Tenda O9 5GHz 11AC 23dBi Gigabit Outdoor CPE Installation Guide
- June 3, 2024
- Tenda
Table of Contents
Quick Installation Guide
5GHz 11 AC 23dBi Gigabit Outdoor CPE 09
Package contents
For product or function details, please go to www.tendacn.com.
Get to know your device
Port/Button | Description |
---|---|
RESET | Reset button. |
When the CPE is operating normally, hold down the button for about 8 seconds
and release it when all LED indicators light up and then turn off.
The CPE is restored to factory settings.
PoE/LAN| 10/100/1000 Mbps auto negotiation port for both power input and data
transmission. Connect this port to the PoE port of the PoE adapter to power on
the CPE using an Ethernet cable (CAT5e or a better Ethernet cable is
recommended, and the length should not exceed 60 meters).
Indicator| Status| Description
---|---|---
LED1, LED2, LED3
(Received signal strength
indicator)| Solid on/Blinking| The CPE is successfully bridged or connected to
other devices. —Solid on:The CPE works in AP, Repeater, P2MP or Router mode.
—Blinking:The CPE works in Client, Universal repeater or WISP mode.
Each LED indicator is set with a received signal strength value, which is the
threshold for the corresponding LED indicator to light up. You can judge the
connection quality through the status of these indicators.The default values
are shown below. You can change the values on the Wireless > Advanced page in
the web UI of the CPE.
Off| No device is connected to the CPE in a wireless manner, or the received
signal strength does not reach the minimum value (-90dBm by default) for any
LED indicator to light up.
PoE/LAN| Solid on| The CPE is powered on properly, but no data is being
transmitted.
Blinking| The CPE is powered on properly, and data is being transmitted over
the port.
Off| The CPE is not powered on properly.
Assemble and install the CPE
Stepl: Assemble the CPE.
-
Align the two bolts on one side of the center reflector panel with the long screw holes (the larger end) on the side reflector panel. Slide the center and side reflector panels in the opposite direction until the bolts fit into the smaller end.
-
Repeat 1 to fix another side reflector panel.
-
Align the slots of the CPE seat with the abutted edges of the center reflector panel and side reflector panels, and four hooks of the CPE seat with the four slots of the center reflector panel.
Note:
When fixing the CPE seat, ensure that the orientations of Tenda Logos on both the CPE seat and the front side of center reflector panel are the same. -
Press the CPE seat to fix it on the center reflector panel. Tips
To prevent the deformation of the reflector panels and decreasing of bridging quality, DO NOT face the reflector panels down and put them on a desk or a horizontal plane while and after fixing the CPE seat. -
Fix the reflector panels with the included screws.
-
Insert the CPE into the CPE seat from the front side of the center reflector panel.
Step2: Install the CPE
- Useascrewdriver to open the metal strap by turning the screw counter-clockwise. Put the universal shaft into the universal shaft fastener and fix the universal shaft and universal shaft fastener on the pole using the metal strap (Connect the two ends of the metal strap and use the screw driver to adjust the tightness).
- Direct the CPE seat at the universal shaft fastener, and screw the universal shaft fastener to fix the CPE (Ensure an appropriate tightness for you to adjust the orientation of the CPE later).
- Connect the PoE adapter to a power source and its LAN port to the POE/LAN port of the CPE using an Ethernet cable. The PoEILAN LED indicator of the CPE lights up.
- Adjust the orientation of the CPE to the horizontal with a spirit level. When the LED1, LED2 and LED3 indicators all light up after installation, it indicates that the best location is found.
- Fasten the universal shaft fastener and fix the Ethernet port cover.
Scenario 1:CCTV surveillance or point to point data transmission
Tips : At least two CPEs are required for bridging
1.Set up the CPEs (AP mode+ Client mode)
Option 1: Automatic bridging (recommended)
Tips:
- Automatic bridging only works for CPEs in factory settings
- Peer-to ·peer automatic bridging could fail if three or more powered CPEs in factory settings are placed nearby.
- After the bridging succeeds, the DHCP server of the CPEs will be disabled automatically.The IP address ofte (PE working in AP mode remains 192.168.2.1,and the IP address of the (PE working in Client mode is changed into 192.168.2.2
Step1 :Place two CPEs in factory settings next to each other.
Step2 :Use Ethernet cables to connect the PoE/LAN port of the CPEs to
the PoE port of the PoE adapters.
Step3 :Use the included power cords to connect the PoE adapters to power
sources. The PoE/LAN LED indicators of the two CPEs light up.
The LED1, LED2 and LED3 indicators of the two CPEs blink fast. When the LED1,
LED2 and LED3 indicators of one CPE light solid on and those of the other CPE
blink slow, the automatic bridging succeeds.
