Specifications

Technical Specifications:

Wall mount Single Door XL150: 330lbs [150kg]

Wall mount Single Door XL80: 176lbs [80kg]

Double Door XL150: 330lbs [150kg]

Double Door XL80: 2 x 176lbs [2 x 80kg]

Tempered Laminate Glass (TLG) and Adhesive Specifications:

  • 3MTM Scotch-WeldTM Urethane Adhesive, DP 605 NS

  • 3MTM Scotch-WeldTM EPXTM Plus II Applicator with 1:1
    Plunger

  • 3MTM Scotch-WeldTM EPXTM Plus II Mixing Square Nozzle,
    5.3mm

  • MUTO TLG gasket set

Product Usage Instructions

Installation Instructions

Overall:

Follow the step-by-step instructions provided in the manual for
installing the MUTO PREMIUM sliding door system XL150/80.

Securing Track to Mounting Surface:

Ensure the track is securely mounted to the surface using
appropriate hardware as per the instructions.

FAQ

Q: What weight can the XL150 and XL80 models support?

A: The XL150 model supports up to 330lbs (150kg) for single
doors, and the XL80 model supports up to 176lbs (80kg) for single
doors.

Q: What adhesive is recommended for the tempered laminate

glass?

A: The recommended adhesive is 3MTM Scotch-WeldTM Urethane
Adhesive, DP 605 NS.

“`

MUTO Premium XL150/80
Wall mount with Dormotion (Glass door)
Installation Manual
936004 – 11/2023 Original document
EN

dormakaba MUTO XL150/80 Wall Mount with Dormotion Installation Instructions
Table of contents

Table of Contents

1 Technical specifications

3

1.1 Overview

3

1.1.1 General information

3

1.1.2 Intended use

3

1.1.3 Glass requirements and fittings

3

1.1.4 Requirements for glass panel

3

1.1.5 Safety instructions

3

1.1.6 Symbols used – Safety/Installation

3

1.1.7 Maintenance, care, repair

3

1.1.8 Disposal

3

1.2 Specifications – technical data

4

1.3 Tempered laminate glass (TLG) and

adhesive specifications

4

2 Installation instructions

5

2.1 Overall

5

2.2 Securing track to mounting surface

6

2.3 Door/wall dimensions

7

2.4A Installing roller carriers:

on monolithic glass ONLY

8

2.4B Installing roller carrier:

on tempered laminate glass ONLY

9

2.5 Install DORMOTION start/stop

10

2.6 Disengaging the anti-jump

10

2.7 Installing the end stops

11

2.8 Install glass/rollers in track

11

2.9 Install floor guide

12

2.10 Install floor guide: continued

12

2.11 Engaging anti-jump

13

2.12 Adjustment door height

13

2.13 Adjustment end stop location:

LEADING end stop

Adjustment end stop location:

TRAILING end stop

14

2.14 Install DORMOTION units

15

2.15 Adjust start/stop pin height (if necessary) 17

2.16 Cover clips

18

2.17 Install brush profile

18

2.18 Install view protection clips

19

2.19 Install cover and view protection profile

20

2.20 Install end caps

20

2

MUTO Premium

936004

11-2023

dormakaba MUTO XL150/80 Wall Mount with Dormotion Installation Instructions
1 Technical specifications

Technical specifications

1.1 Overview
These instructions are for installation of MUTO PREMIUM sliding door system XL150/80 for the following mounting and style versions:
1. Wall mount
1.1.1 General information · dormakaba requires use of tempered monolithic or
tempered laminated glass. · dormakaba glass hardware is not suitable for
application in rooms where chemicals (e.g. chlorine) are used as indoor swimming pools, saunas or salt-water pools. · Never move sliding panels faster than walking speed and always stop the door manually before it reaches end position. · Do not slide doors with excessive force. Install limiting stop to prevent door from opening too far.
1.1.2 Intended use · For sliding door in dry indoor areas only · For manual slowly opening and closing only
1.1.3 Glass requirements and fittings · The substructure/wall must be able to bear
permanent loads and be level (max. tolerance: 1/16″ [2] per 39″ [1m]). · Fasteners must be sufficiently dimensioned for the substructure/wall and weight of the door. · When adjusting glass components, always stick to the required clearance for the respective hardware. Adjust clearance so glass does not come in contact with any hard surfaces such as glass, metal or concrete. · Do not use excessive force when installing the glass (avoid over tightening screws).
1.1.4 Requirements for glass panel · dormakaba requires use of fully tempered glass,
which complies with ASTM C 1036 and ASTM C 1048. Secondary heat soaking processes are recommended but not required. This applies to both tempered monolithic and tempered laminated glass. · Clamping area must be flat and uncoated (no self-cleaning coating!) · Never use glass with conchoidal fractures and/or damaged edges.

· Only properly qualified and specially trained staff are authorized to mount dormakaba glass hardware.
· Due to crushing hazards and possible injury caused by breakage of glass during mounting, corresponding protective clothing (especially gloves and protective goggles) is required.
· Never clamp metal fitting hardware directly to glass surface.

1.1.6

Symbols used – Safety/Installation CAUTION

Mounting components must meet the requirements of substructure/wall and door weight. Please read the technical information for fittings.

WARNING
Risk of breaking glass. When installing the door, support the door panel with a block of wood or similar object.

TIPS AND RECOMMENDATIONS Information note

CLOSING EDGE

1.1.7 Maintenance, care, repair · Immediately replace damaged parts. · Always use original dormakaba parts. · Clean clamping area with alcohol-based standard
commercial cleaning agent before mounting the glass hardware. · Use a damp clothe for occasional cleaning, especially the track. · Always use silicone – and oil-free cleaners (e.g. acetone). · Check glass hardware at regular intervals for proper positioning and smooth operation and correct adjustment. · High traffic door systems require inspection by properly qualified staff (specialized companies or installation firms.)

1.1.5 Safety instructions · Installation requires two people.

1.1.8 Disposal Disposal in accordance with local, state and national regulations.

MUTO Premium

936004

11-2023

3

dormakaba MUTO XL150/80 Wall Mount with Dormotion Installation Instructions

1.2 Specifications – technical data

Wall mount

Single Door

XL150

Door leaf weight lbs [kg] *

330lbs [150]

  • Including weight of auxiliary hardware.

XL80
176lbs [80]

Double Door

XL150

XL80

330lbs [150]

2 x 176lbs [2 x 80]

Technical specifications

1.3 Tempered laminate glass (TLG) and adhesive specifications

Required parts for laminate glass with MUTO System (not included)
3MTM Scotch-WeldTM Urethane Adhesive, DP 605 NS
3MTM Scotch-WeldTM EPXTM Plus II Applicator with 1:1 Plunger 2
3MTM Scotch-WeldTM EPXTM Plus II Mixing Square Nozzle, 5.3mm 3
MUTO TLG gasket set
Handling time frame

Part Number

Quantity

Usage recommendation

934.800

1 tube

1 tube per 4 roller carriers

934.801

1 applicator

1:1 plunger with 934.800 adhesive

934.805

Pk of 4

4 nozzles per 1 tube of adhesive

807.640

1 set

Function

Time

Working life (time between

5 minutes @ 75°F

application and clamping of carrier)

Handling strength

20 minutes @ 73°F or more

Full cure time (normal door usage 48 hours @ 73°F or more not recommended until full cure time as been met)

NOTE: Door glass should not be installed until the full cure time as been reached (see chart above).

Important safety-related information for the mounting and use of dormakaba glass hardware.

1.3.1

Clean clamping area with alcohol-based standard commercial cleaning agent before mounting the glass hardware.

1.3.2 1.3.3

Never clamp metal glass fitting hardware directly to glass surface. Never use clamping product on surfaces with self-cleaning coatings.

2 Scotch-WeldTM EPXTM Plus II Applicator with 1:1 Plunger is a trademark of 3M. 3 Scotch-WeldTM EPXTM Plus II Mixing Square Nozzle is a trademark of 3M.

