PRODUCT

Product Information

Specifications:

  • Brand : Renogy
  • Product Series : Pro Series
  • Battery Type : Smart Lithium Iron Phosphate
  • Voltage : 12.8V
  • Capacity : 100Ah
  • Model Number : RBT12100LFP-BT
  • Version : A0
  • Date : April 30, 2024

Key Features

  • Unparalleled Performance: Greater energy density, deeper discharge capability, higher round-trip efficiency, and faster charging speed in a smaller size.
  • Uncompromising Quality: More than 5000 cycles (80% DOD), continuous charge or discharge current of 100A, wide range of operating temperatures.
  • Reliable Protection Mechanisms: Sturdy internal structure for RV use, over 60 protections and alarms through smart battery management system.
  • Real-time Monitoring: Battery information is accessible through DC Home App.
  • Intelligent Self-Heating Function: Built-in heater for low-temperature charging performance and increased lifespan.

Product Usage Instructions

Before Getting Started:
Read the user manual carefully before operation and save it for future reference. Failure to observe instructions can result in electrical shock, injury, or damage to the battery.

Installation:
Ensure proper installation according to the user manual guidelines to prevent damage or injury. Seek professional help if needed.

Maintenance:
Regularly monitor the battery’s performance and condition. Follow maintenance guidelines provided in the user manual to ensure optimal functionality.

Safety Precautions:

  • Do not attempt repairs by unqualified personnel.
  • Avoid improper installation or operation to prevent damage or injury.
  • Observe all safety recommendations in the user manual.

Charging:
Use compatible chargers and follow the charging instructions provided to maintain battery health and performance.

Discharging:
Adhere to recommended discharge levels and avoid deep discharges to prolong battery lifespan.

Monitoring:
Regularly monitor battery status using the DC Home App for real-time information and performance tracking.

Before Getting Started

The user manual provides important operation and maintenance instructions for Renogy Pro Series 12.8V 100Ah Smart Lithium Iron Phosphate Battery (hereinafter referred to as battery).
Read the user manual carefully before operation and save it for future reference. Failure to observe the instructions or precautions in the user manual can result in electrical shock, serious injury, or death, or can damage the battery, potentially rendering it inoperable.

  • Renogy ensures the accuracy, sufficiency, and the applicability of information in the user manual at the time of printing due to continual product improvements that may occur.
  • Renogy assumes no responsibility or liability for personal and property losses, whether directly and indirectly, caused by the user’s failure to install and use the product in compliance with the user manual.
  • Renogy is not responsible or liable for any failure, damage, or injury resulting from repair attempts by unqualified personnel, improper installation, or inappropriate operation.
  • The illustrations in the user manual are for demonstration purposes only. Details may appear slightly different depending on product revision and market region.
  • Renogy reserves the right to change the information in the user manual without notice. For the latest user manual, visit renogy.com.

Disclaimer

Renogy Pro Series 12.8V 100Ah Smart Lithium Iron Phosphate Battery User Manual © 2024 Renogy. All rights reserved.

  • All information in the user manual is subject to copyright and other intellectual property rights of Renogy and its licensors. The user manual may not be modified, reproduced, or copied, in whole or in part, without the prior written permissions of Renogy and its licensors.
  • The registered trademarks in the user manual are the property of Renogy. The unauthorized use of the trademarks is strictly prohibited.

Symbols Used
The following symbols are used throughout the user manual to highlight important information.

  • WARNING : Indicates a potentially hazardous condition that could result in personal injury or death.
  • CAUTION : Indicates a critical procedure for safe and proper installation and operation.
  • NOTE : Indicates an important step or tip for optimal performance.

Introduction

The Renogy Pro Series 12.8V 100Ah Smart Lithium Iron Phosphate Battery adopts a proprietary battery housing material in a smaller size for your RV application.
Weighing only half of the lead-acid counterparts, the battery can be safely discharged to 100% Depth of Discharge (DOD), delivering twice the energy. Manufactured with automotive grade battery cells, the battery features the highest safety standards and an extended 5000+ cycle life. In addition, the smart Battery Management System (BMS) provides comprehensive protection to the battery.

Key Features

  • Unparalleled Performance
    Features a greater energy density, a deeper discharge capability, a higher round-trip efficiency, and a faster charging speed in a smaller size over counterparts in the market.

