Clean Air Optima CA-607W Smart Ultrasonic Humidifier User Manual

June 27, 2024
Clean Air Optima

Ultrasonic Humidifier Clean Air Optima® CA-607W Smart
User manual
Clean Air Optima CA 607W Smart Ultrasonic Humidifier -
Cover
Find more languages on: www.cleanairoptima.com/info/manuals

Read these instructions carefully before you start using the Ultrasonic Humidifier and keep the manual for future reference.
© Copyright: Clean Air Optima


CA-607W Smart Ultrasonic Humidifier

CA-607W Smart / Main unit

CA-607W Smart / Display

Thank you for purchasing the Clean Air Optima® Ultrasonic Humidifier CA- 607W Smart.
We wish you many years of healthy indoor air with this efficient and effective product.
These instructions describe the safety precautions to be observed during operation. They are meant to prevent injuries and to avoid damaging the device.

Description of the device
The device consists of the following main components:

  1. Mist nozzle
  2. Handle
  3. Water tank
  4. Float
  5. Aroma box
  6. Power cord
  7. PTC heating element
  8. Water tank lid and filter

Safety warnings

This device may only be used in accordance with these safety instructions. Take the following steps to minimize the risk of personal injury caused by for example electric shocks or fire.

  1. Only for indoor use. Do not use or store outdoors.
  2. Use proper voltage: AC 220V – 240V, 50/60Hz
  3. The inner ultrasonic transducer is highly sensitive. Do not touch it with bare fingers or scrape it with metal tools, or it will reduce mist output. When cleaning this area please use a small cleaning brush, cotton swab or tooth brush. Do not use hot water as it may damage the misting parts.
  4. The device is not intended to be used by children or persons with reduced physical-, sensory- or mental capabilities, unless they are supervised by a person responsible for their safety.
  5. Children should be kept away unless continuously supervised.
  6. To safely use the device, put it in a steady, horizontal position. Do not move while using.
  7. To prevent interference and damage to other electronic devices, this machine should be placed at least 1 meter away from a computer, television, radio or other electronic equipment.
  8. Do not use the device when there is visible damage on the electrical cord or on the device itself. Do not repair the device yourself in case of damage. Never pull the device by its cord. If the power cord is damaged, then it must be replaced by an authorized service person to prevent electric shock or fire.
  9. Repairs may only be performed by authorized service personal. Do not try to repair the device yourself to prevent electric shock or fire.
  10. Always remove the plug from the socket when the device is not being used or when you clean internal or external parts of it.
  11. Remove the water tank before moving the device.
  12. Only use power cords provided.
  13. Do not use the device in rooms where inflammable liquids or gases are stored, close to heat sources or in particularly humid rooms like the bathroom, shower or swimming pool.
  14. To prevent malfunctions, never insert strange objects into the device.
  15. Never dissemble or replace the device’s inner parts.
  16. Do not place the device in direct sunlight, to avoid that the device discolours.
  17. Never immerse the unit in water or other liquids.
  18. Do not touch the power cord with wet hands.
  19. Do not touch the warm mist closely.
  20. Clean and dry the device before storage (including the removal of all water from the inside of the device). Store the machine in a cool and dry place outside the reach of children.
  21. Do not clean the water sink when the water is still hot.
  22. Use, maintain and clean the device as described in this manual.

Operating instructions

Before getting started, remove the Clean Air Optima® CA-607W Smart from its box and allow it to become accustomed to the room temperature for at least 30 minutes especially if the machine is cold from the outside air. Place the device on a solid, level and front waterinsensitive surface, approx. 60 cm from the floor and at least 20 cm from the wall.
The CA-607W Smart is designed to operate at temperatures between 5 -40 ºC and relative humidity of less than 80%. To get started, grasp the water tank by the handle at the top and  lift from the base. Next, flip the tank over and unscrew and remove the water tank lid and filter.

Clean Air Optima CA 607W Smart Ultrasonic Humidifier - Operating
instructions 1

Then place the water tank under the faucet for filling, grasping it from the handle under the water tank. Fill the tank with tap water (or other clean water source with water  temperature under 40ºC), re-insert the lid and filter. Flip the water tank once again until it is on the right side up. Ensure that the basin is clean and then carefully place the water tank back on the lower body.
Wait a few seconds until the water tank lid starts to release water into the basin. You will hear a bubbling sound as the air enters the water tank. Plug the power plug into a suitable power outlet, a signal sounds to indicate that your device is in standby mode. If the humidifier is switched on/off, the value for humidity will now be displayed.

Power Button:
Press the Power Button to activate the humidifier. The machine is now operating in manual mode. It will release cool mist on a constant basis with the mist intensity level  automatically set to medium.

Manual Button:
The Manual Button changes the mist level (low, medium, high). There are 3 levels of mist output available.

WIFI:
WIFI indicator.

Humidity Button:
Pressing the Humidity Button, you can select the desired humidity level by pressing this button repeatedly until the required humidity level is displayed (from 40% to 80% in increments of 5%). Once you select your desired humidity level, simply stop pressing the button and your humidity level will be set.
When the humidity level in the room reaches the set humidity level, the machine will go into automatic sleep state and stop producing mist after 1 minute. When the room’s actual humidity level drops below your set humidity level, then the machine will start producing mist again.

Mode Button:
Pressing the Mode Button once, this will activate the Sleep mode, press 2 times for Auto, press 3 times for Baby, press 4 times for Health.
(Sleep-Auto-Baby-Health-Sleep…..).

Sleep Mode:
When the sleep mode is activated, the display will turn off in 10 seconds. Only the sleep mode light is on.

Auto Mode:
Depending on the temperature, the humidifier sets the optimum humidity

Temperature of the air, degrees Celsius Humidity %
19 and lower 65
20-21 60
22-23 55
24-25 50
26-27 45
28-29 40

a. The optimal humidity levels with different temperatures are taken from the data base of the device.
b. The device works at maximum power until the optimal humidity is achieved.
c. If the optimal humidity is achieved, then the humidification will stop.
d. The device checks the accordance of the temperature level and the humidity level every 10 minutes.

Baby Mode:
When the Baby Mode is activated, the device turns on the function of warm mist & UV-Light and starts to achieve 55% humidity at maximum power. If the 55% humidity is achieved, then the humidification will stop. The device checks the humidity level every 10 minutes.

Health Mode:
When the Health Mode is activated, the device turns on the function of warm mist & UV-Light, it will calculates the optimal humidity and starts to achieve it at maximum power.
The optimal humidity in Health Mode is calculated as in the Auto Mode, the only difference is that the device add 5% to the result.

Example:
Optimal humidity in Auto Mode = 50%, Optimal humidity in Health Mode = 50 + 5 = 55%
When the optimal humidity level is achieved, then the humidification will stop. The device checks the accordance of the temperature level and the humidity level every 15 minutes.

Negative Ion Button:
Pressing the Negative Ion Button will activate the negative ion generator with a total capacity of > 3.000.000 negative ions / cm³ that are spread through out the entire room and thereby neutralize pollutants and smells. Negative ions attach onto dust particles, microorganisms and other unwanted particles in the air and connect them to each other. This way, the particles become heavier than air and fall onto the ground so that you can no longer breathe them in.
Negative ions are most found in the forest, mountains and by the sea. Negative ions ensures fresh and healthy air.

Timer Button:
Pressing the Timer Button sets the timer. The timer function determines how many hours the humidifier will operate. You can set the timer simply by pressing it once for each hour that you would like to run the device. The timer can be set from 1 hour to 12 hours. As time passes, the time value decreases until it goes to 00:00 and the device shuts off.

Heating Button:
Pressing the Heating Button activates the warm mist function and is shown on the LED display with three wavy vertical lines. The water is heated in the basin by a PTC heating element and will be heated up by over 65 degrees for killing effective bacteria (Legionella). Heating the water makes the mist output finer for faster and more efficient humidification.

UV-Light Button:
Hold the UV-Light Button for 3 seconds, the device starts the UV Sterilization function, which kills the bacteria in the mist output airflow, bevor the mist enters into the room. The UV-Light icon is shown on the LED display. Press the button again and hold it for 3 seconds to stop the UV-light function.

Automatic shutdown when water tank is empty

Should the water tank be empty, a threefold acoustic signal sounds. The corresponding symbol lights up in the display while the remaining indicators go out. The device will automatically stop humidifying. In this case, turn off the device with the ON / OFF button. Let the device cool down before pouring any more water in the tank.
Caution: The device and the water in the nebulisation chamber (basin) might be very hot. When lifting the device or removing the water tank right after operation you risk scalding yourself with the hot water!
Ensure that the water tank is always completely refilled.

Operation with Clean Air Optima® App

Connectivity
Compatibility with smartphone and tablet:
iPhone, iPad and Android devices
Device connets via WiFi with App:
CleanAirOptima
Attention: The router must be set to the 2.4 GHz broadband. If the router is set to the 5.0 GHz, it is impossible to establish a connection.

Clean Air Optima CA 607W Smart Ultrasonic Humidifier - Operation with Clean
Air Optima App 1

Set up WiFi connection

  1. Download and install the “CleanAirOptima” App in the
    App Store or Google Play Store.

  2. Make an account and log in.

  3. The router must be set to the 2.4 GHz broadband. If the router is set to the 5.0 GHz, no connection can be established.

  4. Make sure Bluetooth is enabled on your smartphone.

  5. Plug the device into the power socket and switch it on. The WiFi indicator will blink. If the WiFi light does not blink, press the ‘MANUAL’ button for 5 seconds. Then the WIFI light will flash quickly. If the WIFI light blinks quickly, the device is ready to connect.

  6. Make sure that your smartphone or tablet is successfully connected to your WiFi network.

  7. Open the ‘CleanAirOptima’ App and click on ‘Add device’ . Your device is listed and you can select it. If not choose ‘Auto Scan’. Follow the on-screen instructions to connect the device to your network.

  8. Choose to add the Clean Air Optima® device on the App, follow the instructions in the App.

  9. When the device is paired, the WiFi indicator light stays on constantly.

  10. After the configuration is successful, you can use the Clean Air Optima® App to operate the device.

Note:

  • If your default network has changed, reset the WiFi connection, follow step 1 to 10 in the ‘Set up WiFi connection’ section.
  • If you want to pair multiple devices to your smartphone or tablet, you have to do this one after the other.
  • Make sure that the distance between your smartphone or tablet and the device is less than 5 meters and there are no obstacles. Also make sure you are in the same room as the device.

Reset the WiFi function:
– The device must be switched on.
– Reset the WiFi by pressing the ‘MANUAL’ button for 5 seconds, the indicator light of the WiFi will blink rapidly.

Connect devices to multiple phones

Note: First the other person needs to install the Clean Air Optima® App on his/her phone and create a new account.

Share the device with limited access:
You can choose to share 1 device with several persons.
This person will then have access, but will not be able to manage all the settings.

Follow the instructions below to share the device with several persons:

  1. Go to the relevant device.
  2. Go to the pencil or three dots in the top right.
  3. Select ‘Share device.‘
  4. Choose ‘Add sharing‘.
  5. Choose the sharing method e.g. via email, whatsapp, sms etc. and continue.
  6. The device will automatically appear in the Clean Air Optima® App with the other account.

Share device with full access:
You can add a person or several persons to your home management.
That person will then have access to all your devices that are already linked and has full rights and permissions. You will always remain the main administrator.

Follow the instructions below to add someone to your home management:

  1. Open the Clean Air Optima® App and go to ‘Me’.
  2. Then choose ‘Home Management’.
  3. Choose ‘Create a home’.‘
  4. Select the relevant ‘Home’ and ‘Add member‘.
  5. Choose the sharing method e.g. via email, whatsapp, sms etc. and continue.
  6. The corresponding ‘Home‘ will automatically appear in the Clean Air Optima® App of the person with whom you have shared your ‘Home‘.
  7. On the other account: Go to the home screen from the Clean Air Optima® App. Go to the top left and select the ‘Home‘.

Remote control

The buttons on your remote control:

1. Sleep mode
2. Auto mode
3. Baby mode
4. Health mode
5. Desired humidity
6. Min. / Max.| 7. ON / OFF
8. Timer
9. Heating
10. UV-Light
11. Negative ions
12. WIFI
---|---

Replacing batteries in the remote control

  1. Open the battery cover at the back side of remote control to place the battery. (see Picture1).
  2. To place the battery: there is a “security tab” at the bottom of the remote control that you first have to slide to the right and then pull out the battery holder. (see Picture 2).  Insert the battery with the correct polarity. (see Picture 3).
  3. Push the battery cover back into the remote control.

Clean Air Optima CA 607W Smart Ultrasonic Humidifier - Remote control
2

Preparation Clean Air Optima® Water Filter W-01W

The Water Filter W-01W reduces the limescale in the water and the undesirable emission of limescale particles into the room surroundings. Effective for one to three months, depending on the water hardness. Hard tap water accelerates saturation of the granulate faster so that the Water Filter W-01W must be replaced earlier.

