BRAYER BR4702 Ultrasonic Humidifier Instruction Manual

June 3, 2024
BRAYER

BR4702 Ultrasonic Humidifier
Instruction Manual

Instruction manual

BR4702 Ultrasonic Humidifier

Ultrasonic hUmidifierBr4702
High-frequency vibration of the lamp divides water into the smallest particles of 1-5 microns in size. Cold water «mist» mixes well with the air and increases the relative air humidity.
Сomfortable room humidity level should be from 40% to 60%. Insufficient room air humidity (especially during the heating season) negatively affects humans’ and pets’ health as well as plants and furniture.

DESCRIPTION

  1. «Mist» release nozzle
  2. Decorative lid
  3. Water tank
  4. Water level scale
  5. Water inlet
  6. Water tank lid
  7. Illumination on/off button
  8. Operation/no water indicator
  9. On/off/mist release intensity control knob
  10. Air inlet grid and filter
  11. Aromatic oil container
  12. Body
  13. Process chamber with «sprayer»

SAFETY MEASURES AND OPERATION RECOMMENDATIONS

Read the operation manual carefully before using the unit; after reading, keep it for future reference.

  • Use the unit for its intended purpose only, as specified in this manual.
  • Mishandling the unit can lead to its breakage and cause harm to the user or damage to the user’s property, which is not covered by warranty.
  • Make sure that the operating voltage of the unit indicated on the label corresponds to your home mains voltage.
  • Place and use the Ultrasonic humidifier on a flat dry and water-resistant surface. The distance to the walls, other furniture and interior objects should be at least 30 cm.
  • Do not place the Ultrasonic humidifier near computers or other sensitive electronic appliances.
  • Do not place the unit on carpet surfaces with high piles.
  • Do not use the Ultrasonic humidifier outdoors.
  • It is not recommended to use the unit during lightning storms.
  • Protect the unit from impacts, falling, vibrations and other mechanical stress.
  • Never leave the unit connected to the mains unattended.
  • Do not use the unit near heating appliances, heat sources, or open flames.
  • Do not use the unit in places where aerosols are used or sprayed and close to inflammable liquids.
  • Do not use the unit in proximity to the kitchen sink, bathrooms, swimming pools, or other containers filled with water.
  • If the unit is dropped into water, unplug it immediately, and only then you can take the unit out of the water.
  • Do not let the power cord touch hot surfaces and sharp edges of furniture.
  • Unplug the unit after usage or before cleaning. When unplugging the unit, hold the power plug and carefully remove it from the mains socket, do not pull the power cord, as this can lead to its damage and cause a short circuit.
  • Do not touch the unit body, the power cord, and the power plug with wet hands.
  • Use only the removable parts supplied with the unit.
  • Use tap water cleaned with domestic water filters, distilled or boiled water. The water temperature should not exceed +40°.
  • Do not use sparkling or dirty water, and do not add any perfume additives to the water tank.
  • Do not switch the unit on without a water tank or if the water tank is empty.
  • Switch the Ultrasonic humidifier off when the water tank is empty.
  • Unplug the unit before removing the water tank
  • Do not cover the Ultrasonic humidifier during the operation.
  • Do not cover the air inlets on the unit body and avoid getting of foreign objects inside them.
  • Do not immerse the Ultrasonic humidifier, the power cord or the power plug into water or any other liquids.
  • Do not move or tilt the unit during the operation, and do not remove the water tank.
  • Switch the unit off and unplug it, and pour the water out of the tank and
  • the process chamber during cleaning or when you do not use the unit.
  • Unplug the unit before moving it to another place. Be careful when carrying the unit, hold in by the body with both hands.
  • Clean the unit regularly.
  • For child safety reasons do not leave polyethylene bags used as packaging unattended.

ATTENTION!
Do not allow children to play with polyethylene bags or packaging film. The danger of suffocation!

  • The unit is not intended for use by children.
  • Do not leave children unattended to prevent using the unit as a toy.
  • Do not allow children to touch the operating surface, unit body, power cord or power plug during the operation of the unit.
  • Close supervision is necessary when children or disabled persons are near the operating unit.
  • During the unit’s operation and breaks between operation cycles, place the unit out of reach of children.
  • The unit is not intended for usage by physically or mentally disabled persons (including children) or by persons lacking experience or knowledge if they are not under the supervision of a person who is responsible for their safety or if they are not instructed by this person on the usage of the unit.
  • Regularly check the integrity of the power cord.
  • If the power cord is damaged, it should be replaced by the manufacturer, maintenance service, or by similarly qualified personnel, to avoid danger.
  • Do not repair the unit by yourself. Do not disassemble the unit by yourself; in case of any malfunction or if the unit is dropped, unplug it and apply it to the service center.
  • To avoid damages, transport the unit in its original package only.
  • Keep the unit in a dry cool place out of reach of children and disabled persons.
    THE UNIT IS INTENDED FOR HOUSEHOLD USAGE ONLY

BEFORE THE FIRST USE

  • After the unit’s transportation or storage at a negative temperature, unpack it and wait for 3 hours before using it.
    Use the humidifier at room temperature from +10° to +40° and

  • with a relative humidity of less than 80%.

  • Unpack the unit and remove all the packaging materials.

  • Keep the original package.

  • Check the delivery set.

  • Read the safety measures and operating recommendations.

  • Examine the unit for damages; if the unit is damaged, do not plug it into the mains.

  • Make sure that the indicated specifications of the power supply voltage of the unit correspond to the specifications of your mains.

