ZheJiang Guangwei Electric Tools Co Ltd EAD02 EV Charging Wallbox AC Charger Instruction Manual

June 1, 2024
ZheJiang Guangwei Electric Tools Co Ltd

ZheJiang Guangwei Electric Tools Co Ltd EAD02 EV Charging Wallbox AC

Charger

ZheJiang-Guangwei-Electric-Tools-Co-Ltd-EAD02-EV-Charging-Wallbox-AC-
Charger-PRODUCT

EV Charging Wallbox AC Charger

ZheJiang Guangwei Electric & Tools Co.,Ltd Building 7, NO,55th, Lingxiu Road Jiashan,Zhejiang Province,314100, China Made in China

INSTRUCTIONS PERTAINING TO A RISK OF FIRE OR ELECTRIC SHOCK

IMPORTANT SAFETY INSTRUCTIONS
WARNING – When using electric products, basic precautions should always be followed, including the following. This manual contains important instructions(blank space is to be filled in with applicable model numbers) that shall be followed during installation, opera­tion and maintenance of the unit. When the instructions are exactly the same for all models, specific model numbers are not required to be specified:

  • Read all the instructions before using this product.

  • This device should be supervised when used around children.

  • Do not put fingers into the electric vehicle connector.

  • Do not use this product if the flexible power cord or EV cable is frayed, has broken insulation, or any other signs of damage.

  • Do not use this product if the enclosure or the EV connector is broken, cracked, open,or shows any other indication of damage.
    Grounding instruction for plugged-in installation:

  • This product must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This product is equipped with a cord having an equipment grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

  • WARNING – Improper connection of the equipment-grounding conductor is able to result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the product is properly grounded. Do not modify the plug provided with the product – if it will not fit the outlet, have a proper outlet installed by a qualified electrician.”
    For hardwired installation:
    This product must be connected to a grounded, metal, permanent wiring system, or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the product.

CAUTION: To reduce the risk of fire, only connect your charger to a circuit with a branch circuit overcurrent protection of 125% of the selected max amperage setting of the device in accordance with the ANSI/NFPA 70 (US) and CSA C22.1 (Canada)

SAVE THESE INSTRUCTIONS

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. this device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installa­tion. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TY technician for help.

MPE Requirements
To satisfy FCC RF exposure requirements, a separation distance of 20 cm or more should be maintained between the antenna of this device and persons during device operation.
To ensure compliance, operations at closer than this distance is not recommended.

  • Application

    • EV charger is used to offer the AC power for the vehicle with an battery charger. EV charger can be assembled in all kind of parking lot public, company and community.
    • It is also can be assembled in all kind of large, medium and small charge station. It is adopted self-service way.
    • It is suitable all kinds of parking lot unmanned, users can charge, etc. independently.
  • Main Function

    • Supporting RFID to charge.
    • Screen Display
    • Shows information such as charging status ,max and charging current , power, and Kwh.
  • WARNING
    It may cause danger and harm, or damage the device if you don’t operate in accordance with safety guide.

  • Electrical and fire risk:
    Don’t use damaged and smudgy charge connector.
    The electrical system for the connection of the EV charger must be inspected by professional. Meet the current requirements of the station. Don’t follow the safety instructions can result in danger and injury, as well as damage to the equipment. Check the charging station and connector and see if there are any visible damage before each use.
    EV chargers can only be used to charge electric vehicles (EVs) or hybrid vehicles (PHEVs)
    Do not install the charging station in a closed container to avoid overheating.

Product View

Appearance

ZheJiang-Guangwei-Electric-Tools-Co-Ltd-EAD02-EV-Charging-Wallbox-AC-
Charger-1

Product Specification

EV Home Charging Wallbox

Product| Model No.| EAD02·03 EAP02-03| EAD02-07 EAP02-07| EAD02-09 EAP02-09| EAD02-11 EAP02-ll
Input| Power Supply| NEMA Plug Or Hardwired| NEMA Plug Or Hardwired| NEMA Plug Or Hardwired| Hardwired
RatedVoltage| 208V/240V AC
RatedCurrent| 16A| 32A| 40A| 48A
PowerFrequency| 50Hz/60Hz
Output| OutputVoltage| 208V/240V AC
f-.A:Jx Current| 16A| 32A| 40A| 48A
Rated Power| 3.7kW| 7kW| 9kW| llkW
User Interface| Charging connector| Type 1(SAE J 1772)
Cable Length| 25ft
CableSpecification| 14AWG3+18AWGl| 10AWG3+18AWGl| 9AWG3+18AWGl| 8AWG’2+ lOAWG’l+ 16AWG’l
Enclosuref-.A:Jterial| Plastic PC
Display| Charging Data
Start fvlode| RFID card
Safety| ApplicationStandard| UL2594
Certification| ETL, FCC
Ingress Protection| Type 4/IP65 for box
RCD| CCID 20mA
Electrical protection| Over Current Pro tection, Over/Under Vo| toge
Protection, Over Temperature Prote ction, Surge Protection, Leakage Protection, GroundProtection
Environment| Installation| Wa| fvlounted / Po| e fvlounted
Working Temperature| -22°F to 1 2 2°F
WorkingHumanity| 5%~95%

Product list

  • Charging device assembly 1
  • Wall-mount Bracket 1
  • Installation fits (bag) 1
  • RFID cards 3
  • Instruction Manual 1

Transportation and Storage
The product is packed well before leave factory.
Avoid sharp pounding, jolt and damage the package when transport. The storage and transportation temperature is -40°C+70°C, the humidity is 95%, the ambient air shouldn’t contain acidity, alkalinity and other corrosive gas or explosive gas.