  1. Rinse the Water Filter W-01W for 2 minutes under cold running tap water.

  2. Screw the Water Filter W-01W to the water tank lid.

Determining water hardness:

  1. Dip the enclosed test strip into a glass of cold tap water for 1 second.

  2. Read the water hardness teststrip after one minute.

  3. Refer to the table to determine the expected duration of the Water Filter W-01W.
    Dispose of the saturated Water Filter W-01W with your regular household waste.
    The Water Filter W-01W should not be used longer than specified.
    You can order the Water Filter W-01W in our online store at www.cleanairoptima.com

Replacing the Clean Air Optima® Water Filter W-01W

The Clean Air Optima CA-607W Smart is equipped with a filter lifespan surveillance mechanism that signals that the water filter have to be replaced after 400 working hours. To show that the Water Filter W-01W need to be replaced, the humidifier emits a double zero indicator light. Reset the timer for the water filter by pressing and holding the power button for about 3 seconds. If the indicator light goes out, the timer has been successfully reset.

Placing/Replacing the Clean Air Optima® Silver Ion SI-01

The Silver Ion SI-01 uses the anti-microbial effect of silver, it prevents the growth of bacteria and smells in the water. The Silver Ion SI-01 even works when your humidifier is switched off, so the water stays fresh.
Replace the Silver Ion SI-01 at the start of the humidifier season or repace the Silver Ion SI-01 after one year of usage.

Replacing the Silver Ion SI-01:

  1. Grasp the water tank by the handle at the top and lift from the base.

  2. Take out the used Silver Ion SI-01.
    Clean Air Optima CA 607W Smart Ultrasonic Humidifier - Remote control
7

  3. Insert the new Silver Ion SI-01.

Dispose of the Silver Ion SI-01 with your regular household waste.
The Silver Ion SI-01 should not be used longer than specified.
You can order the Silver Ion SI-01 in our online store at www.cleanairoptima.com

Aromatherapy

Activating the aroma function:

  • Remove the aroma tray from the bracket.
  • Pour 5 – 10 drops of Clean Air Optima® essential oil onto the sponge.
  • Put the aroma tray back into the bracket.
  • When you turn on your air humidifier, the aroma function will be activated.
  • If you want to deactivate the aroma function, or should the device not be in use for extended periods of time, remove the aroma sponge from the compartment and wash it with a little of mild soap water. Let it dry completely before placingit back in the aroma compartment. Basically, the aroma sponge is reusable.

Important
In order to reach the best results and to enjoy your ultrasonic air humidifier as much as possible, we advise to read carefully the following instructions regarding the use of essential oils in the ultrasonic air humidifier CA-607W Smart.
Use of essential oils in the CA-607W Smart
Use our high quality essential oils and enjoy your personal aromatherapy! A scent sensation at its highest level!
You can find high quality essential oils with many different scents in our assortment. They perfectly fit to the ultrasonic air humidifier CA-607W Smart and have been specially developed for the use with this ultrasonic humidifier:

You can order the Essential Oils in our online store at www.cleanairoptima.com

Warning!
The use of other essential oils not made for this air humidifier or other additives (for example: fragrances and water purification products) can damage the air humidifier and must  NOT be used! Never put other pure essential oils or other additives into the water tank resp. the waterbasin! Even a small quantity can damage the plastic and cause cracks. The  material is not made for the use of additives. One drop is enough to damage the water tank/ waterbasin and disable the device. Devices that are damaged through additives are excluded from the guarantee.

Cleaning and maintenance

You can ensure that your Clean Air Optima® CA-607W Smart humidifier will provide years of trouble-free operation by following a few simple maintenance procedures. If your water is hard and contains high concentrations of calcium and other minerals, over time white dust (lime) will start to settle on the various surfaces in the room. A white deposit (lime scale) will also form in the water basin, on the transducer/PTC heating element and on the interior of the water tank.
Lime deposits will impair the proper functioning of the transducer/PTC heating element and the efficient hygienic humidification of the unit.

We recommend the following

  1. Clean the transducer/PTC heating element and the water basin once a week if you use the appliance daily with Clean Air Optima® Cleaner & Descaler*.
  2. As soon as the water tank needs refilling, pour out any remaining water and fill it with fresh water.
  3. Clean the entire device and keep all parts completely dry when the device is not in use.

Clean Air Optima CA 607W Smart Ultrasonic Humidifier - Cleaning and
maintenance 1

Specially developed for Clean Air Optima® humidifiers:

  • Not aggressive
  • Protects plastic and ceramic materials of the humidifier
  • Odour neutral
  • Cleans & descales quickly and thoroughly
  • Biodegradable
    You can order the Clean Air Optima® Cleaner & Descaler from our online shop at www.cleanairoptima.com.

Clean Air Optima CA 607W Smart Ultrasonic Humidifier - Cleaning and
maintenance 2

Cleaning the transducer/PTC heating element and water basin
Unplug the device.
During cleaning and descaling, the device must not be used.
Remove any splashes of Clean Air Optima® Cleaner & Descaler from work surfaces or the outside of the device with a soft, damp cloth.

  1. Pour two capfuls of Clean Air Optima® Cleaner & Descaler into the water basin (one onto the surface of the transducer and one onto the PTC heating element) and leave for  between two and five minutes.

  2. Carefully remove the mineral (lime) layer from the surface of the transducer and PTC heater with a small brush, cotton swab or toothbrush.
    Caution: never use sharp or hard objects to clean the transducer/PTC heating element.

  3. Then add water up to the rim of the water basin and leave for a minimum of 30 and a maximum of 60 minutes.

  4. Rinse the transducer/PTC heating element and water basin thoroughly with water.

  5. If there are still traces of limescale visible, we recommend that you repeat the cleaning and descaling process.

  6. Clean the inside of the water tank with a mild detergent and rinse with clean water.
    After cleaning and descaling, your device is hygienically clean, free of limescale, free of bacteria, free of viruses and immediately ready for use again.

Please note:
For cleaning and descaling, the device must be turned off/unplugged, so that no acid is released into the air via aerosols through ultrasonic misting.

Cleaning the watertank
The water must be changed regularly in the water tank. The water should not remain in the water tank for more than 3 days.

  • Please note that high humidity can promote the growth of biological organisms in the environment.
  • Do not let the area around the humidifier get damp or wet. If moisture occurs, turn down the humidifier output. If the humidifier output volume cannot be reduced, use the humidifier intermittently. Do not allow absorbent materials such as carpeting, curtains, drapes or table cloths to become damp.
  • Pull the plug out of the socket during filling and cleaning.
  • Never leave water in the tank when the appliance is not in use.
  • Empty and clean the humidifier before storage. Clean the humidifier before next use.
  • Clean the inside of the Water Tank with a mild detergent and rinse with clean water.


Warning:
Microorganisms that may be present in the water or in the environment where the device is used can grow in the water tank and be blown into the air. This can lead to health risks if the water is not changed and the tank is not properly cleaned every 3 days.

Troubleshooting

The following is a troubling shooting guide to help you solve any issues that you may have using the Clean Air Optima® Ultrasonic Humidifier CA-607W Smart.

Problem Possible Cause Solution
No mist diffused. Power plug not plugged in.

ON / OFF button not activated.
Empty water tank.
Not enough water in tank.| Plug in device.
Press ON / OFF button.
Fill tank with water.
Refill tank with water.
The mist has a strange odour.| A new device.
It either has dirty water or the water has been stagnant too long.| Remove the water tank, unscrew the lid and let it air out in a cool area for 12 hours.
Clean the water tank and refill with clean water.
The volume of spray mist is too low.| Too much mineral scale in the water basin and on the transducer.
Water is too dirty or water was kept too long in the tank.| Clean the water basin and the transducer with:
Clean Air Optima” Cleaner & Descaler.
Clean the water tank and refill with clean water.
Device is noisy.| Water tank not positioned correctly.
Not enough water in the water tank.
Device is on an unstable surface.| Correctly position water tank on the base.
Refill water in the water tank
Place device on solid and even ground.
Spray mist is coming out of the area around the mist nozzle.| There are gaps between the housing around the nozzle and the top of the water tank.| Remove the nozzle from the top of the water tank and clean with a damp cloth. Reattach to the water tank.
Operation with Clean Air Optima, App does not work.| Smartphone or tablet is not
connected to WiFi network.
The device has no connection to the network.| Turn on the device and reset the WiFi on the device by pressing the Manual mode button for 5 seconds. t he indicator light of the WiFi will blink. Than follow step 3 to 10 from chapter Operation with Clean Air Optima’ App.