  • Uncompromising Quality
    Ensures an exceptional lifespan with more than 5000 cycles (80% DOD), a continuous charge or discharge current of 100A, and a wide range of operating temperatures with the automotive grade battery cells.

  • Reliable Protection Mechanisms
    Designed with a sturdy internal structure for RV use, and includes more than 60 protections and alarms through the smart battery management system.

  • Real-time Monitoring Through DC Home App
    You can easily get the battery information through the DC Home App at any time.

  • Intelligent Self-Heating Function & More Stable Performance
    The built-in heater operates automatically at low temperatures to keep the battery charging, assuring charging performance at low temperature and increasing battery lifespan.

  • Active Safety Protection with Self-Control Fuse
    Different from ordinary passive fuses, the self-control fuse can effectively prevent battery overcurrent and overvoltage failures.

  • Best-in-Class Capacity and Easy Expansion
    The battery provides a maximum capacity of more than 105Ah for a longer- lasting application. It supports up to 8 batteries in parallel, delivering a maximum of 12.8V 800Ah at 10.24kWh.

SKU
Renogy Pro Series 12.8V 100Ah Smart Lithium Iron Phosphate Battery RBT12100LFP-BT

What’s In the Box?

RENOGY-RBT12100LFP-BT Pro-Series-Smart-Lithium-Iron-Phosphate-Battery-FIG-
\(1\)

Make sure that all accessories are complete and free of any signs of damage.

Required Tools & Accessories

RENOGY-RBT12100LFP-BT Pro-Series-Smart-Lithium-Iron-Phosphate-Battery-FIG-
\(2\)

  • Prior to installing and configuring the battery, prepare the recommended tools, components, and accessories.
  • For how to size battery adapter cables, refer to “How to Size Battery Adapter Cables?” in this manual.

Get to Know Smart Lithium Iron Phosphate Battery

Top

RENOGY-RBT12100LFP-BT Pro-Series-Smart-Lithium-Iron-Phosphate-Battery-FIG-
\(3\)

Bottom

RENOGY-RBT12100LFP-BT Pro-Series-Smart-Lithium-Iron-Phosphate-Battery-FIG-
\(4\)

Dimensions

RENOGY-RBT12100LFP-BT Pro-Series-Smart-Lithium-Iron-Phosphate-Battery-
FIG-5

Dimension tolerance: ±0.2 in (0.5 mm)

How to Size Battery Adapter Cables?

Use appropriately sized Battery Adapter Cables (sold separately) based on expected load. Refer to the table below for copper cable ampacities with different gauge sizes.

Cable Gauge Size Ampacity Cable Gauge Size Ampacity
14 AWG (2.08 mm²) 35A 2 AWG (33.6 mm²) 190A
12 AWG (3.31 mm²) 40A 1 AWG (42.4 mm²) 220A
10 AWG (5.25 mm²) 55A 1/0 AWG (53.5 mm²) 260A
8 AWG (8.36 mm²) 80A 2/0 AWG (67.4 mm²) 300A
6 AWG (13.3 mm²) 105A 4/0 AWG (107 mm²) 405A
4 AWG (21.1 mm²) 140A  

The above values are from the NEC Table 310.17 for copper cables rated at 194°F (90°C), operating at an ambient temperature of no more than 86°F (30°C). Cables longer than 13 feet (4000 mm) may require thicker gauge wires to prevent excessive voltage drop in undersized wiring.

Secure the Battery (Optional)

Securing the battery prevents damage to the battery from loose cables and bumps.

Recommended Components & Tools

RENOGY-RBT12100LFP-BT Pro-Series-Smart-Lithium-Iron-Phosphate-Battery-FIG-
\(6\)

  • Recommended components marked with “*” are available on renogy.com.
  • Alternative mounting methods are allowed to meet the requirements of specific applications.
  • Choose proper mounting screws specific to your installation site. This manual takes self-tapping screws for wooden walls as an example.
  • Do not install batteries sideways or upside down.
  1. Install the battery fix bracket through the mounting holes on the battery.RENOGY-RBT12100LFP-BT Pro-Series-Smart-Lithium-Iron-Phosphate-Battery-FIG- \(7\)
  2. Mount the battery on a flat surface.RENOGY-RBT12100LFP-BT Pro-Series-Smart-Lithium-Iron-Phosphate-Battery-FIG- \(8\)

Step 1. Plan a Mounting Site

For optimal battery performance, it is recommended to install the battery in a clean, cool, and dry location, free from any accumulation of water, oil, or dirt. Accumulation of such materials on the battery can lead to current leakage, self-discharge, and even short-circuiting.