Instruction Instruction

  • Safety Tip
    The people who assemble and use the EV charger must response the follow principle and rule.to confirm the relevant people and device operation normally: Before device power on. please confirm the device is good earth, to avoid the unnecessary accident.
    All of the tools must be insulation treatment to avoid the sort circuit or personal injury due to uncovered metal touches metal frame. Confirm the EV charger using life and operation steadily, the device should keep cleaning, constant temperature and constant humidity. the EV charger can’t be used in the environment that contain volatile gas or flammable-explosive. Children mustn’t touch EV

  • Installation Guide

Pole mounted installation:
This device shall be mounted at a sufficient height from grade such that the height of the storage means for the coupling device is located between 600 mm (24 inches) and 1 .2 m (4 feet) from grade.

ZheJiang-Guangwei-Electric-Tools-Co-Ltd-EAD02-EV-Charging-Wallbox-AC-
Charger-2

Wall mounted installation

ZheJiang-Guangwei-Electric-Tools-Co-Ltd-EAD02-EV-Charging-Wallbox-AC-
Charger-3

Danger!
Laypeople1 s installation may cause the danger.
Only electrician who is trained and qualified can install the EV charger.
The electric shock would happen if don’t install accord with operation procedure. The electric shock or the serious hazard would happen if don’t observe operation instruction of safety precaution.

Electrical connection
Before use

PLEASE NOTE: This procedure may only be carried out by an authorised electrician!

Electrical connection
The protection of the charging system must be carried out in accordance with the relevant notional regulations. It depends on, for example, the switch-off time required, the internal network resistance, conductor cross section, cable length and the max. capacity of the charging system. The individual phases of the supply voltage must each be fused with circuit breakers.

CAUTION: Please be sure that there is no voltage in the power lines which are to be connected to the EV charger

ZheJiang-Guangwei-Electric-Tools-Co-Ltd-EAD02-EV-Charging-Wallbox-AC-
Charger- \(2\)

Charging Instruction

  • Charge preparation
    After plug in, according to the screen prompt operation, start to charge.

  • Start to charge (RFID)
    ZheJiang-Guangwei-Electric-Tools-Co-Ltd-EAD02-EV-Charging-Wallbox-AC-
Charger- \(3\)
    ZheJiang-Guangwei-Electric-Tools-Co-Ltd-EAD02-EV-Charging-Wallbox-AC-
Charger- \(1\)

Malfunction and Maintenance

  • Maintenance caution
    Check whether the line is aging with the monthly power cut. Conduct leakage test on the external leakage protector to ensure the normal operation of the leakage protector. Observe incoming lines to make sure no wire is damaged.

  • Breakdown and Maintenance

Error Mode

| Error State| Recovery Method
---|---|---
ERROR 2|   Over Temperature (Control Box)|   Wait for temperature reduction, retry charging .
ERROR 3|   Over Current|   Disconnect the charging plug. Retr y charging .
ERROR 5|   Leakage(RCD)|  Disconnect the charging plug,make sure the Land N cable is not short to PE cable . Retry charging .
ERROR 6|   Leakage Device Self-test|   Disconnect the charging plug,retrych arging. Can not use any more.

ERROR 7

|   Low Voltage|   Make sure the input volta ge is between 120V to 240V. Retry charging .
| Error State| Recovery Method
---|---|---
ERROR 8| Over Voltage| Make sure the input voltage is between 120V to 240V. Retry charging.
ERROR 9| Relay Conglutination| Disconnect the charging plug. Retry charging.
ERROR 10| Relay Stuck Fault| Disconnect the charging plug. Retry charging.
ERROR 12| Over Temperature (Input Plug)| Wait for temperature reduction, retry charging.
ERROR 13| Grounding(PE) Test failed| Make sure the PE cable is connected to Ground, retry cha rging .
ERROR 14| CP voltage is fault| Disconnect the charging plug, retry charging .
ERROR 15| CP diode is fault| Disconnect the charging plug, retry chargingand make sure the car is OK.
| Error State| Recovery Method
---|---|---
ERROR 22| Sampling circuit fault| Disconnect the charging plug. Retry charging.
ERROR 24| Temperature cable broke| Disconnect the charging plug, retry charging.
ERROR 26| Sampling reference voltage is fault| Disconnect the charging plug. Retry charging.