CUSTOM P3 Retail Printer User Manual
- June 7, 2024
- CUSTOM
Table of Contents
P3 Retail Printer
USER MANUAL
P3
CUSTOM S.p.A. Via Berettine 2/B 43010 Fontevivo (PARMA) – Italy Tel. : +39
0521-680111 Fax : +39 0521-610701 http: www.custom.biz
Customer Service Department: www.custom4u.it
© 2020 CUSTOM S.p.A. Italy. All rights reserved. Total or partial
reproduction of this manual in whatever form, whether by printed or electronic
means, is forbidden. While guaranteeing that the information contained in it
has been carefully checked, CUSTOM S.p.A. and other entities utilized in the
realization of this manual bear no responsibility for how the manual is used.
Information regarding any errors found in it or suggestions on how it could be
improved are appreciated. Since products are subject to continuous check and
improvement, CUSTOM S.p.A. reserves the right to make changes in information
containedinthismanualwithoutpriornotiication.
The pre-installed multimedia contents are protected from Copyright CUSTOM
S.p.A. Other company and product names mentioned herein may be trademarks of
their respective companies. Mention of third-party products is for
informational purposes only and constitutes neither an endorsement nor a
recommendation. CUSTOM S.p.A. assumes no responsibility with regard to the
performance or use of these products.
THE IMAGES USED IN THIS MANUAL ARE USED AS AN ILLUSTRATIVE EXAMPLES. THEY
COULDN’T REPRODUCE THE DESCRIBED MODEL FAITHFULLY.
UNLESS OTHERWISE SPECIFIED, THE INFORMATION GIVEN IN THIS MANUAL ARE REFERRED
TO ALL MODELS IN PRODUCTION AT THE ISSUE DATE OF THIS DOCUMENT.
GENERAL INSTRUCTIONS CUSTOM S.p.A. declines all responsibility for accidents
or damage to persons or property occurring as a result of tampering,
structural or functional modiications, unsuitable or incorrect installations,
environments not in keeping with the equipment’s protection degree or with the
required temperature and humidity conditions, failure to carry out maintenance
and periodical inspections and poor repair work.
GENERAL SAFETY INFORMATION Your attention is drawn to the following actions
that could compromise the characteristics of the product: · Read and retain
the instructions which follow. · Follow all indications and instructions given
on the device. · Make sure that the surface on which the device
rests is stable. If it is not, the device could fall, seriously damaging it. ·
Make sure that the device rests on a hard (nonpadded) surface and that there
is suficient ventilation. ·
Donotixindissolublythedeviceoritsaccessoriessuchaspowersuppliesunlessspeciically
provided in this manual. · When positioning the device, make sure cables do
not get damaged. · [Only OEM equipment] The equipment must be installed in a
kiosk or system that provides mechanical,electricalandireprotection. · The
mains power supply must comply with the rules in force in the Country where
you intend to install the equipment. · Make sure that there is an easily-
accessible outlet with a capacity of no less than 10A closely to where the
device is to be installed. · Make sure the power cable provided with the
appliance, or that you intend to use is suitable with the wall socket
available in the system. · Make sure the electrical system that supplies power
to the device is equipped with a ground wire and is protected by a
differential switch. · Before any type of work is done on the machine,
disconnect the power supply. · Use the type of electrical power supply
indicated on the device label. · These devices are intended to be powered by a
separately certiied power module having an SELV, non-energy hazardous output.
(IEC60950-1 second edition). · [Only POS equipment] The energy to the
equipment must be provided by power supply approved by CUSTOM S.p.A. · Take
care the operating temperature range of equipment and its ancillary
components. · Do not block the ventilation openings. · Do not insert objects
inside the device as this could cause short-circuiting or damage components
that could jeopardize printer functioning. · Do not carry out repairs on the
device yourself, except for the normal maintenance operations given in the
user manual. · The equipment must be accessible on these components only to
trained, authorized personnel. · Periodically perform scheduled maintenance on
the device to avoid dirt build-up that could compromise the correct, safe
operation of the unit. · Do not touch the head heating line with bare hands or
metal objects. Do not perform any operation inside the printer immediately
after printing because the head and motor tend to become very hot. · Use
consumables approved by CUSTOM S.p.A.
THE CE MARK AFFIXED TO THE PRODUCT CERTIFY THAT THE PRODUCT SATISFIES THE
BASIC SAFETY REQUIREMENTS.
The device is in conformity with the essential Electromagnetic Compatibility
and Electric Safety requirements laid down in Directives 2014/30/EU and
2014/35/EU inasmuch as it was designed in conformity with the provisions laid
down in the following Standards: · EN 55032 (Limits and methods of measure-
ments of radio disturbance characteristics of Information Technology
Equipment) · EN 55024 (Information Technology Equipment Immunity
characteristics Limits and methods of measurement) · EN 60950-1 (Safety of
information equipment including electrical business equipment)
The device is in conformity with the essential requirements laid down in
Directives 2014/53/EU about devices equipped with intentional radiators The
Declaration of Conformity and other available certiications can be downloaded
from the site www.custom4u.it.