4

MUTO Premium

936004

11-2023

dormakaba MUTO XL150/80 Wall Mount with Dormotion Installation Instructions
2 Installation instructions
2.1 Overall
Fig. 1

MUTO Premium

1.1 1.2 1.3

936004

1.4
1.1 Cover panel 1.2 Brush strip

1.6

1.8 1.7 1.9

1.10

1.8

1.10

1.6

1.5 1.4

1.3 Track 1.4 End cap

1.5 End stop (x2) 1.6 Cover clips

1.7 Start/stop guide 1.8 Roller carrier

1.9 Floor guide 1.10 Dormotion
units

11-2023

Overall

5

dormakaba MUTO XL150/80 Wall Mount with Dormotion Installation Instructions
2.2 Securing track to mounting surface

Track

NOTE: IF MOUNTING TO GLASS, REFER TO THE SEPARATE SUPPLEMENTAL GLASS MOUNT INSTALLATION INSTRUCTIONS.

THEN BEGIN AT STEP 2.4A IN THIS BOOKLET.

2.2.1 Ensure the track is properly level and secure it to the wall per the appropriate measurements on the following page.
· NOTE: SEE DIMENSION INSTRUCTIONS ON NEXT PAGE FOR REFERENCE.

2.2.2 Use appropriate fasteners according to the following recommendations.

NOTE: WALL REINFORCEMENT: The wall reinforcement must be a minimum of ¼” [6] x 3″ [76] steel angle, 16 gauge metal stud, or 1-1/2″ [38] thick wood blocking secured to the wall studs on a maximum 16″ [406] centers for the length of the track. The wall reinforcement may be flush on the wall surface or on the interior of the wall. For masonry walls the track may be secured directly to the wall with lead anchors.

Track mounting screws must fully penetrate the steel angle, metal stud, or wood blocking, utilizing the predrilled holes in the MUTO track.
Consult with a structural engineer to determine if reinforcement is adequate for your specific application or to meet specific codes in your location.

6

MUTO Premium

936004

11-2023

dormakaba MUTO XL150/80 Wall Mount with Dormotion Installation Instructions
2.3 Door/wall dimensions
Single door mount

clear opening
height (CH)
(DW) Glass door panel

Glass door

1-3/16″ [30]

1-3/16″ [30] clear opening width (CW)

Technical specifications

Top of track to center of mounting hole in track

15/16″ [24]

Bottom of 3/8″ glass to floor [10]

Double door mount

clear opening height (CH)
(DW) Glass door panel

(DW2)
Glass door panel

Top of track to center of mounting hole in track
Glass door

15/16″ [24]

1-3/16″ [30] clear opening width (CW)

1/4″ [6]

1-3/16″ [30]

Bottom of 3/8″ glass to floor [10]

MUTO Premium

936004

11-2023

7

dormakaba MUTO XL150/80 Wall Mount with Dormotion Installation Instructions
2.4A Installing roller carriers: on monolithic glass ONLY
Fig. 2

Roller carriers

DETERMINE THE LEADING (X) VERSUS TRAILING (Z) EDGE OF THE GLASS. “LEADING IS SIDE CLOSEST TO LATCH CLOSED.”
Z X

Secure

Roller location on glass with DORMOTION unit

XL150/80

Single door X

3-1/8″ [80]

Single door Z

1-9/16″ [40]

Double door X

1-9/16″ [40]

Double door Z

2-3/8″ [60]

Glass gasket

Roller carrier

(Front of) Glass (Front of) Glass

Legend Closing edge of door
Torque values XL150/80 10ft lbs
[14Nm] Hex key size XL150/80 4mm

NOTE: FULLY CLEAN SURFACE OF GLASS WITH AN ALCOHOL-BASED MILD GLASS AND SURFACE CLEANER. ENSURE GASKET IS FREE OF DEBRIS. ENSURE ROLLER CARRIER WHEELS ARE FREE OF DEBRIS.

2.4A.1 Slide roller carriers onto glass. 2.4A.2 Slide glass gasket and metal shim between
glass and roller carrier.

·

NOTE: Orient gasket with rubber side facing the

glass.

2.4A.3 Secure roller carriers to glass using appropriate-size hex key at 10 ft lbs [14 Nm].

8

MUTO Premium

936004

11-2023

dormakaba MUTO XL150/80 Wall Mount with Dormotion Installation Instructions
2.4B Installing roller carrier: on tempered laminate glass ONLY
Fig. 3
DETERMINE THE LEADING (X) VERSUS TRAILING (Z) EDGE OF THE GLASS. “LEADING IS SIDE CLOSEST TO LATCH CLOSED.”
Z

Roller carriers X

Secure with vented set screws

Roller location on glass with DORMOTION unit

XL150/80

Single door X

3-1/8″ [80]

Double door X

1-9/16″ [40]

Single door Z

1-9/16″ [40]

Double door Z

2-3/8″ [60]

Roller carrier

3MTM ScotchWeldTM EPXTM Plus
II Applicator

Legend Closing edge of door
Hex key size XL150/80 4mm
Torque values XL150/80 4ft lbs
[5Nm]

Glass gasket

(Front of) Glass (Front of) Glass

Stop when adhesive can be seen past
end of roller carrier

(Back of) Glass

NOTE: THE RECOMMENDED ADHESIVE’S SET-UP TIME IS 20 MINUTES FOR THE DUO-PAK CARTRIDGES. NOTE: USE 1:1 RATIO PLUNGER WITH THE 3MTM Scotch-WeldTM Urethane Adhesive. NOTE: FULLY CLEAN SURFACE OF GLASS WITH AN ALCOHOL-BASED MILD GLASS AND SURFACE CLEANER. ENSURE NO DEBRIS IS ON THE GASKET. ENSURE ROLLER CARRIER WHEELS ARE FREE OF DEBRIS.

2.4B.1 2.4B.2 2.4B.3

Slide carriers onto glass. Replace existing gasket with TLG gasket. Slide laminated glass gasket and metal shim between glass and roller carrier.

NOTE: Orient gasket with rubber side facing the glass.

2.4B.4 Replace existing set screws with vented set screws.
2.4B.5 Tighten vented set screws at 4 ft lbs [5Nm].

NOTE: Onto scrap material, first dispense approximately 12″ of 3MTM Scotch- WeldTM Urethane Adhesive prior to application to prevent mixing errors and ensure optimal hardening.

2.4B.6 Dispense adhesive into vented set screws on both sides of carrier.
Stop application when adhesive can be seen past edge of roller carrier.
DO NOT WIPE any excess adhesive from glass surface. Allow adhesive to dry and scrape off glass surface with a beveled-edge chisel or putty knife.
NOTE: Keep glass flat during curing process.
NOTE: See chart in Specifications section for appropriate curing time.

MUTO Premium

936004

11-2023

9

dormakaba MUTO XL150/80 Wall Mount with Dormotion Installation Instructions
2.5 Install DORMOTION start/stop
Fig. 4

PRODUCT SHIPPED WITH 7/8″ [22] PIN INSTALLED. PIN CAN BE CHANGED TO 1″ [25] IF NECESSARY.

Start/stop pin

Images not to scale

Hex screws

7/8″ [22] =

1″ [25] =

Start/stop Anti-jump

Torque Set screws

3 ft lbs [3 Nm]

Hex key size Set screws 3 mm Hex screws 3 mm

Set screws

Start/stop

Glass gasket

NOTE:
2.5.1 · · · ·

Determine pin length based upon how square and plumb the opening is. If required, change pin in start/stop assembly. Remove hex screws. Remove existing pin and plate. Swap in appropriate pin and plate. Replace hex screws.

2.5.2 2.5.3 2.5.4
NOTE:

Slide start/stop onto glass. Center equally between the carriers. Slide glass gasket between start/stop and glass. Orient with gasket facing glass.

2.5.5 Secure start/stop via set screws.

2.6 Disengaging the anti-jump
Fig. 5

1/4 turn

Antijump

Antijump

NOTE: Anti-jump shipped engaged.
2.6.1 Disengage the anti-jump on roller carrier.

Anti-jump adjustment screw

Hex key size XL150/80 4mm

NOTE: Using the appropriate-size hex key, push antijump adjustment screw IN and turn COUNTERCLOCKWISE 90° to disengage anti-jump.