RENOGY-RBT12100LFP-BT Pro-Series-Smart-Lithium-Iron-Phosphate-Battery-FIG-
\(9\)

  • Sufficient airflow must be provided to prevent excessive heat build-up and to minimize temperature variation between the connected batteries.
  • This user manual takes a battery as an example to illustrate how to install the battery.

Step 2. Wear Insulating Gloves

RENOGY-RBT12100LFP-BT Pro-Series-Smart-Lithium-Iron-Phosphate-Battery-FIG-
\(10\)

Step 3. Check the Battery

Inspect the battery for any visible damage including cracks, dents, deformation, and other visible abnormalities. All connector contacts shall be clean, free of dirt and corrosion, and dry.

  • Do not touch the exposed electrolyte or powder if the battery is damaged.
  • If uncovered electrolyte or powder contacts your skin or eyes, flush it out immediately with plenty of clean water and seek medical attention.

Step 4. Install Battery Terminals

RENOGY-RBT12100LFP-BT Pro-Series-Smart-Lithium-Iron-Phosphate-Battery-FIG-
\(11\)

  • Ensure the cable lug and the top surface of the terminal are in contact, and place the washers on top of the lug. Do not place the washers between the battery terminal and the cable lug to avoid high resistance and excessive heating.
  • Avoid short-circuiting the battery terminals to prevent irreversible damage to the system and battery caused by current bursts.
  • Verify polarity before wiring to avoid irreversible battery damage due to polarity reversal.
  • Do not touch the positive and negative terminals of the battery with your hands.
  • To ensure safe and reliable operation of the system, please follow the torque specifications recommended by the manufacturer when securing cable connections. Over-tightening can result in terminal breakage, while loose connections can lead to terminal meltdown or fire. When securing multiple cable lugs on a single battery terminal, use the included Long Terminal Bolts.

Step 5. Connect the Battery to Other Devices

Please use circuit breakers, fuses, or disconnects appropriately sized by a certified electrician, licensed installers, or regional code authorities to protect all electrical equipment.

For a Single Battery

RENOGY-RBT12100LFP-BT Pro-Series-Smart-Lithium-Iron-Phosphate-Battery-FIG-
\(12\)

For Batteries in Parallel

RENOGY-RBT12100LFP-BT Pro-Series-Smart-Lithium-Iron-Phosphate-Battery-FIG-
\(13\)

How to Connect Renogy Pro Batteries in Parallel?

Calculate Voltage and Current in Parallel Connections

RENOGY-RBT12100LFP-BT Pro-Series-Smart-Lithium-Iron-Phosphate-Battery-FIG-
\(14\)

  • This battery is designed for parallel use only.
  • Long terminal bolts (M8 1.25 16 mm) should be used to secure the battery adapter cables. The recommended torque is 70.8 in·lbs (8 N·m).
  • Do not connect batteries with different chemistries, rated capacities, nominal voltages, brands, or models in parallel or in series. This can result in potential damage to the batteries and the connected devices, and can also pose safety risks.
  • Avoid connecting batteries that have been purchased for more than half a year. Over time, batteries can degrade and their performance may decrease, which can affect their ability to deliver reliable power and may lead to safety hazards.
  • The cables between each connected battery should be of equal length to ensure that all batteries can work equally together.

Balance Batteries Prior to Connection
Before connecting batteries in parallel, it is important to balance them to reduce voltage differences and optimize their performance. Follow these three steps:

  1. Charge each battery individually to its full capacity using a suitable charger.RENOGY-RBT12100LFP-BT Pro-Series-Smart-Lithium-Iron-Phosphate-Battery-FIG- \(15\)
  2. Use a voltmeter to measure the voltage of each battery. It is best to keep the voltage difference of each battery less than 0.1V.RENOGY-RBT12100LFP-BT Pro-Series-Smart-Lithium-Iron-Phosphate-Battery-FIG- \(16\)
  3. Connect all the batteries in parallel and allow them to rest together for 12 to 24 hours.

RENOGY-RBT12100LFP-BT Pro-Series-Smart-Lithium-Iron-Phosphate-Battery-FIG-
\(17\)

It is recommended to periodically rebalance the battery voltages every six months when connecting multiple batteries as a battery system. Slight voltage differences can occur among batteries over time due to factors like battery chemistry, capacity, temperature, and usage patterns.

