FOAMit SS2 Series Air Powered Footwear Sanitizing Unit Instruction Manual

July 15, 2024
FOAMit

FOAMit SS2 Series Air Powered Footwear Sanitizing Unit

Product Information

Specifications

  • Model: SS2
  • Designed for use with fully protective footwear
  • Intended for sanitizing shoe soles at transition zones with reduced moisture focus
  • Not suitable for any other use

Product Usage Instructions

Safety Precautions
It is crucial to adhere to the following safety guidelines:

  • Always wear appropriate Personal Protective Equipment (PPE) as indicated in the Safety Data Sheet (SDS).
  • Avoid contact of chemical solutions with skin, eyes, or inhalation.
  • Disconnect the air line before performing maintenance and clean the unit after each use.
  • Do not operate the unit if damaged or leaking.
  • Avoid using hydrocarbons or flammable products with the unit.

Usage Instructions

  1. Ensure full foot insertion into the unit and press down with the heel to prevent chemical spray to face and eyes.
  2. Wear splash goggles as directed by the chemical manufacturer, SDS, or OSHA.
  3. Only use fully protective footwear with the unit.
  4. Read and follow all chemical safety precautions and handling instructions provided by the manufacturer before using the unit.
  5. Dispose of packaging materials, old machine components, and hazardous fluids in an environmentally safe way.

Daily Maintenance
To ensure proper operation, perform the following daily maintenance procedures:

  • Be cautious of fluid levels not reaching above the manifold during heavy use to prevent improper operation.

FAQ

  • Q: What type of footwear is suitable for use with the SS2 unit?
    A: The SS2 unit is designed for use with fully protective footwear only. Ensure your footwear meets this requirement before using the unit.

  • Q: How should I protect myself from chemical exposure while using the unit?
    A: Always wear the appropriate Personal Protective Equipment (PPE) as indicated in the Safety Data Sheet (SDS) provided. This includes splash goggles to protect your eyes.

  • Q: Can I use hydrocarbons or flammable products with the SS2 unit?
    A: No, using hydrocarbons or flammable products with the unit may result in explosions, fire, and serious injury. Avoid using such products with the SS2 unit.

Air Powered Footwear Sanitizing Unit
Service Manual
SS2

READ ALL INSTRUCTIONS BEFORE USING OR SERVICING THIS UNIT. KEEP THIS MANUAL IN A LOCATION THAT IS READILY AVAILABLE TO USERS AND SERVICE TECHNICIANS.
English (Original Instructions)

Scan this code for service manual

Safety

WARNING
PEOPLE OR OBJECTS CAN BE HURT OR DAMAGED IF THIS UNIT IS NOT USED CORRECTLY!

Failure to read all the instructions before operating the unit may result in personal injury or death from the improper use or the chemical solution. Anyone handling, operating or using the unit must read and understand the instructions in the manual. The buyer assumes all responsibility for safety and proper use in accordance with the instructions.

Using or servicing the unit without appropriate personal protective equipment (PPE) may result in serious injury such as burns, rashes, eye, throat or lung damage and death. Always wear PPE as indicated in the Safety Data Sheet (SDS) when using or servicing the unit. Protect eyes, skin, and lungs against drifting spray.
To prevent chemical spray to face and eyes, ensure full foot insertion into unit and press down with heel. Wear splash goggles as directed by chemical manufacturer, SDS, or OSHA.
This unit is for use with fully protective footwear only. This unit is designed to help sanitize footwear at transition zones with a focus on reduced moisture. This unit is intended to sanitize shoe soles and not intended for any other use.
Chemical solutions may pose a health risk and death if they contact the skin or eyes, are inhaled or swallowed. Always read and follow all chemical safety precautions and handling instructions provided by the chemical manufacturer and the SDS associated with the chemical solution before using the unit.
Pressure within the equipment may cause an unexpected release of the chemical solution and cause serious injury such as burns, rashes, eye damage, throat or lung damage and death.
Always disconnect the air line from the unit before performing any maintenance, and clean the unit after each use.
Using the unit with fluid temperatures above 100°F (37.8°C) may result in scalding, burns, serious injury or death. DO NOT use a solution with a temperature above 100°F (37.8°C).
Operating the unit when damaged or leaking may result in exposure to chemical solutions, serious injury or death. Never use the unit if it is damaged or leaking.
Use of hydrocarbons and flammable products may result in explosions, fire and serious injury or death. Never use hydrocarbons or flammable products with the unit.

NOTICE
Servicing or modifying this unit with parts not listed in this manual may cause the unit to operate improperly. Do not use unauthorized parts when servicing the unit.
This unit is for use with fully protective footwear only.