GUIDELINES FOR THE DISPOSAL OF THE PRODUCT
The crossed-out rubbish bin logo means that used electrical and electronic
products shall NOT be mixed with unsorted municipal waste. For more detailed
information about recycling of this product, refer to the instructions of your
country for the disposal of these products. · Do not dispose of this equipment
as miscel-
laneous solid municipal waste, but arrange to have it collected separately. ·
The re-use or correct recycling of the electronic and electrical equipment
(EEE) is important in order to protect the environment and the wellbeing of
humans. · In accordance with European Directive WEEE 2012/19/EU, special
collection points are available to which to deliver waste electrical and
electronic equipment and the equipment can also be handed over to a
distributor at the moment of purchasing a new equivalent type. · The public
administration and producers of electrical and electronic equipment are
involved in facilitating the processes of the re-use and recovery of waste
electrical and electronic equipment through the organisation of collection
activities and the use of appropriate planning arrangements. · Unauthorised
disposal of waste electrical and electronic equipment is punishable by law
with the appropriate penalties.
The format used for this manual improves use of natural resources reducing the quantity of necessary paper to print this copy.
MANUAL
For further information about the use of “PrinterSet” tool refer to the manual
with code 78200000001800
TABLE OF CONTENTS
1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2 DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.1 Box contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11 2.2 Device components: external views . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 2.3
Device components: internal view . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 2.4 Device
label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2.5 Key
functions: power up . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2.6 Key
functions: standby . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 2.7 Status
messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3.1 Wall mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19 3.2 Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. 20 3.3 Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . 21 3.4 Driver and SDK. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . 25
4 OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
4.1 Opening device cover . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 4.2
Switch the device on/off . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 4.3
Loading the paper roll . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
5 CONFIGURATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
5.1 Conigurationbykeys . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 5.2
Conigurationbysoftware . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 5.3 Device
status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 5.4
Communication parameters . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 5.5 Operation
parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6 MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
6.1 Autocutter jam. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
41 6.2 Planning of cleaning operations . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 6.3
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
6.4 Firmware upgrade. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
7
7 SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
7.1 Hardwarespeciications . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 7.2
Characterspeciications . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 7.3
Device dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 7.4
Power supply and power cord dimensions . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . 56 7.5 Set di caratteri
in emulazione CUSTOM/POS . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . 58
8 CONSUMABLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 9 ACCESSORIES . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 63 10 TECHNICAL SERVICE . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . 65
8
1 INTRODUCTION
This document is divided into sections and chapters. Each chapter can be
reached by the index at the beginning of this document. The index can be
reached by the button on each page as shown in the diagram below.
Link to table of contents Notes reference
Numbered title for chapter
Numbered title for paragraph
Information valid for devices
AAAA, BBBB, CCC
Information valid for devices AAAA, BBBB
Information valid for device CCCC
5 CONFIGURATION
5.1 Setup parameters
When the printer is turned on it performs a self-test and reset routine(1)
that checks and initializes the following electronic and mechanical
components. During power-up, if the LF LINE FEED key is held down, the printer
enters the autotest routine and prints out the Setup report. The printer
permits the configuration of default parameters.
AAAA, BBBB When the printer is turned on it performs a self-test and reset
routine that checks and initializes the following electronic and mechanical
components.
CCCC During power-up, if the LF LINE FEED key is held down, the printer enters
the autotest routine and prints out the Setup report. The printer permits the
configuration of default parameters.
Useful information to not compromise
devices operation
Generic information or suggestions for the use
of the devices
Information or suggestions related to
specific operations
ATTENTION: Respect power supply polarity.
NOTES: All the dimensions shown in figures are in millimetres. (1) For the
keys functions refer to the chapter 2.
9
10
2 DESCRIPTION
2.1 Box contents
Remove the device from its carton being careful not to damage the packing
material so that it may be re-used if the device is to be transported in the
future. Make sure that all the components illustrated below are present and
that there are no signs of damage. If there are, contact customer service.
1. Documentation (Short guide) 2. AC power supply 3. Standard AC power cord
or US market AC power cord 4. Device
1
2
3
4
11
2.2 Device components: external views
1. Paper compartment cover opening key 2. Paper out 3. FEED key 4. ON/OFF key 5. RS232 serial port 6. USB port
7. Ethernet port 8. Power supply port 9. Drawer port 10. Status LED 11. Paper compartment cover
1 11
2
3 10
4
5
6
9
7
8
12
2.3 Device components: internal view
1. Platen roller 2. Paper presence sensor 3. Printhead with temperature
sensor 4. Autocutter
1 4 3 2
13
2.4 Device label
PC = Product code (14 digits) SN = Serial number HW = Hardware release
XXXXXXXXXXXXXX R
0000000000000000
PC
SN
HW
14
2.5 Key functions: power up
Hold down
POWER UP
Hold down
print SETUP report
Fast push
Fast push
select TEST TYPE
Logo Test Embedded Font Test: – PC437 only – all code pages Chinese Font Test
Fast push
Fast push
Enter the
skip the
SETUP PROCEDURE SETUP PROCEDURE
Fast push
Fast push
next parameter
perform TEST
Fast push
Fast push
modify selected parameter
next parameter
exit from DEVICE TEST
select TEST TYPE
15
2.6 Key functions: standby
Fast push
STANDBY
Fast push
Advance the paper (preset length)
Printing demo ticket
16
2.7 Status messages
The status LED indicates hardware status of device. Given in the table below
are the various LED signals and the corresponding device status.
STATUS LED –
GREEN
GREEN
COMMUNICATION STATUS
GREEN
UNRECOVERABLE ERROR
OFF ON x 2 x 3 x 4 x 5 x 6 x 7 x 8 x 9
x 11
DESCRIPTION DEVICE OFF DEVICE ON: NO ERROR PRINTHEAD OVERHEATED PAPER END
POWER SUPPLY VOLTAGE INCORRECT RECEPTION ERROR (PARITY, FRAME ERROR, OVERRUN
ERROR) COMMAND NOT RECOGNIZED COMMAND RECEPTION TIME OUT INSPECTION DOOR OPEN
PAPER JAM
AUTOCUTTER ERROR
17
18
3 INSTALLATION
3.1 Wall mounting
The device is equipped with two slots for mounting on pins for vertical
mounting capability of the machine.
Thearrangementisplacedatthebottomofthemachine(seeigurebelow). The dimensions
shown in the image are expressed in millimetres.
56
4 1 4.2
Attach two pins to the wall using the measurements shown on the previous image. Thedimensionsoftheixingpinsareprovidedbelow.Thedimensionsshownintheimageareinmillimetres.
2.5
+1 0
0 -1
Ø 7
0
Ø4 -0.5
2
19
3.2 Connections
Thefollowingigureshowsthepossibleconnectionsforthedevice.WhentheRS232andUSBcommunicationcablesare
connected to the device at the same time, communication takes place via the
USB port.
ETH USB
RS-232
DK 24 Vdc
Correctly insert the power supply connector with the flat side upwards
Ethernet CrossOver standard cable
PC
Ethernet UTP standard cable
(pin-to-pin)
USB standard cable
(optional)
Serial standard
cable
HUB
PC USB device
PC Serial device
Power supply cable
(included)
Drawer
Power supply
20
3.3 Pinout
21
3 4
POWER SUPPLY
Tripolar female connector
1 GND
2 +24 Vdc J9
3 GND
4 Frame GND
Thefollowingigureshowstheconnectorpinoutofpowersupplycable:
Power supply cable
ATTENTION: Respect power supply polarity.
Tripolar male connector
n.c.
+24 V
GND
21 34
USB INTERFACE
Female USB type B connector
1 USB0_VBUS (out) 2 USB0_DN 3 USB0_DP J2 4 GND SH1 SHIELD SH2 SHIELD
21
5
1
9
6
RS232 SERIAL INTERFACE
Female DB9 connector
1 DTR232
2 TXD232 During transmission, takes the values -VRS232 and + VRS232 depending on data
3 RXD232 During reception, takes the values -VRS232 and +VRS232 depending on data
4 n.c.
5 GND
J3
6 DTR232 When +VRS232, device is power on
7 CTS232
8 RTS232 When +VRS232, device is ready to receive data
9 n.c.
SH1 SHIELD
SH2 SHIELD
Given the presence of the RS232 standard, logic value “0” corresponds to the
voltage value +VRS232 (voltage value between +3Vdc and +15Vdc) and logic value
“1” corresponds to the voltage value -VRS232 (voltage value between -3Vdc and
-15Vdc.
DEVICE > PC connection The following picture shows an example of connection
between the device and a personal computer using a 9 pin RS232 serial
connector:
DB9 DB9
1 2 3 4 5 6 7 8 9
DEVICE
DTR232 TXD232 RXD232
GND DTR232 CTS232 RTS232
DCD RXD TXD
GND DSR RTS CTS
1 2 3 4 5 6 7 8 9
PC
When use a serial cable, we recommend the installation of a ferrite core on the power supply cable.
22
ETHERNET INTERFACE
Female RJ45 connector
1
8
1 TX+1 2 +3.3 V 3 TX-1 4 RX+1 5 RX-C 6 RX-1 7 n.c. J4 8 GND 9 LED-LNK 10 GND 11 LED-LAN 12 GND 13 SH1 14 SH2
ThefunctionalityoftwoLEDsarespeciiedinfollowingtables: – For 10Base-T connection:
LED LED-LNK LED-LAN
FUNCTION Link (yellow color): the LED lights up when a connection is active Rx/Tx: (green color): the LED lights up when occurs a data reception or transmission
– For 10/100Base-TX connection:
LED LED-LNK LED-LAN
FUNCTION
TheLEDlight(yellowcolor)onwhenaconnectionisactiveandlasheswhenoccursadatareception
or transmission
The LED light (green color) on when occurs a 100 Mbit connection and off when
occurs a 10 Mbit connection
The device automatically recognizes the type of connection (cross or pin-to-
pin).
The pinout shown in table represents the input signals to component J4 before
the isolation voltage transformer (throughhole pin).
23
61
DRAWER CONNECTOR
Female RJ12 connector
1 GND 2 CASS1 3 IN-CASS J11 4 +24VT 5 CASS2 6 GND
The solenoid of the drawer 1 must be connected from Pin 2 to Pin 4 on the drawer connector. The solenoid of the drawer 2 must be connected from Pin 4 to Pin 5 on the drawer connector.
PIN 2
PIN 4
DRAWER 1 DRAWER 2
PIN 4
PIN 5
DEVICE > CASH DRAWER (optional) connection. Use an optional adapter cable RJ12-Jack to connect the device to a cash drawer. Refer to the picture below for the connector pin signals.
RJ12 JACK JACK
SOL1 +24Vdc SOL2
DEVICE
(-) (+)
(-) (+)
CASH DRAWER
24
3.4 Driver and SDK
The drivers for the following operating system are available in the website
www.custom4u.it:
OPERATING SYSTEM
Windows
Linux
DESCRIPTION
INSTALLATION PROCEDURE
Driver for Windows XP
Driver for Windows VISTA (32/64 bit)
Driver for Windows 7 (32/64 bit) Driver for Windows 8 (32/64 bit) Driver for Windows 8.1 (32/64 bit)
From the START menu, press Run and type-in the path where the SW was saved on
your PC, then click OK. Follow the instructions that appear
on the screen to install the driver.
Driver for Windows 10 (32/64 bit)
Self-installing driver for Virtual COM (32/64 bit) (see paragraph 5.4)
32/64 bit
Followtheinstructiongetbackonthe”Readme.txt”ile.You caninditinthesoftwarepackagedownloadedinadvance.
25
26
4 OPERATION
4.1 Opening device cover
1
Press the opening button of the paper compartment cover.
2
Open the device cover.
27
4.2 Switch the device on/off
1
IN DC 24V 1.5A
Power cord (included)
External power supply (included)
Correctly insertt tthhee power ssuuppppllyy ccoonnnneecctotorr (see paragraphh
34..22))
Connect the power adapter (included) to the device and the mains outlet. Use
the type of electrical power supply indicated on the label.
2
ON/OFF Switch the device on pressing ON/OFF key, the status LED turns on and
the device is ready.
Switch the device off holding down the ON/OFF key.
28
4.3 Loading the paper roll
To change the paper roll proceed as follows. At every paper change, check
inside the device to locate and remove any scraps of paper.
1
Open the device cover (see paragraph 4.1).
2
Place the roll in the paper compartment and pull out the paper for a few
centimetres.
29
3
Close the device cover and wait until the paper is loaded and automatically
cut off.
30
5 CONFIGURATION
5.1 Coniguration by keys
Toentertheconigurationmodeandprintasetupreportwiththeoperatingparametersofthedevice,proceedasfollows.
1
ON/OFF
FEED
KEY
KEY
While pressing theFEED key, switch on the device by pressing the ON/OFF key.
2
PRINTER SETUP
The device prints the report with the settings parameters. Follow the
instruction printed on the paper to proceed with configuration procedure.
31
Thefollowingigureshowsthedevicesetupreport.Theshownvaluesforparametersaresamplevalues;foradetailed description of the device operating parameters see the following paragraphs.
DEVICE NAME AND FIRMWARE MODULES
RELEASE
DEVICE STATUS
DEVICE CONFIGURATION
PARAMETERS
KEYS FUNCTIONS
SCODE:
–
FCODE:
–
LCODE:
–
S/N:
PRINTER SETUP
PRINTER TYPE …………………………
INTERFACE ……………………………………RS232
PROGRAM MEMORY TEST……………..OK
DYNAMIC RAM TEST………………………OK
CUTTER TEST………………………………..OK
HEAD VOLTAGE
[V] = 24.12
HEAD TEMPERATURE [°C] = 22
POWER ON COUNTER
= 6
PAPER PRINTED
[cm] = 60
CUT COUNTER
= 13
RS232 Baud Rate ……………………… : RS232 Parity …………………………….. : RS232 Handshaking ………………….. : Busy Condition ………………………….. : USB Address Number ………………… : USB Class ………………………………… : Print Mode ………………………………… : Autofeed …………………………………… : Code Table [num] ………………………. : Chars / inch ………………………………. : Font Type………………………………….. : Speed / Quality………………………….. : PaperEnd Buffer Clear ……………….. : PowerFail WakeUp Mode……………. : Print Density……………………………… :
115200 bps None Hardware RxFull 0 Printer Normal CR Disabled 0 A=15 B=20 cpi International High speed Disabled Always ON 0%
[ LF ] enter Printer setup [ ON/OFF ] skip setup
32
5.2 Coniguration by software
The setup parameters can be set by using the “PrinterSet” software tool
available on www.custom4u.it. For a detailed description of the device
operating parameters see the following paragraphs.
Toconigurethedevicebysoftware,proceedasfollows.
1
CCoonnnneecctt tthhee ddeevviiccee ttoo aa PPCC ddiirreeccttllyy ((sseeee
ppaarraaggrraapphh 43..52)),, wwiitthhoouutt uussiinngg HHUUBB
ddeevviicceess..
2
Start “PrinterSet” software tool.
3
LOAD
SAVE
PORT
From Device From File
Click on LOAD > FROM DEVICE and select the device connected to the PC.
Click on LOAD > From file and select a .psc file on your PC
Drag and drop a .psc file
33
4
LOAD
SAVE
PORT
SETUP FONTS UPGRADE
H. reflect V. reflect
Click on SETUP to access the operating parameteres of the device to be configured.
5
AD
SAVE
PORT
EXTRA
rs>
s>
s>
Disabled Enabled Enabled Disabled Enabled 0 Disabled
Make the desired changes to the device operating parameters.
Activation of the Bluetooth® module or WiFi on the device. If the “Wireless” parameter is set to ON (active) do not connect any communication cable to the device.
6
LOAD
SAVE
PORT
SETUP
Info
To Device
To File
Enabled Enabled Disabled Disabled Enabled 2 Disabled
Click on SAVE > TO DEVICE to make the changes made effective.
Activation of the Bluetooth® module or WiFi on the device. If the “Wireless” parameter is set to ON (active) do not connect any communication cable to the device.
ATTENTION: During saving, it is strongly discouraged to disconnect the
communication cable or to remove the power supply of the PC or the device.
34
5.3 Device status
Thedeviceoperatingstatusisindicatedintheconigurationprint- outinwhich,nexttothenameofthecomponentsdisplayed, the following information is given.
PRINTER TYPE INTERFACE PROGRAM MEMORY TEST DYNAMIC RAM TEST CUTTER TEST HEAD VOLTAGE HEAD TEMPERATURE POWER ON COUNTER PAPER PRINTED CUT COUNTER
device model interface present OK appears if functioning and NOT OK if faulty OK appears if functioning and NOT OK if faulty OK appears if functioning and NOT OK if faulty voltage of the head temperature of the head number of power- ups made centimetres of paper printed number of cuts made
35
5.4 Communication parameters
Thedeviceallowstheconigurationoftheparameterslistedinthefollowingtable. The
parameters marked with the symbol D are the default values.
Settings remain active even after the device has been turned off and they are
stored in non-volatile memory.
RS232 BAUD RATE
Communication speed of the serial interface:
9600 19200 38400
57600 115200 D
Parameter valid only with serial interface.
RS232 PARITY
Bit for the parity control of the serial interface:
None D = parity bit omitted Even = even value for parity bit Odd = odd value
for parity bit
Parameter valid only with serial interface.
RS232 HANDSHAKING
Handshaking:
Xon/Xoff = software handshaking Hardware D = hardware handshaking (CTS/RTS)
Parameter valid only with serial interface.
BUSY CONDITION
Activation mode for the Busy signal:
OffLine/ RxFull = Busy signal is activated when the device is both in OffLine status and
the buffer is full
RxFull D =
Busy signal is activated when the buffer is full
Parameter valid only with serial interface.
USB ADDRESS NUMBER
NumericaladdresscodefortheunivocalidentiicationoftheUSBdevice(incaseofmore than a USB device connected with the same PC):
0 D
2
4
1
3
5
6
8
7
9
USB CLASS
USBcommunicationclassdeinition.
Printer D =
setting the printer function
Virtual COM = setting the USB port as a serial port
36
DHCP CLIENT
HOST NAME IP ADDRESS SUBNET MASK DEFAULT GATEWAY TCP PORT MAC ADDRESS
Setting of the DHCP protocol:
Disabled D = protocol disabled
Enabled =
protocol enabled
Thisparameterisnotprintedonsetupreportanditismodiiableonlyduringsetupprocedure by software (see paragraph 5.2).
Identiicationnameofthedevice.
Thisparameterisnotprintedonsetupreportanditismodiiableonlyduringsetupprocedure
by software (see paragraph 5.2).
