samsara CBL-AG-BEQP Asset Gateway Installation Guide

June 1, 2024
Samsara

samsara CBL-AG-BEQP Asset Gateway

samsara CBL-AG-BEQP Asset Gateway

CABLE DIAGRAM

Cable Diagram

WHAT YOU’LL NEED (STANDARD LOCATION INSTALLATION)

  • 1x Asset Gateway

  • 1x Equipment Cable
    What You’ll Need \(Standard Location Installation\)

  • 2x Self-drilling screws

  • 7x Butt splices

  • 3x Ring terminals (RV 1.25-6)

  • 2x Ring terminals (RV 1.25-10)

  • 3x Zip ties

ACC-AG-BHZB ACCESSORIES (OPTIONAL HAZARDOUS LOCATION INSTALLATION)

  •       1x Mounting plate

  • 1x Cover

  • 2x Machine screws

  • 2x In-line fuse

Activate your Asset Gateway. This can be completed on the Samsara Dashboard or on the Samsara Fleet App. You can also follow the link in your Order Shipped email.
Acc-ag-bhzb Accessories \(Optional Hazardous Location
Installation\)

standard location installation

Verify that the cable has adequate clearance to reach the AG and the electrical connection. When selecting a location for your device, reference the following tips:

Verify that the cable has adequate clearance to reach the AG and the electrical connection. Ensure that the AG has a clear view of the sky. Avoid installing the device within metallic structures, such as within metal trailers. Placement in such structures may adversely impact device cellular and GPS connectivity.
Acc-ag-bhzb Accessories \(Optional Hazardous Location
Installation\)

Attach the gateway to the asset using the provided #6 self-drilling screws with maximum torque of 7kgf-cm. If you choose to fasten the device with your own screws, use these recommendations for screw size to avoid damage to the device mounting tabs.

If you are installing at a hazardous location, use the following recommendations:
Attach the mounting plate with included self-drilling screws to the mounting surface. With cable plugged in,
assemble the Asset Gateway and cover. Fasten with the two included machine screws. Wire the included 2A fuses between cable and power source(s).
Acc-ag-bhzb Accessories \(Optional Hazardous Location
Installation\)

WARNING — EXPLOSION HAZARD. DO NOT CONNECT OR DISCONNECT WHEN ENERGIZED. DO NOT DISCONNECT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA IS FREE OF IGNITIBLE CONCENTRATIONS.

Connect the wires using the following pinout list as a guide:

Red cable (Power):
It is recommended to wire to a key switched source, such as an hour meter or oil pressure switch for internal
combustion engines.

Black (Ground):
Verify a ground point using a multimeter, typically a metal stud or bolt that makes a direct contact to the metal chassis.

Green-white (Input 1):
Use for tracking hours of operation. Input examples: hour meter, oil pressure switch, etc.

Blue-white (Input 2):
Use for tracking productivity or alerts. Input examples: hydraulic solenoid on belt loader to track productivity when compared to engine hours

Orange (Output):
Reserved for future use

Green (CAN Lo)/Yellow (CAN Hi):
Not currently supported for AG52. For AG26 only.
Helpful Links

After you connect the Asset Gateway to power, verify the connection in the Samsara Dashboard. After a successful connection, the LED will turn green.
Helpful Links

Green GPS & LTE OK
Blue No GPS, LTE OK
Red No GPS, No LTE
Yellow No LTE, GPS OK

IMPORTANT SAFETY AND USE INFORMATION

This installation guide contains typical information specific to products manufactured at the time of its publication. The contents of this guide do not constitute a warranty and are for reference only. Consult applicable local laws and ordinances to determine any installation restrictions. It is the installer’s responsibility to comply with all applicable laws and ordinances when installing this hardware.

Do not attempt to repair this product, use any third party replacement parts with this product, or otherwise modify this product except in accordance with product manuals or as otherwise instructed by Samsara. Failure to do so may cause property damage, lead to physical injury, or void your product warranty.

Any installation not in accordance with the instructions in the installation guide or otherwise in the Documentation or other than as described by the relevant IP rating or recommended operating conditions may result in physical injury or property damage. Failure to follow these directions could result in serious injury or death.

This hardware and any associated software may not be compatible with third party products and/or services and may interfere with the operations of or void warranties for such third party products and/or services.

Do not install or adjust hardware while driving or operating the vehicle. Do not install this hardware in a location that could interfere with the driver’s visibility or operation of vehicle controls. Do not install this hardware on or near airbag panels or within the working range of an airbag.

Do not install hardware while the vehicle is unsecured. Do not install hardware while the vehicle is turned on unless instructed to turn on the vehicle by the installation guide. Failure to follow installation instructions may cause serious physical injury, damage to the vehicle or the hardware, and void vehicle or other third party product warranties.

Batteries in the hardware may have a shorter life span if not used in accordance with instructions. Do not short circuit, crush, disassemble, heat above 60°C/140°F, incinerate, or expose the battery or its contents to water. Do not remove the battery from the hardware to recharge or for any other reason, including disposal. Do not solder directly to the battery cell. Do not use if battery appears damaged.

This product includes capacitors and batteries which may present a potential fire, explosion, electric shock, or burn hazard. Do not touch or come into close proximity to any capacitors within this hardware.

Keep this hardware between -40°C/-40°F to 60°C/140°F externally powered, -20°C/-4°F to 60°C/140°F discharging on battery, 0°C/32°F to 45°C/113°F charging. Failure to keep this hardware in the specified temperature range may result in safety risks.

Failure to follow mounting instructions may create risk of physical injury or property damage from falling objects. If mounting the hardware to a building wall, check for wiring or plumbing before drilling any holes.

After installation, this product will be able to charge batteries at any moment.

CAUTION SYMBOL, PLEASE REFER TO WARNINGS
DC SYMBOL, TO INDICATE DIRECT CURRENT

| QR
Code
---|---

CUSTOMER SUPPORT

samsara.com/support
© 2023 Samsara Inc.Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals