INTENDED USE

The digital thermometer model No. BT-A31 is intended for the measurement and monitoring of the human body temperature by doctor or consumers in the hospital or at home.

CONTENTS

  • Thermometer
  • User Manual

WHY BT-A31?

  • Upon setting up, data auto syncs to the free app Premom.
  • A large and backlit LCD display helps you read results easily.
  • 1/100th high precision with memory recall of last 30 readings.

SET UP AND USE

  • Refer the quick guide of Premom App to set up the App before BBT measurement.
  • Take your temperature

easy-Home-BT-A31-Smart-Basal-Thermometer-User-Manual-fig-
\(1\)

Instruction

Step1: Keep the smart thermometer near your bed. Make sure to take your basal body temperature each morning at the same time for the best results.

easy-Home-BT-A31-Smart-Basal-Thermometer-User-Manual-fig-
\(2\)

Step 2: Upon waking, turn on the smart thermometer. Place the probe under your tongue, close your lips and hold the thermometer there for 90 to 120 seconds. Once you hear 2 short beeps, the temperature taking is completed. Make sure your lips have been closed for at least five minutes without eating, speaking or getting up before taking your temperature.

DATA STORAGE
Memory stores up to 30 measurements on the device. While the thermometer is off double-click the On/Off button to review the stored data. You can exit the memory display mode by holding down the On/Off button for 3 seconds or it will shut off automatically after 30 seconds. CHANGE THE BATTERY
Please replace the battery when the low-battery symbol appears on the right of the LCD display. Remove the battery cover and replace it with a battery of the same battery type CR2032H. Make sure the ‘*” sign faces up. Always dispose of used batteries according to local laws and regulations.

TROUBLESHOOTING

  • Symptoms: Unstable body temperature readings Possible Solutions: Ensure the thermometer probe is placed firmly underneath your tongue, close your lips, breathe normally and do not speak, eat, or drink.
  • Symptoms: Abnormal high BBT Possible Solutions: Take measurement immediately after waking up, limit physical activities before and during measurement.

Note:

  1. If the problem persists, please contact customer support or consult your doctor if concerned.
  2. If you have any problems with this device, such as setting up, maintaining or using, please contact with Easy@Home customer service. Don’t open or repair the device by yourself.

TECHNICAL SPECIFICATIONS

  • Product name …. Electronic Clinical Thermometer
  • Model ………………………..  BT-A31
  • Size …………………… 13.2cm x 2.92cm x 1.39cm
  • Transmission distance …………………………………… 9m
  • Display range…………………………32.00°C – 42.99°C
  • Accuracy …………………………. #0.1°C(from 35.0°C to 39.0°C)
    • +0.2°C(from 32.0°C to 35.0°C, and from 39.0°C to 42.99°C)
  • Battery…………………………….. CR2032H
  • Receiver……………………………Apple Phone: iPhone5+ iOS8.0+
    • Android Phone: Android 4.4+
  • Battery life…………………………………….about 3 months
  • Operating conditions………………………………. Temperature: 5°C to 40°C
  • Weight………………………………………………………..About 20g (without battery)

MAINTENANCE & CLEANING

  1. Clean the tip of the thermometer with a solution of 75% rubbing alcohol and 25% water before and after every use.
  2. Do not use cleaning agents other than alcohol or water to clean the thermometer as it may damage or decrease the lifetime of the product and / or present safety risks.
  3. While you can clean the sensor tip of the thermometer with water, it’s important to avoid fully submerging the device in water or any other liquid. Doing so can result in damage to the thermometer, potentially leading to inaccurate readings and posing a safety risk.

WARRANTY

  1. This product is warranted from manufacturing defects for one year from the date of retail purchase. It does not cover damages or wear resulting from an accident, misuse, abuse, commercial use, or an unauthorized adjustment or repair of the product.
  2. Please direct all returns to the place of original receipt, and you may be asked to provide proof of purchase. To find the customer service menu, please visit our official website at www.premom.com.

WORKING & STORAGE CONDITIONS

  1. Working environment temperature: 5°C ~ 40°C
  2. Working humidity: 15% ~ 85%
  3. Working atmosphere pressure: 86kPa ~ 106kPa
  4. Storage environment temperature: -20°C~55°C
  5. Storage humidity: ≤85%
  6. Storage atmosphere pressure: 86kPa ~ 106kPa

PRECAUTIONS

  1. Do not bite, bend, drop or take apart the thermometer.
  2. Keep the device out of the reach of children/pets to avoid inhalation or swallowing of small parts.
  3. Do not expose it to direct sunlight, high temperature and moisture.
  4. Not intended to be sterilized. Prevent saliva or cleaning solution from penetrating the display window.
  5. Clean the thermometer after or before use with a soft cloth and the cleaning solution listed below and store in the plastic case. Recommend to wipe with wet water-soaked cloth for home use.
  6. If LCD shows the symbol or LCD shows unclear, it means the battery has run out. Please replace the battery within 10 minutes.

EMC/FCC INFORMATION

  1. This product needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided, and this unit can be affected by portable and mobile RF communications equipment.
  2. Do not use a mobile phone or other devices that emit electromagnetic fields, near the unit. This may result in incorrect operation of the unit.
  3. Caution: This unit has been thoroughly tested and inspected to ensure proper performance and operation!
  4. Caution : This machine should not be used adjacent to or stacked with other equipment and if adjacent or stacked use is necessary, this machine should be observed to verify normal operation in the configuration in which it will be used

FCC ID: 2ADNQBTA41CNBT
This device complies with Part 15 of the FCC Rules.

Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation.

WARNINGS

  1. No servicing/maintenance while the thermometer is in use.
  2. Not for use in an OXYGEN RICH ENVIRONMENT.
  3. Before every use, check the device. Do not use the device or an electrode if it is damaged in any way. The continuous use of a damaged unit may cause injury, improper results, or serious danger.
  4. Don’t open or repair the device by yourself.
  5. The housing materials of the thermometer are ABS and TPE. Be careful of potential allergic reactions to these materials.
  6. The typical service life of the new and unused batteries is 100 hours for continuous operation.
  7. Protection against electric shock: Internally powered ME equipment.
  8. Protection against harmful ingress of water or particulate matter: IP22. However, for the sake of accuracy and safety. please refrain from fully immersing the device in water or any other liquid.
  9. Keep new and used batteries out of the reach of children, to seek immediate medical attention if a battery is ingested, and to follow any other consensus medical advice.
  10. Choking Hazard-Small parts not for children under 3 years or any individuals who have a tendency to place inedible object in their mouths.

DISPOSAL OF THE DEVICE
Once the product life has ended or his components do not work anymore their disposal should be carried out according to the current regulations.

EXPLANATION OF SYMBOLS

www.premom.com
Questions or comments?
E-mail: support@premom.com
Distributed by: Easy Healthcare Corporation
360 Shore Dr., Burr Ridge, IL USA 60527
Made in China

easy-Home-BT-A31-Smart-Basal-Thermometer-User-Manual-fig-
\(6\)

Check BT-A31 User Manual in more languages

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

EASY HOME User Manuals

Related Manuals