RENOGY RSP220LSC Portable Solar Panel Compact Suitcase User Manual

July 15, 2024
Renogy

RENOGY RSP220LSC Portable Solar Panel Compact Suitcase

RENOGY RSP220LSC Portable Solar Panel Compact Suitcase

Applicability

The User Manual applies to the following products:

  • COMPACT-SUITCASE 220 Portable Solar Panel (RSP220LSC/RPP220LSC-VY20)
  • COMPACT-SUITCASE 400 Portable Solar Panel (RSP400LSC)

Disclaimer

  • Renogy ensures the accuracy, sufficiency, and the applicability of information in the user manual at the time of printing due to continual product improvements that may occur.
  • Renogy assumes no responsibility or liability for personal and property losses, whether directly and indirectly, caused by the user’s failure to install and use the product in compliance with the user manual.
  • Renogy is not responsible or liable for any failure, damage, or injury resulting from repair attempts by unqualified personnel, improper installation, or inappropriate operation.
  • The illustrations in the user manual are for demonstration purposes only. Details may appear slightly different depending on product revision and market region.
  • Renogy reserves the right to change the information in the user manual without notice. For the latest user manual, visit renogy.com.

COMPACT-suitcase Series Portable Solar Panel User Manual © 2024 Renogy. All rights reserved.

  • All information in the user manual is subject to copyright and other intellectual property rights of Renogy and its licensors. The user manual may not be modified, reproduced, or copied, in whole or in part, without the prior written permissions of Renogy and its licensors.

Trademarks

The following are trademarks or registered trademarks of Renogy in the United States and other countries:

RENOGY

|
---|---

  • The registered trademarks in the user manual are the property of Renogy. The unauthorized use of the trademarks is strictly prohibited.

Important Safety Instructions

Please save these instructions.

The user manual provides important operation and maintenance instructions for COMPACTSUITCASE Series Portable Solar Panel (hereinafter referred to as COMPACT-SUITCASE).
Read the user manual carefully before operation and save it for future reference. Failure to observe the instructions or precautions in the user manual can result in electrical shock, serious injury, or death, or can damage the COMPACT-SUITCASE, potentially rendering it inoperable.

Symbols Used

The following symbols are used throughout the user manual to highlight important information.

WARNING: Indicates a potentially dangerous condition which could result in injury or death.
CAUTION: Indicates a critical procedure for safe and proper installation and operation.
NOTE: Indicates an important step or tip for optimal performance.

General Safety Information

WARNING

  • DO NOT disassemble the unit or remove any attached components.
  • DO NOT puncture, drop, crush, penetrate, shake, strike, or step on COMPACT-SUITCASE.
  • DO NOT open, dismantle, repair, tamper with, or modify COMPACT-SUITCASE.
  • DO NOT place the unit on a surface constructed from combustible material.
  • DO NOT expose COMPACT-SUITCASE to direct flame or heat sources.
  • Please keep unit out of reach of children unless supervised by an adult.
  • Please keep unit away from explosives and corrosive substance.

CAUTION

  • DO NOT step, walk, stands or jump on the unit. Localized heavy loads may cause damage on solar cell, which will ultimately compromise the performance of the unit.
  • DO NOT band the unit, or the panel will be broken.
  • DO NOT immerse the unit in water.
  • Dispose of the unit according to the local recycling and environmental regulations.
  • For details on how to use the hooks included with the controller version of the solar panel, see ‘Portable Module Hook Installation’ on the product details page at renogy.com.

Package Contents

  • 1 x Renogy COMPACT-SUITCASE Portable Solar Panel
  • 1 x Case
  • 1 x User Manual
  • 1 x Controller hook (controller version only)

Installation

Open the packaging bag, grasp the handles and pull it upwards to extract the COMPACTSUITCASE section and raise the brackets to its maximum position.
Installation

Fully unfold the COMPACT-SUITCASE and place it on the ground.
Installation

Adjust the angle of the brackets to ensure the stability of the COMPACT- SUITCASE, with the lighting surface is facing towards the sun.
Installation

Operation

How to charge a power station

  • Place a solar panel under direct sunlight. Steer clear of objects that can shade the solar panel and slow down the charging process.
  • Connect the solar connectors of the solar panel with the solar charge cable (sold separately), then Connect DC input port of power station.
    How to charge a power station

The solar charge time is highly dependent on the solar irradiance and the ambient temperature.

