samsara CBL-AG-BPWR Powered Asset Gateway Installation Guide
- June 25, 2024
- Samsara
Table of Contents
- samsara CBL-AG-BPWR Powered Asset Gateway
- Product Usage Instructions
- CABLE DIAGRAM
- WHAT YOU’LL NEED (STANDARD LOCATION INSTALLATION)
- ACC-AG-BHZB ACCESSORIES (OPTIONAL HAZARDOUS LOCATION INSTALLATION)
- IMPORTANT SAFETY AND USE INFORMATION
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
samsara CBL-AG-BPWR Powered Asset Gateway
Specifications:
- Model : CBL-AG-BPWR
- Supported Languages: EN, FR, FR-CA, DE, ES, NL
- Support Website: samsara.com/support
- Fleet App: samsara.com/fleet-app
- Release Date: 2024-04-29 R05
Product Usage Instructions
Standard Location Installation:
- Verify that the cable has adequate clearance to reach the Asset Gateway (AG) and the electrical connection.
- Ensure that the AG has a clear view of the sky for optimal cellular and GPS connectivity.
- Avoid installing the device within metallic structures like metal trailers as it can impact connectivity.
- Attach the gateway to the asset using the provided self-drilling screws with a maximum torque of 1.4 Nm (12.4 lbf-in).
- If using your own screws, follow the recommendations for screw size to prevent damage to the device mounting tabs.
Hazardous Location Installation:
- Attach the mounting plate with included self-drilling screws to the mounting surface.
- Assemble the Asset Gateway and cover with the cable plugged in. Fasten with the included machine screws.
- Wire the included 2A fuses between the cable and power source(s) following safety precautions.
Trailer Installation:
- Connect the cable to the 7-way connector on the trailer.
- Confirm wire colors and labels as they may vary by manufacturer.
Powered Equipment Installation:
- Wire the Input 0 wire to key-on power or any signal for tracking usage.
- Follow the wire colour guide provided for different power sources.
After connecting the Asset Gateway to power, verify the connection in the Samsara Dashboard. The LED will turn green upon successful connection.
Important Safety and Use Information:
This installation guide serves as a reference and does not constitute a
warranty. Installers are responsible for complying with all applicable laws
and ordinances during hardware installation.
CABLE DIAGRAM
WHAT YOU’LL NEED (STANDARD LOCATION INSTALLATION)
ACC-AG-BHZB ACCESSORIES (OPTIONAL HAZARDOUS LOCATION INSTALLATION)
-
Activate your Asset Gateway. This can be completed on the Samsara Dashboard or on the Samsara Fleet App. You can also follow the link in your Order Shipped email.
-
standard location installation
-
When selecting a location for your device, reference the following tips:
-
Verify that the cable has adequate clearance to reach the AG and the electrical connection. Ensure that the AG has a clear view of the sky. Avoidinstalling the device within metallic structures, such as within metal trailers.
-
Placement in such structures may adversely impact device cellular and GPS connectivity.
-
Attach the gateway to the asset using the provided #6 self-drilling screws with maximum torque of 1.4 Nm (12.4 lbf-in). If you choose to fasten the device with your own screws, use these recommendations for screw size to avoid damage to the device mounting tabs.
-
If you are installing at a hazardous location, use the following recommendations:
Attach the mounting plate with included self-drilling screws to the mounting surface. With cable plugged in, assemble the Asset Gateway and cover. Fasten with the two included machine screws. Wire the included 2A fuses between cable and power source(s).
WARNING — EXPLOSION HAZARD. DO NOT CONNECT OR DISCONNECT WHEN ENERGIZED. DO NOT DISCONNECT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA IS FREE OF IGNITIBLE CONCENTRATIONS. -
When installing on a trailer, connect the cable to the 7-way connector . Confirm wire colors and labels as they may vary by manufacturer.
-
If connecting to a different power source, follow the wire color guide below:
-
WHITE — GROUND
-
BROWN — POWER (RUNNING LIGHTS)
-
BLUE — POWER (ABS) GREEN-WHITE — INPUT (OPTIONAL)
-
For a powered equipment installation, wire the “Input 0” wire to key-on power or any signal where you would like to track usage.
Follow the wire color guide below: -
BLUE — POWER (ABS)
-
WHITE — GROUND
-
GREEN -WHITE — IGNITION BROWN — POWER (RUNNING LIGHTS) (OPTIONAL)
-
After you connect the Asset Gateway to power, verify the connection in the Samsara Dashboard. After a successful connection, the LED will turn green
IMPORTANT SAFETY AND USE INFORMATION
-
This installation guide contains typical information specific to products manufactured at the time of its publication. The contents of this guide do not constitute a warranty and are for reference only. Consult applicable local laws and ordinances to determine any installation restrictions. It is the installer’s responsibility to comply with all applicable laws and ordinances when installing this hardware.
-
Do not attempt to repair this product, use any third-party replacement parts with this product, or otherwise modify this product except in accordance with product manuals or as otherwise instructed by Samsara. Failure to do so may cause property damage, lead to physical injury, or void your product warranty.
-
Any installation not in accordance with the instructions in the installation guide or otherwise in the Documentation or other than as described by the relevant IP rating or recommended operating conditions may result in physical injury or property damage. Failure to follow these directions could result in serious injury or death.
-
This hardware and any associated software may not be compatible with third-party products and/or services and may interfere with the operations of or void warranties for such third-party products and/or services.
-
Do not install or adjust hardware while driving or operating the vehicle. Do not install this hardware in a location that could interfere with the driver’s visibility or operation of vehicle controls. Do not install this hardware on or near airbag panels or within the working range of an airbag.
-
Do not install hardware while the vehicle is unsecured. Do not install hardware while the vehicle is turned on unless instructed to turn on the vehicle by the installation guide. Failure to follow installation instructions may cause serious physical injury, damage to the vehicle or the hardware, and void vehicle or other third-party product warranties.
-
Batteries in the hardware may have a shorter life span if not used in accordance with instructions. Do not short circuit, crush, disassemble, heat above 60°C/140°F, incinerate, or expose the battery or its contents to water. Do not remove the battery from the hardware to recharge or for any other reason, including disposal. Do not solder directly to the battery cell. Do not use it if the battery appears damaged.
-
This product includes capacitors and batteries which may present a potential fire, explosion, electric shock, or burn hazard. Do not touch or come into close proximity to any capacitors within this hardware.
-
Keep this hardware between -40°C/-40°F to 60°C/140°F externally powered, -20°C/-4°F to 60°C/140°F discharging on battery,
0°C/32°F to 45°C/113°F charging. Failure to keep this hardware in the specified temperature range may result in safety risks. -
Failure to follow mounting instructions may create risk of physical injury or property damage from falling objects. If mounting the hardware to a building wall, check for wiring or plumbing before drilling any holes.
-
After installation, this product will be able to charge batteries at any moment.
CAUTION SYMBOL, PLEASE REFER TO WARNINGS DC SYMBOL, TO INDICATE DIRECT CURRENT
References
Read User Manual Online (PDF format)