Corded Area-Imaging Scanner
Quick Start Guide
HH490-EN-QS-01 Rev A 1/21
Agency Model: HH490
Note: Refer to your User Guide for information about cleaning your
device.
Getting Started
Turn off computer’s power before connecting the scanner, then power up the computer once the scanner is fully connected.
**Power Supply Assembly (if included)
Connecting the Scanner USB
**
**RS232 Serial Port:
**
USB Interface
By scan config barcode below, you can change to different USB type interface.
USB Keyboard
USB HID
USB Serial
RS232 Interface
By scan config barcode below, you can change to RS232 interface.
RS232
Reading Techniques
The view finder projects an aiming dot that should be centered over the bar
code, but it can be positioned in any direction for a good read.
Hold the scanner over the bar code, press the button, and center the aiming
dot on the bar code.
The aiming dot is smaller when the scanner is closer to the code and larger
when it is farther from the code. Hold the scanner close to smaller bar codes,
and farther away from large bar codes to get a proper read.
If the bar code is highly reflective (e.g., laminated), you may need to tilt
the scanner at an angle so the bar code can be scanned.
Standard Product Defaults
The following bar code resets all standard product default set-tings.
Standard Product
Keyboard Country
Scan the appropriate country code that follows to program the keyboard layout
for your country or language. By default, national character replacements are
used for the following characters: # $ @ [ ] | ^ ` { } ~
Refer to the ISO 646 Character Replacements chart in your User Guide to view
the character replacements for each country.
USA (Default)
Denmark
France
Great Britain
Belgium
Finland
Germany/Austria
Italy
Norway
Spain
Switzerland
Note: For a complete list of country codes, see the User Guide for your
product.
Trigger
The following bar codes will allow you to use the scanner in Manual Trigger –
Normal Mode (need to press the button to read) or Presentation mode (the
scanner is activated when it “sees” a bar code).
Manual Trigger – Normal (Default)
Presentation Mode
Streaming Presentation Mode
Suffix
If you want a carriage return after the bar code, scan the Add CR Suffix bar code. To add a tab after the bar code, scan the Add Tab Suffix bar code. Otherwise, scan the Remove Suffix bar code to remove the suffixes.
Add CR Suffix
Remove Suffix
Add Tab Suffix
Remove Suffix
Add Code ID Prefix To All Symbologies (Temporary)
Scan the following bar code if you wish to add a Code ID prefix to all
symbologies at once.
Note: For a complete list of Code IDs, see the User Guide for your product.
Function Code Transmit
When this selection is enabled and function codes are contained within the scanned data, the scanner transmits the function code to the terminal. Charts of these function codes are provided in your User Guide. When the scanner is in key- board wedge mode, the scan code is converted to a key code before it is transmitted.
Enable (Default)
Disable
Data Format Editor Instructions
The following are abbreviated instructions for entering a data format. For
complete instructions refer to your User Guide.
Step 1. Scan the Enter Data Format symbol.
Step2. Primary/Alternate Format: scan 0 for Primary Format
Step 3. Terminal Type: scan 099 for any terminal type
Step 4. Code I.D.: scan 99 for any bar code type
Step 5. Length: scan 9999 for any length bar code.
Step 6. Editor commands: use the Programming Chart that follows.
Step 7. Scan Save to save your entries.
Enter Data Format Save
Clear All Data Formats
Programming Chart
Save
Programming Chart (0-9)
**Programming Chart (A-F)
Save
Discard
Reset
EZConfig for Scanning**
To access additional features for the scanner, use EZConfig for Scanning, an
online configuration software tool, available from our website.
Support
To search our knowledge base for a solution or to log into the Technical
Support portal and report a problem, go to
https://sps.honeywell.com/us/en/support/technical-support.
Documentation
Product documentation is available at
https://sps.honeywell.com.
Limited Warranty
For warranty information, go to
www.honeywellaidc.com and click Support >
Warranties.
Patents
For patent information, see www.hsmpats.com
Disclaimer
Honeywell International Inc. (“HII”) reserves the right to make changes in
specifications and other information contained in this document without prior
notice, and the reader should in all cases consult HII to determine whether
any such changes have been made. The information in this publication does not
represent a commitment on the part of HII.
HII shall not be liable for technical or editorial errors or omissions
contained herein; nor for incidental or consequential damages resulting from
the furnishing, performance, or use of this material. HII disclaims all
responsibility for the selection and use of software and/or hardware to
achieve intended results.
This document contains proprietary information that is protected by copyright.
All rights are reserved. No part of this document may be photocopied,
reproduced, or translated into another language without the prior written
consent of HII. Copyright
© 2019 Honeywell International Inc. All rights reserved.
References
- Industrial Automation | Honeywell
- Productivity products and associated patents | Honeywell
- Safety and Productivity Solutions | Honeywell
- Technical Support | Honeywell LinkedIn Facebook Twitter YouTube
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>