WOLF ICBSO3050TM-S-TH Series Built-In Ovens User Guide
- May 15, 2024
- Wolf
Table of Contents
Design Guide
M Series Ovens
ICB REVISED 4/2023
M Series Built-In Ovens
Four striking looks are just the beginning. Superior performance features include our dual convection fan system, touch-screen controls, convenient preset cooking programs, and improved interior lighting. There is more usable space inside for deliciousness on a grand scale. M Series Ovens can be installed in a standard or flush inset application.
M SERIES OVENS
TRANSITIONAL
Features and specifications are subject to change at any time without notice.
Throughout this guide, dimensions may vary by ± 3 mm.
PROFESSIONAL
CONTEMPORARY
TRANSITIONAL SINGLE OVEN
TRANSITIONAL DOUBLE OVEN
PROFESSIONAL SINGLE OVEN
PROFESSIONAL DOUBLE OVEN
CONTEMPORARY STAINLESS STEEL SINGLE OVEN
CONTEMPORARY STAINLESS STEEL DOUBLE OVEN
CONTEMPORARY BLACK GLASS SINGLE OVEN
CONTEMPORARY BLACK GLASS DOUBLE OVEN
Planning Information
The M Series Oven can be installed in a standard or flush inset application.
If a cooktop is installed above an oven, a minimum of 6 mm is required between
the units. Location of the electrical supply within the oven opening may
require additional cabinet depth.
Finish the edges of the opening. They may be visible when the door is open.
For standard installations, the face trim will overlap stiles and rails. Refer
to the chart below.
For flush inset installations, a minimum 3 mm reveal is required on all sides.
To ensure consistent reveals, each corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORT | MIN |
---|---|
Single Oven | 115 kg |
Double Oven | 181 kg |
TRIM OVERLAP | |
Top | 25 mm |
Bottom | 0 mm |
Sides | 18 mm |
DUAL INSTALLATION
Two 76 cm single M Series Ovens can be installed side by side in a standard or
flush inset application. A dual installation kit is required. To maintain
appropriate airflow, the ovens must be installed into one opening. Any
cosmetic or structural material placed between the ovens will impede airflow
and is not recommended. Refer to the illustrations on the following pages.
The dual installation kit is available through an authorized Wolf dealer.
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes and be properly
grounded (earthed).
Locate the electrical supply flush with the back wall and within the shaded
area shown in the illustration for your specific installation on the following
pages. For ease of installation, the electrical supply for the oven can be
placed in an adjacent cabinet within reach of the conduit.
Performance may be compromised if the electrical supply is less than 220
volts.
The oven is supplied with a single phase and 3-phase convertible power inlet
box. The wiring diagram covering the control circuit is provided with the
oven.
ELECTRICAL REQUIREMENTS—SINGLE OVEN
ELECTRICAL SUPPLY
Single Phase| 220–240 V AC, 50/60 Hz
3-Phase| 380–415 V AC, 50 Hz
MAX CONNECTED LOAD
Single Phase| 4.2–4.8 kW
3-Phase| 3.0–3.6 kW
ELECTRICAL REQUIREMENTS—DOUBLE OVEN
ELECTRICAL SUPPLY
Single Phase| 220–240 V AC, 50/60 Hz
3-Phase| 380–415 V AC, 50 Hz
MAX CONNECTED LOAD
Single Phase| 8.4–9.6 kW
3-Phase| 4.2–4.8 kW
M Series Single Oven
STANDARD INSTALLATION
NOTE: Location of electrical supply within opening may require additional cabinet depth.
FLUSH INSET INSTALLATION
25 mm minimum depth. Shaded areas will be visible and should be finished to match cabinetry.
22 mm for transitional, professional and contemporary stainless steel
models and 25 mm for contemporary black glass model.
Dimension provides minimum reveals.
NOTE: Location of electrical supply within opening may require additional
cabinet depth.
M Series Double Oven
STANDARD INSTALLATION
NOTE: Location of electrical supply within opening may require additional cabinet depth.
FLUSH INSET INSTALLATION
25 mm minimum depth. Shaded areas will be visible and should be finished to match cabinetry.
22 mm for transitional, professional and contemporary stainless steel
models and 25 mm for contemporary black glass model.
Dimension provides minimum reveals.
NOTE: Location of electrical supply within opening may require additional
cabinet depth.
DUAL STANDARD INSTALLATION
NOTE: Location of electrical supply within opening may require additional cabinet depth. A dual installation kit is required for this installation.
DUAL FLUSH INSET INSTALLATION
25 mm minimum depth. Shaded areas will be visible and should be finished to match cabinetry.
22 mm for transitional, professional and contemporary stainless steel
models and 25 mm for contemporary black glass model.
Dimension provides minimum reveals.
NOTE: Location of electrical supply within opening may require additional
cabinet depth. A dual installation kit is required for this installation.
Warranty
Wolf Appliance International Limited Warranty
FOR RESIDENTIAL USE
These Warranty Terms and Conditions (‘Warranty’) constitute your agreement
with Sub-Zero Group Australia Pty Ltd (ACN 610 807 899) (‘Wolf’) and will
apply to your service order. The benefits given by this Warranty are in
addition to all consumer guarantees and other rights and remedies prescribed
by the Australian Consumer Law and any other applicable laws.
Our products come with guarantees that cannot be excluded under the Australian
Consumer Law. You are entitled to a replacement or refund for a major failure
and compensation for any other reasonably foreseeable loss or damage. You are
also entitled to have the goods repaired or replaced if the goods fail to be
of acceptable quality and the failure does not amount to a major failure.
In addition to your rights and remedies under the Australian Consumer Law,
Wolf provides customers with a Warranty where, if any part of a Wolf product
is found upon inspection by an authorised Wolf representative or an associated
licensed technician supplied by either Wolf or a relevant approved supplier
(including a Wolf factory certified service) (‘Service Representative’) to be
defective in materials or workmanship, Wolf will repair and replace the part
as follows:
**FULL TWO YEAR WARRANTY* (Outdoor product full one year warranty)
For two years from the date of original installation, this Wolf Appliance
product warranty covers all parts and labour to repair or replace, under
normal residential use, any part of the product that proves to be defective in
materials or workmanship. All service provided by Wolf Appliance under the
above warranty must be performed by Wolf factory certified service, unless
otherwise specified by Wolf Appliance, Inc. Where the Service Representative
is unable to identify any fault in the product, Wolf may require the consumer
to provide proof that the product is defective. For the avoidance of doubt,
defective products or parts become Wolf’s property. Service will be provided
during normal business hours.
LIMITED FIVE YEAR WARRANTY
For five years from the date of original installation, Wolf Appliance will
repair or replace the following parts that prove to be defective in materials
or workmanship: gas burners (excludes appearance), electric heating elements,
blower motors (ventilation hoods), electronic control boards, magnetron tubes
and induction generators. If the owner uses Wolf factory certified service,
the service provider will repair or replace the above listed parts at no cost
with the owner paying for all other costs, including labour. If the owner uses
non-certified service, the owner must contact Sub-Zero Group Australia, (using
the information below) to receive repaired or replacement parts. Wolf
Appliance will not reimburse the owner for parts purchased from non-certified
service or other sources.
TERMS APPLICABLE TO EACH WARRANTY
The warranty applies only to products installed for normal residential use.
This warranty does not cover any parts or labour to correct any defect caused
by negligence, accident or improper use, maintenance, installation, service or
repair.
CLAIM PROCEDURE
In order to claim the Warranty, you must cease using the product when a fault
arises, contact Sub-Zero or authourised Sub-Zero dealer where the product was
purchased to report the issue and follow Sub-Zero’s directions regarding what
to do next. SubZero’s general contact details are as follows:
Sub-Zero Group Australia
11-19 Bank Place
Melbourne VIC 3000
Phone: 03 9600 2218 email:
serviceAU@subzero.com
EXCLUSIONS
Except to the extent required by law, all consumer guarantees,
representations, warranties, terms and conditions in relation to the products
(whether implied or otherwise) are hereby excluded to the maximum extent
permitted by law.
To the fullest extent permitted by law, Wolf excludes all liability for damage
or injury to any person, damage to any property and any indirect consequential
or other loss or damage.
*Stainless steel (doors, panels, handles, product frames and interior surfaces) are covered by a limited 60-day parts and labour warranty for cosmetic defects.
** Full one year warranty applies to outdoor product. Product must be approved
for outdoor use, designated by model and serial number.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>