Tips:
If the automatic bridging fails, restore the two CPEs to factory settings and
try again
To restore a Pf to factory settings, hold down the RESET button on the (PE for
about 8 seconds and release it when all indicators light up, when the POE/LAN
LED indicator lights solid on again, the CPE is restored to factory setting.
Option 2: Manual bridging
Step1: Place two CPEs next to each other.
Step2: Power on CPE1 and connect it to a computer.
- Use the included PoE adapter to power on the CPE1. The PoE/LAN LED indicator ofCPEl lights up.
- Use an Ethernet cable to connect the LAN port of the PoE adapter to a computer.
Step3: Set CPEl to AP mode.
-
Start a web browser on the computer and visit 192.168.2.1. Enter the login user name and password and click Login.
Tips:
1(the login page does not appear, please refer to Q1 in FAQ. -
Select AP, and click Next.
-
Customize your SSID (WiFi name) and Key (WiFi password), select a Channel, a Security Mode (WPA2-PSK is recommended), and an Encryption Algorithm. Click Next. Record the SSID and Key for later setup.
-
Click Save, and wait until the CPE reboots automatically to activate the settings.
Step4: Set CPE2 to Client mode.
-
Perform Step 2 to power on the CPE2 and connect it to a computer.
-
Start a web browser on the computer and visit 192.168.2.1. Enter the login user name and password and click Login.
Tips:
If the login page does not appear, please refer to Q1 in FAQ -
Select Client, and click Next
-
Select the SSID of CPE1, which is Tenda_123456 in this example, and click Next.
-
Enter the Key of CPE1, and click Next.
-
Set the IP address to an unused one belonging to the same network segment as that of CPE1. For example, if the IP address of CPE1 is 192.168.2.1, you can set this device’s IP address to 192.168.2.X (X ranges from 2 to 254). Then click Next.
-
Click Save, and wait until the CPE reboots to activate the settings.
When the LED1, LED2 and LED3 indicators of CPE1 light solid on, and the LED1, LED2 and LED3 indicators of CPE2 blink, the bridging succeeds and the DHCP servers of the two CPEs are disabled automatically.
Application scenario
- Connect the CPEs with the LED1, LED2 and LED3 indicators solid on (AP mode -the transmitting end) to the switch which is connected to a NVR (Network Video Recorder).
- Connect the CPEs with the LED1, LED2 and LED3 indicators blinking (Client mode – the receiving end) to IP cameras or a switch which is connected to IP cameras.
After successful installation, the connection quality reaches the best when the LED1, LED2 and LED3 indicators ofthe CPEs light solid on or blink.
Scenario 2: Wireless ISP hotspot access
1.Set up the CPE
Step1: Power on the CPE and connect it to a computer.
- Use an Ethernet cable to connect the PoE/LAN port of the CPE to the PoE port of the PoE adapter.
- use the included power cord to connect the PoE adapter to a power source.
- Connect acomputer to the LAN port of the PoE adapter.
Step2: Set the CPE to WISP mode.
-
Start aweb browser on the computer and visit 192.168.2.1. Enter your user name and password and click Login. Tips:
If the login page does not appear, please refer to Q1 in FAQ -
Select wISP, and click Next.
-
Select the SSID of the ISP (Internet Service Provider) hotspot, which is Tenda_123456 in this example, and click Next.
-
Enter the password for the ISP hotspot in the Key box, and click Next
-
Select the Internet Connection Type of your ISP hotspot. PPPoE is used for illustration here. Enter the PPPoE user name and password provided by your ISP, and click Next.
-
Customize the SSID (WiFiName), select a security mode (WPA2-PSK is recommended), customize aKey, and click Next.
-
SetaniP address belonging to different network segment as that of your ISP hotspot. For example, if the IP address of your ISP hotspot is 192.168.2.1, you can set this CPE’s IP address to 192.168.X.1(X ranges from Oto 254 excluding 2). Then click Next.
-
Click Save. and wait until the CPE reboots to activate the settings.
When LEDl, LED2, and LED3 indicators of the CPE are blinking, the CPE is connected to the ISP hotspot successfully.
Application scenario
- Place the CPE over the roof.
- Connect the LAN port of the PoE adapter to the WAN port of your wireless router. The connection quality reaches the best when the LED1, LED2 and LED3 indicators of the CPE blink.
CE Mark Warning
This is a Class A product. In a domestic environment, this product may cause
radio interference, in which case the user may be required to take adequate
measures.
This equipment should be installed and operated with minimum distance 20cm
between the device and your body.
