Product Specification
Product Name: Smart Gateway
Product Model: DSGW-090J

Revision History

Specification Sect. Update Description By
Rev. Date
1.0 2023-12-12 New version release
1.1 2023-12-19 Change the LTE function
1.2 2024-1-17 Add the description of WakeUp pin
1.3 2024-5-16 Modify model and update parameters

Approvals

Organization Name Title Date

Product Description

1.1. Purpose and Description
The DSGW-090J is a Smart Gateway utilized in smart healthcare, pension service applications and smart home systems. Serving as a central gateway, it supports various wireless protocols, including Wi-Fi 2.4G and BLE 5.2. This allows users to connect to the network through Wi-Fi. Additionally, it facilitates the integration of smart sensors by supporting their connection via its multi- protocol features.

1.2. Product Feature Summary

  • OS: OpenWrt
  • USB 5V type C Power supply and 50-17V power supply through RJ45
  • Processor: MT7628AN, MIPS24KEc, 580MHZ
  • RAM: 128MB
  • Flash:64MB
  • Support IEEE802.11n, IEEE802.11g, IEEE 802.11b Protocol
  • Support Bluetooth 5.2
  • One RJ45 supports UART, Hardware Signal, Power supply

1.3. Hardware Block Diagram

ZHEJIANG DSGW 090J Smart Gateway - Hardware Block
Diagram

Mechanical Requirement

ZHEJIANG DSGW 090J Smart Gateway - Mechanical
Requirement

Specification

3.1. Technical Specification

Category Specifications
CPU MT7628AN, MIPS24KEc, 580MHZ
System OpenWrt
RAM 128MB
Storage 64MB SPI Flash
Power Supply USB Type-C 5V/2A, RJ45 50-17V
Indicator LEDs 1). Power LED 2). Network Sate 3) Control Box State
Antenna FPC Antenna
Interface TF Card Slot x 1, SIM Card Slot x 2
RJ45 UART, Hardware Signal, Power
Reset Factory reset button. To reset the Gateway to its original factory

settings, press and hold it for more than 10 seconds
Installation method| Flat, bed frame via mounting bracket
Operating Temperature| -10℃~55℃
Storage Temperature| -20℃~65℃
Operating humidity| 10%~90%
IP rating| IP22

3.2. Cable Pinout

ZHEJIANG DSGW 090J Smart Gateway - Cable Pinout

CO61 Side Pin #| CO61 Side Pin Functionality| Color| Bridge Side Pin Functionality| Bridge Side Pin #
---|---|---|---|---
1| v_perm, 50v – 17v| Black| Power| 1
2| GND| Red| GND| 2
3| WakeUp/UBL HW Signal| Orange| Wakeup Signal| 3
4| (Not Populated)| —| (Not Populated)| 4
5| (Not Populated)| —| (Not Populated)| 5
6| (Not Populated)| —| (Not Populated)| 6
7| RXD 3.3v (White)| White| URT—TXD| 7
8| TXD 3.3v (Blue)| Blue| URT—RXD| 8
9| (Not Populated)| —| (Not Populated)| —
10| (Not Populated)| —| (Not Populated)| —

Remark: The Wakeup signal from Bridge shall be isolated ,The isolation circuitry is designed into the bridge (DSGW-090J). Wakeup volatage up to 50V .

ZHEJIANG DSGW 090J Smart Gateway - Wakeup volatage

3.3. Performance Requirement

Performance Requirement

Wi-Fi Performance| ● IEEE Wireless LAN standard: IEEE802.11n, IEEE802.11g, IEEE802.11b
● Data Rate:
IEEE 802.11b Standard Mode:1,2,5.5,11Mbps
IEEE 802.11g Standard Mode:6,9,12,18,24,36,48,54 Mbps IEEE 802.11n: MCS0~MCS7 @ HT20/ 2.4GHz band
MCS0~MCS7 @ HT40/ 2.4GHz band
● Sensitivity:
HT40 MCS7: -70dBm@10% PER(MCS7) /2.4GHz band HT20 MCS7 :-71dBm@10% PER(MCS7) /2.4GHz band
● Transmit Power:
IEEE 802.11n: 16dBm @HT20/40 MCS7 /2.4GHzband IEEE 802.11g: 16dBm @54MHz
IEEE 802.11b: 18dBm@11MHz
● Wireless Security: WPA/WPA2, WEP, TKIP, and AES
● Working mode: Bridge, AP Client
● Range: 50 meters maximum, open field
● Transmit Power:17dBm
● Highest Transmission Rate: 300Mbps
● Frequency offset: +/- 50KHZ
● Frequency Range (MHz): 2412.0~2483.5
● Low Frequency (MHz): 2400
● High Frequency (MHz): 2483.5
● E.i.r.p (Equivalent Isotopically Radiated power) (mW)<100mW
● Bandwidth (MHz):20MHz/40MHz
● Modulation: BPSK/QPSK, FHSSCCK/DSSS, 64QAM/OFDM
Bluetooth Performance| ● TX Power: 19.5dBm
● Range: 120 meters maximum, open filed
● Receiving Sensibility: -92dBm@0.1%BER , 1Mbps
● Frequency offset: +/-30KHZ
● Frequency Range (MHz):2401.0~2483.5
● Low Frequency (MHz):2400
● High Frequency (MHz):2483.5
● E.i.r.p (Equivalent Isotopically Radiated power) (mW)<10mW
● Bandwidth (MHz):2MHz
● Modulation: GFSK

Regulatory & Compliance

1 FCC Yes
2 ESD Testing Yes
3 RF Antenna Analysis Yes
4 Environmental Testing Yes
5 Reliability Testing Yes
6 IEC 60601-1-2 Yes

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device and its antenna(s) must not be co-located or operation in conjunction with any other antenna or transmitter.

Radiation Exposure Statement
To maintain compliance with FCC’s RF Exposure guidelines, This equipment should be installed and operated with minimum distance of 20cm from your body.

Floor 8 | Building A Wan Tong Center | HangZhou 310004 | China
Tel: +86 -571 -86769027/88810480
Website: www.dusuniot.com
www.dusunremotes.com
www.hzdusun.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

ZHEJIANG User Manuals

Related Manuals