saxby lighting RularPRO MW EM Ceiling Tube Light Instruction Manual
- June 13, 2024
- saxby lighting
Table of Contents
- Thank you
- Warning
- Layout
- Installation
- Technical data
- EM data
- Microwave Movement Sensor
- Mechanical structure
- Dimensions
- Wiring Diagram
- Technical Data
- Dial code setting
- Detection Patterns
- Performance
- Care and Safety
- CUSTOMER SUPPORT
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
saxby lighting RularPRO MW EM Ceiling Tube Light
Thank you
Thank you for purchasing this light fitting. Please read the instructions
carefully before use to ensure safe and satisfactory operation of this
product.
Please retain these instructions for future reference.
Warning
This is a Class 1 product and must be earthed.
Please read these instructions carefully before commencing any work.
This unit must be fitted by a competent and qualified electrician.
Check the pack and make sure you have all the parts listed.
Install in accordance with the IEE Wiring regulations and current Building Regulations.
To prevent electrocution switch off at mains supply before installing or maintaining this fitting. Ensure other persons cannot restore the electrical supply without your knowledge. If you are in any doubt, please consult a qualified electrician.
This light fitting should be connected to a fused circuit.
If replacing an existing fitting, make a careful note of the connections.
Waste electrical products should not be disposed of with household waste.
Please recycle where facilities exist. Check with your local authority or
retailer for recycling advice.
Layout
Plan the desired layout of these fittings carefully, ensuring the cables will
reach the distances between the junction box and the each light fitting.
Avoid locating any cables in positions that would cause a hazard. Position
cables and outdoor rated junction boxes (not supplied) away from areas where
they may be at risk from being cut, trapped or damaged.
The mains supply cable must have a minimum cross section area of 1.0mm 2.
Cables must be protected using suitable conduit or plastic trunking.
Take care not to drill into any pipes or mains cables beneath the surface
during mounting holes preparation.
This product can be installed on the ceiling or wall.
Installation
Existing fittings must be completely removed before installation of a new
product. Before removing the existing fitting, carefully note the position of
each set of wires.
Note that the switch is turned off before installation.
The mounting surface must be flat and smooth to ensure a good fit.
The wattage is changeable by using the wattage switch on the driver.
- For the 108870 is the 31.5W / 20W selectable
- For the 108871 is the 39W / 26W selectable
- For the 108872 is the 44W / 35W selectable
The colour is changeable between 3000/4000/6000K using the CCT switch on the
driver before installation.
Choose your preferred wattage and colour before installing by wattage switch
or CCT switch on the driver.
Note: Before you change the wattage or colour, please turn off the power switch for safety.
- Hold the product in place and mark the position of the fixing holes. This may require the help of an assistant. If wall mounting, ensure that the product is level.
- Take care to avoid damaging any concealed wiring and pipes. The correct fixings should be used for bricks, cavity walls or plasterboard.
- Ensure the ceiling or wall is capable of holding the weight of the product and then fix brackets in place.
- Rotate both ends of the product in the direction of the arrow to open the diffuser cover.
- Pull the supply cable through the middle grommet and fix the light fitting into position using appropriate fixings.
- Connect the supply cable to the quick fit terminal block as detailed wiring diagram.
- Close diffuser cover into place.
- Replace fuse or circuit breaker and switch on. Your light is now ready for use.
Technical data
Supply
Voltage:| 220-240 V~, 50 Hz
Bulb| 108870 : 31.5W / 20W LED (SMD) CCT, 3000/4000 /6000K
Type:| 108871 : 39W / 26W LED (SMD) CCT, 3000/4000 /6000K
| 108872 : 44W / 35W LED(SMD) CCT, 3000/4000 /6000K
- Non-replaceable light source
- Replaceable control gear by a professional
- Conformity with all relevant UKCA Directive requirements.
- Conformity with all relevant EC Directive requirements.
- This product is Class 1, must be connected to earth.
- Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or local store for recycling advice.
- This product is not suitable for dimming.
- This product is for indoor use only.
EM data
Duration: 3 hours (180 Minutes) | Battery Specification: LiFePO4 3.2V 1500mAH |
---|---|
Mains input current: 22mA | Battery Charge Time: 24 Hours |
input power in mains operation: 2.5W | Battery charge current: 200mA |
Emergency power: 1W (Battery) | Battery warranty: 5 years |
Operating Temperature: 0ºC-45ºC |
Wiring
This product is Class I product must be earthed.
Having correctly identified the wiring from your existing light fitting and
connect to the connection block inside the product in the following way:
Under the master slave mode, when maintaining the slave lamps, turn off the
supply of both ends of the Master. To avoid the risk of electric shock.
Microwave Movement Sensor
DETACHED SENSOR ON/OFF FUNCTION
-
220-240VAC Input, ON/OFF Function
-
Special Detached Design For More Applications
-
DIP Switch Control, User Friendly
-
5 Years Warranty
-
On/Off Control
-
Detection Area
-
Daylight Sensor
-
Hold Time
-
Warranty
-
Mechanical structure
- Installation Hole
- Input
- Output
- Daylight Sensor
- Microwave Module
- Daylight Threshold
- Hold Time
- Detection Area
Dimensions
Wiring Diagram
Technical Data
Operating Voltage 220-240VAC 50/60Hz| Detection Area 10%/50%/75%/100%|
Programming
DIP
---|---|---
Stand-by Power
≤0.5W| Hold Time
5s/90s/5min/15min| Control
ON/OFF
Microwave Frequency 5.8GHz±75MHz| Mounting Height
Max. 4m/13.12ft Ceiling Mounted| Operating Temperature 25°C~+60°C
Microwave power
<0.3mW| Detection Range Max. ø14m/45.92ft Ceiling Mounted| Motion Detection
0.5~1.5m/s
Connection L.N.N.L’| Daylight Threshold 2Lux/10Lux/50Lux/Disable| IP Rating
IP20
Detection Angle
30-150° Without Glass Cover| Switching capacity
Max. 400W Control Gear; Max. 800W Incandescent lamp| Warranty
5 years
Dial code setting
Detection Patterns
Highest mounting height is 4m
This figure indicates the maximum distance at the highest mounting height with 100% sensitivity.
Performance
Daylight Disable
When daylight threshold is preset as “disable”, the sensor turns light ON when motion gets detected, and OFF after hold time
-
The sensor turns light ON when motion gets detected.
-
The sensor keeps light ON for hold time period after motion leaves.
-
The sensor turns OFF light automatically after the hold time.
Installation precautions
- Microwave sensor can be installed in any lamp except the one with full metal shell.
- The detected surface cannot be shielded by metal objects.
- Make sure the microwave module is completely exposed outside.
- The detection surface of the sensor module shall be installed facing the detection area.
- Should be kept away from the driver to avoid interference generation and lamp flashing.
- Wiring must be strictly in accordance with the wiring diagram to avoid short circuit.
User Notes
- Microwave can penetrate walls or glass thinner than <20mm and attenuate if thicker than <20mm.
- The driver voltage shall be stable and float within 10%.
- Detection area will be affected by speed of motion, mounting height and movement volume.
- Conduct test on sunny days without the lampshade which will affect the tested lux value.
- 3M distance is suggested when having a lot sensors in one same room.
- If the sensor is applicated in the room with 5G WiFi router, 3M distance or above is needed.
Application Environment
- Suitable for indoor installation to avoid false triggering due to external factors such as rain, wind or tree swing.
- Shall not be installed in the place with all four metal shelters and small space (such as galvanized-iron roof).
- Shall note be mounted installation, so as to avoid false trigger caused by the lamp itself shaking.
- Shall not be installed next to large operating machines such as ventilator/ceiling fan to avoid false triggering caused by machine vibration.
- The sensor might be unwanted triggered in rooms that are small, or mostly filled with metal materials; please try to decrease sensitivity when it happens or contact us for support.
Care and Safety
We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive
cleaners as these could damage the finish.
For your safety, always switch off the power supply before cleaning.
CUSTOMER SUPPORT
For further information, please visit https://www.lighting-info.co.uk/108870
V4 24/01/2024
EU Manufacturer : Brilliant AG,
Brilliant Strasse 1, D-27442 Gnarrenburg
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>