DELTA ESAH300-HAA07 DC Power System Owner’s Manual
- June 30, 2024
- Delta
Table of Contents
DELTA ESAH300-HAA07 DC Power System
Product Information
Specifications
- Model: ESAH300-HAA07
- Type: DC Power System
- Power: 300A for 48V system
- Dimensions: 485 x 341 x 345.7mm
- Weight: Approx. 25 kg
- Operating Temperature: Suitable for the Telecom industry and Data center application
Product Usage Instructions
Installation
To install the ESAH300-HAA Series power system, follow these steps:
- Ensure the system is powered off and disconnected from the mains.
- Place the system in a suitable 19-inch enclosure.
- Connect the necessary cables and ensure a secure connection.
- Power on the system and proceed with configuration.
Operation
Operating the ESAH300-HAA Series:
- Monitor the system performance through the LCD display or Web UI.
- Utilize the remote access feature for monitoring and management.
- Be aware of basic alarms and rectifier management for system health.
- Maintain proper environmental conditions for optimal performance.
Maintenance
To ensure longevity and efficiency:
- Regularly check event logs and data logs for any abnormalities.
- Perform battery tests periodically as recommended by the manufacturer.
- Clean and inspect the system components to prevent dust accumulation.
- Update firmware as necessary to access new features and improvements.
ESAH300-HAA Series is the power system playing the leader role in Telecom
industry and Data center application with 300A of the power for 48V system. It
is modular, expandable and can be easily installed in 19-inch enclosure, also
with high cost-performance ratio and gorgeous efficiency all rolled into one,
that is, your one of a kind energy core.
To maintain all aspects of the power performance, working perfectly at
extremely high efficiency up to 96.2% and keeping low consumption, not to
mention the ultra-leading power density, makes ESAH300-HAA Series the
extraordinary green design and the savior of reducing CO2.
Relying on the advanced real time monitoring mechanism and comprehensive
battery management, ensuring prevention before problems and lengthening the
battery life can reach each component’s full potential in a compact 8U shelf
and generate savings in OPEX.
Key Features
- Hot swap rectifier and controller
- Perfect Integration with Delta Outdoor Enclosure
- Compact Design 8U System
Applications
- 3G / 4G / 5G
- Fixed Line
- Datacom
ESAH300-HAA07
INPUT
- Voltage (nominal) 3Φ4W (R, S, T, N); VL-L: 380VAC; VL-N: 220VAC
- Voltage (range) VL-N:85 – 300VAC; De-rating ≤ 176VAC
- Frequency 45 – 66 Hz
- Connections CB 3 phase 63A, Icu ≥ 10kA, Uimp ≥6kV, electrical life ≥6000 times, IEC60898/IEC60947-2 Cable / Screw terminals / 3Φ and 1Φ Configurable
- SPD Class II, In ≥ 20kA (08/20μs, MOV, meet IEC 61 643-11, fault indicator and dry contact
- Solar Input Ability to connect with solar system (As optional, need specified accessories)
OUTPUT
- Voltage (nominal) -48 VDC
- Voltage (default) -54 VDC
- Voltage (adjustable range) -43 to -58 VDC
- Maximum Power @ 54VDC 300A with 06 rectifier slots for DPR 3000B-48
- Power Distributions
- DC MCB, Icu ≥ 6 kA, Uimp ≥4kV, electrical life ≥10000 times, IEC 60898-2/IEC 60947 – 2
- PL: 4x16A + 4x40A
- NPL: 2x63A+4x125A
- Battery: 125A x4, Icu ≥ 10 kA
- Power cable/ busbar: IEC61439-1. Copper bar 99,9% with Nickel plated
- LVDS LVBD: 400A x2 (NC type, Trip voltage adjustable)
- Shunt 300A x1
- Output Protection High Output Voltage; Over-temperature Protection; Over Current Protection
- SPD Class II, In ≥ 20kA (08/20μs, MOV, meet IEC 61 643-11, fault indicator and dry contact
CONTROL/ALARM
-
Operating Voltage 18 – 60 VDC
-
Input Power 0.8 ADC (Max.)
-
Security Access Password Protected Levels
-
User Interface LCD (128 x 96 dots) and Web UI
-
Remote Access Ethernet (SNMP)
-
Alarm Output Digital input x4, Dry Contact x6 (customizable)
-
Event Logs > 10,000
-
Data Logs 15,000
-
Basic Alarms
-
Mains Failure; Rectifier Module Failure; SPD Failure; Voltage Abnormal; Breaker Trip; Temperature Abnormal; LVD Trip
-
Rectifier Management Soft Start; Active Efficiency Management; Remote On/Off
Battery Management Compatible with LIB and VRLA Temp Compensation; Charge Current Limit; Capacity Setting Monitoring: Voltage/Current/Temperature; Boost Charge; Float/Equalized Charge; Battery Test (auto/manual) -
MECHANICAL
-
Dimensions (W x H x D) 485 x 341 x 345.7mm (19.0” x 13.4” x 13.6”), Suitable with 19 inches standard rack
-
Weight approx. 25 kg (55 lbs)
-
Connection Front access. Top-down cabling 0V bus-bar is equipped screws Support for M25 cable connection Spare space for output extension
ENVIRONMENTAL -
Operating Temperature 0 to +60ᵒC (+32 to +140ᵒF)
-
Storage Temperature -40 to +75ᵒC (-40 to +167ᵒF)
-
Altitude 0 to +3000 m
-
Related Humidity 5 %– 95% RH non-condensing
-
Acoustic Noise ≤ 60 dB (A)
-
STANDARDS Safety
-
EN / IEC 62368-1
-
EMC EN 300 386, class B (rectifier)
-
Environment RoHS
ORDERING INFORMATION
- Power shelf ESAH300 Series (P/N: ESAH300-HAA07) x 1 set
- Controller ORION ID:E1 (P/N: TPS1020028A) x 1 pcs
- Rectifier 3000W DPR3000B-48 (P/N: ESR-48/60FS) x 6 pcs (max)
- Add-on PV Power System ESAJ150-EAA02 x 04 set (max) (Optional)
- PV Charger 2900W DCS-48/56A C-A x 12 pcs (max) (Optional)
Delta Controller
Delta Controller is an intelligent controller for Telecom Power Solution. As a
brain of all aspects of power chain with elegant battery management suitable
for various types of batteries, ensuring with prevention before problems to
enable cost reduction could not be even easier.