PROTECT THE ENVIRONMENT
Please dispose of packaging materials, old machine components, and hazardous fluids in an environmentally safe way according to local waste disposal regulations

Service Guide

WARNING
Performing any maintenance with the unit pressurized may result in serious injury. Before conducting any maintenance, always ensure the unit has been depressurized by disconnecting the air line on the unit. Servicing or modifying this unit with parts not listed in this manual may cause the unit to operate improperly. Do not use unauthorized parts when servicing the unit. Remember to reconnect air line, and re-prime the unit according to the priming instructions in the operation manual after performing any maintenance.

Maintaining Your Unit

  • To keep your unit operating properly, perform the following daily maintenance procedures:

For SS2, SS2-BSH, SS2-FMH, and SS2-MBS units:

  • Inspect the stainless foot grate for debris and clean when necessary.

  • Collection basin should be emptied and cleaned each time the chemical supply container is changed or refilled. See Collection basin cleaning instructions for more information.
    Note : During heavy use, over-spray can fill up basin. Be mindful of fluid levels not reaching above manifold, this can cause the unit to operate improperly.

  • Verify nozzle assembly is free of any debris or blockage. Rinse with low pressure water if necessary.

  • Check suction line and strainer for debris. Clean as needed.

  • Inspect all tubing for leaks or excessive wear. Make sure all hose clamps and push fittings are in good condition and properly secured.

For SS2-MBS units only:

  • Remove brushes by lifting them out from the brush bracket. Remove debris and clean. Brushes should be replaced every 6 months depending on wear.
  • Slide out debris tray. Empty debris and wipe clean.
  • Base assembly of unit is fully stainless and can be cleaned in place by method suitable for stainless steel.

Collection basin cleaning instructions:

  1. Lift the shroud upwards to raise the top half of the unit. Then, slide the top half away from the bracket to detach it from the housing.

  2. Place the top half of the unit to the side.
    Note : Stand the top half of the unit on short end. Setting the unit down in other position may cause damage to nozzle assembly.

  3. Empty and clean the collection basin.

  4. Re-insert the top half of the unit by repeating step 1 in reverse order.

Servicing Your Unit

Most repairs on the unit can be performed with the following tools:

  • Crescent wrench (2x)
  • ⁷/16 in. (11 mm) socket wrench
  • 9/16 in. (14 mm) socket wrench
  • 2 Phillips head screwdriver

  • Thread seal tape
  • Hose cutters
  • Knife

Troubleshooting Your Unit

If your unit is not operating properly, try using these troubleshooting tips:

Issue Solution
If the unit does not spray
  • Check valve stem and roller cam for proper movement and compression.
  • If the pump is cycling, but unit does not spray, the pump may be air locked.
  • Verify pump springs are not worn or broken.
  • Check the suction line and strainer for debris and clean if necessary.
  • Verify the jug the unit is pulling from is vented, and filled appropriately.
  • Ensure nothing is blocking or impeding the full motion of the mechanism.

If the unit sprays irregularly|

  • Verify that the unit is connected to an appropriate compressed air source. Unit requires 40 psi (2.8 bar) with 1 CFM (28.3 l/min) to operate. To maximize unit lifespan and performance, compressed air should be clean and dry.
  • Note: If the air source has a high moisture content, you may wish to install a water separator before the unit.
  • Verify the pump is cycling regularly. Pump can be disassembled and the o-rings can be re-lubricated with a silicone-based lube.
  • Ensure the springs in the pump are not worn or broken.
  • Check the spray tips and make sure they are not clogged or blocked by debris. The spray tips may be removed and cleaned if necessary.
  • Verify that the jug the unit is pulling from is vented, and filled appropriately.

If the unit does not hold a prime|

  • Check hose clamps and ensure that barbs are secure.
  • Check all tubing connections and verify none are loose, broken, or leaking.

Shroud and Housing Assemblies

SHRA-SS2:
Shroud assembly for SS2 – includes shroud with spray guard, and mounting hardware

Item number Description
1 SPGRD-SS2
2 BPB142038

Phillips
3| SO142012| 1/4-20 x 1/2 in. threaded standoff – stainless
4| SHR-SS2| Shroud – SS2 – drilled out – includes warning and brand label
5| B142012-VS| 1/4-20 x 1/2 in. bolt – stainless – truss head Phillips – Vibra-Seal

HSGA-SS2:
Housing assembly for SS2 – includes mechanism mounting plate, rubber feet, and mounting hardware

Item number Description
6 B142058-VS

Vibra-Seal
7| HSG-SS2| Housing for SS2 – includes warning label
8| MPL-SS2| Mount plate for SS2 – stainless
9| LN1420| Locknut – 1/4-20 – stainless – nylon insert
10| RFT12| Rubber foot – 1/2 in. tall – includes internal washer
11| B142058-VS| 1/4-20 x 5/8 in. bolt – stainless – truss head Phillips – Vibra-Seal

Mechanism Assembly

MCHA-SS2:
Mechanism assembly for SS2 – includes fluid pump, mounting hardware, and air connection

Item number Description
1 AP14
2 R16
3 H14CL-PV
4 CLMPTB38-ADJ
5 TB14BL-PU

6

| VLVA-3W2P-SS2| Valve assembly – 3 way 2 position – SS2 – includes tooth washers and nuts
7| GRT-SS2| Grate – SS2 – stainless steel

8

|

TRD5161114

| 5/16 in. od x 11 1/4 in. long threaded rod – 5/16-18 end threads – stainless
9| LN516| Locknut – 5/16-18 – stainless – nylon insert

10

|

ACVB-3W2P-RCA

| Air control valve – nickel-plated brass – 3 way 2 position – roller cam actuator
11| AG100| Air gauge – 1/8 in. NPT – 100 psi dry model
12| LN1032| Locknut – 10-32 – stainless – nylon insert
13| B103212-PH| 10-32 x 1/2 in. bolt – stainless – pan head Phillips
14| RSPG1| Radial spring – 1 in. dia. – rubber

15

|

MNA-SS2

| Manifold assembly – SS2 – SS check valves and spray tips includes fitting and plug
16| PMPA-FLD-SS2| Pump assembly – SS2 – fluid – includes spring and seals
17| QF14P| Quick fit – 1/4 MPT x 1/4 od tube – polypropylene

Mechanism Sub-assemblies
MNA-SS2:
Manifold assembly for SS2 – includes SS check valves, spray tips, fitting, and plug

Item number Description
1 HBSSEL1814
2 MN-SS2
3 FCN12016

4

|

CVSS18MF

| Check valve – stainless steel – 1/8 MPT x 1/8 FPT – 1 lb. stainless steel spring – Viton seals
5| P18| Plug 1/8 MPT hex head 304 SS

VLVA-3W2P-SS2:
Valve assembly for SS2 – 3 way 2 position – includes tooth washers and nuts

Item number Description
6 QFEL18

7

|

ACVB-3W2P

| Air control valve – nickel-plated brass – 3 way 2 position – valve only – does not include tooth washers and nuts
8| QF1814| Quick fit – 1/8 MPT x 1/4 od tube – polypropylene
9| TB14BL-PU| 1/4 in. od blue tube – polyurethane available per ft.

Mechanism Sub-assemblies
PMPA-FLD-SS2-WF:
Pump assembly for SS2 – fluid – includes fittings, tubing, and check valves

Item number Description
1 TB14BL-PU
2 QFEL1814
3 H14CL-PV

4

|

CV14HB14M

| Check valve – PVC – 1/4 barb x 1/4 MNPT – 302SS spring – Viton seals – air flow right
5| PMPA-FLD-SS2| Pump assembly – SS2 – fluid – includes spring and seals
6| EL14M14F| 1/4 FPT x 1/4 MPT – polypro elbow
7| CLMPTB38-ADJ| Clamp for 1/4 in. od tube – plastic adjustable

8

|

CV14M14HB

| Check valve – PVC – 1/4 MNPT x 1/4 barb – 302SS spring – Viton seals – air flow left

RGA-R16-SS2:
Regulator assembly – includes regulator with 2x 1/4 in. and 1/8 in NPT ports, air gauge, and 1/8 in. NPT plug

Item number Description
9 AG100
10 AP14
11 R16
12 SSA14

Base With Handle

SS2-BSH:
Footwear sanitizer – SS2 and base with handle – includes 2.5 gal chemical jug with suction and SS rack
BSHA-SS2:
Base and handle assembly for SS2 – Includes floor base plate, mount plate adapter, handle, rubber feet, and hardware

Item number Description
1 B5161812-PH-VS

Vibra-Seal

2

|

FW3816

| Flat washer for 3/8-16 bolt – stainless – 0.41 in. id x 0.88 in. od x 0.05 in. thk
3| RFT1-516| Rubber foot – 1 in. tall – 5/16-18 threaded brass insert
4| HNDL-FS| Handle bar – footwear sanitizer
5| LN516| Locknut – 5/16-18 – stainless – nylon insert
6| B5161834-HH| 5/16-18 x 3/4 in. bolt – stainless – hex head
7| BRKT-BSPL-SS2| Bracket for SS2 base plate – stainless steel
8| BSHPL-SS2| Base plate for SS2 and handle – stainless steel
9| RFT12-SPC| Rubber foot – 1/2 in. tall – spacer
10| B14201-SH| 1/4-20 x 1 in. bolt – stainless – socket head

