Wolf ICBCG304 Gas Cooktop Installation Guide
- May 15, 2024
- Wolf
Table of Contents
Wolf ICBCG304 Gas Cooktop
Features and specifications are subject to change at any time without notice.
Important Note
To ensure this product is installed and operated as safely and efficiently as possible, take note of the following types of highlighted information throughout this guide:
- IMPORTANT NOTE highlights especially important information.
- CAUTION indicates a situation where minor injury or prod-uct damage may occur if instructions are not followed.
- WARNING states a hazard that may cause serious injury or death if precautions are not followed.
- IMPORTANT NOTE : Save these instructions for the local electrical inspector.
WARNING
This appliance shall be installed by the regulations in force and only used
in a well-ventilated space. Read the instructions before installing or using
this appliance.
WARNING
FOR AUSTRALIA ONLY:
- Do not use or store flammable materials in the appliance storage drawer or near this appliance.
- Do not spray aerosols in the vicinity of this appli-ance while in operation.
- Do not modify this appliance.
- This appliance is for indoor use only.
- A ventilation unit is suggested for use with this appliance. Refer to the instructions shipped with the ventilation unit for proper clearances.
- If the information in the guide is not followed, a fire or explosion may result, causing property damage, personal injury or death.
- This appliance must be properly installed and serviced by a qualified installer, service agency or gas supplier and grounded (earthed) by a qualified technician.
Product Information
Important product information including the model and serial number are listed
on the product rating plate. The rating plate is located on the bottom of the
cooktop. Refer to the illustration below. If service is necessary, contact
your authorized Wolf dealer.
IMPORTANT INSTRUCTIONS
- These instructions are only valid if the country symbol appears on the appliance. If the symbol does not appear on the appliance, it is necessary to refer to the technical instruc-tions which will provide the necessary instructions concerning the modification of the appliance to the conditions of use of the country.
- According to EN 30-1-1, this appliance is Class 3.
- The power supply cord must be obtained from an authorized Wolf dealer and installed by Factory Certified Service.
Installation Requirements
WARNING
Prior to installation, ensure the local distribution conditions (nature of
the gas and gas pressure) and the adjustment of the appliance are compatible.
The adjustment conditions for this appliance are stated on the label or data
plate. This appliance is not connected to a combustion products evacuation
device. It shall be installed and connected in accordance with current
installation regulations. Particular attention shall be given to the relevant
requirements regarding ventilation. Refer to the dimensions provided in this
guide, if ventilation installation specifications differ.
If a cooktop is being installed above an oven, a minimum of 6 mm is required between units. A minimum 140 mm is required from the bottom of the cooktop to combustible materials.
Electrical Requirements
Installation must comply with all applicable electrical codes and be properly
grounded (earthed). Locate the electrical supply within the shaded area shown
in the installation illustrations on page 6. A separate circuit servicing only
this appliance is required. A ground fault cir-cuit interrupter (GFCI) is not
recommended and may cause an interruption of operation.
ELECTRICAL REQUIREMENTS
- Electrical Supply 220–240 V AC, 50 Hz
- Service 0.2 A
- Receptacle grounding-type (earthed)
- Power Cord 1.8 m
Electrical Requirements
IMPORTANT NOTE : The connection of this appliance should be through a fused connection unit or a suitable isolator, which complies with national and local safety regulations. The on/off switch should be easily accessible after the appliance has been installed. If the switch is not accessible after installation (depending on the country) an additional means of disconnection must be provided for all poles of the power supply. When switched off, there must be an all pole contact gap of 3 mm in the isolator switch. This 3 mm contact disconnect gap must apply to any isolator switch, fuses, and/or relays according to EN60335.
Electrical Shock Hazard
Plug power cord directly into a properly grounded (earthed) outlet. Do not
defeat the grounding (earthing) nature of the plug. Do not use an adapter or
extension cord. Failure to follow these instructions could cause serious
injury or death. See installation instructions
Gas Supply
Installation must conform with local codes and ordinances. Locate the gas
supply as shown in the illustrations on page 6. The cooktop is equipped for
use with natural or liquid propane (LP) gas. The product rating plate has
information on the type of gas that should be used. For rating plate location,
refer to the illustration below. If this information does not agree with the
type of gas available, check with the local gas supplier. The gas pressure
regulator is built into the unit. The regulator is set to 10 mbar for natural
gas and 25 mbar for LP.