Parallel Connection — Installation Steps

  • You can choose suitable busbars in parallel connections. Busbars help handle high currents and are typically arranged in a parallel or stacked configuration to distribute electrical power efficiently.
  • Note that the cable connection methods provided below are for reference purposes only, as the optimal approach may vary depending on the specific situation. It is essential to consider various factors, such as the cable size, equipment used, and environmental conditions.

RENOGY-RBT12100LFP-BT Pro-Series-Smart-Lithium-Iron-Phosphate-Battery-FIG-
\(18\)

2P Battery System 12V (12.8V) 200Ah
Energy 2560Wh
8P Battery System 12V (12.8V) 800Ah
Energy 10240Wh

Battery Cell Balancing
The battery employs bypass circuit to maintain the balance between each battery cell group. Each battery cell group is connected with a bypass resistor and a switch in parallel. During the charging process, if the highest-voltage battery cell group reaches the set balancing starting voltage, and the voltage difference between the highest-voltage and the lowest-voltage battery cell group exceeds the set voltage difference, the switch connected to the highest-voltage battery cell group will be closed. This action shunts the charge current around the highest-voltage battery cell group through the bypass resistor until the voltage difference drops below the set value.
To avoid excessive energy loss, the battery cell balancing is only performed during the charging process.

Remote, 24/7 Monitoring via DC Home App

  1. Download the DC Home app. Login to the app with your account.RENOGY-RBT12100LFP-BT Pro-Series-Smart-Lithium-Iron-Phosphate-Battery-FIG- \(19\)
  2. Pair the battery with the DC Home app. Monitor the battery parameters via the app.RENOGY-RBT12100LFP-BT Pro-Series-Smart-Lithium-Iron-Phosphate-Battery-FIG- \(20\)

Charging/Discharging Parameter Settings

Charge

Charge/Boost Voltage 14.4V Boost Return Voltage 13.2V
Bulk/Absorption Voltage 14.4V Overvoltage Disconnect 15.0V
Bulk/Absorption Voltage 14.4V / Disabled Overvoltage Reconnect

14.2V

Discharging

Low Voltage Reconnect 12.6V Undervoltage Warning 12.0V
Undervoltage Shutdown 10.0V  

Battery Charging and Discharging Logic

The battery may be received at a partial state of charge (SOC) depending on the time between manufacturing and shipping. It is crucial to fully charge the battery before its initial use. In case the battery shuts off due to low SOC, promptly disconnect it from loads and charge it to prevent irreversible damage. Follow the instructions in this user manual for proper charging and usage to ensure optimal battery performance and longevity.

Charging Logic
The standard charging process for the battery involves charging at a constant current of 50A until the battery voltage reaches 14.4V, followed by charging at a constant voltage of 14.4V while tapering the charge current. The charging process is considered complete when the charge current is less than 5A (also known as tail current).
The standard charging process typically takes 2.5 hours and requires battery temperatures to be between 32°F and 131°F (0°C and 55°C) for safe charging. Leaving the battery on float will continue to balance the battery cells without damaging the battery.

RENOGY-RBT12100LFP-BT Pro-Series-Smart-Lithium-Iron-Phosphate-Battery-FIG-
\(21\)

  • Lithium batteries are compatible with various charging methods, including MPPT charge controller, AC charger, and DC-DC charger. The crucial parameter setting for these chargers is to set the charge voltage, boost voltage, or bulk voltage at 14.4V (±0.2V).
  • Do not overcharge or overdischarge the battery.
  • Do not discharge the battery at high temperatures above 140°F (60°C).
  • Only charge the battery with a battery charger or charge controller that is compatible with lithium iron phosphate batteries.
  • Do not exceed the maximum continuous charge current (100A) of the battery.

Discharging Logic
During standard discharging, the battery is discharged at a constant current of 50A until the voltage drops to 10V. To ensure safe discharging, the battery temperature should be between -4°F (-20°C) and 131°F (60°C).

  • To ensure safe and optimal battery usage, it is recommended to pair the battery with discharge equipment that features a low voltage disconnect (LVD) function.
  • Do not connect large loads to the battery when it is running low.
  • Do not exceed the maximum continuous discharge current (100A) of the battery.

How to Estimate the Battery SOC?

The SOC values listed below are estimated based on the open circuit voltage when the battery is at rest for 30 minutes, not in charging or discharging state.

SOC Open Circult Voltage SOC Open Circult Voltage
100% 13.6V 30% 12.9V
99% 13.4V 20% 12.8V
90% 13.2V 14% 12.7V
70% 13.1V 9% 12.6V
40% 13.0V 0% 10.0V

The table above is for reference only because slight variations in battery voltage may occur among different batteries.

Self-Heating Function

The normal operation of the self-heating function requires a stable charge current greater than 4A for each battery in the parallel battery bank. The self-heating function will start operating automatically once the battery and the battery temperature drops below 41°F (5°C) and stop operating automatically once the battery temperature rises above 50°F (10°C). The temperature rise rate is approximately 51.8°F (11°C) per hour when running at full power of 55W (4A).

Battery Management System

This smart battery management system has more than 60 fault alarms and protections to fully protect your battery safety. Below we list some common faults and protections for reference.

Battery Operating Status Condition (For Reference Only)

Battery Cell Overvoltage

|

Protection

| Trigger| Battery Cell Voltage ≥ 3.7V
Recover| Battery Cell Voltage ≤ 3.45V

Battery Cell Undervoltage

|

Protection

| Trigger| Battery Cell Voltage ≤ 2.7V (> 0°C) Battery Cell Voltage ≤ 2.2V (≤ 0°C)
Recover| Battery Cell Voltage ≤ 3.1V (> 0°C) Battery Cell Voltage ≤ 3.0V (≤ 0°C)
Cell Undervoltage Permanent Failure| Protection| Trigger| Battery Cell Voltage ≤ 1.8V

Charge High Temperature

|

Protection

| Trigger| Battery Temperature ≥ 131°F (55°C)
Recover| Battery Temperature ≤ 122°F (50°C)

Discharge High Temperature

|

Protection

| Trigger| Battery Temperature ≥ 140°F (60°C)
Recover| Battery Temperature ≤ 122°F (50°C)
Battery Operating Status| Condition (For Reference Only)
---|---

Charge Low Temperature

|

Protection

| Trigger| Battery Temperature ≤ 32°F (0°C)
Recover| Battery Temperature ≥ 37°F (3°C)

Discharge Low Temperature

|

Protection

| Trigger| Battery Temperature ≤ -4°F (-20°C)
Recover| Battery Temperature ≥ 1.4°F (-17°C)

Charge Overcurrent

|

Primary Protection

| Trigger| Charge Current ≥ 115A (15s)

Recover

| Discharge Current ≥ 0.5A

or

Recover automatically after 60s

Secondary Protection

| Trigger| Charge Current ≥ 118A (5s)

Recover

| Discharge Current ≥ 0.5A

or

Recover automatically after 60s

Ultimate protection

| Trigger| Charge Current ≥ 200A (300ms)

Recover

| Discharge Current ≥ 0.5A

or

Recover automatically after 60s Charging is locked when the Ultimate Protection is triggered three times.

Discharge Overcurrent

|

Primary Protection

| Trigger| Discharge Current ≥ 125A (60s)

Recover

| Charge Current ≥ 0.5A

or

Recover automatically after 60s

Secondary Protection

| Trigger| Discharge Current ≥ 200A (30s)

Recover

| Charge Current ≥ 0.5A

or

Recover automatically after 60s

Ultimate protection

| Trigger| Discharge Current ≥ 250A (300ms)

Recover

| Charge Current ≥ 0.5A

or

Recover automatically after 10s Charging is locked when the Ultimate Protection is triggered three times.

Short Circuit

|

Protection

| Trigger| Discharge Current ≥ 500A
Recover| When short circuit is removed.

Troubleshooting

Problem Possible Causes Solution

Ÿ The battery is unable to be activated with a charge/discharge

current greater than 1A

Ÿ The battery is activated at open circuit voltage below 10V

|

Severe battery overdischarge due to self-discharge or parasitic loads

|

Revive the battery with a battery charger or charge controller featuring lithium battery activation or force charging.

The battery shuts off due to undervoltage protection.| The battery voltage drops below the preset threshold| Disconnect the battery from loads, and charge the battery with a current greater than 1A as soon as possible.

The battery cuts off the charging current due to overvoltage protection

|

The battery voltage exceeds the preset threshold during charging.

| 1.  Disconnect the battery from the charging source.