10

MUTO Premium

936004

11-2023

dormakaba MUTO XL150/80 Wall Mount with Dormotion Installation Instructions

2.7
Fig. 6

Installing the end stops

Set screw

Track

End stops Track

Hex key size XL150/80 3mm

End stops

Bottom section of end stop

2.7.1 Slide end stops into each end of the track.
NOTE: Loosen bottom section of end stop for easier install.

NOTE: FOR XL150 end stops, be sure set screw is flush with back of end stops.
NOTE: Exact location/adjustments will be determined in “Adjustment End Stop Location” step.

2.8 Install glass/rollers in track
Fig. 7

If installing/hanging tempered laminated glass panels, ensure carrier adhesive has cured for 48 hours. See Specifications for more information on cure time.

Setting blocks

ENSURE ROLLERS AND TRACK ARE FREE OF DEBRIS.

2.8.1 Place glass on setting blocks on floor for stability.

2.8.2

Tip glass and rollers upward and rest rollers on track.

MUTO Premium

936004

11-2023

11

dormakaba MUTO XL150/80 Wall Mount with Dormotion Installation Instructions
2.9 Install floor guide
Fig. 8
XL150/80 X 13/16″
[20] Glass X

Glass

Floor guide

Floor guide

Wall

Floor guide anchor
13/1[62″0] 1-7/1[63″6]

2.9.1
2.9.2 2.9.3

REMEMBER ANTI-JUMP IS DISENGAGED!
Align centerline of glass with centerline of floor guide. Be sure the glass is plumb. Mark appropriate floor guide measurements.

2.9.4
2.9.5 2.9.6

TEMPORARILY REMOVE GLASS AND ROLLERS FROM TRACK (TO ALLOW FOR DRILLING SPACE). Pre-drill into mounting surface using a 5/16″ drill bit. Secure floor guide anchor with included fasteners.

2.10 Install floor guide: continued
Fig. 9

Floor guide anchor

Floor guide

Glass

Set screws

2.10.1 2.10.2

SET GLASS AND ROLLERS BACK ONTO TRACK. Slide floor guide over floor guide anchor and tighten with set screws.

2.10.3 Remove setting blocks. NOTE: Be sure glass is centered in floor guide. 2.10.4 Adjust using set screws.

12

MUTO Premium

936004

11-2023

dormakaba MUTO XL150/80 Wall Mount with Dormotion Installation Instructions
2.11 Engaging anti-jump
Fig. 10
1/4 turn

Antijump

Anti-jump Height adjustment

Antijump

Anti-jump adjustment screw

2.11.1 Engage anti-jump on roller carrier.

Hex key size XL150/80 4mm
2.11.2 Using appropriate-size hex key, push anti-jump adjustment screw IN and turn CLOCKWISE 90° to engage anti-jump.

2.12 Adjustment door height
Fig. 11

Glass

Floor guide

+3/16″ [5] -3/16″ [5] =

Door height adjustment tolerance
XL150/80
+3/16″ [+5] -3/16″ [-5]

3/8″ [10]

Height adjustment screw

Height adjustment locking screws

Torque XL150/80

10 ft lbs [14 Nm]

Hex key size XL150/80 4mm

2.12.1 Set height of glass door. 2.12.2 Loosen height adjustment locking screws of
carrier.

2.12.3 Using appropriate-size hex key, turn height adjustment screw CLOCKWISE or COUNTERCLOCKWISE to raise or lower glass.
NOTE: Be sure glass is level during this adjustment.

MUTO Premium

936004

11-2023

13

dormakaba MUTO XL150/80 Wall Mount with Dormotion Installation Instructions

2.13 Adjustment end stop location: LEADING end stop
Fig. 12

0mm

END STOP LOCATION: LEADING EDGE

NOTE: bi-folding: Be sure there is a 1/4″ [6] gap between the right and left hand sets.

End stops
Hex key size XL150/80 3mm

End stop
Bumper

Edge of roller carrier

Glass overlap on wall
max. 1-3/16″ [30] Glass edge
Jamb edge

Door pull

Door closed

Door pull to jamb distance. Verify with local jurisdiction.

Torque XL150/80

3 ft lbs [4 Nm]

Set end stop locations: 2.13.1 Slide end stop
to desired location on track. Bumper should touch edge of roller carrier.
Bumper
Secure

Adjustment end stop location: TRAILING end stop
Fig. 13

0mm

END STOP LOCATION: TRAILING EDGE

NOTE: bi-folding: Be sure there is a 1/4″ [6] gap between the right and left hand sets.

Hex key size XL150/80 3mm

Edge of roller carrier

End stop
Bumper

Door opened

Glass edge

Door pull Jamb edge
Door pull to jamb distance. Verify with local jurisdiction.

Torque XL150/80

3 ft lbs [4 Nm]

Set end stop locations: 2.13.1 Slide end stop
to desired location on track. Bumper should touch edge of roller carrier.
Bumper
Secure

14

MUTO Premium

936004

11-2023

dormakaba MUTO XL150/80 Wall Mount with Dormotion Installation Instructions

2.14 Install DORMOTION units

Fig. 14 Fig. 14.1 RH DM unit

Fastening plate

DM end stop

Hook

Fig. 14.2 RH DM unit fastening plates rotated

Dormotion unit

RH Dormotion -door closed

2.14.1 Rotate RH DM fastening plates.

·

Using 4 mm hex key, loosen

fastening plate hex screws.

·

Rotate fastening plates until they

are parallel to the DM unit (Fig. 14.2)

·

Snug hex screws.

2.14.2 ·

Move door to close position. For installation of RH DM unit, door must be in the closed position against bumper.

Fig. 14.7 RH DM unit aligned in track

Fig. 14.3 RH DM unit inserted in track
DM unit DM trigger block

Door closed
Fig. 14.4 DM unit hook positioned in trigger
DM hook DM end stop

Trigger

Roller carrier Bumper
RH DM unit

Door closed

Fig. 14.5 DM unit end stop and hook separation adjustment

Adjustment tool Fork

Fork gap DM end stop

DM hook Trigger

Bumper RH DM unit

Door closed

Fig. 14.6 RH DM unit fastening plates secured in track

Plates rotated

Fastening plates

SHCS

SHCS

2.14.3 Align DM unit in track, engage DM hook in DM trigger.

·

Align DM unit in track (Fig. 14.7).

·

Slide DM unit over the DM trigger

block until the DM hook engages

the DM trigger (Fig. 14.4)

2.14.4 · · ·

Use adjustment tool to set DM unit final position. Place adjustment tool flat against DM unit with fork between DM hook and DM end stop (Fig. 14.5). Slide DM unit over until hook and DM end stop are against the fork. This sets 5 mm gap (fork gap). Trigger height: Adjust so trigger sets on top of adjustment tool (Para. 2.15).

2.14.5 Secure the DM unit in position.

·

NOTE: Insure door is fully closed

against bumper before performing

this step.

·

Using 4 mm hex key, tighten DM

unit fastening plate socket head

cap screws . Fastening plates must

engage the track (Fig. 14.6 and .8).

Torque Socket head cap screws 3 ft lbs [4 Nm]

Fig. 14.8 RH DM unit installed in track

Plates rotated

MUTO Premium

936004

11-2023

15

dormakaba MUTO XL150/80 Wall Mount with Dormotion Installation Instructions
Fig. 14 (Con’t) Fig. 14.9 LH DM unit
Fastening plate

Hook

DM end stop

Fig. 14.10 LH DM unit fastening plates rotated

Dormotion unit

LH Dormotion -door open 2.14.6 Rotate DM fastening plates.

·

Using 4 mm hex key, loosen

fastening plate hex screws.

·

Rotate fastening plates until they

are parallel to the DM unit (Fig. 14.10)

·

Snug hex screws.

2.14.7 Move door to open position.

·

For installation of LH DM unit, door

must be in the open position

against bumper.

Fig. 14.15 LH DM unit aligned in track

Fig. 14.11 LH DM unit inserted in track

LH DM unit

DM trigger block

Door open

Fig. 14.12 DM unit hook positioned in trigger

Trigger

DM hook DM end stop

Roller carrier Bumper

LH DM unit

Door open

Fig. 14.13 DM unit end stop and hook separation adjustment

Adjustment tool Fork

DM hook Trigger

Fork gap DM end stop

LH DM unit

Bumper

Door open

Fig. 14.14 LH DM unit fastening plates secured in track

Plates rotated

Fastening plates

SHCS

SHCS

2.14.8 Align DM unit in track, engage DM hook in DM trigger.

·

Align DM unit in track (Fig. 14.15).

