PHOENIX FOCUS II Dual Axial Air Mover Owner’s Manual

June 21, 2024
Phoenix

PHOENIX FOCUS II Dual Axial Air Mover

Product Information

Specifications:

  • Part Numbers: 4042250-01 (Red), 4042250-02
    (Blue), 4042250-03 (Green)

  • Power: 110-120 VAC, 1.1 Amps

  • Blower: 1,015 CFM

  • Cord Length: 17ft 6in

  • Warranty: One Year, 100% Parts and Labor

  • Dimensions:

    • Width: 21 inches
    • Height: 9 3/8 inches
    • Depth: 8 1/4 inches
  • Weight: 16 lbs.

Important Safety Instructions:

  • Keep a safe distance from obstructions.
  • Indoor use only.
  • Avoid using throw rugs, runners, or similar coverings near the device.
  • Do not route the cord under furniture or appliances.
  • Arrange the cord away from traffic areas and where it will not be tripped over.
  • WARNING: Not suitable for use with Solid-State Speed Controls.
  • AVERTISSEMENT: Ne Convient Pas a Des Régulateurs De Vitesse à Semi-Conducteurs.
  • WARNING: Do not use or store this device in an area accessible to children.
  • AVERTISSEMENT: Ne Pas utiliser ou stocker cet appareil dans une zone accessible aux enfants.

Operation:

  • Transporting the Phoenix Focus II:
    The Phoenix Focus II is designed to be stacked vertically or horizontally (Bookshelf Stacking) for transport. The deeply-molded interlocking features make it rock solid when stacked for transport.

  • Positioning and Directing Airflow:
    The Phoenix Focus II is stable on all five sides, allowing maximum flexibility to position and direct the drying. Optional Focus Control Sticks provide unprecedented control and flexibility in directing airflow.

  • Power Usage and Efficiency:
    The Phoenix Focus II delivers airflow of over 1000 CFM while consuming only 1.1 Amps, setting the industry standard for drying per amp. This efficient design allows for four times the number of full-size axial air movers while maximizing storage space during transportation.

Frequently Asked Questions (FAQ):

  • Q: Can the Phoenix Focus II be used outdoors?
    A: No, the Phoenix Focus II is designed for indoor use only.

  • Q: What is the warranty on the Phoenix Focus II?
    A: The Phoenix Focus II comes with a one-year warranty covering 100% parts and labor.

Models

Phoenix Focus II

  • PN 4042250-01 (Red)
  • 4042250-02 (Blue)
  • 4042250-03 (Green)

Introduction

  • The Phoenix FOCUS II is the new leader in performance, convenience, portability, and safety for low profile air
  • Its ultra-compact (21” X 8 1/4” footprint and 9 3/8” height) makes the Phoenix Focus II the most compact and portable fan in its class. The rugged molded-in handles give you the solid control required when packing and unpacking air-deeply-molded interlocking features, the Phoenix Focus II is rock solid when stacked for transport.
  • With its Patent Pending design, and optimized outlet shape, the Phoenix Focus II delivers airflow of over 1000 CFM. This gives you high-velocity air over a 50% larger area than other stable on all five sides for maximum flexibility to position and direct the drying. Optional Focus Control Sticks allow unprecedented control with amazing flexibility.
  • The (patent pending), compact design of the Phoenix Focus II allows four times the number of full-size axial air movers, maximizing valuable storage space during transportation and resulting in industry-leading deployment on-site.
  • All this performance is available with half the power draw. At 1.1 amps the Phoenix Focus II sets the industry standard for drying per amp.

The Phoenix Focus II

  • 1,015 CFM, 1.1 Amp
  • Four air movers in the space of one
  • Daisy chain up to 10 fans on a single 15 Amp circuit
  • Dual stacking and cord wrap options
  • All stainless steel fasteners

Patent: thermastor.com/patents.

  • Serial No.__
  • Purchase Date_____
  • Dealer’s Name_____

Read the operation and maintenance instructions carefully before using this unit. Proper adherence to these instructions is essential to obtain maximum benefit from your Phoenix Focus II.

Specifications

  • Part No.
    • 4042250-01 (Red)
    • 4042250-02 (Blue)
    • 4042250-03 (Green)
  • Power 110-120 VAC, 1.1 Amps
  • Blower 1,015 CFM
  • Cord Length 17ft 6in
  • Warranty One Year, 100% Parts and Labor
  • Dimensions
    • Width 21”
    • Height 9 3/8”
    • Depth 8 1/4”
    • Weight 16 lbs.

Important Safety Instructions

CAUTION:
Risk of electric shock. Can cause injury or death to reduce the risk of electric shock:

  • Do not be exposed to standing water or rain.
  • Unplug the fan before servicing.
  • Do not block air intake or outlet. One foot minimum distance to obstructions.

Indoor use only

  • Do not use it as a stool or bench.
  • Do not operate with a damaged cord or plug.
  • Do not run the cord under the carpeting. Do not cover the cord with throw rugs, runners, or similar coverings. Do not route the cord under furniture or appliances. Arrange the cord away from the traffic area and where it will not be tripped over.
  • WARNING: Not Suitable for use with Solid-State Speed Controls
  • WARNING: DO NOT use or store this device in an area that is accessible to children.

Operation

  • Transporting the Phoenix Focus II
    The Phoenix Focus II is designed to be stacked vertically or horizontally (“Bookshelf Stacking”) for transport.

  • Electrical Requirements
    The Phoenix Focus II can be plugged directly into any standard wall receptacle. The Phoenix Focus II draws 1.1 amps at 110-120 VAC. Up to 10 Phoenix Focus IIs can be daisy chained on a standard 15 amp branch circuit.

  • Focus Corners
    The Phoenix Focus II is designed with four focus corners to optimize drying over a wide surface area staring directly at the front of the device.

  • Resettable Circuit Breaker

    • The 12 Amp thermal circuit breaker protects the unit and devices connected receptacle. In case of a fault, the breaker can be reset at the Phoenix Focus II control panel.
    • Use of multiple fans and any other connected devices must be under the National Electric Code and any additional codes or laws required by your local government.

IMPORTANT:

  • The total amperage of the Phoenix Focus II plus all devices plugged into its convenience receptacle is limited by the onboard circuit breaker. Excessive current will cause the circuit breaker to trip. This may occur instantly or after a period depending on the operating conditions.
  • When the Phoenix Focus II is plugged into a standard “powered” wall outlet the Phoenix Focus II is electrically “HOT” and AC voltage is present.

Maintenance

WARNING:
Disconnect the unit from power before servicing or cleaning. Replace all safety grills after servicing or cleaning.

Power Cord
Visually inspect the cord and plug head before use. If there are signs of damage or excessive wear, discontinue use until the unit has been serviced.

Cleaning

  • The housing is made of durable and washable polypropylene. When cleaning, the use of solvents is NOT recommended.
  • When washing inside the unit, disconnect the unit from its power source. Protect the switch, receptacle, and circuit breaker from water intrusion. Do not spray water or cleaning solution on the motor. If the motor does get wet, allow the motor to dry completely before restarting. If the fan is to be washed and not used within 24 hours, allow the fan to drip dry for 10 minutes and then run for 5 minutes before storing.

IMPORTANT:
Do NOT remove the impeller blade from the motor assembly. Doing so can cause the blade to become imbalanced upon re-assembly.

Service

CAUTION:
Servicing the Phoenix Focus II with its high voltage circuitry presents a health hazard that could result in death, serious bodily injury, and/or property damage. Disconnect the appliance from the power supply before servicing. Only qualified service people should service this unit.

CAUTION:
If the supply cord or circuit breaker becomes damaged, it must be replaced by the manufacturer, its service agent, or a similarly qualified person to avoid a hazard.