2.  Reduce charge voltage by 0.2V to 0.4V for 6 hours.

3.  Attempt to fully charge the battery again with the correct voltage setting. If the problem persists with a lithium iron phosphate compatible charging source and correct voltage setting, repeat the above steps.

The battery temperature gets too high/low during operation and triggers high/ low temperature protection

|

The battery temperature exceeds the preset threshold.

| 1.  Disconnect the battery from the charging source or loads.

2.  Cool down/Warm up the battery.

3.  The battery recovers from high/low temperature protection automatically and continues operating.

Short circuit protection is triggered.

|

Short circuit occurs in the battery.

| 1.  Remove the short circuit as soon as possible

2.  Charge the battery with a current greater than 1A.

Charge/Discharge over- current protection is triggered due to too high current passing through the battery.| Excessive current flows through the battery during charging or discharging.|

Disconnect the battery from the charging source or loads as soon as possible.

For further assitance, contact Renogy technical support service at https://www.renogy.com/contact-us.

Specifications

General

Battery Cell Type Lithium Iron Phosphate
Rated Capacity (0.5C, 25°C) 100Ah
Nominal Voltage 12.8V
Voltage Range 10V to 14.8V
Cycle Life (0.5C, 25°C) 5000 Cycles (80% DOD)
Dimension 10.6 x 7.6 x 8.1 in / 268 x 193 x 205 mm
Weight 26.9 lbs. / 12.2 kg
Connection Method Parallel (Up to 8 batteries)
Terminal Bolt Size Terminal Bolt: M8 x 1.25 x 12 mm Long Terminal Bolt:

M8 x 1.25 x 16 mm
Recommended Terminal Torque| 70.8 inch·lbs / 8 N·m
Protection Rating| IP67
Certification| MSDS, UN38.3, FCC, CE, PSE, and UKCA

Operation Parameters

Charge Voltage 14.4V
Maximum Continuous Charge Current 100A
Maximum Continuous Discharge Current 100A
Peak Discharge Current 245A@30s
Charge Temperature Range -4°F to 131°F (-20°C to 55°C)
Discharge Temperature Range -4°F to 140°F (-20°C to 60°C)
Storage Temperature Range -13°F to 149°F (-25°C to 65°C)
Operation Relative Humidity 10% to 95%

Maintenance & Storage

Inspection
Please perform regular inspections following the steps below:

  • Examine the external appearance of the battery. The housing and terminals of the battery shall be clean, dry, and free of corrosion.
  • Check battery cables and connections. Replace any damaged cables and tighten any loose connections.

In certain application scenarios, corrosion may occur around the terminals. Corrosion can cause increased resistance and poor contact. It is recommended to regularly apply insulation grease to each terminal. Insulation grease can form a moisture-resistant seal and protect the terminals from corrosion.

Cleaning
Please clean the battery at regular intervals following the steps below:

  • Disconnect the battery from the system.
  • Clear the leaves and debris from the battery.
  • Clean the battery with a soft, lint-free cloth. The cloth can be dampened with water or mild soap and water if the battery is extremely dirty.
  • Dry the battery with a soft, lint-free cloth.
  • Keep the area around the battery clean.
  • Reconnect the battery to the system.

Checking Voltage
Please check the battery voltage periodically to assess battery health. If the battery is unable to be activated with a charge/discharge current greater than 1A or the battery is activated with a open circuit voltage below 10V, the battery may have been severely overcharged due to self-discharge or parasitic loads. Please stop using the battery until the fault can be corrected and the battery can be charged.

Storage
Please follow the tips below to ensure that the battery emerges from storage in a good condition:

  • Charge the battery to 30% to 50% SOC.
  • Disconnect the battery from the system.
  • Store the battery in a well-ventilated, dry, clean area with temperatures between -13°F (-25°C) and 149°F (65°C).
  • Do not expose the battery to direct sunlight, moisture, or precipitation.
  • Handle the battery carefully to avoid sharp impacts or extreme pressure on the battery housing.
  • Charge the battery at least once every 3~6 months to prevent it from overdischarge.
  • Fully charge the battery when it is taken out of storage.

Important Safety Instructions

Renogy accepts no liability for any damage caused by:

  • Force majeure including fire, typhoon, flood, earthquake, war, and terrorism.
  • Intentional or accidental misuse, abuse, neglect or improper maintenance, and use under abnormal conditions.
  • Improper installation, improper operation, and malfunction of a peripheral device.
  • Contamination with hazardous substances or radiation.
  • Alterations to the product without express written consent from the manufacturer.

General

  • Wear proper protective equipment and use insulated tools during installation and operation. Do not wear jewelry or other metal objects when working on or around the battery.
  • Keep the battery out of the reach of children.
  • Do not dispose of the battery as household waste. Comply with local, state, and federal laws and regulations and use recycling channels as required.
  • In case of fire, put out the fire with a FM-200 or CO2 fire extinguisher.
  • Do not expose the battery to flammable or harsh chemicals or vapors.
  • Clean the battery regularly.
  • It is recommended that all cables should not exceed 10 meters because excessively long cables result in a voltage drop.
  • The cable specifications listed in the quick guide account for critical, less than 3% voltage drop and may not account for all configurations.
  • Do not expose the battery to strong electrostatic fields, strong magnetic fields, or radiation.

Battery Safety

  • Please keep the battery away from water, heat sources, sparks, and hazardous chemicals.
  • Do not puncture, drop, crush, burn, penetrate, shake, strike, or step on the battery.
  • Do not open, dismantle, repair, tamper with, or modify the battery.
  • Do not touch any terminals or connectors.
  • Please make sure any battery charger or charge controller has been disconnected before working on the battery.
  • Do not connect or disconnect terminals from the battery without first disconnecting loads.
  • Do not place tools on top of the battery.
  • Please use suitable handling equipment for safe transportation of the battery.
  • Do not insert foreign objects into the positive and negative terminals of the battery.

Renogy Support
To discuss inaccuracies or omissions in this quick guide or user manual, visit or contact us at:

RENOGY-RBT12100LFP-BT Pro-Series-Smart-Lithium-Iron-Phosphate-Battery-FIG-
\(22\)

To explore more possibilities of solar systems, visit Renogy Learning Center at:

For technical support outside the U.S., visit the local website below:

Battery Recycling

The proper disposal and recycling of batteries are essential for environment protection and circular economy. We encourage correctly disposing of your batteries when they become depleted. You can dispose your used batteries at any of Call2Recycle or Earth911 locations that accepts Renogy rechargeable Lithium-ion and Lead-acid batteries (AGM&GEL).

Enjoy our community’s incentive program when you properly dispose of your batteries. You can earn $20 gift cards to purchase any products on our website by participating. It’s a simple way to be environmentally responsible and be rewarded for recycling.

renogy.com/support

FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  1. Orient or relocate the receiving antenna.
  2. Increase the separation between the equipment and receiver.
  3. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  4. Consult the dealer or an experienced radio/TV technician for help.

FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

IC Warning
This device complies with Industry Canada’s licence-exempt RSS standard(s). Operation is subject to the following two conditions:

  1. this device may not cause interference, and
  2. this device must accept any interference, including interference that may cause undesired operation of the device.

Renogy Empowered

  • Renogy aims to empower people around the world through education and distribution of DIY-friendly renewable energy solutions.
  • We intend to be a driving force for sustainable living and energy independence.
  • In support of this effort, our range of solar products makes it possible for you to minimize your carbon footprint by reducing the need for grid power.

Live Sustainably with Renogy
Did you know? In a given month, a 1 kW solar energy system will…

RENOGY-RBT12100LFP-BT Pro-Series-Smart-Lithium-Iron-Phosphate-Battery-FIG-
\(23\)

Renogy Power PLUS

Renogy Power Plus allows you to stay in the loop with upcoming solar energy innovations, share your experiences with your solar energy journey, and connect with like-minded people who are changing the world in the Renogy Power Plus community.

  • @Renogy Solar
  • @renogyofficial
  • @Renogy

Renogy reserves the right to change the contents of this manual without notice.

RENOGY.COM

FAQ

Q: Can I use a different charger with the Renogy Pro Series Battery?
A: It is recommended to use compatible chargers specified in the user manual to ensure proper charging and battery health.

Q: How often should I perform maintenance on the battery?
A: Regular maintenance checks are recommended as per the guidelines in the user manual. Monitor the battery’s condition periodically for optimal performance.

Q: Is it safe to leave the battery unattended during charging?
A: It is not advisable to leave the battery unattended during charging. Always follow safety precautions and guidelines provided in the user manual.

References