to accept only R125 275 W LED reflector globes. Do not install heat reflector globes greater than 275 W.
  • Do not force or over-tighten globes.

Failure to follow these instructions can result in equipment damage.

Spare Parts

  •  Electrical switches supplied with your Airflow ® 3-in-1 are usually available from any electrical wholesaler.
  • Centre Globe: The centre globe can only be replaced with an R63 8 W LED reflector globe.
  •  Heat Globes: The heat globes can only be replaced with R125 275 W heat reflector globes.

Technical Information

Voltage 230–240 V a.c. 50 Hz only
Fan Wattage 27 W
Fan Max. Air Movement 338 m3/hr(290 m3/hr with draught shutter added)

Schneider Electric reserves the right to change specifications, modify designs and discontinue items without incurring obligation, and whilst every effort is made to ensure that descriptions, specifications and other information in this catalog are correct, no warranty is given in respect thereof and the Company shall not be liable for any error therein.
© Schneider Electric 2017
This material is copyright under Australian and international laws. Except as permitted under the relevant
law,no part of this work may be reproduced by any process without prior written permission of and acknowledgment to Schneider Electric. Schneider Electric acknowledges that the Australian Standard  Certified Product logo is a trademark of SAI Global.

For full warranty details see:
www.clipsal.com/warranty
Australia
Schneider Electric (Australia) Pty Ltd
Customer Care Australia: 1300 369 233
customercare.au@schneider-electric.com
www.schneider-electric.com.au
New Zealand
Schneider Electric (NZ) Ltd
Customer Care: 0800 652 999
sales@nz.schneider-electric.com
www.schneider-electric.com

References