HEAT OUTPUT
- Surface Burner 5.3 kW (376 g/h)
- Surface Burner 3.5 kW (248 g/h)
- Surface Burner 2.7 kW (191 g/h)
Note
Apply duplicate Data label to the kitchen cabinet or cupboard door below the
cooktop. The cooktop must be connected to a regulated gas supply. The supply
line must be equipped with an approved external gas shut-off valve located
near the cooktop in an accessible location. Do not block access to the shut-
off valve. Refer to the illustration below. A gas supply line of 19 mm rigid
pipe must be provided to the cooktop. If local codes permit, a certified, .9 m
long, 13 mm or 19 mm ID flexible metal appliance connector is recommended to
connect the unit 1/2″ NPT (or ISO 7/1-14) male inlet to the gas supply line.
Pipe joint compounds, suitable for use with natural or LP gas should be used.
The appliance and its shut-off valve must be disconnected from the gas supply
piping system during any pressure testing of the system at test pressures
above 100 mbar. The appliance must be isolated from the gas supply piping
system by closing its individual manual shut-off valve during any pressure
testing of the system at test pressures equal to or less than 100 mbar. Wolf
natural gas cooktops will function up to 3124 m in altitude without adjustment
and LP gas cooktops will function up to 2621 m. If the installation exceeds
these elevations, contact your authorized Wolf dealer for a high altitude
conversion kit.
Note
For local gas and electrical code requirements, refer to AS/NZS 5601.1. TO BE
INSTALLED ONLY BY AN AUTHORIZED PERSON IF CONNECTING TO FIXED CONSUMER PIPING.
Gas Supply|
---|---
GAS RATING
| HEAT| GAS| | APPLIANCE| TYPES AND|
ICB MODEL| OUTPUT| UNITS| AMPS| CATEGORY|
PRESSURES (mbar)| COUNTRY OF DESIGNATION
ICBCG152TF/S| 6.2| kW| 0.2| I2H| G20 at 20| GB, AT, BG, HR, CZ, DK, EE, FI,
GR, HU, IS, IE, IT, LV, LT, NO, PT, RO, SK, SI, ES, SE, CH, TR, DE, FR, PO
| | | | I2E| G20 at 20| DE, LU, PL, RO
| | | | I2E+| G20 at 20/25| BE, FR
ICBCG152TF/S/LP| 440| g/h| 0.2| I3P| G31 at 37| GB, BE, HR, CZ, FR, GR, IE,
IT, LT, NL, PT, SK, SI, ES, CH, DE, FI, RO, PL, LV, HU
ICBCG304T/S| 14.2| kW| 0.2| I2H| G20 at 20| GB, AT, BG, HR, CZ, DK, EE, FI,
GR, HU, IS, IE, IT, LV, LT, NO, PT, RO, SK, SI, ES, SE, CH, TR, DE, FR, PO
| | | | I2E| G20 at 20| DE, LU, PL, RO
| | | | I2E+| G20 at 20/25| BE, FR
ICBCG304T/S/LP| 1007| g/h| 0.2| I3P| G31 at 37| GB, BE, HR, CZ, FR, GR, IE,
IT, LT, NL, PT, SK, SI, ES, CH, DE, FI, RO, PL, LV, HU
ICBCG304P/S| 14.2| kW| 0.2| I2H| G20 at 20| GB, AT, BG, HR, CZ, DK, EE, FI,
GR, HU, IS, IE, IT, LV, LT, NO, PT, RO, SK, SI, ES, SE, CH, TR, DE, FR, PO
| | | | I2E| G20 at 20| DE, LU, PL, RO
| | | | I2E+| G20 at 20/25| BE, FR
ICBCG304P/S/LP| 1007| g/h| 0.2| I3P| G31 at 37| GB, BE, HR, CZ, FR, GR, IE,
IT, LT, NL, PT, SK, SI, ES, CH, DE, FI, RO, PL, LV, HU
ICBCG365T/S| 16.9| kW| 0.2| I2H| G20 at 20| GB, AT, BG, HR, CZ, DK, EE, FI,
GR, HU, IS, IE, IT, LV, LT, NO, PT, RO, SK, SI, ES, SE, CH, TR, DE, FR, PO
| | | | I2E| G20 at 20| DE, LU, PL, RO
| | | | I2E+| G20 at 20/25| BE, FR
ICBCG365T/S/LP| 1198| g/h| 0.2| I3P| G31 at 37| GB, BE, HR, CZ, FR, GR, IE,
IT, LT, NL, PT, SK, SI, ES, CH, DE, FI, RO, PL, LV, HU
ICBCG365P/S| 16.9| kW| 0.2| I2H| G20 at 20| GB, AT, BG, HR, CZ, DK, EE, FI,
GR, HU, IS, IE, IT, LV, LT, NO, PT, RO, SK, SI, ES, SE, CH, TR, DE, FR, PO
| | | | I2E| G20 at 20| DE, LU, PL, RO
