BEOK TRV-601 Zig Bee Smart Thermostatic Radiator Valve Installation Guide

July 14, 2024
BEOK

BEOK-logo

BEOK TRV-601 Zig Bee Smart Thermostatic Radiator Valve

Product Information

Product: ZigBee Smart Thermostatic Radiator= Valve

Standard Accessories

  • TRV
  • ZigBee Smart Thermostatic Radiator Valve
  • Supporting remote control by Smart Life app
  • Voice control by Amazon Alexa and Google Assistant

Technical Specifications

  • Power Supply: 3 x 1.5 V alkaline AA batteries (not included)
  • Current Consumption: 100mA Max
  • Protection Degree: IP20
  • Ambient Temperature: 0~50°C
  • Surface Temperature: 90°C Max (at the radiator)
  • Connection: M30 x 1.5mm
  • Linear Travel: 4.3mm
  • Dimensions (W x H x D): 58.4mm x 97mm x 58.4mm
  • Weight: 117.7 g

Product Usage Instructions

Installation

  1. Choose the appropriate adapter for your valve type.
  2. Insert the batteries into the ZigBee Smart Thermostatic Radiator Valve.
  3. Screw the valve onto the radiator using the provided connection.

Setup and Configuration

  1. Download and install the Smart Life app on your smartphone.
  2. Add the ZigBee Smart Thermostatic Radiator Valve to the app by following the instructions.
  3. Connect the valve to your Wi-Fi router for remote control functionality.

Operation

  1. Use the Smart Life app to control the temperature settings of the radiator valve.
  2. You can also use voice commands with Amazon Alexa or Google Assistant for hands-free control.

Frequently Asked Questions (FAQ)

  • Q: What type of batteries does the ZigBee Smart Thermostatic Radiator Valve require?

    • A: The valve requires 3 x 1.5 V alkaline AA batteries (not included).
  • Q: Can I control multiple radiator valves with a single Smart Life app?

    • A: Yes, you can add and control multiple ZigBee Smart Thermostatic Radiator Valves within the Smart Life app.

ZigBee Smart Thermostatic Radiator Valve
Supporting remote control by smart life app,
voice control by Amazon Alexa and Google Assistant

Product Introduction

Standard accessories

BEOK-TRV-601-Zig-Bee-Smart-Thermostatic-Radiator-Valve-image
\(1\)

Technical specifications

Power Supply: 3 x 1.5 V alkaline AA batteries (not included)
Current Consumption: 100mA Max
Protection Degree: IP20
Ambient Temperature: 0~50℃
Surface Temperature: 90℃ Max (at the radiator)
Connection: M30 x 1.5mm
Linear Travel: 4.3mm
Dimensions(W x H x D): 58.4mm x 97mm x 58.4mm
Weight: 117.7 g

BEOK-TRV-601-Zig-Bee-Smart-Thermostatic-Radiator-Valve-image
\(2\)

Installation

  1. Press the battery compartment lock, remove the cover, and insert the batteries. 
  2. Initialize, the mandrel pull back, then “, ” is displayed and blinking on the screen.
  3. When “ ” stop blinking, install the TRV union nut with M30*1.5 thread for heating valve, and then tighten the nut.
  4. Press the middle button and then “ ” start blinking, the device enter valve adjusting process. After several minutes, the process is completed when initialized screen is displayed.

Attention
While inserting the battens please make sure the polarity of battery(+/-) is aligned.

How to install the adapter correctly

BEOK-TRV-601-Zig-Bee-Smart-Thermostatic-Radiator-Valve-image
\(10\)

Function Introduction

Tempe. control mode
Press the middle button to switch between Auto mode and Manual mode .

  • Auto mode
    When ” ” is displayed on the screen, It is under Auto mode. For time periods and setting temperature could be programmed per day, one week as a cycle, based on customized needs.

  • Manual mode
    When ”  ” is not displayed on the screen, It is under Manual mode. The device will won< according to current setting temperature, without controlled by the time period program.

  • Temporary mode
    Under Auto mode, “  ” will be blinking after setting temperature, and then It will enter Temporary mode. The device is switched to Manual mode temporarily, without controlled by the time period program. It will return to Auto mode by next time period.

Stop heating and pause heating

  • ON: In summer, rotate the knob clockwise until is displayed under manual mode to stop heating. At this time, the heating valve is fully open. This can extend the use life of valve.
  • OFF: In winter, rotate the knob counterclockwise until “OFF” Is displayed under manual mode to pause heating temporarily. At this time, the heating valve is closed and the frost protection is activated.

Attention: After the antifreeze function is activated, the valve will open Vilene the room temperature Is lower than 5 C, and the valve will be closed when the room temperature exceeds C to prevent damage to the radiator thermostatic valve due to freezing 7

  • Adjust setting temperature: Rotate the knob to adjust setting temperature, stepping by 0.5″C.