If your water is very hard (containing abnormally high levels of minerals) the humidifier may produce white dust. This is not a malfunction. The solution would be to replace the  Water Filter W-01W more often or use softer water, like distilled water. Or we can recommend Clean Air Optima Air Washers, more info in our online store www.cleanairoptima.com

WARNING!
If the above recommended solutions do not work, please contact Clean Air Optima technical support at the telephone number for your region. Do not attempt to disassemble,  reassemble, or repair the device as this may void the warranty.

Specifications

Model CA-607W Smart
For rooms up to 65m²  / 160m³ / 699ft²
Rated voltage 220V – 240V, 50/60Hz
Rated power 25W – Max. 105W
Capacity airhumidification Min. 120 ml/h – Max. 480 ml/h
Active oxygen <0.05 ppm
Sound level Silent fan < 25dB(A)
Dimensions 230 x 150 x 370 mm
Weight 3,4 kg
Water tank 5,5 L
Colour Pearl white with smoked glass water tank
Complies with EU regulations CE / WEEE / RoHS

Ask your retailer or your municipality for updated information regarding the disposal of the packaging and of the device.

Symbols Meaning
This symbol means that the filter must be checked and cleaned if necessary

before the appliance is started up. Replace the filter every 2 to 3 months.
| This symbol means that the water tank should be cleaned every 3 days. Change the water in the water tank every 3 days.
Remove the plug from the socket before you start cleaning.

Service

Warranty Certificate for the Clean Air Optima® Ultrasonic Humidifier CA- 607W Smart.
Date of purchase: …………………………………………………………………………………………
Customers name: …………………………………………………………………………………………
Address: …………………………………………………………………………………………………….
Telephone: ………………………………………………………………………………………………….
Email: ………………………………………………………………………………………………………..
Seller’s name: ………………………………………………………………………………………………
Address: …………………………………………………………………………………………………….

  1. Please fill in completely this Warranty Certificate. Send it with the invoice and the unit, postage pre-paid and using the original packing box, to your distributor. Make sure to include the appropriate return postage for the package.
  2. Please enclose a short description of the damage, fault or malfunction, and the circumstances under which these problems arose.

The Clean Air Optima® Ultrasonic Humidifier CA-607W Smart is subjected to strict testing procedures before leaving the factory. If within 2 years from the date of purchase the product does not perform according to the specifications, because of factory defects, the purchaser is entitled to free repairs or replacement of parts upon presentation of this warranty  (provided that the malfunction or damage to the device and/or parts occurred under normal operating conditions). What is covered: All parts defective in material and  workmanship. For how long: two years from purchase date. What we will do: Repair or replace any defective parts.

Other Conditions
The provisions of this warranty are in lieu of any other written warranty whether express or implied, written or oral, including any warranty of merchantability or fitness for a  particular purpose. The manufacturer’s maximum liability shall not exceed the actual purchase price paid by you for the product. In no event shall the manufacturer be liable for special, incidental, consequential, or indirect damages. This warranty does not cover a defect that has resulted from improper or unreasonable use or maintenance, faulty assembly, accident, natural catastrophes, improper packing, or unauthorized tampering, alteration, or modification as determined solely by us. This warranty is void if the label bearing the serial number has been removed or defaced.
Never put other pure essential oils or other additives into the water tank resp. the waterbasin! Even a small quantity can damage the plastic and cause cracks.

Thank you for reading!

| Share your feedback about the Clean Air Optima®
Ultrasonic Humidifier CA-607W Smart on: www.cleanairoptima.com
---|---
| For frequently asked questions about the CA-607W Smart go to:
www.cleanairoptima.com and search for the CA- 607W Smart.
| Download PDF instruction manual on: www.cleanairoptima.com/info/manuals
| Watch all Clean Air Optima® Product animation video’s on: www.youtube.com


Clean Air Optima International B.V.

David Ricardostraat 9-7 / 9-9 | 7559 SH Hengelo (ov)
The Netherlands | Phone: +31 (0) 74 – 2670145
Clean Air Optima Germany GmbH
Enschedestraße 14 | 48529 Nordhorn | Germany
Phone: +49 (0) 5921 879-121
E-mail: [email protected]
Internet: www.cleanairoptima.com

A guarantee for healthy indoor air quality!
Designed in Germany
© 2023 Clean Air Optima
®, All rights reserved, Made in P.R.C.

Clean Air Optima CA 607W Smart Ultrasonic Humidifier - QR Code
1More info: www.cleanairoptima.com
Trademarks owned by: Clean Air Optima Germany GmbH,
Enschedestraße 14, 48529 Nordhorn, Germany

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Clean Air Optima User Manuals

Related Manuals