1. BRIEF DESCRIPTION

The EG4 280Ah WallMount AW Conduit Box allows users a simple way to protect cables and connections between battery and inverter from the elements. The conduit box is designed to seamlessly integrate with the 280Ah WallMount AW Battery and the 18kPV Hybrid Inverter.

NOTE: This unit is not compatible with the 280Ah WallMount Indoor battery.

2. PACKING LIST

The items listed below will arrive with the product shipment:

3. CONDUIT BOX KNOCKOUT/HOLE PATTERNS & SCHEMATICS

3.1 EXTERIOR DIMENSIONS

Top View

Front View

3.2 LEFT & RIGHT-SIDE PANEL

Right Panel

Left Panel

3.3 TOP PANEL

Top Panel

4. POWER PRO CONDUIT BOX INSTALLATION

The conduit box is a highly recommended accessory for the battery to retain all the cables inside an enclosure for added protection and safety. The conduit box houses the wires that are running between the inverter and the battery.

Step 1: Identify the four screw locations that attach to the battery on the lower side of the conduit box. (Figure 1). Place the conduit box on top of the battery and use the (4) screws provided with the battery to tighten the conduit box to the battery.

4.1 INSTALLATION WITH A CONDUIT BOX
Attach the conduit box (sold separately) to the top of the WallMount.
Refer to Section 7.1 for the conduit box installation instructions.

CAUTION: ALWAYS MOUNT THE BATTERY IN AN UPRIGHT POSITION!

Mounting Instructions

  1. Place mounting bracket on wall at proper mounting height (top of the bracket a minimum 28.0625 in) from the ground; use a level to make sure the bracket is straight, and mark mounting hole locations. Drill holes to accommodate mounting hardware being used.
    Note: The top of the mounting bracket at 28.0625 in. from the ground makes the battery sit on the ground.

  2. Secure mounting bracket to the wall using the included expansion bolts (concrete/brick walls) or appropriate hardware required for the mounting surface.
    Note: If not mounting into concrete or brick using the included expansion bolts, ensure bolts are mounted into both studs or other supportive material. The battery is 300lb, please ensure full mounting support.

  3. Attach the WallMount battery pack to the mounting bracket. To accomplish this, lift the battery up and hook the flange on the back of the battery into the flange on the front of the mounting bracket. Secure the battery to the mounting bracket with the 4 included side screws.
    Note: The battery is very heavy. Please use the team lift technique to prevent damage to personnel and/or equipment

  4. Attach the conduit box (sold separately) to the top of the WallMount battery using the included hardware.

  5. Finally, properly ground the battery, attaching a grounding conductor to the M6 grounding screw on top of the battery to the Equipment Grounding System.

Steps 1 & 2

Figure 4 – WallMount Installation with Conduit Box Steps 1 & 2

Figure 5 – WallMount Installation with Conduit Box Steps 3, 4 & 5

4.2 WITH EG4 18KPV INVERTER

CAUTION: ALWAYS MOUNT THE BATTERY IN AN UPRIGHT POSITION!

Mounting Instructions with EG4 18kPV (See diagrams on following pages)

Note: If not mounting into concrete or brick using the included expansion bolts, ensure bolts are mounted into both studs or other supportive material. The battery is over 300lb, please ensure full mounting support.

  1. Place mounting bracket on wall at proper mounting height (Min. 28.0625 in.) from the ground; use a level to make sure the bracket is straight, and mark mounting hole locations. Drill holes to accommodate mounting hardware being used.
    Note: The mounting bracket at 28.0625in from the ground makes the battery sit on the ground.

  2. Align the provided X-bracket with the holes on the mounting bracket and secure both to the wall, using the included expansion bolts (concrete/brick walls) or appropriate hardware required for the mounting surface. The X-bracket will be behind the mounting plate, against the wall.

  3. Using the X-bracket as a guide, attach the EG4 18kPV mounting bracket using the appropriate hardware required for the mounting surface.

  4. Attach the WallMount battery pack to the mounting bracket. To accomplish this, lift the battery up and hook the flange on the back of the battery into the flange on the front of the mounting bracket. Secure the battery to the mounting bracket with the 4 included side screws.
    Note: The battery is very heavy. Please use the team lift technique to prevent damage to personnel and/or equipment

  5. Attach the conduit box (sold separately) to the top of the WallMount battery using the included hardware.

  6. Attach the 18kPV to the inverter mounting bracket making sure that the holes of the inverter align with the conduit box and secure to each other with the included hardware.

  7. Finally, properly ground the battery, attaching a grounding conductor to the M6 grounding screw on top of the battery to the Equipment Grounding System.

Figure 6 – WallMount Installation with Conduit Box & 18kPV Steps 1 & 2

Figure 7 – WallMount Installation with Conduit Box & 18kPV Steps 3 & 4

Figure 8 – WallMount Installation with Conduit Box & 18kPV Steps 5 & 6

Final – Front View w/ Dimensions

Figure 9 – WallMount Installation with Conduit Box & 18kPV Final

Notes