ACURITE Indoor Temperature & Humidity Sensor Instruction Manual
- June 7, 2024
- Acurite
Table of Contents
Instruction Manual
Indoor Temperature & Humidity Sensor
model 06044
Features & Benefits
FRONT OF SENSOR
1. Indoor Temperature
Arrow icon indicates direction temperature is trending.
2. Wireless Signal Indicator
Flashes when data is being sent to the companion unit.
3. Humidity Level Indicator
Indicates a high, low or ideal indoor humidity level.
4. Indoor Humidity
Arrow icon indicates direction humidity is trending.
5. Channel Indicator
6. Sensor Low Battery Indicator
BACK OF SENSOR
7. A-B-C Button
Press to select A-B-C channel.
8. Integrated Hang Hole
For easy wall mounting.
9. Co/FoButton
For selecting temperature units.
10. RESET Button
Full reset to factory defaults.
11. Battery Compartment
12. Battery Compartment Cover
(not shown)
Questions? Contact Customer Support at 877-221-1252 or visit www.AcuRite.com.
SAVE THIS MANUAL FOR FUTURE REFERENCE.
SETUP
Install or Replace Batteries
AcuRite recommends high-quality alkaline batteries in the sensor for the best
product performance. Heavy duty or rechargeable batteries are not recommended.
1. Slide off the battery compartment cover.
2. Insert 2 x AAA batteries into the battery compartment, as shown. Follow
the polarity (+/-) diagram in the battery compartment.
3. Replace the battery cover.
Set the A-B-C Channel
The A-B-C button is located on the back of the sensor, above the battery
compartment. Press and release to set the channel to A, B, or C (shown on the
sensor display’s channel indicator).
NOTE : If being used with a companion product that has an A-B-C channel,
you must select the same letter choice for both the sensor and the product it
is being paired with in order for the units to synchronize.
PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY
AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.
BATTERY SAFETY: Clean the battery contacts and also those of the device prior
to battery installation. Remove batteries from equipment that is not to be
used for an extended period of time. Follow the polarity (+/-) diagram in the
battery compartment. Promptly remove dead batteries from the device. Dispose
of used
batteries properly. Only batteries of the same or equivalent type as
recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose
of batteries in fire, as batteries may explode or leak. DO NOT mix old and new
batteries or types of batteries (alkaline/standard). DO NOT use rechargeable
batteries. DO NOT recharge non-rechargeable batteries. DO NOT short-circuit
the supply terminals.
Placement for Maximum Accuracy
AcuRite sensors are sensitive to surrounding environmental conditions. Proper placement of the sensor is critical to the accuracy and performance of this product.
Sensor Placement
The sensor is designed for indoor use. Place the sensor in a dry area free of
dirt and dust. The sensor stands upright for tabletop use and is wall-
mountable.
Important Placement Guidelines
• To ensure accurate temperature measurement, place sensor out of direct
sunlight and away from any heat sources.
• Sensor must be within 330 ft (100 m) of companion unit (not included).
• To maximize wireless range, place sensor away from large metallic items,
thick walls, metal surfaces, or other objects that may limit wireless
communication.
• To prevent wireless interference, place sensor at least 3 ft (0.9 m) away
from electronic devices (TV, computer, microwave, radio, etc.).
For more information, visit our Knowledge Base at http://www.AcuRite.com/kbase
Specifications
TEMPERATURE RANGE: | -4°F to 158°F; -20°C to 70°C |
---|---|
HUMIDITY RANGE: | 1% – 99% RH (relative humidity) |
BATTERY REQUIREMENTS: | 2 x AAA alkaline |
WIRELESS RANGE | 330 ft / 100 m depending on home construction materials |
OPERATING FREQUENCY | 433 MHz |
FCC Information
This device complies with part 15 of FCC rules. Operation is subject to the
following two conditions:
1- This device may NOT cause harmful interference, and
2- This device must accept any interference received, including interference
that may cause undesired operation.
WARNING : Changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment.
NOTE : This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
NOTE : The manufacturer is not responsible for any radio or TV
interference caused by unauthorized modifications to this equipment. Such
modifications could void the user authority to operate the equipment.
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference received, including interference
that may cause undesired operation of the device.
Customer Support
AcuRite customer support is committed to providing you with best-in-class
service. For assistance, please have the model number of this product
available and contact us in any of the following ways:
877-221-1252
Visit us at www.AcuRite.com
► Installation Videos
► Instruction Manuals
► Replacement Parts
► Register your Product
► Support User Forum
► Submit Feedback & Ideas
Limited 1 Year Warranty
AcuRite is a wholly-owned subsidiary of Chaney Instrument Company. For purchases of AcuRite products, AcuRite provides the benefits and services set forth herein. For purchases of Chaney products, Chaney provides the benefits and services set forth herein.
We warrant that all products we manufacture under this warranty are of good
material and workmanship and, when properly installed and operated, will be
free of defects for a period of one year from the date of purchase. Any
product which, under normal use and service, is proven to breach the warranty
contained herein within ONE YEAR from the date of sale will, upon examination
by us, and at our sole option, be repaired or replaced by us. Transportation
costs and charges for returned goods shall be paid for by the purchaser. We
hereby disclaim all responsibility for such transportation costs and charges.
This warranty will not be breached, and we will give no credit for products
that have received normal wear and tear not affecting the functionality of the
product, been damaged (including by acts of nature), tampered, abused,
improperly installed, or repaired or altered by others than our authorized
representatives. Remedy for breach of this warranty is limited to repair or
replacement of the defective item(s). If we determine that repair or
replacement is not feasible, we may, at our option, refund the amount of the
original purchase price
THE ABOVE-DESCRIBED WARRANTY IS THE SOLE WARRANTY FOR THE PRODUCTS AND IS
EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. ALL OTHER
WARRANTIES OTHER THAN THE EXPRESS WARRANTY SET FORTH HEREIN ARE HEREBY
EXPRESSLY DISCLAIMED, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTY OF
MERCHANTABILITY AND THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR
We expressly disclaim all liability for special, consequential, or incidental damages, whether arising in tort or by contract from any breach of this warranty. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. We further disclaim liability from personal injury relating to its products to the extent permitted by law. By acceptance of any of our products, the purchaser assumes all liability for the consequences arising from their use or misuse. No person, firm or corporation is authorized to bind us to any other obligation or liability in connection with the sale of our products. Furthermore, no person, firm or corporation is authorized to modify or waive the terms of this warranty unless done in writing and signed by a duly authorized agent of ours.
In no case shall our liability for any claim relating to our products, your
purchase or your use thereof, exceed the original purchase price paid for the
product. Applicability of Policy
This Return, Refund, and Warranty Policy applies only to purchases made in the
United States and Canada. For purchases made in a country other than the
United States or Canada, please consult the policies applicable to the country
in which you made your purchase. Additionally, this Policy applies only to the
original purchaser of our products. We cannot and do not offer any return,
refund, or warranty services if you buy products used or from resale sites
such as eBay or Craigslist.
Governing Law
This Return, Refund, and Warranty Policy are governed by the laws of the
United States and the State of Wisconsin. Any dispute relating to this Policy
shall be brought exclusively in the federal or state courts having
jurisdiction in Walworth County, Wisconsin; and purchaser consents to
jurisdiction within the State of Wisconsin.
Printed in China
06044 INST 030316
©Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copyrights are the property of their respective owners. AcuRite uses patented technology. Visit www.AcuRite.com/patents for details.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>