| | | | I2E+| G20 at 20/25| BE, FR
ICBCG365P/S/LP| 1198| g/h| 0.2| I3P| G31 at 37| GB, BE, HR, CZ, FR, GR, IE,
IT, LT, NL, PT, SK, SI, ES, CH, DE, FI, RO, PL, LV, HU
Note: This appliance is fitted with an internal regulator the operating pressure is Natural – 1.0 kph. The regulator is preset at the factory and should not require adjustment. Gas Certification No AGA 8101 G
381 mm Gas Cooktop
STANDARD INSTALLATION
NOTE: The shaded area above the countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area.
Australia Only
The recommended minimum height from the pan support to the underside of the
Range-hood is 650mm unless the range-hood manufacturer specifies a height
greater than 650mm
762 mm and 914 mm Gas Cooktop STANDARD INSTALLATION
NOTE: The shaded area above the countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. Electrical and gas supply location only applies to installations with built-in oven.
CUT-OUT WIDTH W
- 762 mm Cooktop 737 mm
- 914 mm Cooktop 889 mm
Installation
Cooktop Installation
Remove the cooktop and components from the shipping package and recycle
packing materials. Lower the cooktop into the countertop cut-out. Center
cooktop in the opening with the front edge aligned parallel to the front edge
of the countertop. Using a pencil, outline the rear edge of the cooktop on the
countertop. Remove cooktop. Apply the foam strip provided, to the perimeter of
the countertop opening. Refer to the illustration below. Do not seal the
cooktop to the countertop. Insert the cooktop into the opening. Verify the
cooktop is aligned with the front edge of the countertop. Attach the brackets
provided, to the bottom of the unit. Insert the 89 mm clamping screws into the
brackets. Use a screwdriver to tighten clamping screws against the bottom of
the countertop. Do not overtighten screws. Refer to the illustration below.
Gas Supply Connection
All connections to the gas piping must be wrench-tightened. Do not overtighten
or allow pipes to turn when tightening. If a flexible metal connector is being
used, verify it is not kinked, then attach the gas supply line to the
regulator on the cooktop. Open the valve and check for leaks by placing a
liquid detergent solution onto all gas connections. Bubbles around connections
indicate a gas leak. If a leak appears, close the shut-off valve and adjust
the connections.
Burner Grates
610 mm MODEL
For 610 mm models, the grates must be positioned correctly to ensure proper
burner performance. The grates have an indicator on the bottom of the front
edge. Position the grates with the indicator toward the front of the cooktop.
Refer to the illustration below.
Troubleshooting
IMPORTANT NOTE: If the cooktop does not operate properly, follow these troubleshooting steps:
- Verify electrical power is supplied to the cooktop.
- Verify the gas supply shut-off valve is in the open position.
- If the cooktop does not operate properly, contact Wolf Factory certified service. Do not attempt to repair the oven. Wolf is not responsible for the service required to correct a faulty installation.
Efficiency Rating
BURNER EFFICIENCY NATURAL GAS
- 2.7 kW Burner 55%
- 3.5 kW Burner 55%
- 5.3 kW Burner 55%
NOTE: Under EU No. 65/2014 and 66/2014.
WOLF APPLIANCE, INC. P.O. BOX 44848 MADISON, WI 53744 USA WOLFAPPLIANCE.COM 800.222.7820
References