The operating voltage of the solar panel shall exceed the minimum DC-input voltage of power station, and the open circuit voltage shall NOT exceed the maximum DC-input voltage of power station.

How to charge a battery

  • Connect COMPACT-SUITCASE connector to PV Terminals of charge controller (sold separately).
  • Connect the BATT Terminals of charge controller to battery terminals using tray cables (sold separately).
  • Set the charging parameter on charge controller, and the COMPACT-SUITCASE is ready to charge battery.
    How to charge a battery

How to connect COMPACT-SUITCASE in series/parallel

  • To expand the power output, COMPACT-SUITCASE can be connected either in series or parallel.

  • Connect COMPACT-SUITCASE in series.
    How to connect COMPACT-SUITCASE in series/parallel

  • Connect COMPACT-SUITCASE in parallel.
    How to connect COMPACT-SUITCASE in series/parallel

Specifications

Model| COMPACT-SUITCASE 220 (RSP220LSC/RPP220LSCVY20)| COMPACT- SUITCASE 400 (RSP400LSC)
---|---|---
Dimensions (fold)| 18.11 x 28.74 x 3.15 in / 460 x 730 x 80 mm| 27.9 x 33.7 x 0.8 in / 708 x 855 x 20 mm
Dimensions (unfold)| 72.56 x 28.74 x 0.8 in / 1483 x 730 x 20 mm| 111.8 x 33.7 x 0.8 in / 2838 x 855 x 20 mm
Weight (Approximately)| 15.87 lbs. / 7.2 kg| 30.25 lbs. / 13.7 kg
Operation Temperature| -40°F to 176°F / -40°C to 80°C
Max Power at STC| 220W| 400W
Open-Circuit Voltage| 23.3V| 47.2V
Short-Circuit Current| 12.1A| 11A
Optimum Operating Voltage| 20V| 40V
Optimum Operating Current| 11A| 10A
Cell Type| Monocrystalline Silicon
Connector| MC4 Compatible

FCC Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

Renogy Support

To discuss inaccuracies or omissions in this quick guide or user manual, visit or contact us at: renogy.com/support/downloads

contentservice@renogy.com

Questionnaire Investigation

To explore more possibilities of solar systems, visit Renogy Learning Center at:renogy.com/learning-center

For technical questions about your product in the U.S., contact the Renogy technical support team through:renogy.com/contact-us

1(909)2877111

For technical support outside the U.S., visit the local website below: United Kingdom uk.renogy.com

Renogy Empowered

Renogy aims to empower people around the world through education and distribution of DIY-friendly renewable energy solutions.

We intend to be a driving force for sustainable living and energy independence.

In support of this effort, our range of solar products makes it possible for you to minimize your carbon footprint by reducing the need for grid power.

Live Sustainably with Renogy

Did you know? In a given month, a 1 kW solar energy system will…

Save 170 pounds of coal from being burned

Save 300 pounds of CO2 from being released into the atmosphere

Save 105 gallons of water from being consumed

Renogy Power PLUS

Renogy Power Plus allows you to stay in the loop with upcoming solar energy innovations, share your experiences with your solar energy journey, and connect with like-minded people who are changing the world in the Renogy Power Plus community.

CUSTOMER SUPPORT

@Renogy Solar
@renogyofficial
@Renogy
Renogy reserves the right to change the contents of this manual without notice.
Manufacturer: RENOGY New Energy Co.,Ltd
Address: No.66, East Ningbo Road Room 624-625
Taicang German Overseas Students Pioneer Park
JiangSu 215000 CN
eVatmaster Consulting GmbH
Battinastr. 30
60325 Frankfurt am Main, Germany
contact@evatmaster.com
Manufacturer: RENOGY New Energy Co.,Ltd
Address: No.66, East Ningbo Road Room 624-625
Taicang German Overseas Students Pioneer Park
JiangSu 215000 CN
EVATOST CONSULTING LTD
Suite 11, First Floor, Moy Road Business
Centre, Taffs Well, Cardiff, Wales, CF15 7QR
contact@evatmaster.com

Symbol

Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals