hugolog HU02 Digital Latchbolt Instruction Manual

June 5, 2024
hugolog

hugolog HU02 Digital Latchbolt

Warning

  • Failure to follow these instructions could result in damage to the product and avoid the factory waranty
  • The accuracy of the door preparation is critical for the proper functioning and security of this product. Misalignment can cause performance degradation and lessening of security.
  • Finish Care: This lockset is designed to provide the highest standard of product quality and performance. Care should be taken to ensure a long-lasting finish. When cleaning is required use a soft, damp cloth. Using lacquer thinner, caustic soaps, abrasive cleaners or polishes could damage the coating and result in tarnishing.

Caution

IMPORTANT: Do not install batteries untill the lock is completely installed on door.

  1. Master PIN Code (4-1 O digit): Default master pin code is K12345678″, please modify it after
    installation. If you forget your master pin code, you can reset your lock back to factory settings.

  2. User PIN Code (4-1 0 digit}: User pin codes can be set up through master pin code. Up to 20
    user pin code can be stored.

  3. Both master and user pin codes don’t support the following combination of numbers.

Parts Illustrations

Item

Battery

| AA al Specifications

AA alkaline battery x4
(Operation voltage: 4.6-6.0V)

| Last up Remarks

to one year

---|---|---
| x4| (10 times open/close per day)

Caution
Master and User pin code have 4-1 O digits, the default master pin code Is [ 12345678]. Please change It prior to programming of the loc:k

Definitions

  • Master Mode
    The master mode could be entered by entering[ **+Master PIN Code+# ] to progam the lock.

  • Master PIN Code:
    The master pin code is used for programming and for feature settings.

  • Passing Mode:
    The lock could be adjusted to passing mode by handle switch. In this mode, pin code and key are not
    needed to unlock the door. Passing mode will be dlsabled after long-pressing any buttons for 2 seconds
    from outside, and will be resumed when the door is unlocked again by Pin code or a key.

  • Fake Pin Code:
    It is the randome numbers that is added before or after the user password. The prevents the user
    password from being exposed.

  • Shutdown Time:
    The lock will shutdown for a default of 3 mins and not allow operation after the wrong code entry
    limit (10 times) has been met. When the unit is in shutdown, the light will flash when you are trying
    to use keypad.

  • Silent Mode:
    The beeper will not make any voice.

  • Status indicators:
    Located on exterior assembly.

  • User PIN code:
    The user pln code operates the lock. Maximum number of user pin codes is 20.

  • Reset button:
    After reset operation, the lock will be restored to factory default settings, all user credentials will be
    deleted. Refer to reset guide.

Factory Default settings

Settings

Master PIN Code

| Factory Default
---|---
Beeper

Wrong Code Entry Limit Shutdown Time

| E12na3b4l5e6d78

3 1 O times

mins

|

Lock Operation

Notes:

  1. Beeps sound only when beeper is enabled.
  2. If the indicators show 3 red lights + 3 beeps, your setting failed. The system will exit master mode. Please try to enter master mode again if you continue your processing.

How to use

Normal mode

  1. Enter the master or user pin code into the keypad, then rotate the lever to open the door. Door will automatically re-lock 7 seconds later.
  2. Insert the backup key and rotate it 1 40°, then rotate the lever to open the door. Door will automatically re-lock 7 seconds later.

Passing mode

  1. Rotate the lever directly to open the door.
    Unlock with Fake PIN code

User can prevent pin code exposure from strangers by entering random digits before or after pin code.

  1. Press any key on the keypad for 2 seconds to lock the door.
    Reset to factory default settings Operations on lock

  2. . Open battery box and find the reset button.

  3. User a sharp thing to press and hold the reset button.

  4. Keep holding the reset button and remove a battetry from battery box then replace it.

  5. Keep holding the reset button for another 3 seconds untill hearing voice guide.