With comprehensive functionality, besides locally accessing the configuration
and supervision unit, remote monitoring and alarming via web browser is also
acceptable. With the powerful data-gathering function played as an IOT
platform, improving site efficiency and ensuring the power always on-air is
our promise, our insistence.
INPUT
- Voltage (default) -54 VDC
- Voltage (adjustable range) -18 to -60 VDC
- Current 0.8 ADC (Max.)
MECHANICAL
- Dimensions (W x H x D) 83.4 x 42.0 x 203.1 mm (3.3 x 1.6 x 7.9 in)
- Weight 0.6 kg (1.32 lb)
STANDARDS
- Safety EN / IEC 60950, class I ; UL 60950; CAN / CSA-C22.2
- EMC EN 55022, class B Cooling Natural air flow
- Operating Temperature -40 to +70°C (-40 to +158°F) Relative Humidity 95%, non-condensing
FEATURES
- Number of Rectifiers Up to 128
- Number of Relay Output 6
- Remote Monitoring
- Web browser, REST, SNMP, Syslog, MODBUS, customer specific protocols via Ethernet , RS232, RS485 or modem
- Remote alarming dry contacts / SNMP traps / SMS; dial-out together with modem
FUNCTIONS
- System Site expansions using additional CANbus modules and additional I/O’s and measurements Battery Temperature compensated float charge, boost and equalize charge
- Rectifier
- Efficiency mode with advanced rectifier cycling
- Individual rectifier information and control
USER INTERFACE
- Local User Interface Color display; LCD display; touch panel; WLAN (option)
- WEB Web UI with configurable access rights, login control and user profiles
- Languages English, Traditional Chinese (option), Japanese (option)
ORDERING INFORMATION
- Model: ORION ID:E1 P/N: TPS1020028A
DPR 3000B EnergE
Delta’s technology leading telecom rectifier DPR 3000B EnergE provides the industrial leading efficiency of 96.2%. The single phase, hot pluggable fan cooled rectifier provides the 37.8W/in³ outstanding power density. Integrated with the high efficiency rectifier DPR 3000B EnergE, Delta power solution provides an energy saving solution for network base stations, wireless applications, fixed line applications and data communications.
DPR 3000B EnergE
INPUT
- Voltage (nominal) 220 / 230VAC
- Voltage (range) 85 – 300VAC; De-rating ≤ 176VAC
- Frequency 45 – 66Hz
- Power Factor > 0.99 @ 50% ÷ 100% load
- Total Harmonic Distortion < 5% @ 50% ÷ 100% load
- Lightening Protection EN 61000-4-5
- Non-destroy voltage of rectifier 415VAC (Max.)
OUTPUT
- Voltage (default) -53.5VDC
- Voltage (adjustable range) -43 to -58VDC
- Maximum Output Current 60A
- Maximum Power @ nominal Input 3000W
- Power Density 37.8W/in3
- Peak Efficiency Peak: 96.2%, Typical: ≥ 95.5% @ 30% – 90% load
- Load Regulation ≤ ± 250mV
- Ripple ≤ 150mV
- Current Sharing ≤ ± 5%
- Lightening Protection EN 61000-4-5
USER INTERFACE
- Alarm and Signaling CANbus to System Controller
- Indications
- OK Green Normal Operation
- NL Green Output current < 5%
- COM Yellow Communication Status
MECHANICAL
- Dimensions (W x H x D) 125.5 x 41.0 x 269.9mm (4.9 x 1.6 x 10.6 inch)
- Weight 2.0 kg (4.4 lb)
ENVIRONMENTAL
- Operating Temperature -40 to +75 ᵒC (-40 to +167 ᵒF ); De-rating above 55ᵒC (+131 ᵒF)
- Storage Temperature -40 to +80 ᵒC (-40 to +176 ᵒF)
- Altitude 0 to +4000m
- Related Humidity 5% – 95 % RH non-condensing
- Acoustic Noise ≤ 55dBA
STANDARDS
- Safety Passes TUV, CE
- Catch the CB certificate Complies with IEC/EN/UL 62368-1
- EMC EN 55022 AC Class B and DC output Class A EN 300 386
- Environment RoHS
- MTBF 300k hours @ 25 ᵒC (+77 ᵒF)
ORDERING INFORMATION
- Model: DPR3000B-48
- P/N: ESR-48/60F S . 3000W Single Phase Rectifier
All specifications are subject to change without prior notice.
Delta Electronics Inc.
- 16 Tungyuan Road, Chungli Industrial Zone,
- Taoyuan City 32063, Taiwan.
- T +886 3 452 6107
- F +886 3 452 7314
- www.deltaww.com
FAQ
What are the key features of the ESAH300-HAA Series?
The key features include hot swap rectifier and controller, perfect
integration with Delta Outdoor Enclosure, compact design in an 8U system, and
applications in 3G/4G/5G, Fixed Line, and Datacom.
How can I access the system remotely?
You can access the system remotely through an Ethernet connection using SNMP
protocol, allowing you to monitor and manage the system from a distance.
Read User Manual Online (PDF format)