Honeywell SNG-S SERIES Hall-Effect Speed Sensor
GENERAL SPECIFICATIONS
Honeywell’s SNG-S Series Speed Sensors use a magnetically biased Hall-effect integrated circuit (IC) to accurately sense movement of ferrous metal targets. The specially designed IC and a permanent magnet are sealed in rugged, probe- type packages. The IC detects the alteration of the magnet’s flux density when it is approached by ferrous metal. A sensor positioned at the circumference of a revolving gear wheel detects the teeth and spaces, and supplies a digital pulse output with frequency proportional to gear wheel speed. Optimum performance is dependent upon a combination of variables such as target material, geometry and speed, sensor/target gap, and environmental temperature.
ELECTRICAL SPECIFICATIONS
TABLE 1. ELECTRICAL SPECIFICATIONS
CHARACTERISTIC
|
CONDITION/COMMENT
| PARAMETER
SNG-SPRF-002
| SNG-SPRD-002 SNG-SPSC-001 SNG-SPRC-001| SNG-SPRD-003 SNG-
SPRC-002| SNG-SPRD-004 SNG-SPRC-003
Supply voltage| regulated supply and 12 V battery ISO 16750-2| 4.5 V to 24 V
—
| —
8 V to 16 V
| —
4.8 V to 16 V
| —
4.8 V to 24 V
Supply current| —| 20 mA max.| 15 mA
Reverse voltage protection| —
ISO 16750-2
| -24 V
—
| —
-14 Vdc
Over voltage protection| —
ISO 16750-2
| 26.5 V
—
| — 26 V
Short circuit protection| —
ISO 16750-2
| 16 V
—
| — 16 V
Load dump| ISO 16750-2:2012 11 01
(US* = 40 V, UA 13.5 ±0.5 V)
| 5b
—
| | —
—
|
Insulation resistance| ISO 16750-2:2012| >10 MOhm at 500 Vdc
—
| —
—
MECHANICAL SPECIFICATIONS
TABLE 2. MECHANICAL SPECIFICATIONS
CHARACTERISTIC
| PARAMETER
SNG-SPRF-002
| SNG-SPRD-002 SNG-SPSC-001 SNG-SPRC-001| SNG-SPRD-003 SNG-
SPRC-002| SNG-SPRD-004 SNG-SPRC-003
Carrier material| PBT thermoplastic| PBT
Bushing material| SS304| SSTL
O-ring material| 70 durometer fluorocarbon, PTFE coating 17,0 mm ID x 2,0 mm
CS| fluorocarbon, brown 17,0 mm ID x 2,0 mm CS
Housing material| PBT| PBT
Connector: integral mating|
Bosch 928000453
Bosch 1928403966
|
Amp Superseal 1.5
282087
Mounting torque| 8 ±0,5 N m with M6 screw| 20 ±3 N m with M8 screw
O-ring lubrication| mineral oil-based grease
ENVIRONMENTAL SPECIFICATIONS
TABLE 3. ENVIRONMENTAL SPECIFICATIONS
CHARACTERISTIC
|
CONDITION/COMMENT
| PARAMETER
SNG-SPRF-002| ALL OTHER CATALOG LISTINGS
Radiated immunity
| ISO 11452-2: 2004
ISO 11452-2: 2004
IEC 61000-4-3: 2008
ISO 11452-2, 400 MHz to 2.5 GHz
| 10 kHz to MHz, 60 m/V
200 MHz to 2.7 GHz, 100 V/m
800 kHz MHz to 1000 MHz, 3 m/V
—
| —
—
—
100 V/m
Bulk current injection| ISO 11452-4, 1 MHz to 400 MHz| 100 mA
ESD| SAE J1113/13 ISO 10605| ±4 kV contact, ±8 kV air
—
| —
±8 kV contact, ±15 kV air
Conductive transients| ISO 7637-2, for 12 V system
ISO 7637-2, for 12 V system
| TEST PULSE 1, 2a, 2b, 3a, 3b
—
| —
PULSE 1, 2a, 3a, 3b, 5a
Conducted emissions| CISPR 25. 150 kHz to 108 MHz| —| Class 3
Radiated emissions| CISPR 25. 150 kHz to 12.5 GHz| —| Class 3
Thermal cycle| -40°C to 140°C| —| 100 cycles
Humidity
| —
95 %RH at 55°C
| 10 %RH to 90 %RH at -40°C to 85°C,
150 cycles, 600 hr total
—
| —
144 hr, EN/IEC 60068-2-30
Saline dunk| 0°C to 110°C| —| 10 cycles, ISO 16750-4
Salt fog
| 5% salt solution by mass at 35°C and 93% RH for 400 hr, tested to 2000 hr with no ingress in the sensor packaging area
5% salt solution by mass at 35°C
| 5% salt solution by mass at 35°C and 93% RH for 2000 hr
—
|
—
96 hours
Combined temperature and vibration test
| sinusoidal: 25 hr/axis, 3 perpendicular axes
30 g at 60 Hz to 1000 Hz and 15 g at
1000 Hz to 2000 Hz
random: 25 hr/axis, 3 perpendicular axes 30 g at 25 rms Hz to 2000 Hz, -40°C to 125°C
| sinusoidal: 25 hr/axis, 3 perpendicular axes
15 g at 5 Hz to 2000 Hz
random: 25 hr/axis, 3 perpendicular axes
at 25 grms at 10 Hz to 2000 Hz
|
—
—
Vibration| 3 perpendicular axes, 48 hr per axis| —| 29.8 GRMS, 24 Hz to 2000
Hz, MIL-STD-202-214
Degree of protection| IEC 50629
IEC 60529
| IPX6, IPX9K, IPX7
—
| —
IP69K, IP67
Resistance to fluids| —| —| general under-the-hood automotive fluids
Operating temperature| —| -40°C to 150°C| -40°C to 140°C
Storage temperature| —| -55°C to 70°C| -40°C to 140°C
SCHEMATIC DIAGRAMS AND OUTPUT SPECIFICATIONS
CHARACTERISTIC | CONDITION/COMMENT | PARAMETER |
---|---|---|
Signal type | open collector | square wave |
Power on | — | default high and start from initial edge |
Signal polarity | not dependent on target rotation | output low on teeth |
Output signal: high
low
|
—
—
|
VP – 0.5 V
<0.6 V
Load current| output leakage current -10 mA| 10 mA max.
Frequency| —| 0 kHz to 10 kHz
CHARACTERISTIC | CONDITION/COMMENT | PARAMETER |
---|---|---|
Signal type | open collector | square wave |
Output signal: | ||
high | dependent on target geometry and sensor-to- | (VP x (16.5)/(16.5 + RP in |
kOhm) 0.3 V to 2.2 V
low| target orientation| <(((VP-0.4) x 1 k)/(1 k + Rp
| | in kOhm))+0.4
Load current| —| 15 mA
Frequency| —| 0 kHz to 10 kHz
CHARACTERISTIC | CONDITION/COMMENT | PARAMETER |
---|---|---|
Signal type | open collector | square wave |
Output signal: | ||
high | dependent on the |
controller interface
| >VCC – 0.5 V
low| | <0.5 V
Load current| —| 20 mA
Frequency| —| 0 kHz to 10 kHz
CHARACTERISTIC | CONDITION/COMMENT | PARAMETER |
---|---|---|
Signal type | open collector | square wave |
Output signal: high
low
|
dependent on the controller interface
|
(Vp x (16.5)/(16.5+ Rp in
kOhm)0.5 V
<0.5 V
Load current| —| 20 mA
Frequency| —| 0 kHz to 10 kHz
MOUNTING DIMENSIONS
(FOR REFERENCE ONLY: MM/[IN].)
CUSTOMER INTERFACE BORE
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop devices or in any other
application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious
injury.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of defective
materials and faulty workmanship during the applicable warranty period.
Honeywell’s standard product warranty applies unless agreed to otherwise by
Honeywell in writing; please refer to your order acknowledgment or consult
your local sales office for specific warranty details. If warranted goods are
returned to Honeywell during the period of coverage, Honeywell will repair or
replace, at its option, without charge those items that Honeywell, in its sole
discretion, finds defective. The foregoing is buyer’s sole remedy and is in
lieu of all other warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no event shall
Honeywell be liable for consequential, special, or indirect damages.
While Honeywell may provide application assistance personally, through our
literature and the Honeywell web site, it is buyer’s sole responsibility to
determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed
to be accurate and reliable as of this writing. However, Honeywell assumes no
responsibility for its use.
FOR MORE INFORMATION
Honeywell Safety and Productivity Solutions services its customers through a worldwide network of sales offices and distributors. For application assistance, current specifications, pricing or the nearest Authorized Distributor, visit our website or call:
USA/Canada +1 302 613 4491
Latin America +1 305 805 8188
Europe +44 1344 238258
Japan +81 (0) 3-6730-7152
Singapore +65 6355 2828
Greater China +86 4006396841
Honeywell
Advanced Sensing Technologies
830 East Arapaho Road
Richardson, TX 75081
sps.honeywell.com.ast
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>