  • Screen rotation : Long press the Set Button for 3 seconds to switch the screen display direction. BEOK-TRV-601-Zig-Bee-Smart-Thermostatic-Radiator-Valve-image \(17\)

  • Open-window function : First, enter the APP home page to tum on the window detection function, the device will automatically identify whether the window is open. When it is detected that there is cold wind, and the temperature drops by more than 1.5°C within 4.5 min the open-window function will be activated. At this time, the screen displays ” По» LII , and the temperature is set to 12°C.

  • Anti-scale: TRV executes routine decalcification every Monday at 12:00 to protect the valve from calcification. will be displayed on the screen during decalcification.

*At1entlon: Mille the open-wi’ldcMl fu1ctlon ls actiVated, folk>wing operations will terminate It from taking effect (D Temperature -ng operation on the APP o, de\lice. ® The detected temperature rises by more than 1.S’C within 4.5 minutes @ No operation of the APP or device within 30 minutes.

  • Child lock function : Long press the middle button for 3 seconds until ” is displayed on the screen to activate the child lock. While the device is locked, long press middle button for 3 seconds until ” disappear to deactivate the child lock.

  • Restore factory settings: Long press the middle button and insert the battery at the same time U’1lil “,FR” is displayed on the screen and blinking for 3 seconds, the device will be restored to factory settings and restated.

Attention: Once the device is restored to factory settings, all previous settings can not be recovered.

APP remote control and voice control

BEOK-TRV-601-Zig-Bee-Smart-Thermostatic-Radiator-Valve-image
\(25\)

Network Configuration

Download Smart Life APP

Scan the QR code above or search “Smart Life” on App Store and Google Play to download the Smart Life APP.

Add gateway

  1. When the gateway is powered on, hold button for 5 seconds until the red light blinks rapidly.

  2. Enter the Home page, click ” + ” in the upper right corner, select Gateway Control – Wireless Gateway (Zigbee).
    BEOK-TRV-601-Zig-Bee-Smart-Thermostatic-Radiator-Valve-image
\(29\)

  3. Select 2.4GHz Wi-Fi network and enter password, click “Next”, confirm the indicator is blinking rapidly, and then click “Next”.

  4. Wait a moment until the device is found and initialized, then click “Done” to finish. BEOK-TRV-601-Zig-Bee-Smart-Thermostatic-Radiator-Valve-image \(30\)

Add device

  1. Under manual mode, rotate the knob counterclockwise until “ ” is displayed. Then long press the middle button for 3 seconds until ” ” is blinking
  2. In the page of gateway, click “Add subxtevlce”, click “LID a ready blink”, wait a moment until the iccn of lRV appears, then click “Done”. 
  3. Set the device name, and click “Done” to finish. The device has been added successfully.

Attention: Network configuration can only be done under manual mode.
The gateway must be added before adding TRV. The TRV must be added in the page of gateway.

APP Features

Mode selection
Click “ A ” to select mode.

Attention: Click “+ ” or “—” to adjust the setting temperature.

  • Auto mode: Four time periods and setting temp. could be programmed per day, one week as a cycle, based on customized needs.
  • Manual mode: The device will work according to current setting temp. without controlled by the time period program.
  • Off mode: The valve will be closed to stop heating.

Week program setting

  1. Click “ L ” to enter the week program setting page.
  2. Set four time periods and setting temperature based on customized needs.

BEOK-TRV-601-Zig-Bee-Smart-Thermostatic-Radiator-Valve-image
\(37\)

Advanced setting
Click ” ” to enter the advanced setting page.

BEOK-TRV-601-Zig-Bee-Smart-Thermostatic-Radiator-Valve-image
\(39\)

Device sharing function
Share the device to other family members, allowing them to remotely control the TRV device.

BEOK-TRV-601-Zig-Bee-Smart-Thermostatic-Radiator-Valve-image
\(40\)

  1. Click the Menu button, then click “Share Device”
  2. Click “Add home member”
  3. Fill in account information of home member.
  4. Choose an invitation method.

Voice control
After waking up the speaker, you can say

Amazon Alexa: Alexa,

  • Set the living room to 26 degree
  • Drop the living room by 1 degree
  • Raise the living room by 1 degree
  • Make the living room warmer
  • Turn on the living room child lock
  • Turn off the living room child lock
  • What temperature is the living room set to
  • What is battery on the living room

Google Assistant: OK google,

  • Set the living room to 23 degree
  • Turn on the living room child lock
  • Turn off the living room child lock
  • IS my living room child lock on?
  • Turn on child lock for the living room
  • Turn off child lock for the living room
  • Set the living room to auto
  • Set the living room to manual

Error code

Troubleshooting and maintenance

Error code Problem Solution
FD Temperature sensor abnormality Contact after-sales staff
F1 Slow valve operation Check the installation and heating valve
F2 The stroke is too long Check the fastening of TRV
F3 The stroke is too short Check the heating valve
F4 Running out of battery Replace batteries immediately

Battery symbol

( )

| Low battery| Replace batteries within 4 weeks

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals