BROAN HD50L, HD80L Fan Light Combination Ventilators Instruction Manual

July 12, 2024
Broan

BROAN HD50L, HD80L Fan Light Combination Ventilators

Product Specifications

  • Brand: BROAN
  • Model: HD50L
  • Installation: Ceiling installation only, up to a 12/12 pitch
  • Duct Size: 4″ round duct

Product Usage Instructions

Typical Installations
Ensure the following typical installations for proper setup:

Ceiling Joist Mounting
Mount the housing directly to the ceiling joist or truss using the provided mounting tabs. Ensure discharge is parallel to the joists.

Additional Framing Requirements
For installations requiring additional framing, follow the provided guidelines and ensure proper mounting of the housing anddischarge of air.

Power Cable Connection
Connect the power cable according to the specified instructions to ensure safe and reliable operation.

Frequently Asked Questions (FAQ)
Q: Can this product be mounted on a wall?
A: No, this product is designed for ceiling installation only.

This Owner’s Manual is provided and hosted by Appliance Factory Parts.
BROAN HD50L

Owner’s Manual
Shop genuine replacement parts for BROAN HD50L
Find Your BROAN HVAC Parts – Select From 1309 Models

READ AND SAVE THESE INSTRUCTIONS

WARNING

  1. Use this unit only in the manner intended by the manufacturer.
    If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.

  2. Before servicing or cleaning unit, switch power off at ser-vice panel and lock the service disconnecting means to pre-vent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

  3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.

  4. Sufficient air is needed for proper combustion and exhaust-ing of gases through the flue (chimney) of fuel burning equip-ment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigera-tion and Air Conditioning Engineers (ASHRAE), and the local code authorities.

  5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

  6. Ducted fans must always be vented to the outdoors.

  7. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) – protected branch circuit.

  8. Never place a switch where it can be reached from a tub or shower.

  9. This unit must be grounded.

CAUTION

  1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
  2. This product is designed for ceiling installation only. This product is designed for installation in ceilings up to a 12/12 pitch. Ductwork must point up. DO NOT MOUNT THIS PRODUCT IN A WALL.
  3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, con-struction dust, etc. off power unit.
  4. Please read specification label on product for further information and requirements.

Installer: Leave this manual with the homeowner.
Homeowner: Use and Care information on page 4.

TYPICAL INSTALLATIONS

BROAN-HD50L,-HD80L-Fan-Light-Combination-Ventilators-
\(2\)

  • Additional framing must be a 2×6 (minimum height), at least 9-inches long.

INSTALL THE HOUSING

PLEASE NOTE
THE FOLLOWING INSTALLATION ILLUSTRATIONS SHOW 2 X 6 JOISTS. IF YOU HAVE A TRUSS OR “I”-JOIST IN-STALLATION, MOUNT THE VENTILATOR TO THE ADDI-TIONAL FRAMING IN THE SAME MANNER. (Additional framing must be a 2×6 (minimum height), at least 9-inches long.)

New Construction

  1.  Choose the location for your fan in the ceiling. For best possible performance, use the shortest possible duct run and a minimum number of elbows.

  2. Position mounting brackets against joist so that bottom edge of housing will be flush with finished ceiling.
    Additional positioning feature for 5/8”, 1”, & 1-1/4” thick ceiling material: Holes in corners of housing are labeled with various ceiling material thicknesses. Position housing so bottom edge of joist is visible through a matched set of holes. The housing is now in the proper position for thatceiling material thickness.
    Additional positioning feature for 1/2” thick ceiling material:
    Bend two tabs, on side of housing, 900 outward. Lift housing until tabs contact underside of joist.
    Mark the keyhole slot on both mounting brackets.

  3. Set housing aside and drive nails partially into joist at the top of both keyhole marks.

  4. Hang housing from nails and pound nails tight. To ensure a noise-free mount, pound another nail through the top hole of each mounting tab.

INSTALL THE HOUSING

Existing Construction

  1. Choose the location for your fan/light in the ceiling. For best possible performance, use the shortest possible duct run and a minimum number of elbows.
  2. In n attic, position mounting brackets against joist. Trace out-line of housing on ceiling material.
  3. Set housing aside and cut ceiling opening slightly larger than marked.
  4. Place housing in opening so that its bottom edge is flush with finished ceiling. Nail to joist through keyhole on both sides. To ensure a noise-free installation, drive another nail through the top hole of each mounting bracket.
  5. Additional mounting holes are provided for installations where access from above is inconvenient or not possible. Nail or screw housing directly to joists or framing.

INSTALL THE DUCTWORK

NOTE: The duct connector has a counter-balanced damper flap. The flap will be “open” approx. 1″ when duct connector is attached to housing. This design permits insulation to be in direct contact with fan/light housing per UL (Underwriters Laboratories) stan-dards. The slightest backdraft, however, will close the damper flap, preventing air from entering unit or finished space.

  1.  Snap the damper/duct connector onto housing. Make sure that tabs on the connector lock into slots in housing. Top of damper/duct connector should be flush with top of housing.
  2. Connect 4” round duct to damper/duct connector and extend duct to outside through a roof or wall cap. Check damper to make sure that it opens freely. Tape all duct connections to make them secure and air tight.

CONNECT THE WIRING

  1. Wire unit following diagram. Run electrical cable as direct as possible to unit. Do not allow cable to touch sides or top of unit after installation is complete.

ATTACH THE GRILLE

  1. Slide light reflector into front of grille opening. Plug light into WHITE receptacle. Place grille / reflector combination over protruding screw, and fasten in place using acorn nut pro-vided. HAND TIGHTEN acorn nut 1/4 turn after it is snug.
  2.  Install light bulb (100 watt maximum – not included). Insert one tab on light lens into a slot in the grille / reflector combina-tion. Squeeze other tab slightly and snap into remaining slot.

USE AND CARE

WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND LOCK OUT SERVICE PANEL BEFORE CLEANING OR SERVICING THIS UNIT.

BULB REPLACEMENT
Remove lens by gently depressing sides and pull down.
Use 100 Watt maximum incandescent bulb.

MOTOR LUBRICATION
The motor is permanently lubricated. Do not oil or disassemble motor.

CLEANING

TO CLEAN LENS AND GRILLE:
Remove light lens and bulb. Remove nut in center of reflector and lower assembly. CAUTION: Grille and reflector are separate units. Unplug light from WHITE receptacle. Plastic parts can be cleaned with mild, soapy water (use a mild detergent, such as dishwashing liquid) and dried with a soft cloth. Do not use abrasive cloth, steel wool pads, or scouring powders.

TO CLEAN FAN ASSEMBLY:
Unplug fan assembly (BLACK receptacle). To remove motor plate: Find the single tab on the motor plate (located next to the receptacles). Push up near motor plate tab while pushing out on side of housing. Or insert a straight-blade screwdriver into slot in housing (next to tab) and twist screwdriver. Gently vacuum fan, motor and interior of housing. METAL AND ELECTRI-CAL PARTS SHOULD NEVER BE IMMERSED IN WATER.

SERVICE PARTS/PIEZAS DE SERVICIO

KEY PART NO.
No. CLAVE No. PIEZA DESCRIPTION/

  1. 97013578 Light Lens/Lente de la lámpara
  2. 97005316 Acorn Nut/Tuerca de caperuza
  3. 99770029 Bulb Holder/Portabulbo
  4. 97014211 Light Reflector/Reflector de la lámpara
      • 97014212 Light Reflector Assembly (includes Key Nos. 3 & 4)
    • Conjunto del reflector de la lámpara (incluye Clave No. 3 y 4)
  5. 97013974 Grille/Rejilla
  6. 97014926 Motor Plate/Placa del motor
  7. 99080519 Motor (HD50L)
    • 99080520 Motor (HD80L)
  8. 99020276 Impeller/Pistón impulsor
  9. 99260425 Motor Nut (2 req.)/Tuerca del motor (se req. 2)
  10. 99150582 Grille Screw/Tornillo de la rejilla
      • 97015161 Blower Assembly (HD50L) (includes Key Nos. 6 thru 10)
    • Conjunto del ventilador (HD50L)
    • (incluye Clave Nos. 6 de a 10)
      • 97015162 Blower Assembly (HD80L) (includes Key Nos. 6 thru 10)
    • Conjunto del ventilador (HD80L)
    • (incluye Clave Nos. 6 de a 10)
  11. 99270982 Receptacle (Black)/Receptáculo (negro)
  12. 99270981 Receptacle (White)/Receptáculo (blanco)
  13. 98009612 Wire Panel/Panel del cableado
      • 97015171 Wire Panel Assembly (includes Key Nos. 11,12,13)
    • Conjunto del panel de cableado (incluye Clave No. 11, 12 ,13)
  14. 97014922 Housing/Cubierta
  15. 97014185 Damper/Duct Connector/Conector del regulador de tiro/conducto
  16. 98008868 Wiring Plate/Placa de conexiones
  17. 99150575 Screw, #8-18 x .375/Tornillo, #8-18 x .375
  18. 99150471 Ground Screw/Tornillo de conexión a tierra
  • BROAN-HD50L,-HD80L-Fan-Light-Combination-Ventilators- \(1\)Not shown assembled.
    Order replacement parts by “PART NO.” – not by “KEY NO.”

  • No ilustrado ensamblado.
    Pida piezas de servicio dando como referencia el No. DE PIEZA, no el No. DE CLAVE.

BROAN-NUTONE ONE YEAR LIMITED WARRANTY Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN- NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the address stated below or telephone: 1-800-637-1453, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.