CLIPSAL 41EPBDWCLM-VW Push Button Wiser Smart Dimmer Mechanism Instruction Manual

June 6, 2024
CLIPSAL

**CLIPSAL 41EPBDWCLM-VW Push Button Wiser Smart Dimmer Mechanism Instruction Manual

**

Iconic® Connected Module

  1. Follow the installation instructions
    To change default device settings:

  2.  Download the Wiser™ by SE App

  3. Connect the Iconic device

  4. Configure the Iconic device

Works with

For your safety

DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH

  • It is illegal for persons other than an appropriately licensed electrical contractors or other persons authorised by legislation to work on the fixed wiring of any electrical installation.
  • To comply with all safety standards, the device must be used only for the purpose described in this instruction and must be installed in accordance with the wiring rules and regulation in the location where it is installed.
  • Lock out and tag the input circuit before accessing the wiring connections.
  • The Locking Bar on the grids must be set to the Closed position to ensure that the device cannot be removed during normal operation.
  • There are no user serviceable parts inside the device. Failure to follow these instructions will result in death or serious injury.

CAUTION
EQUIPMENT DAMAGE HAZARD

  • Install the device according to instructions in this document.
  • Pay attention to the specifications and wiring diagrams related to the installation.
  • Do not use the device for any other purpose than specified in this instruction.
  • Dropping the device may damage the internal components. Check that the device operates after being dropped or if physical damage is shown.
    Failure to follow these instructions can result in injury or equipment damage.

NOTICE
EQUIPMENT DAMAGE HAZARD (LOAD AND OPERATION)

  • Operation of the device at elevated temperatures or voltages outside of specification (240 V a.c. and 25 °C) may cause the over-temperature protection circuitry to operate. Operating with significant overload may activate thermal shut-down. In extreme cases, the thermal fuse may blow and render the device inoperable.
  • Reduce the size of the connected load or use a different brand of lamp to prevent recurrence.
  • Do not operate the product for prolonged periods in extreme conditions.
    Failure to follow these instructions can result in equipment damage.

NOTICE
MAXIMUM LOAD RATINGS APPLY
Ensure that the number of low voltage lighting transformers connected to a single device does not exceed the maximum load rating of the device.
Failure to follow these instructions can result in equipment damage.

Installation

**Multi-gang orientation

**

When installing in a 3-gang plate, the middle module must face the opposite way to the other 2 modules.
The maximum load rating of each module must be derated (see Derating section).

  • Mounting the grid

  • Wall box depth

  • Module dimensions

Fitting the module to the grid

Cabling and connections

(Typical 3-way installation using Iconic Connected Module)
Note: ControlLink Modules work with the Connected Dimmer out-of-the-box.

Notes

  • Up to 5-way dimming (e.g. 1x Dimmer plus up to 4x ControlLink Modules, or up to 3x Dimmers plus 2x ControlLink Modules).

  • All Active connections must be on the same phase.
    In case of multiple Dimmers being installed, each Dimmer must be connected to a separate load.

  • Total length of CTL and Active loop: max. 50 m.

  • Control and load cables must not be coupled.

Derating

For multi-gang applications, derate the maximum load rating of each module as shown in the table below. The load figures are based on a nominal voltage of 220‑240 V a.c.

Primary modules per plate Max. load per primary module
1 300 W
2 225 W 3
3 150 W

Retrofit (2-way installation shown)

**NNZ58569

**

Configuring the module (optional)

General information

This product operates as a dimmer ‘out-of-the-box’, with no configuration needed.
The module can optionally be configured as a delay timer, and features a scheduler function. The module LED indicator behaviour and max./min. brightness levels can also be configured, if desired.
Note: The module must be paired with a mobile phone and the Wiser™ by SE App in order to perform these tasks.

Pairing

Note: When pairing the module with the Wiser by SE App, be in the same room and within a range of 8 to 10 m of the module. Range can be affected by walls and other structures.

  1. Install the Wiser by SE App on your mobile phone and register an account

  2. Tap Add Device in the Home page and select the module.

  3. Follow the animated instruction to pair the module.

  4. Module is paired to the App and displayed in the Home page.

Setting the LED indicator behaviour

  1. Tap the module in the Home page.

  2. Tap Settings in the module’s device page.

  3. Tap LED indicator settings in the device setting page.

  4. Tap the desired behaviour in the list (default behaviour: On when load is Off)

Setting the max./min. brightness levels

  1. Tap Settings in the module’s device page.

  2. Tap Dimming range in the device setting page and adjust the max. and min. brightness levels.

Setting the mode

  1. Tap Settings in the module’s device page.

  2. Tap Mode in the device setting page and choose a mode.

Switch
Timer feature is disabled.
Delay timer
When the load is switched On, the load is automatically switched Off when the timer interval expires.
(Example application: pantry light)
Note: If a delay timer is running when a scheduler event (switch On or switch Off) is actioned, the delay timer is cancelled.

Setting the timer interval

  1. Tap the timer display in the module’s device page.

  2. Select a time interval from the available options, then tap Confirm.

Setting the scheduler

Tap Schedule in the module’s device page and follow the steps in the App.

Restoring the device to factory defaults

Note: All customised settings and Bluetooth pairing information will be lost. Before restoring, remove the skin in order to see the module LED indicator.

Preparing the device for use with Wiser Hub
This module can be used as a device in a Wiser Hub network. The module must first be changed from BLE mode to Zigbee mode.

For information on using the module with the Wiser Hub, refer to the Wiser System User Guide.

IMPORTANT: This operation will result in some data loss and the device needs to be re‑configured after the mode has been changed successfully. For further details, please contact customer support.

Technical data

Note: See product datasheet for full specifications.

Operating voltage 220-240 V a.c., 50 Hz
Load rating No minimum load required

Max. 300 W
Refer to Load Compatibility table
Load connection| LED indicator flashes in the event of load disconnection or failure
Dimming range| Min. 0%, Max. 100% (depending on load)
Protection| Over temperature: Yes
Short circuit: Yes
Overcurrent/thermal fuse: Yes
LED indicator| Yes
Multiway control| Yes, via ControlLink
Multiway limits| Max. 5-way dimming
(Max. 3 Iconic Connected Dimmers + remainder ControlLink Modules.)
ControlLink/Active cable limit| Total length of CTL and Active loop: max. 50 m
Supported protocols| BLE (default), Zigbee
Compatible plate ranges| Iconic, Iconic Styl, Iconic Essence, Pro Series
Mounting centres| 84 mm pattern plate
Compliance| Safety: AS/NZS 60669.2.1
EMC: AS/NZS 60669.2.1
RF: AS/NZS 4268
Power failure data retention| Internal date/time retained for at least 6 hrs. Settings preserved indefinitely.
Environmental rating| IP20 (designed for indoor use only)
Operating humidity| 5%-90% RH, non-condensing

Specifications typical at 25 °C

Load compatibility

Dimmable LED 150 W
Dimmable compact fluorescent 300 W

240 V incandescent/halogen
LV halogen with electronic transformer
Non-dimmable LED| Not compatible
Non-dimmable compact fluorescent

Disclaimer

Schneider Electric reserves the right to change specifications, modify designs and discontinue items without incurring obligation and whilst every effort is made to ensure that descriptions, specifications and other information in these instructions are correct, no warranty is given in respect thereof and the company shall not be liable for any error therein.

© Schneider Electric 2020
This material is copyright under Australian, New Zealand and international laws. Except as permitted under the relevant law, no part of this work may be reproduced by any process without prior written permission of and acknowledgment to Schneider Electric.
Android is a trademark of Google Inc.

Apple is a trademark of Apple Inc., registered in the U.S. and other countries. Wiser™ is a trademark and the property of Schneider Electric SE, its subsidiaries and affiliated companies.
Zigbee® is a registered trademark of the Zigbee Alliance.

Customer care

Warranty information

We warrant this product for 2 years. See Warranty links below.
Schneider Electric (Australia) Pty Ltd
33-37 Port Wakefield Road, Gepps Cross SA 5094
Customer Care: 13 73 28
Email: [email protected]
Warranty:
https://www.se.com/au/en/about-us/legal/terms-and-conditions.jsp
www.se.com
Schneider Electric (NZ) Ltd
Building 6, 60 Highbrook Drive, East Tamaki, Auckland 2013
Customer Care: 0800 652 999
Email: [email protected]
Warranty: https://www.se.com/nz/en/about-us/legal/terms-and- conditions.jsp
www.se.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals