WOLF CT15G-S Gas Cooktops Installation Guide
- July 8, 2024
- Wolf
Table of Contents
WOLF CT15G-S Gas Cooktops
As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equipment. There are two types of potential hazards that may occur during installation.
Caution : signals a situation where minor injury or product damage may
occur if you do not follow instructions.
WARNING : states a hazard that may cause serious injury or death if
precautions are not followed.
Another footnote we would like to identify is
IMPORTANT NOTE: This highlights information that is especially relevant
to a problemfree installation.
INSTALLATION REQUIREMENTS
IMPORTANT NOTE: This installation must be completed by a qualified
installer, service agency or gas supplier.
IMPORTANT NOTE: Save these Installation Instructions for the local
inspector’s use. Please read the entire Installation Instructions prior to
installation.
Installer : please retain these instructions for local inspector’s
reference, then leave them with the homeowner.
Homeowner : please read and keep these instructions for future reference
and be sure to read the entire Use & Care Information prior to use.
IMPORTANT NOTE : This appliance must be installed in accordance with
National Electrical Codes, as well as all state, municipal and local codes.
The correct voltage, frequency and amperage must be supplied to the appliance
from a dedicated, grounded circuit which is protected by a properly sized
circuit breaker or time delay fuse.
The proper voltage, frequency, and amperage ratings are listed on the product rating plate. Record the model and serial numbers before installing the cooktop. Both numbers are listed on the rating plate, located on the underside of the cooktop.
- Model Number
- Serial Number
IMPORTANT NOTE:
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
- Warranty service must be performed by a Wolf authorized service center.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
- A ventilation hood or downdraft system is recommended (but not required) for use with the Wolf gas cooktop.
WHAT TO DO IF YOU SMELL GAS:
- Do not try to light any appliance.
- Do not touch any electrical switch.
- Do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire department.
BEFORE YOU START
- Proper installation is your responsibility. Have a qualified technician install this cooktop. You must also assure that electrical installation is adequate and in compliance with all local codes and ordinances.
- Wolf gas cooktops are manufactured for use with natural gas or LP gas. Please check product rating plate for type of gas needed.
- Proper gas supply connection must be available; refer to Gas Supply Requirements on page 10. Electrical ground is required; see Electrical Requirements on page 11.
- Check the location where the cooktop will be installed. The location should be away from strong draft areas, such as windows, doors and strong heating vents or fans. Do not obstruct flow of combustion and ventilation air.
- Make sure you have everything necessary for correct installation. It is the responsibility of the installer to comply with the installation clearances specified on the product rating plate. The rating plate can be found on the underside of the cooktop.
COMMON WEALTH OF MASSACHUSETTS
- Installations and repairs must be performed by a qualified or licensed contractor, plumber or gas fitter qualified or licensed by the state, province, or region where this appliance is being installed.
- Use only gas shut-off valves approved for use within the state, province, or region where this appliance is being installed.
- A flexible gas connector, when used, must not exceed 3′ (.9 m).
SITE PREPARATION
COUNTERTOP CUT- O U T D I M E N S I O N S
IMPORTANT NOTE : Countertop opening dimensions shown on the following pages must be used. The dimensions shown provide for required clearances.
These cooktops are designed to fit a standard 24″ (610) deep base cabinet with a 25″ (635) deep countertop. Before making the countertopcut-out, verify that the cooktop will clear the side walls of the base cabinet below. There should be at least 51/2″ (140) clearance between the countertop and any combustible surface directly below the unit. If the cabinet has a drawer, a 41/2″ (114) depth clearance from the countertop to the top of the drawer (or other obstruction) in the base cabinet is required. The drawer depth may need to be shortened to avoid interfering with the gas pressure regulator.
IMPORTANT NOTE: Do not seal the cooktopto the countertop. It must be removed if service is necessary.
LOCATION REQUIREMENTS
Illustrations on the following pages provide the overall dimensions,
countertop cut-out and installation specifications for Wolf gas cooktops.
Maintain the following minimum installation dimensions: Minimum horizontal
clearance from the sides and back of the cooktop cut-out to adjacent vertical
combustible construction, extending a minimum of 18″ (457) above the
countertop, is as follows: 7″ (178) from side edges of cut-out for the 15″
(381) cooktop; 9″ (229) from side edges of cut-out for the 30″ (762) and 36″
(914) cooktops; 21/2″ (64) from rear edge of cut-out.
Minimum vertical distance between the countertop and combustible materials
above the cooktop must be 30″ (762). Maximum 13″ (330) depth of overhead side
cabinets directly above and within side clearance.
IMPORTANT NOTE: When installing a ventilation hood, refer to the
specific requirements of the hood for the minimum dimension to countertop.
INSTALLATION SPECIFICATIONS:
The illustrations below provide the overall dimensions, countertop cut-out and installation specifications for Model CT15G. For Model CT15G, the gas service may be supplied through the floor if the cooktop is not installed above an oven. Refer to the illustration for specifics on placement of gas and electrical.
IMPORTANT NOTE: When multiple cooktop units are installed side by side, refer to the countertop cut-out dimensions on page 9.
INSTALLATION SPECIFICATIONS- MODEL CTI5G
Overall Dimensions
NOTE : Application shown allows for installation of two 15″ (381) modules side-by-side with 33″ (838) recommended cabinet width. 18″ (457) recommended cabinet width for installation of single 15″ (381) cooktop or module. *Minimum clearance from both side edges of cooktop cut-out to combustible materials up to 18″ (457) above countertop. **Minimum clearance from rear edge of cooktop cut-out to combustible materials up to 18″ (457) above countertop.
MODEL CT15G
- Overall Width 15″ (381)
- Overall Height 4″ (102)
- Overall Depth 21″ (533)
- Recommended
- Cabinet Width 33″ (838)
- Minimum Cabinet Depth 223/4″ (578)
- Minimum Height Clearance 4″ (102)
- Cut-Out Width 14″ (356)
- Cut-Out Depth 191/4″ (489)
- Unit dimensions may vary to ±1/8″ (3).
Countertop Cut-Out
The illustrations below provide the overall dimensions, countertop cut-out and
installation specifications for Model CT30G.
IMPORTANT NOTE: 33″ (838) wide cabinets are recommended for installation
of Model CT30G.
A Wolf 30″ (762) single built-in oven may be installed below Model CT30G. For
this installation, unless you are using cabinets deeper than 24″ (610), it is
recommended that the electrical and gas supply be placed in the base cabinet
to the right of the oven. Refer to installation instructions provided with the
built-in oven for additional specifications. If the Model CT30G is installed
above cabinets, the gas and electrical placement is not critical. A grounded
outlet needs to be placed within 4′ (1.2 m) of the right rear of the cooktop.
IMPORTANT NOTE: When multiple cooktop units are installed side by side,
refer to the countertop cut-out dimensions on page 9.
INSTALLATION SPECIFICATIONS- MODEL CT30G
WOLF GAS COOKTOPS
The illustrations below provide the overall dimensions, countertop cut-out and
installation specifications for Model CT36G.
IMPORTANT NOTE: 39″ (991) wide cabinets are recommended for installation
of Model CT36G.
A Wolf 36″ (914) built-in oven may be installed below Model CT36G. For this
installation, unless you are using cabinets deeper than 24″ (610), it is
recommended that the electrical and gas supply be placed in the base cabinet
to the right of the oven. Refer to installation instructions provided with the
built-in oven for additional specifications. If the Model CT36G is installed
above cabinets, the gas and electrical placement is not critical. A grounded
outlet needs to be placed within 4′ (1.2 m) of the right rear of the cooktop.
When a 36″ (914) built-in oven is installed below Model CT36G, it is
recommended that the rough opening for the oven be 7 3/4″ (197) from the floor
to ease the use of the oven door.
IMPORTANT NOTE : When multiple cooktop units are installed side by
side, refer to the countertop cut-out dimensions on page 9.
VENTILATION OPTIONS
IMPORTANT NOTE : It is recommended that you operate the Wolf gas cooktop with either a Wolf cooktop ventilation hood, downdraft system or Pro ventilation hood. Contact your Wolf dealer for details.
- Cooktop Wall Hood – 30″ (762) or 36″ (914) widths in classic stainless steel.
- Cooktop Island Hood – 42″ (1067) width in classic stainless steel.
- Downdraft Ventilation System – 30″ (762), 36″ (914) or 45″ (1143) widths, with top cover and control panel in classic, platinum and carbon stainless steel finishes (45″ downdraft available in classic finish only).
- Pro Wall Hood – 22″ (559), 24″ (610) or 27″ (686) depths and 30″ (762) to 66″ (1676) widths in classic stainless steel.
- Pro Island Hood – 36″ (914) to 66″ (1676) widths in classic stainless steel.
- Pro Hood Liner – available in widths to accommodate 30″ (762) to 60″ (1524) hood shells.
- All hoods have welded seams, sealed halogen lighting and removable, dishwasher-safe filters.
- Blower requirements may vary due to the length of ducting and number of angles. The basic recommendation is 1 CFM per 100 Btu/hr (.03 kW). Always consult your HVAC professional for more concise blower requirements.
- IMPORTANT NOTE: When installing a ventilation hood, refer to the specific requirements of the hood for the minimum dimension to countertop.
INSTALLATION OPTIONS
MULTIPLE COOKTOP INSTALLATION:
If the gas cooktop is to be used with any combination of additional cooktop units or modules with a filler strip, the cut-out width is calculated by adding the corresponding units’ cut-out dimensions plus 11/4″ (32) for each additional unit. Refer to the illustration below.
IMPORTANT NOTE: When multiple units are installed side by side, each unit must have its own separate recommended electrical circuit. When multiple gas units are installed next to one another, they can receive their gas supply from a common line. However, each unit MUST have its own regulator installed between the mainline and the gas cooktop. When two or more modules are installed together, an integrated module filler strip (IFILLER/S) is recommended. If a downdraft ventilation system is also installed, an integrated module support for downdraft ventilation (ISUPPORT) is also required (Model DD30 only). Contact your Wolf dealer for information on these accessory components.
Countertop cut-out dimensions for installation of multiple cooktops.
GAS SUPPLY REQUIREMENTS
IMPORTANT NOTE:
This installation must conform with local codes and ordinances. In the absence
of local codes, installations must conform with the American National
Standard, National Fuel Gas Code and National Electrical Code regulations.
EXPLOSION HAZARD—
Use a new CSA approved gas supply line and install a gas shut-off valve.
Securely tighten all gas connections. For LP gas, have a qualified technician
make sure the gas pressure does not exceed 14″ (34.9 mb) WC (water column).
Failure to do so can result in explosion, fire or death.
IMPORTANT NOTE: The gas cooktop must be connected to a regulated gas
supply.
IMPORTANT NOTE : This installation must conform with local codes and
ordinances. In the absence of local codes, installations must conform with
American National Standard, National Fuel Gas Code ANSI Z223.1 – latest
edition or CANI – B149.1 or 2.
IMPORTANT NOTE: The natural gas cooktop is rated for elevations up to
8,000′ (2438 m) without adjustment. Install a high altitude kit for elevations
from 8,000′ (2438 m) to 10,000′ (3084 m). The LP gas cooktop is rated for
10,000′ (3084 m).
The cooktop is equipped for use with natural or LP gas. It is design certified by the Canadian Standards Association (CSA) for natural or LP gases. The rating plate, located on the underside of the burner box, has information on the type of gas that should be used. If this information does not agree with the type of gas available, check with the local gas supplier. Provide a gas supply line of 3/4″ rigid pipe to the cooktop location. A smaller size pipe on long runs may result in insufficient gas supply. Pipe joint compounds, suitable for use with LP gas should be used. For LP gas, piping or tubing size can be 1/2″ minimum. LP gas suppliers usually determine the size and materials used on the system.
If local codes permit, a new CSA designcertified, 4–5′ (1.2–1.5 m) long, 1/2″ or 3/4″ ID, flexible metal appliance connector is recommended for connecting this cooktop to the gas supply line. Do not kink or damage the flexible connector when moving the cooktop. The pressure regulator has 1/2″ female pipe threads. You will need to determine the fittings required, depending on the size of your gas supply line, flexible metal connector and shutoff valve. If rigid pipe is used as a gas supply line, a combination of pipe fittings must be used to obtain an in-line connection to the cooktop. All strains must be removed from the supply and gas lines so the cooktop will be level and in line.
IMPORTANT NOTE: The supply line must be equipped with an approved external gas shut-off valve located near the cooktop in an accessible location. Do not block access to the shut-off valve. Refer to the illustration below. The inlet pressure to the regulator should be as follows for operation and checking the regulator setting:
- Natural Gas: Set pressure 5″ (12.5 mb) WC, supply pressure 7–14″ (17.5–34.9 mb) max.
- LP Gas : Set pressure 10″ (25 mb) WC, supply pressure 11–14″ (27.4–34.9 mb) WC.
LINE PRESSURE TESING:
- Testing above 1/2 psi (3.5 kPa) 14″ (34.9 mb) WC (gauge): The cooktop and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures greater than 1/2 psi (3.5 kPa).
- Testing below 1/2 psi (3.5 kPa) 14″ (34.9 mb) WC (gauge) or lower : The cooktop must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).
ELECTRICAL REQUIREMENTS
IMPORTANT NOTE : If codes permit and a separate ground wire is used, it
is recommended that a qualified electrician determine that the ground path is
adequate.
IMPORTANT NOTE: Check with a qualified electrician if you are not sure
whether the cooktop is properly grounded.
IMPORTANT NOTE: Do not ground to a gas pipe.
A 120 VAC, 60 Hz, 15-amp, fused electrical supply is required. A time-delay fuse or circuit breaker is recommended. It is recommended that a separate circuit serving only this appliance be provided. Electronic ignition systems operate within wide voltage limits, but proper ground and polarity are necessary. In addition to checking that the outlet provides 120 VAC power and is correctly grounded, the outlet must be checked by a qualified electrician to see if it is wired with correct polarity. A wiring diagram is provided in the literature package.
This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 latest edition or Canadian Electrical Code (CSA).
RECOMMENDED GROUND METHOD
IMPORTANT NOTE : For your personal safety, this cooktop must be
grounded. This cooktop is equipped with a 3-prong ground plug. To minimize
possible shock hazard, the cord must be plugged into a mating 3-prong ground-
type outlet, grounded in conformance with the National Electrical Code,
ANSI/NFPA 70 latest edition*, or Canadian Electrical Code (CSA) and all
local codes and ordinances. If a mating outlet is not available, it is the
obligation of the customer to have a properly grounded, 3-prong outlet
installed by a qualified electrician.
IMPORTANT NOTE** : If product is connected to a GFCI protected outlet,
nuisance tripping of power supply may occur, resulting in loss of product
operation.
WIRING DIAGRAM:
A wiring diagram covering the control circuit for each Wolf gas cooktop model can be found on page 15.
COOKTOP INSTALLATION
Remove the cooktop, pressure regulator, burner grates and burner caps from the shipping package. Lower the cooktop into the countertop cut-out opening. Center the cooktop in the opening and check that the front edge of cooktop is parallel to the front edge of the countertop. Check that all required clearances are met. Use a pencil to outline the rear edge of the cooktop on the countertop. Remove the cooktop from the countertop opening.
IMPORTANT NOTE: When repositioning the cooktop in the countertop cut-out opening, lift the entire cooktop up from the opening to prevent scratching the countertop. Remove the foam strip from the hardware package. Apply the foam strip around the bottom of the burner box flush with the edge as shown in the illustration below. Reinsert the cooktop into the countertop opening. Check that the cooktop is parallel to the front edge of the countertop. Lift the entire cooktop to make adjustments and align the rear edge with the pencil line. Attach the brackets to the burner box. Insert the 31/2″ (89) clamping screws into the brackets. Use a screwdriver to tighten the clamping screws against the underside of the countertop. Refer to the illustration below. Do not overtighten screws.
PRESSURE REGULATOR:
Install the pressure regulator with the arrow on the regulator pointing up
toward the unit and in a position where you can reach the access cap. Refer to
the illustration below.
IMPORTANT NOTE: All connections must be wrench-tightened. Do not make connections to the gas regulator too tight, as this may crack the regulator and cause a gas leak. Do not allow the regulator to turn on the pipe when tightening fittings.
GAS SUPPLY LINE CONNECTION:
Assemble the flexible metal connector from the gas supply pipe to the pressure regulator. You will need to determine the fittings required, depending on the size of your gas supply line, flexible metal connector and shutoff valve. Refer to the illustration below. Use a pipe-joint compound made for use with natural and LP gas. If a flexible metal connector is used, be sure the tubing is not kinked. Open the shut-off valve in the gas supply line. Wait a few minutes for the gas to move through the line. Refer to the illustration on page 10.
GAS LEAK TESTING
Use a brush and liquid detergent to test all gas connections for leaks. Bubbles around connections will indicate a leak. If a leak appears, shut off gas valve controls and adjust connections. Then check connections again. Clean all the detergent solution from the cooktop.
INITIAL LIGHTING :
The surface burners use electronic igniters inplace of standing pilots. When the cooktop control knob is pushed in and turned to the HIGH position, the system creates a spark to light the burner. This sparking continues until the electronic ignition senses a flame. Be sure to place the burner heads and caps on each burner base and position the burner grates over the burner bases and heads before lighting. To check operation of the surface burners, push in and turn each control knob to the HIGH position. The flame should light within four seconds.
If the burners do not light properly, turn control knob to the OFF position. Check that the burner heads and caps are in the proper position. Check that the power supply cord is plugged in and that the circuit breaker or house fuse has not blown. Check that the shutoff valve is in the ON position. Check operation again, if the burners do not light properly at this point, contact a Wolf authorized service center.
IMPORTANT NOTE : Initial lighting of the surface burners may take slightly longer, as air in the system must be purged before gas can be supplied to the burner.
Gas supply line connection
Dimensions in parentheses are in millimeters unless otherwise specified.
COOKTOP REMOVAL
If it is necessary to remove the cooktop for cleaning or service, shut off the
gas supply. Disconnect the gas and electric supply. Remove the mounting
brackets on the right and left side of the burner box and remove the cooktop.
Reinstall in the reverse order and check the gas connection for leaks.
TROUBLESHOOTING
IMPORTANT NOTE : If the cooktop does not operate properly, follow these troubleshooting steps:
- Verify that power is being supplied to the cooktop.
- Check that gas valves are turned to the ON position.
- Check the gas supply and electrical connections to ensure that the installation has been completed correctly.
- Follow troubleshooting procedures as described in the Wolf Gas Cooktops Use & Care Information.
- If the cooktop still does not work, contact a Wolf authorized service center. Do not attempt to repair the cooktop yourself. Wolf is not responsible for service required to correct a faulty installation.
IF YOU NEED SERVICE:
-
If service is necessary, maintain the quality built into your gas cooktop by calling a Wolf authorized service center.
-
To obtain the name and number of a Wolf authorized service center, check the Locator section of our website, wolfappliance.com or call Wolf Customer Service at
800-332-9513. -
When calling for service, you will need the cooktop model and serial numbers. Both numbers are listed on the rating plate, located on the underside of the cooktop.
The information and images are the copyright property of Wolf Appliance Company, Inc., an affiliate of Sub-Zero Freezer Company, Inc. Neither this book nor any information or images contained herein may be copied or used in whole or in part without the express written permission of Wolf Appliance Company, Inc., an affiliate of Sub-Zero Freezer Company, Inc. ©Wolf Appliance Company, Inc. all rights reserved.
WIRING DIAGRAMS
WOLF APPLIANCE COMPANY, INC. P. O. BOX 44848 MADISON, WI 53744
800-332-9513
WOLFAPPLIANCE.COM
Documents / Resources
| WOLF
CT15G-S Gas
Cooktops
[pdf] Installation Guide
CT15G-S Gas Cooktops, CT15G-S, Gas Cooktops, Cooktops
---|---
References
- steel.Pro
- Sub-Zero, Wolf, and Cove | Kitchen Appliances that Inspire
- Repair Your Grill: Shop Replacement Parts for 24,880 Models
- Wolf HVAC Parts - Select From 108 Models
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>