NOTE: (1)The manufacturer is not responsible for any radio or TV
interference caused by unauthorized modifications to this equipment. (2) To
avoid unnecessary radiation interference, it is recommended to use a shielded
RJ45 cable.
Declaration of Conformity
Hereby, SHENZHEN TENDA TECHNOLOGY CO., LTD. declares that the radio equipment
type 09 is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the
following internet address: http://www.tendacn.com/en/service/download-
cata-101.html
Operating Frequency Range: EU/5150-5250MHz (CH36-CH48);
EIRP Power (Max.): 22.98 dBm
Operating Frequency Range: EU/5470-5725MHz (CH100-CH116, CH132-CH140);
EIRP Power (Max.): 26.98 dBm
Software Version: Vl .0.0.1 O
For EU/EFT A, this product can be used in the following countries:| BE| BG|
CZ| DK| DE| EE| IE| EL| ES| FR| HR| IT| CY| LV
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
LT| LU| HU| MT| NL| AT| PL| PT| RO| SI| SK| Fl| SE| UK
Appendix FAQ
Q1. I cannot log In to the web UI of the CPEby entering 192.168.2.1. What should Ido?****
– A 1. Try the following solutions:
– Ensure that the CPE is connected to a power source and your computer
properly.
– Ensure that the IP address of the computer is set to an unused one, such as
192.168.2.X (X ranges from 2 – 254).
Q2:How to check that the CPEis under the best connection status?****
– A2:Try the following methods:
– Method 1: Observe the LED indicators of the CPE. The connection quality
reaches the best when the LED1, LED2 and LED3 indicators of the CPEs light
solid on or blink.
– Method 2: Log in to the web UI of one CPE (the default IP address is
192.168.2.1), check the bridging status in Status Wireless Status. Stronger
signal strength (-60dBm is better than -70 dBm) and less background noise
(-100d8mis better than -90 dBm) lead to better bridging signal.
03:After the bridging succeeds, the LED1, LED2 and LED3 indicators do not light up or only some of them do. What should I do?****
– A3: Try the following solutions:
– Ensure that the bridging distance between the CPEs is within the normal
range.
– Place the CPEs in an elevated location at the same height with few obstacles
nearby.
– Make slight direction adjustment of the CPEs by moving it vertically and
horizontally. Change the direction with an interval of 20- 30 s each time in
order to observe the change ofLEDl, LED2 and LED3 indicators until the best
signal is received.
RECYCLING
This product bears the selective sorting symbol for Waste electrical and
electronic equipment (WEEE). This means that this product must be handled
pursuant to European directive 2012/19/EU in order to be recycled or
dismantled to minimize its impact on the environment.
User has the choice to give his product to a competent recycling organization
or to the retailer when he buys a new electrical or electronic equipment.
Operating Environment
Operating Temperature: -30C -60C
Operating Humidity: (10% -90%) RH, non-condensing
Caution
Adapter Model: BN060-P12024
Manufacture: SHENZHEN HEWEISHUN NETWORK TECHNOLOGY CO.LTD.
Input: 100-240V – 50/60Hz 0.3A
Output: 24V=0.5A
:DCVoltage
FCC Statement
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 1 S of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
- Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Radiation Exposure Statement
This device complies with FCC radiation exposure limits set forth for an
uncontrolled environment and it also complies with Part 15 of the FCC RF
Rules.
This equipment should be installed and operated with minimum distance 20cm
between the device and your body.
Caution:
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate this equipment.
This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.
Operating frequency: 51 50-5250MHz, 5725-5850MHz
NOTE: (1) The manufacturer is not responsible for any radio or TV
interference caused by unauthorized modifications to this equipment. (2)To
avoid unnecessary radiation interference, it is recommended to use a shielded
RJ45 cable.
Technical Support
Shenzhen Tenda Technology Co., Ltd.
6-8 Floor, Tower E3, NO. 1001, Zhongshanyuan Road, Nanshan District, Shenzhen,
China 518052
USA hotline: 1-800-570-5892
Toll Free: 7×24 hours
Canada hotline: 1-888-998-8966
Toll Free: Mon – Fri9am – 6 pm PST
Hong Kong hotline: 00852-81931998
Global hotline: +86 755-2765 7180 (China Time Zone)
Website: www.tendacn.com
E-mail:support@tenda.com.cn
Copyright
02020 Shenzhen Tenda Technology Co. Ltd. AI rights reserved.
Tenda is a registered trademark legally held by Shenzhen Tenda Technology Co.,
Ltd. Other brand and product names mentioned herein are trademarks or
registered trademarks of their respective holders.
Specifications are subject to change without notice.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>