PROCET PT-PSE109GMN-A-S PoE Injector User Manual
- June 25, 2024
- PROCET
Table of Contents
PT-PSE109GMN-A-S PoE Injector
User Manual
Declaration
Copyright ©2024 Creative Lianjie Network Technology Co.Ltd All rights
reserved.
This document belongs to PROCET company. It is not allowed to reproduce and
modify without the original author’s permission. It is PROCET’s policy to
improve its products as new technology components, software , and firmware at
any time. PROCET, therefore, reserves the right to change specifications
without prior notice.
Please follow WEEE (Waste Electrical and Electronic Equipment) disposal
instructions for old electronic products. Please do not dispose of the old
product in your general household waste bin.
The symbol indicates that the product should not be discarded as unsorted
waste but must be sent to separate collection facilities for recovery and
recycling.
Overview
PT-PSE109GMN-A-S, a single port fiber PoE Injector with Managed Ethernet
function. Supports IEEE 802.1Q VLAN and port-based VLAN .
We can access and manage the device via web browser, including IP
configuration, port configuration, VLAN configuration, PoE configuration,
device control, etc. We can also view device information such as switch
status, port status, and PoE status etc. In addition, the PoE port enables
remote control of the device’ on/off and reset status.
This model has a 1000BASE-X SFP Interfaces, offers a unique solution to
powering long range installations, where the data input comes over fiber.
The PoE output port delivers 55V/2.2A power up to 121W(max) for remote PD via
full 4 pairs with 4KV surge protection at 10/100/1000Mbps of data speed. It
supports terminal equipments with IEEE802.3af/at, PoE++, IEEE802.3bt standard.
such as wireless APs, IP cameras, base stations, gateways, and other high-
power Ethernet backhaul devices.
Industrial design, when cover with waterproof case can be used for outdoor
application. It works like a switch, the data is interoperable among LAN port,
PoE port and SFP port.
Appearance
-
(Indicator)
Lit:Normal
Flashing:Detecting
Light off: Abnormal-
LAN Port
Yellow:Data Indicator
Green:Unuse -
SFP Indicator
-
Power Indicator
-
PoE Port
Yellow:Data Indicator
Green:Load Indicator -
SFP Port
-
Fixing holes
-
GND Terminal
-
AC Power Port
-
Specification
Model | PT- PSE109GMN- A- S |
---|---|
Input | 100- 240Vac 2.0A 50/60Hz |
PoE Standard | Passive |
PoE Power Pins | 1/2/3/6(+) & 4/5/7/8(-) |
Output | 55Vdc 2.2A |
Operating Temp. | 0°C to 40°C |
Network Protocol | IEEE802.3i/ IEEE802.3u/ IEEE802.3ab REEE802.3z |
Data Rates | LAN:10/100/1000Mbps SFP:1G |
Immunity | IEC 60068-2- 6(Vibration) IEC 60068- 2-27(Impact) IEC 60068- 2- |
32(Free Fall)
Dimensions &NW| 213.9mm X 134.0mm X 41.0mm 1104g
Troubleshooting
Failure Phenomena | Cause Analysis | Solutions |
---|---|---|
Power LED Light off | Not plugged in / no power | Plug in the power cord |
Poor Power outlet
Poor Power cord
Power cable is not plugged in firmly| Check if the socket connection is loose,
if the AC cable is damaged, or if the power supply is abnormal.
Device issues| Device replacement
Load Indicator Light Off| Poor network cable contact or network cable
failure.| Re-plug the network cable or replace the network cable.
PD Damage| PD replacement
Data Transmission
Abnormality| Check if the total length of the network connection cable exceeds
100 meters.| Shorten the connection distance, or add an extender/ repeater.
LAN port signal source malfunction| Check if the switch working properly.
Ethernet data transmission failure| Check if the cable comply with the
EIA/TIA56813 or 568A. Change good network cable if the previous cable is poor.
Caution
- Please read the instructions carefully and follow the standard operating procedures before using.
- Please place it in a well-ventilated and dry area, and it is for indoor use only.
- Connect the power cable’s trapezoidal plug into the rear of the unit. On the other end of the power cable plug into a standard grounded wall outlet for safety.
- Connect a CAT5/5e/6 cable from your non-PoE router/switch into the unit’s LAN port, for Ethernet transfer if needed.
- Connect a CAT5e/6 cable with the RJ45 connector into the RJ45 socket labeled PoE. On the other end of the CAT5e/6 cable, connect to your PoE Device (such as IP Cameras etc)
- The total Ethernet cable length can not exceed 100 meters.
- The device must be placed on a stable surface ,preferably affixed and mounted permanently. Do not leave it “dangling” and use plugged-in cables in tension as support. Drops, falls, and impacts experienced by the injector can compromise the internal components & cause premature failure.
- Do not place heavy objects on top of this injector. Allow at least 5cm of clearance on all sides of the device for heat ventilation / natural convection.
- Do not use with 24V DC PDs. This unit outputs 55V, which may damage 24V DC input devices (due to voltage mis ‐match).