USING THE ULTRASONIC HUMIDIFIER

  • Remove the nozzle (1) and the decorative lid (2), and remove the water tank (3) from the unit body (12) (pic. 1).

  • Turn over the water tank (3), turn the lid (6) counterclockwise, and remove it (Pic. 2).

  • Fill the water tank (3) with the required amount of water.

  • Notes: — if the tap water used is hard, use water cleaned with household filters or mix tap water with distilled water in proportion 1:1.

  • Install the lid (6) on the water inlet (5) and thread it turning clockwise.

  • Install the tank (3) filled with water on the unit body (12), and install the decorative lid (2) and the nozzle (1).

  • Wait till the process chamber (13) is filled with water.

  • If you want to use the aromatization function, remove the container (11). Add some drops of water-soluble aromatic oil and install the container (11) back to its place (Pic. 3).

  • Notes: – use water-soluble aromatic oils only
    – if you are not going to use the aromatization function, remove the container (11), wash it with water, dry and install it back to its place

  • Insert the power plug into the socket.

  • Switch the Ultrasonic humidifier on by turning the knob (9) clockwise, the indicator will light up green.

  • Set the mist release intensity by turning the knob (9).

  • To turn the illumination on press button (7), to switch the illumination off press button (7) again.

  • If the water tank (3) is empty, the indicator will light up red.

  • Switch the Ultrasonic humidifier off by turning the knob (9) counterclockwise and unplug the unit.

  • Fill the tank (3) with water, install it to its place and switch the unit on.

  • After the unit operation, switch the Ultrasonic humidifier off by turning the knob (9) counterclockwise and unplug the unit.

CLEANING AND MAINTENANCE

WARNING!
Always switch the Ultrasonic humidifier off and unplug it before maintenance works or cleaning.

  • Hard water causes the appearance of mineral scale inside the process chamber (13), on the sprayer, and in the water tank (3); mineral scale leads to improper operation of the humidifier.
  • It is recommended to clean the process chamber (13) and the sprayer weekly and to change the water in the water tank (3).
  • If you are not going to use the Ultrasonic humidifier for a long
  • time:
    – pour the water out of the water tank (3) and the process chamber (13)
    – wash and clean the process chamber (13) and the sprayer
    – wash the water tank (3)
    – dry the unit thoroughly and take it away for storage.

WEEkLY CARE

  • Once a week wash the water tank (3), the process chamber (13), and the sprayer with warm water and neutral detergent and rinse thoroughly with water.
  • Add some detergent drops to the sprayer and wait for several minutes. Remove the deposits from the sprayer surface with a brush.
  • Notes: — you can use scale removal substances for electric kettles as a cleaning agent for the process chamber (13) and the sprayer strictly following the instruction.
  • Remove the grid (10), clean the filter from dust, and install the filter and the grid (10) back in their place.
  • Clean the unit body (12) with a slightly damp cloth and then wipe the body (12) dry.
  • Do not immerse the unit body (12), the power cord, and the power plug into water or other liquids. Provide that no liquid gets inside the unit body (12).
  • Do not use solvents or abrasives to clean the surface of the body (12) and the water tank (3).

STORAGE

  • Clean the Ultrasonic humidifier before taking it away for storage, make sure that the Ultrasonic humidifier parts are dry, pack the Ultrasonic humidifier in the original package.
  • Do not store the unit with the remaining water in the tank (3) and the process chamber (13).
  • Keep the Ultrasonic humidifier in a dry cool place out of reach of children and disabled persons.

TROUBLESHOOTING

Problem Possible causes Troubleshooting

The indicator
doesn’t light up, no mist release| No supply voltage or the main socket is damaged.| Connect the unit to the mains.
Plug another, known good appliance to the socket to make sure that the socket works properly.
The indicator is glowing red, with no mist release.| The water tank is empty.| Fill the water tank with water.
The released mist has a foreign smell.| The first use of the unit.
cool place.| Drain the water from the water tank and leave it open for several hours in a
Stale water in the tank.| Unplug the unit, remove the water tank, pour out the water, wash the tank and fill it with clean water.
Low mist release intensity| Mineral scale on the sprayer.| Unplug the unit and clean the sprayer.

DELIVERY SET

  1. Ultrasonic humidifier assembled — 1 pc.
  2. Manual — 1 pc.

TECHNICAL SPECIFICATIONS

  • Power supply: 220-240 V, ~50-60 Hz
  • Rated input power: 25 W
  • Water tank capacity: 6.0 l
  • Water discharge: 250 ml/h
  • Humidified area: up to 25 sq.m.
  • Filter capacity: 3000 l

RECYCLING

To prevent possible damage to the environment or harm to the health of people by uncontrolled waste disposal, after the expiration of the service life of the unit or the batteries (if included), do not discard them with usual household waste, but take the unit and the batteries to specialized stations for further recycling.
The waste generated during the disposal of the unit is subject to mandatory collection and consequent disposal in the prescribed manner.
For further information about recycling of this product apply to a local municipal administration, a disposal service, or to the shop where you purchased this product.
The manufacturer reserves the right to change the appearance, design, and specifications not affecting the general operating principles of the unit, without prior notice.
3 years unit operating life is 3 years
The manufacturing date is specified in the serial number.

In case of any malfunctions promptly apply to the authorized service center.

Produced for «Ruste GmbH»,
Berggasse 18/18, 1090 Vienna, Austria
Made in China
т.: +7 (495) 297-50-20,
e-mail: info@brayer.su
brayer.su

https://tm.by

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals