FRIEDRICH Chill Inverter Series Room Air Conditioners
Specifications
- Chassis Models: 115 VOLT CCV15, 230 VOLT CCV18, CCV24
- Model Number: 93011012_01
- Electrical Requirements: Refer to model and serial number label on the unit
- Power Supply Cord: Equipped with a grounded 3-prong plug
- Refrigerant: R32
- Operating Limits: Outdoor side 61~110°F, 80% RH; Indoor side 61~90°F, 80% RH
Product Usage Instructions
Electrical Requirements
Ensure the air conditioner is plugged into a grounded 3-prong outlet. Do
not remove the ground prong, use adapters, or extension cords.
Registering the Appliance
You can register your appliance online at register.tcl.com. Retain the
original sales receipt for warranty claims.
Battery Warning
Avoid mixing old and new batteries or different types of batteries to
prevent hazards.
Grounding Method
The air conditioner must be grounded using the provided 3-prong power
supply cord. Plug it into a properly grounded outlet following local codes.
Installation Safety Principles
- Site Safety: Prohibit open flames and ensure proper ventilation.
- Operation Safety: Avoid static electricity, wear protective clothing, and do not use mobile phones.
- Refrigerant Leak Detection: Refer to the schematic diagram for detecting refrigerant leaks.
Frequently Asked Questions
-
Q: Where can I find the model and serial numbers of the air conditioner?
A: The 20-digit serial number is located underneath the barcode on the right-hand side of the AC unit. -
Q: What should I do in case of an electrical shock hazard?
A: Plug the air conditioner into a grounded 3-prong outlet, ensuring the ground prong is intact. Do not use adapters or extension cords to avoid risks of death, fire, or electrical shock. -
Q: What type of refrigerant does the air conditioner use?
A: The air conditioner uses R32 refrigerant.
Chill Inverter ® Series
Room Air Conditioners
IMPORTANT SAFETY INSTRUCTIONS
Before installing and using your air conditioner, please read this owner’s
manual carefully. Store this manual in a safe place for future reference.
Your safety and the safety of others is very important to us. Please pay
attention to all safety messages outlined in this owner’s manual.
WARNING: To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow the following basic precautions:
ELECTRICAL REQUIREMENTS
The electrical ratings for your air conditioner are listed on the model and
serial number label
located on the front right hand side of theunit (when facing the front).
REGISTER YOUR APPLIANCE
You can register your appliance online by going to register.tcl.com
Be sure to retain your original sales receipt. A valid proof of purchase is
required for all warranty claims.
BATTERY WARNING STATEMENT
Do not mix old and new batteries and do not mix alkaline, standard (carbon-
zinc) or rechargeable (ni-cad, ni-mh, etc.) batteries
Document your model and serial numbers here:
Model #__ Serial #____
You can locate your 20 digit serial number underneath the bar code (On the
right hand side of the AC).
WARNING| Specific electrical requirements are shown in the diagram
below.Follow there quirements below for the type of plug on the power supply
cord.|
---|---|---
- Electrical Shock Hazard
- Plug into a grounded 3 prong outlet. Do not remove the ground prong.
- Do not use an adapter
- Do not use an extension cord. Failure to follow these instructions can resultin death, fire, or electrical shock
|
Wiring Requirements| Power Supply Cord|
- 115V(103min-127max)
- (15K) (0-15 amps)
- (15K) (15 amp time-delay fuse or circuit breaker)
- 208/230V(187min-253max)
- (18K) (0-13 amps)
- (24K) (0-20 amps)
- (18K) (15 amp time-delay fuse or circuit breaker)
- (24K) (20 amp time-delay fuse or circuit breaker)
- Use on single outlet circuit only
|
RECOMMENDED GROUND METHOD
For your personal safety, this air conditioner must be grounded. This air
conditioner is equipped with a 3 prong power supply cord with a grounded plug.
To minimize the possibility of electrical shock, the cord must be plugged into
a 3 prong outlet and grounded in accordance with all local codes and
ordinances. If a 3 prong outlet is not available,it is the customer’s
responsibility to have a properly grounded 3 prong outlet installed by a
qualified electrician.
WE ARE READY TO HELP MOVE
contact us first with any questions
Introduction to Refrigerants R32
The refrigerants used for air conditioners are environmentally friendly
hydrocarbons R32.
This kind of erant is combustible and odorless. Moreover, it can burn and
explode under certain condition. However, there will be no risk of burning and
explosion if you comply with the following table to install your air
conditioner in a room with an appropriate area and use it correctly. Compared
with ordinary refrigerants, Refrigerant R32 is environmentally friendly and do
not destroy the ozone sphere and that itsvalue of greenhouse effect is also
very low.
Warning
- Please read the manual before installation,using,maintenance.
- Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer;
- The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater. Do not pierce or burn.
- Be aware that refrigerants may not contain an odour.
- information for handling, installation, cleaning, servicing and disposal of refrigerant.
- a warning to keep any required ventilation openings clear of obstruction.
- a notice that servicing shall be performed only as recommended by the manufacturer.
- Information for qualification of workers
- Information on servicing
- Repairs to sealed components
- Repairs to Intrinsically safe components
- Cabling
- Detection of flammable refrigerants
- Removal and evacuation
- Charging procedures
- Decommissioning, labelling and recovery
- Please contact the nearest after-sale service center when maintenance is necessary. At the time of maintenance, the maintenance personnel must strictly comply with the Operation
- Manual provided by the corresponding manufacturer and any non-professional is prohibited to maintain the air conditioner.
- The handling, installation, storage, servicing and disposal must comply with the ] provisions of gas-related national laws and regulations, and also national wiring regulation.
- It is necessary to clear away the refrigerant in the system when maintaining or scrapping an air conditioner. Be aware that refrigerants may not contain an odour.
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilitiesor supervision or instruction
concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the
appliance. Unit operation limits: Outdoor side 61~110, 80%RH, indoor side
61~90, 80%RH.
Installation Safety Principles
- Site Safety
- Operation Safety
- Installation Safety
- Refrigerant Leak Detector
- Appropriate Installation Location The left picture is the schematic diagram of a refrigerant leak detector.
Please note that
- The installation site should be in a well-ventilated area.
- When installing an air conditioner, it is necessary to take appropriate anti-static measures such as wear anti-static clothing and/or gloves.
- Installation or maintenance location should not be surrounded by obstacles or close to any heat source, flammable, and/or explosive areas or objects.
- If the product suers refrigerant leak during the installation, all personnel should go out till the refrigerant leaks completely for 15 minutes.If the product is damaged, a professional must carry such damages product back to the maintenance station. It is prohibited to weld the refrigerant pipe or conduct other operations on the contaminated site.
- The air conditioner unit needs to sit on a flat even surface.
- It is necessary to avoid the places where there are other electrical products, power switch plugs and sockets, kitchen cabinet, bed, sofa and other valuables directly under the lines on two sides of the indoor unit.
- Any ventilation openings of unit should be free from obstructions.
What’s in the Box
Open the carton and remove the below parts. Note: Illustrations in this manual are for explanatory purposes only. Product design and aesthetics may vary. Please search the entire package for the contents listed above as they may be packaged on top or underneath the main AC unit.
Introduction
For remote control model
Control Panel
Attention
- The outlooking and some function of remote control may vary according to the model.
- The shape and position of buttons and indicators may vary according to the model, but their function is the same.
- The unit confirms the correct reception of each press button with a beep.
Operating Instructions
For remote control model
You can easily operate this air conditioner by press relevant button on the
control panel as well as the remote controller.
Indication symbols of LED on control panel
Description
- Above LED lights on when the relevant mode is in used.
- In Eco mode, when the desired temperature is reached, the compressor will turn off and the fan will continue to run for 3 minutes before turning off. The fan will turn on for 1-minute at every 5-minute interval until the room temperature is above the set temperature, at which time the compressor turns back on and continues cooling.
- When the running time reaches 500 hours, the filter reminder will light up to indicate the filter needs to be cleaned. Press the Filter button to reset the filter reminder. Please see the maintenance section of this manual for filter cleaning instructions.
USING YOUR AIR CONDITIONER
Remote Control
Battery Replacement
Your air conditioner may come with two batteries. Put the batteries in the
remote control before use.
Setup & Installation
Window Requirements
- This air conditioner is designed to be installed in a standard single-hung or double-hungwindow with a window width between 29.5” and 41” (750mm – 1040mm).
- The lower sash (the lower part of the window that moves up and down) must allow for 14.5”of vertical clearance when open.
- All supporting parts must be secured to firm wood, masonry, or metal.
- The electrical outlet must be within reach of the power cord. (Electrical outlets only, no power strips or other outlets allowed.)
Note: Store the air conditioner in its product box while not in use.
Suggested Tools for Installation (Not Included)
CAUTION
Heavy object. Team handling is required during the installation process.
Getting Started
Step 1: Unboxing
Carefully remove all packaging and wraps from the air conditioner and its
accessories.
CAUTION
Heavy object. Team handling is required during the installation process.
Step 2: Testing
Before installing your AC, let’s test it to make sure it works properly, and
your outlet has the proper power level.
First, place it on a flat surface, plug it directly into a wall outlet (never
use a powerstrip or other device), and turn it on.
Next, use the Mode button on your control panel to change the AC to Cool Mode
and press the down arrow to set the temperature to the lowest setting. After 3
minutes, the AC should be blowing cool air. If so, please continue to the next
step. If not, see detailed troubleshooting tips at support.
Prepare Air Conditioner for Installation
WARNING
Excessive Weight Hazard
Use two or more people to move and installair conditioner.
Failure to do so can result in back or other injury.
-
Remove Packaging Materials:
-
Gently handle the air conditioner while unpacking the unit.
-
Place the air conditioner on a hard, flat surface.
-
Remove tape and glue residue from surfaces before turning on the air conditioner. Rub a small amount of liquid dish soapover the adhesive with the fingers. Wipe with a damp cloth and dry. Do not use sharp instruments, rubbing alcohol, flammable fluids, or abrasive cleaners to remove tape or glue. These products can damage the surface of the air conditioner.
-
Remove any packaging materials inserted into the side louvers.
-
Dispose of/recycle packaging materials in an appropriate way.
-
Pull down the front panel and remove the filter. Lift the front panel up wards and remove from the air conditioner.
-
Remove the four screws.
NOTES: The front panel screws must be reinstalled before mounting the air conditioner. -
Remove the cable connecting the display board
-
Hold the cabinet while pulling on the base handle to carefully remove the unit. IMPORTANT: To avoid damage, do not pull or lift near the topof the unit.
Step 3: Applying the Adhesive Foam Seal
Measure the length of the upper window frame, trim the adhesive foam seal to
the appropriate length, and apply as shown below.
Step 4: Placing Inside an Open Window
Using team lift, carefully lift the air conditioner and place in the
windowsill.
Next, close the window, making sure the air conditioner is centered and the
bottom rail is flush against the windowsill.
Note: The air conditioner should be tilted about 3° to allow for better drainage of condensate and rainwater.Using a level, measure about 1/3 bubble for the correct slant.
Step 5: Securing the Side Brackets
Extend the side brackets from both sides of the air conditioner onto the left
and right window frames and secure by installing four 3/4”screws as shown
NOTE:Fix the upper screws first, then the lower screws.
Step 6: Securing the Side Panels
Pull the side panels inwards to align with the brackets, then secure onto the
sides by snapping the jutting points onto the locking pins.
The side panels should be locked by ¹⁄4” Long Hex-head Screw .
Step 7: Sealing Any Gaps with Modeling Clay (Plasticene)
Fill the crevices between the side brackets and panels with the included
plasticene.
Step 8: Securing the Screw into the Top Rail
Secure the ¹⁄2″ Screw into the top rail of the air conditioner to the window
frame.
Step 9: Installing the Security Bracket (Recommended)
For security purposes, it is recommended to attach the security bracket to the
top of the window using two ¹⁄2″ screws to prevent opening the window from
outside. However, the security bracket can be removed to allow you to open the
window when desired.
Step 10: Filling the Gap Between Sashes Applying the Panel Seals
Trim the non-adhesive foam seal to the appropriate length and insert between
the window sashes. CAUTION: When open the window, besure that the fixed screws
are avaliable from the curtain to the window frame.
Measure the length extended by the side panels, trim the panel seals to the
appropriate length, peel off the backings and apply on the panels on both
sides.
Install Support Brackets
- Hold each support bracket flush ag ainst the outside of the window sill. Tighten each bracket to the bottom of the cabinet as shown below. Mark the brackets at top lever of the window sill and then remove.
- Assemble the sill angle brackets to the support brackets at the marked position as shown above. Hand tighten, but not all the way for any changes that may need to be made later during installation.
- Install the support brackets (with sill angle brackets attached) to the bottom of the cabinet as shown below.
- Tighten all 6 bolts securely.
Installing the Chassis into the Cabinet
- Team lift (two people) the air conditioner chassis and carefully slide it into the cabinet. Let the front of the air conditioner hang out approximately 6″.
- CAUTION: DO NOT PUSH ON THE CONTROLS OR FINNED COILS.
- Be sure the chassis is firmly seated in the back of the cabinet.
- Insert all screws removed during window installation and reattach the front panel、air filter and grille.
If AC is Blocked by Storm Window Frame
Add wood as shown above or remove store window frame/obstruction before
installing the window air conditioner.
If the Storm Window Frame must remain, be sure the drain holes or slots are
not caulked or painted shut.Accumulated rainwater or condensation must be
allowed to drain out.
CAUTION
When opening the window, be sure that the fixed screws are secured properly in
place without any objects affecting their attachment to theside brackets and
associated window frame to prevent the unit from becoming unstable and
falling.
Remove Left Telescopic Curtain Support Assy. Remove Right Telescopic Curtain Support Assy. Remove 2 screws fixed on left and right sides of case and chassis
Prepare the Wall
-
Prepare the wall in frame construction (including brickand stucco veneer). Working from inside the room, find the wall stud that is nearest the center of the installation area.
-
Cut a hole on each side of the center stud.
-
Measure between the inside edges of every other stud as shown below.
Carefully measure and cutan opening with the following dimensions depending on your model.
WIDTH”X”= inside model plus twice the thickness of the framing material used. HEIGHTY” = inside model eight plus twice the thickness of framing material used. -
Build a wooden frame withthe INSIDE dimensions of your model isted above (Measure twice).The frame depth should be the same as the wall thickness. Fill in extra space from the opening to the studs with wood spacers as shown below.
-
Nail the spacers to the studs.They should be flush with the dry wall. NOTE : If wall thickness is 8-1/2″ or more, add aluminum flashing over the bottom of the frame opening to assure water is unable to enter the area between the inner and outer wall.
Prepare and Install the Cabinet
- Slide the chassis from the cabinet. Refer back to the REMOVE CHASSIS instructions in the WINDOW MOUNTING SECTION.
- Place the cabinet into the opening with the bottom rail resting firmly on the bottom board of the wood frame.
- Position the cabinet so it is tilted properly for water re-movalas seen below.
- Secure the bottom rail to the wood frame with two ¹⁄2” Long Hex-head Screws and gaskets as shown below. Refer to the SUPPORT BRACKET ASSEMBLY in the WINDOW MOUNTING section to assemble the support brackets. A wooden strip nailed to the outside wall should be used in conjunction with the angled sill support brackets.
- Screw or nail the cabinet to the wooden frame using shims if the frame is oversized, to eliminate possible noise Remember to maintain proper slope for water elirnination.
- Install the chassis into the cabinet by following the steps described in the WINDOW MOUNTING section.
OPTIONAL: Caulking and installation of the trim on the interior wall may be done ifdesired. Caulk the openings around the top and sides of the cabinet and all sides of the wood sleeve to the opening.
NOTE: See the WINDOW MOUNTING instructions for the bottom rail seal location. Push the whole machine into the outer box, fasten the screws on both sides of the outer box, and assemble the panels to complete the assembly of the whole machine
Other Features
Filter Reminder
When the running time reaches 500 hours, the filter reminder will light up to
indicate the filter needs to be cleaned. Press and hold the Filter button for
5 seconds to reset the filter reminder. Please see the maintenance section of
this manual for filter cleaning instructions.
Display Auto Off
- Display will dim after 30 seconds (or after 15 seconds in sleep mode)
- Wake up the display by pressing any button
Memory
If the air conditioner is turned off but stays connected to the power,it will
resume the previous settings (except the timer setting) when it is turned on
again.
Drain Water
This unit was designed to collect moisture from condensation in a collection
pan in the base of the unit. The collected water is distributed by the rear
fan on to the condenser coil. This aids in the overall efficiency of the unit.
It is normal to hear the water sloshing around when the fan is spinning.
If this behavior is not desired, the drain cap at the rear of the AC can be
removed to drain a portion of the water.Doing so may lessen the efficiency of
the AC.A minimal amount of water will still remain in the drain pan.
Maintenance
Care and Cleaning
Clean your air conditioner occasionally to keep it looking new. Before
cleaning, be sure to unplug the unit from any and all power sources to prevent
electric shock or fire hazards.
Air Filter
The air filter should be checked at least once every month to see if it needs
cleaning. Never use hot water over 104°F (40°C) to clean the air filter. Never
attempt to operate the unit without the air filter. Trapped particles and dust
can build up over time, which can result in decreased airflow and can cause
the coils to accumulate frost. To clean the air filter:
- Pull the grille out from the indents on both sides at the front and remove the filter inside.
- Wash the filter using liquid dish soap and warm water. Rinse the filter thoroughly. Gently shake the filter to remove excess water.
- Let the filter dry completely before placing it into the air conditioner.
Note: If you do not wish to wash the filter, you may vacuum the filter to remove the dust and other particles.
Cabinet Cleaning
To clean the air conditioner’s cabinet:
- Using a cloth dampened in a solution of warm water and mild liquid soap, wipe down the unit and the front panel. Then, using a clean dampened cloth, make sure to wipe down the unit to remove all excess soap and continue to dry.
- Never use harsh cleaners, wax, or polish on the cabinet front.
- Be sure to wring out excess water from the cloth before wiping round the control. Excess water may damage the unit.
Storage
If you want to store the unit when not in use, we recommend removing the drain
plug at the back of the unit and slightly tilting the unit towards the rear to
drain any water in the pan in a safe manner. Next, clean the unit and then
store it back in the original packaging or box until next use.
Troubleshooting
PROBLEM | POSSIBLE CAUSES | SOLUTIONS |
---|
The air conditioner will not start
| The air conditioner is unplugged| Make sure the air conditioner plug is
pushed completely into the outlet.
The fuse is blown/circuit breaker is tripped| Check the house fuse/circuit
breaker box and replace the fuse or reset the breaker.
Power failure|
- The unit will automatically restart when power is restored.
- There is a protective time delay (approx. 3 minutes) to prevent tripping and overloading the compressor. For this reason, the unit may not start normal cooling for 3 minutes after it is turned back on.
The current interrupter device is tripped|
- Press the RESET button located on the power cord plug.
- If the RESET button will not stay engaged, discontinue use of the airconditioner and contact a qualified service technician.
The air conditioner does not cool as it should
| Air flow is restricted| Make sure there are no curtains, blinds or furniture
blocking the front of the air conditioner.
The temperature control may not be set correctly.| Lower the set thermostat
temperature.
The air filter is dirty| Clean the filter. Refer to MAINTENANCE.
The room may be too warm| Please allow time for the room to cool down after
turning on the air conditioner.
Cold air is escaping| Check for open furnace registers
and cold air returns.
The cooling coils are frozen| Switch to high fan speed and set the thermostat
to a higher temperature.
Temperature sensor is not well situated.| Temperature sensor behind the air
filter is touching the coil. Try to move it so it does not contact the cold
coil.
The air conditioner is freezing up| Ice blocks the air flow and stops the air
conditioner from cooling the room| Switch to high fan speed and set the
thermostat to a higher temperature.
---|---|---
The remote control is not working| The batteries are inserted incorrectly|
Check the position of the batteries.
The batteries may be dead| Replace the batteries.
Water is dripping outside| Hot and humid weather| This is normal.
Water is dripping INSIDE when the unit is cooling| The air conditioner is not
correctly tilted outside| Improper installation. Tilt air conditioner slightly
to the outside to allow water drainage. Refer to installation instructions.
Water is dripping INSIDE when the unit is cooling| Moisture removed from the
air is draining into the base pan| This is normal for a short period in areas
with low humidity and normal for a longer period in areas with high humidity
Noise when the unit starts| A “da-da” sound may occur for 30 seconds when the
unit is turned on due to the compressor starting.| This is normal.