·

Slide DM unit over the DM trigger

block until the DM hook engages

the DM trigger (Fig. 14.12)

2.14.9 ·
·
·

Set DM unit final position.
Place adjustment tool flat against DM unit with fork between DM hook and DM end stop (Fig. 14.13). Slide DM unit over until hook and DM end stop are against the fork. This sets 5 mm gap (fork gap). Trigger height: Adjust so trigger sets on top of adjustment tool (Para. 2.15).

2.14.10 Secure the DM unit in position.

·

NOTE: Insure door is fully open

against bumper before performing

this step.

·

Using 4 mm hex key, tighten DM

unit fastening plate socket head

cap screws . Fastening plates must

engage the track (Fig. 14.16).

Torque Socket head cap screws 3 ft lbs [4 Nm]

Fig. 14.16 LH DM unit installed in track

Plates rotated

16

MUTO Premium

936004

11-2023

dormakaba MUTO XL150/80 Wall Mount with Dormotion Installation Instructions

2.15 Adjust start/stop pin height (if necessary)
Fig. 15

Hex screw

Hex screw

Start/stops

Start/stop pin

2.15.1
· ·

Adjust HEIGHT of start/stop

pin, if necessary:

Loosen hex screws.

Slide pin and plate up or Hex key size

down.

Hex

3 mm

screws

CORRECT PIN HEIGHT/ ORIENTATION

MUTO Premium

936004

11-2023

17

dormakaba MUTO XL150/80 Wall Mount with Dormotion Installation Instructions
2.16 Cover clips
Fig. 16

Cover clip

Cover clips Brush profile

2.16.1 Insert cover clips into track. (One clip per foot)

2.16.2 Insert perpendicular to track, and turn CLOCKWISE to snap into place.

2.17 Install brush profile
Fig. 17
Cover

Brush

2.17.1 Measure and cut brush to appropriate length.

2.17.2 Slide brush into cover.

18

MUTO Premium

936004

11-2023

dormakaba MUTO XL150/80 Wall Mount with Dormotion Installation Instructions
2.18 Install view protection clips
Fig. 18
TO BE USED WITH ONE OR MULTIPLE SIDELITE APPLICATIONS.

View protection clips Empty sliding portion of track

(Slide door panel) Door panel

Sidelite glass View protection profile
View protection clips

View protection clip

Cover

2.18.1 2.18.2
2.18.3

Slide door open until it meets the end stop. Measure and cut view protection profile to fit into empty sliding portion of track – 3/16″ [5]. Snap view protection clips onto inside of cover as shown.

2.18.4 Use minimum 1 clip per foot of profile.
Exception: If profile is minimum of 1 foot in length, use 2 clips.

MUTO Premium

936004

11-2023

19

dormakaba MUTO XL150/80 Wall Mount with Dormotion Installation Instructions
2.19 Install cover and view protection profile
Fig. 19

View protection profile End caps
Cover clip

View protection profile

Cover

View protection clip

Cover
View protection clip and profile removed for easier viewing of cover installation.

Cover

View protection profile

Cover

2.19.1 Secure cover to clips and snap into place. NOTE: Roll cover from the bottom upwards. Ensure the bottom of the cover is supported by the groove in the cover clip.

2.19.2 Tip view protection profile up into track and snap down into cover and onto track as shown.

2.20 Install end caps
Fig. 20

End cap
2.20.1 Snap end caps onto track.

20

MUTO Premium

936004

End cap
11-2023

dormakaba MUTO XL150/80 Wall Mount with Dormotion Installation Instructions

Blank page

This page left intentionally blank.

MUTO Premium

936004

11-2023

21

Scan for product details and downloads. Call 800-523-8483 or visit glasstechserv.us@dormakaba.com for assistance or warranty information

dormakaba USA, Inc. 1 Dorma Drive, Drawer AC Reamstown, PA 17567

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

dormakaba User Manuals

Related Manuals