Wiring Diagram

Service Parts

Part No./Description

  • 4042304 FOOT, FOCUS II
  • 4042305 GRILL, INTAKE, FOCUS II
  • 4042306 GRILL, EXHAUST, FOCUS II
  • 4042311 FAN, MOTOR, FOCUS II
  • 4042312 CAPACITOR, MFD,500V,DRY,CLASS A
  • 4042313 CORD,14/3,SJT,115V,PLUG&LMP
  • 4042314 CIRCUIT BREAKER, A, SNAP-IN
  • 4042315 SWITCH, ROCKER, SPST, ILLUMINATED
  • 4042316 OUTLET, SNAP-IN,15A,120V
  • 4042321 SCREW, PNCS, M5X12, SS
  • 4042322 SCREW, PHS, M5X20, THREAD FORM, SS
  • 4042323 SCREW, PHCS, M4X12, SS
  • 4042325 SCREW, PHCS, M4X10, SS, W/WASHER

Accessories

8” x 1/2” CPVC pipe (.625 OD) can be purchased from any hardware store and can be used to allow for additional drying positions.

LIMITED WARRANTY

  • Warrantor:
    Therma-Stor LLC 4201 Lien Rd Madison, WI 53704

  • Telephone: 1-800-533-7533

Who Is Covered:
This warranty extends only to the original end-user of the Focus II Fan, and may not be assigned or transferred.

First-Year Warranty:
Therma-Stor Products warrants that for one (1) year the Focus II Fan will operate free from any defects in materials and workmanship, or Therma-Stor Products will, at its option, repair or replace the defective part(s), free of any charge.

End-User Responsibilities:
Warranty service must be performed by a Servicer authorized by Therma-Stor Products. If the end-user is unable to locate or obtain warranty service from an authorized Servicer, he should call Therma-Stor Products at the above number and ask for the Therma-Stor Products Service Department, which will then arrange for covered warranty service. Warranty service will be performed during normal working hours.

The end-user must present proof of purchase (lease) upon request, by use of the warranty card or other reasonable and reliable means. The end-user is responsible for normal care. This warranty does not cover any defect, malfunction, etc. resulting from misuse, abuse, lack of normal care, corrosion, freezing, tampering, modification, unauthorized or improper repair or installation, accident, acts of nature, or any other cause beyond Therma- Stor Products’ reasonable control.
Limitations and Exclusions: If any Focus II Fan part is repaired or replaced, the new part shall be warranted for only the remainder of the original warranty period applicable thereto (but all warranty periods will be extended by the period, if any, that the Focus II Fan is out of service while awaiting covered warranty service).

UPON THE EXPIRATION OF THE WRITTEN WARRANTY APPLICABLE TO THE Focus II Fan OR ANY PART THEREOF, ALL OTHER WARRANTIES IMPLIED BY LAW, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL ALSO EXPIRE. ALL WARRANTIES MADE BY THERMA-STOR PRODUCTS ARE SET FORTH HEREIN, AND NO CLAIM MAY BE MADE AGAINST THERMA-STOR PRODUCTS BASED ON ANY ORAL WARRANTY. IN NO EVENT SHALL THERMA-STOR PRODUCTS, IN CONNECTION WITH THE SALE, INSTALLATION, USE, REPAIR OR REPLACEMENT OF ANY Focus II Fan OR PART THEREOF BE LIABLE UNDER ANY LEGAL THEORY FOR ANY SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION WATER DAMAGE (THE END-USER SHOULD TAKE PRECAUTIONS AGAINST SAME), LOST PROFITS, DELAY, OR LOSS OF USE OR DAMAGE TO ANY REAL OR PERSONAL PROPERTY.

Some states do not allow limitations on how long an implied warranty lasts, and some do not allow the exclusion or limitation of incidental or consequential damages, so one or both of these limitations may not apply to you.

Legal Rights:
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

USEPHOENIX.COM | 800-533-7533.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Phoenix User Manuals

Related Manuals