Floor Mount Base

With Handle
SS2-FMH:
Footwear sanitizer – SS2 and base with handle – includes 2.5 gal chemical jug with suction and SS rack
FMHA-SS2:
Floor mount and handle assembly for SS2 – includes floor mount with handle bracket, handle, mount plate adapter, and mounting hardware

Item number Description
1 HNDL-FS
2 LN516
3 FMHPL-SS2
4 B5161834-HH
5 BRKT-FMPL-SS2

Manual Boot Scrubber

SS2-MBS:
Footwear sanitizer – SS2 – includes floor mount, manual boot scrubber with combo handle, 2.5 gal chemical jug with suction, and SS rack
FMA-SS2:
Floor mount assembly for SS2 – includes floor mount bracket and mount plate adapter – no hardware

Item number Description
1 BRKT-FMPL-SS2
2 FMPL-SS2

MBS-C:
Manual boot scrubber combo – includes handle

Item number Description

3

|

HNDL-FS-C

| Handle bar – footwear sole sanitizer and manual boot scrubber combo
4| DBSH| Debris shield – manual boot scrubber – stainless steel
5| LN516| Locknut – 5/16-18 – stainless – nylon insert
6| B5161834-HH| 5/16-18 x 3/4 in. bolt – stainless – hex head

7

|

MBS100-C-BASE

| Manual boot scrubber floor mount bracket – footwear sanitizer base – stainless steel
8| BR10S| Block brush for boot scrubber side – polypropylene
9| BR10| Block brush for boot scrubber sole – polypropylene
10| DBTR| Debris tray – manual boot scrubber – stainless steel

Jug Assembly

J2.5BKSR:
2.5 gallon natural jug – includes black cap, suction and rack
JC35B-TAV:
Black 3.5 inch one way vented cap polypropylene – includes EPDM gasket, check valve, and bead chain tether assembly

Item number Description
1 B103234-SH-VNT
2 JC35B-P
3 CHN-JC35
4 CV-JC35
5 JC-G35
6 J2.5

SRPK-J2.5:
Suction valve assembly for 2.5 gallon jugs

Item number Description
7 P203CT-FS
8 H14CL-PV
9 TB14N-PE
10 H38CL-PV

11

|

QCPP-M-HAST

| 3/8 in. panel mount socket – suction 3/8 id x quick connect – Hastelloy spring – 11/16-24 thread
12| QCPP14HB-HAST| 1/4 in. in-line hose barb – polypro body – Hastelloy spring

SSJR2:
SS rack to mount chemical jug – includes mounting hardware

Item number Description
13 WMS14
14 SSJR2-P
15 WMS14A

size

Additional Configurations
SS2-FM:
Footwear sanitizer – SS2 – includes floor mount, 2.5 gal chemical jug with suction, and SS rack

Item number Description

1

|

SS2

| Footwear sanitizer – includes 2.5 gal chemical jug with suction and SS rack

2

|

FMA-SS2

| Floor mount assembly – SS2 – floor mount bracket and mount plate adapter – no hardware

SS2-BS:
Footwear sanitizer – SS2 and base mount – includes floor mount, 2.5 gal chemical jug with suction, and SS rack

Item number Description
3 SS2

rack
4| BSA-SS2| Base assembly for SS2 – includes base plate, mount plate adapter, rubber feet, and hardware

SS2-MBS-BS:
Footwear sanitizer – SS2 and manual boot scrubber with combo handle on base mount – includes 2.5 gal chemical jug with suction and SS rack

Item number Description
5 SS2-MBS

scrubber with combo handle, 2.5 gal chemical jug with suction, and SS rack
6| BSA-SS2-MBS| Base assembly for SS2 and manual boot scrubber – includes base plate, mount plate adapter, rubber feet, and hardware

MBS:
Manual boot scrubber with handle

Item number Description
1 HNDL-FS
2 DBSH
3 LN516
4 B5161834-HH

5

|

MBS100-C-BASE

| Manual boot scrubber floor mount bracket – footwear sanitizer base – stainless steel
6| BR10S| Block brush for boot scrubber side polypropylene
7| BR10| Block brush for boot scrubber sole polypropylene
8| DBTR| Debris tray – manual boot scrubber stainless steel

Optional Component

DBSH-EXT:
Debris shield extension for manual boot scrubber – stainless steel