IP address of the device.
Thisparameterisnotprintedonsetupreportanditismodiiableonlyduringsetupprocedure
by software (see paragraph 5.2).
Thisparameteridentiiesthelocalnetworkaddress.
Thisparameterisnotprintedonsetupreportanditismodiiableonlyduringsetupprocedure
by software (see paragraph 5.2).
ThisparameteridentiiesthegatewayIPaddressusedtosendapplicationstotheexternal
network.
Thisparameterisnotprintedonsetupreportanditismodiiableonlyduringsetupprocedure
by software (see paragraph 5.2).
This parameter sets the TCP port number.
Thisparameterisnotprintedonsetupreportanditismodiiableonlyduringsetupprocedure
by software (see paragraph 5.2).
Thisisthenumber,providedbytheconstructor,thatidentiiesthedevice;thisnumber is
univocal.
Thisparameterisnotmodiiablebysetup.
37
5.5 Operation parameters
Thedeviceallowstheconigurationoftheparameterslistedinthefollowingtable. The
parameters marked with the symbol D are the default values.
Settings remain active even after the device has been turned off and they are
stored in non-volatile memory.
PRINT MODE AUTOFEED CHARS / INCH
FONT TYPE
CODE TABLE SPEED / QUALITY
PAPEREND BUFFER CLEAR
POWERFAIL WAKEUP MODE
Printing mode:
Normal D = enables printing in normal writing way Reverse = enables printing
rotated 180 degrees
Setting of the Carriage Return character:
CR disabled D = Carriage Return disabled CR enabled = Carriage Return enabled
Font selection:
A = 11 cpi, B = 15 cpi A = 15 cpi, B = 20 cpi D
CPI = Characters Per Inch
Setting of the font type:
International D Chinese GB18030 Korean CP949
= enables the use of the 256 characters font tables = enables the use of the chinese extended font GB18030 = enables the use of the korean font CP949
Identiiernumberofthecharactercodetabletouse.
See paragraph 7.5tolearnaboutthecharactertablescorrespondingtotheidentiication
numbers set with this parameter.
Setting of printing speed and printing quality:
High Quality Normal High Speed D
Cleaning mode of data in receive buffer, if the printing is stopped due to
lack of paper:
Disabled D = Data remain in the receive buffer. When the paper runs out, the
device keeps the remaining data in receive buffer and prints the remaining
portion of ticket after that the new paper is loaded.
Enabled = When the paper runs out, all data in the receive buffer are deleted.
Setting of the after power failure state:
Always OFF Always ON D LAST PWR State
= the device stays off until the ON/OFF key is pushed = the device restarts = the device reverts to its state (on or off) before the power failure
38
PRINT DENSITY
Adjusting the printing density:
-25% -12%
0 D +12%
+25%
Theprintqualityisstronglyinluencedbythetypeofchemicaltreatmentandthetypeof
storage to which the thermal paper has been subjected, as well as by the
weight of the
same. It may therefore necessary to act on this parameter to obtain the
desired print quality.
39
40
6 MAINTENANCE
6.1 Autocutter jam
1
Disconnect the power supply cable and open the device cover (see paragraph
4.1).
2
Remove the autocutter cover making it move as shown in the figure.
41
3
Rotate the gear in the direction with no resistance until the autocutter does
not return to its inital position.
4
Assemble the autocutter cover.
42
5
IInnsseerrtt tthhee ppaappeerr rroollll ((sseeee ppaarraaggrraapphh 44..33))..
6
Turn on the device (see paragraph 4.2) and verify the proper functioning of
the device.
43
6.2 Planning of cleaning operations
The regular cleaning of the device keeps the print quality and extends its
life. The following table shows the recommended planning for the cleaning
operations. If you use the device in dusty environments, you must reduce
intervals between cleaning operations.
Forspeciicprocedures,seeparagraph 6.3.
EVERY PAPER CHANGE Printhead Platen roller EVERY 5 PAPER CHANGES Autocutter Paper path Sensor EVERY 6 MONTHS OR AS NEEDED Case
Use isopropyl alcohol Use isopropyl alcohol
Use compressed air Use compressed air or tweezers
Use compressed air
Use compressed air or a soft cloth
44
6.3 Cleaning
For periodic cleaning of the device, see instructions below.
Sensore
Paper path
1
1
Disconnect the power supply cable and open the device cover (see paragraph
4.1).
2
Disconnect the power supply cable and open the device cover (see paragraph
4.1).
2
ATTENTION: Do not use alcohol, solvents, or hard brushes. Do not let water or other liquids get inside the machine. To remove paper scraps, use tweezers or compressed air.
ON
Alcohol, solvent
Clean the device sensor by using compressed air.
ATTENTION: Do not use alcohol, solvents, or hard brushes. Do not let water or other liquids get inside the machine. To remove paper scraps, use tweezers or compressed air.
ON
Alcohol, solvent
Clean the area involved in the passage of paper by using compressed air.
45
Printhead
1
Platen roller
1
DDiissccoonnnneecctt tthhee ppoowweerr ssuuppppllyy ccaabbllee aanndd ooppeenn
tthhee ddeevviiccee ccoovveerr ((sseeee ppaarraaggrraapphh 44..11))..
2
ISOPROPYL ALCOHOL
Disconnect the power supply cable and open the device cover (see paragraph
4.1).
2 ISOPROPYL ALCOHOL
ATTENZIONE: Non utilizzare solventi o spazzole dure. Assicurarsi che acqua o
altri liquidi non penetrino all’interno del dispositivo. Per rimuovere i
residui di stampa, utilizzare delle pinzette o aria compressa.
ON
Clean the printhead by using a non-abrasive cloth moistened with isopropyl.
46
ATTENTION: Do not use solvents, or hard brushes. Do not let water or other
liquids get inside the machine. To remove paper scraps, use tweezers or
compressed air.
ON
Clean the platen roller by using a non-abrasive cloth moistened with
isopropyl.
Autocutter
1
Case
1
Disconnect the power supply cable and remopoevne the
daeuvtoicceutcteorvecorsve(sre(esepeapraagraragprahp8h.16).1).
2
Disconnect the power supply cable.
2
ATTENTION: Do not use alcohol, solvents, or hard brushes. Do not let water or other liquids get inside the machine. To remove paper scraps, use tweezers or compressed air.
ON
Alcohol, solvent
Clean the autocutter by using compressed air.
ATTENTION: Do not use alcohol, solvents, or hard brushes. Do not let water or other liquids get inside the machine.
ON
Alcohol, solvent
To clean the device, use compressed air or a soft cloth.
47
6.4 Firmware upgrade
Firmware upgrade can be performed by using the “PrinterSet” software tool
available on www.custom4u.it. Toupgradeirmware,proceedasfollows:
1
Login to the website www.custom4u.it, type in the product code of the device
and download the latest fiirmware release available.
2
Connect the device to a PC directly (see paragraph 3.21), without using HUB
devices.
3
Start the “PrinterSet” software tool.
48
4
LOAD
From Device From File
SAVE
PORT
EXTRA
HELP
Select a configuration file as follows: Click on LOAD > From device and select
a device connected with the PC
Click on LOAD > From file and select a .psc file on your PC Drag and drop a
.psc file
Click on LOAD > FROM DEVICE and select the device connected to the PC.
5
LOAD
SFEroTmUDPevice
From File
FONTS UPGRADE
SAVE
PORT
EXTRA
HELP
To perform an upgrade select a file as follows:
For firmware upgrade, click on OPEN and select a.psw or .pfw file on your PC
For module upgrade, click on OPEN and select a.mod file on your PC
Click on UPGRADE and follow the instructions shown on the screen.
ATTENTION: During saving, it is strongly discouraged to disconnect the
communication cable or to remove the power supply of the PC or the device.
49
50
7 SPECIFICATIONS
7.1 Hardware speciications
GENERAL Sensors Emulations
Printing driver
INTERFACES USB port RS232 serial port Ethernet port MEMORIES Receive buffer
Flash memory RAM memory Graphic memory PRINTER Resolution Printing method
Head temperature, paper presence, cover open CUSTOM/POS Windows XP
VISTA (32/64 bit) Windows 7 (32/64 bit) Windows 8 (32/64 bit) Windows 8.1
(32/64 bit) Windows 10 (32/64 bit) Self-installing driver for Virtual COM
(32/64 bit)
Linux
12 Mbit/s from 9600 bps to 115200 bps
10 Mbit/s, 100 Mbit/s
8 kB 1 MB internal + 4 MB external
256 kB internal 2 logos (403 x 608 dots)
203 dpi (8 dot/mm) Thermal,ixedhead
51
Head life (1) Abrasion resistance (2) Pulse durability
Printing method Printing format Character font
Printable barcodes Printing speed (1) (3) PAPER Type of paper Paper width
Paper weight Paper thickness Minimum ticket length External roll diameter
Internal roll core diameter Core thickness Paper end Core type
150 km (with recommended paper) 100 M (12.5% duty cycle) Normal, 90°, 180°,
270°
Height/Width from 1 to 8, bold, reverse, underlined, italic 54 character code
tables (see paragraph 7.5),
extended chinese GB18030-2000, korean PC949 Codabar, Code 32, Code 39, Code
93, Code 128, EAN-8, EAN-13, ITF, UPC-A, UPC-E, Data Matrix, PDF417, QRCode
200 mm/s
Thermal rolls, heat-sensitive side on outside of roll 80 mm
from 60 g/m2 to 90 g/m2 from63mto140m 50 mm max. 80 mm 12 mm (+ 1 mm) 2 mm (+
1 mm)
Not attached to roll core Cardboard or plastic
52
AUTOCUTTER Paper cut Estimated life (1) DEVICES ELECTRICAL SPECIFICATIONS Power supply Typical consumption (3) Standby consumption POWER SUPPLY ELECTRICAL SPECIFICATIONS code 963GE020000041 Power supply voltage Frequency Output Power ENVIRONMENTAL CONDITIONS Operating temperature Relative humidity (RH) Storage temperature Storage relative humidity (RH)
Partial cut 1000000 cuts
24 Vdc ± 10% 1.5 A
0.04 A
from 100 Vac to 240 Vac from 47 Hz to 63 Hz 24 V, 2.5 A 60 W
from 0°C to +50°C from 10% to 85% (w/o condensation)
from -20 °C to +70 °C from 10% to 95% (w/o condensation)
NOTES: (1) : Respecting the regular schedule of cleaning for the device
components. (2) : Damages caused by scratches, ESD and electromigration are
excluded. (3) : Referred to a standard CUSTOM receipt (L = 10 cm, Density =
12.5% dots on).
53
7.2 Character speciications
Character set Character density Number of columns Chars / second Lines / second Characters (L x H mm)-Normal
11 cpi 35
2100 60
2.25 x 3
3 15 cpi
49 2940
60 1.625 x 3
20 cpi 64
3840 60
1.25 x 3
NOTE: Theoretical values.
54
7.3 Device dimensions
Length
190 mm
Height
135.5 mm
Width
142 mm
Weight
1100 g
Allthedimensionsshowninfollowingigureareinmillimetresandreferredtodeviceswithcoversclosedandwithoutpaper roll.
135.5
134
5 6
142
41
4,2 190
55
7.4 Power supply and power cord dimensions
The following table shows the dimensions of the power supply and the power cord included with the device.
POWER CORD code 26100000000311 Length POWER SUPPLY code 963GE020000041 Length Height Width
2000 mm
116 mm 33 mm 52.5 mm
Allthedimensionsshowninfollowingiguresareinmillimetres. POWER CORD code
26100000000311
2000
56
52.5
33
POWER SUPPLY code 963GE020000041 116
AC INLET DC OUTPUT WIRE
50 1200
n.c. 31
2
GND
+24V
57
7.5 Set di caratteri in emulazione CUSTOM/POS
The device has 3 fonts of varying width (11, 15 and 20 cpi) which may be
related one of the coding tables provided on the device.
To know the coding tables actually present on the device, you need to print
the font test (see paragraph 2.5).
You can set font and coding table by using the commands (see the commands
manual of the device) or using the “Code Table” and the “Chars/Inch”
parameters during the setup procedure (see paragraph 5.5).
The following is the full list of coding tables that can be installed on the device.
Coding table
0
PC437 – U.S.A., Standard Europe
1
Katakana
2
PC850 – Multilingual
3
PC860 – Portuguese
4
PC863 – Canadian/French
5
PC865 – Nordic
6
VISCII – Vietnamese Standard Code
11
PC851 – Greek
12
PC853 – Turkish
13
PC857 – Turkish
14
PC737 – Greek
15
ISO8859-7 – Greek
16
WPC1252 – Scandinavian
17
PC866 – Cyrillic 2
18
PC852 – Latin 2
19
PC858 per simbolo Euro in posizione 0xD5
20
KU42 – Thai
21
TIS11 – Thai
26
TIS18 – Thai
30
TCVN_3 – Vietnamese
31
TCVN_3 – Vietnamese
32
PC720 – Arabic
on request on request
on request
on request on request on request on request on request
58
33
WPC775 – Baltic Rim
34
PC855 – Cyrillic
35
PC861 – Icelandic
36
PC862 – Hebrew
37
PC864 – Arabic
38
PC869 – Greek
39
ISO8859-2 – Latin 2
40
ISO8859-15 – Latin 9
41
PC1098 – Farsi
42
PC1118 – Lithuanian
43
PC1119 – Lithuanian
44
PC1125 – Ukrainian
45
WPC1250 – Latin 2
46
WPC1251 – Cyrillic
47
WPC1253 – Greek
48
WPC1254 – Turkish
49
WPC1255 – Hebrew
50
WPC1256 – Arabic
51
WPC1257 – Baltic Rim
52
WPC1258 – Vietnamese
53
KZ1048 – Kazakh
255
Space page
Coding table
on request on request on request on request on request on request on request
on request
59
60
8 CONSUMABLES
The following table shows the list of available consumables for device.
67300000000398 THERMAL PAPER ROLL weight = 55 g/m2 width = 80 mm external Ø =
80 mm core Ø = 13 mm
61
62
9 ACCESSORIES
The following table shows the list of available accessories for device.
963GE020000041 POWER SUPPLY (fortechnicalspeciications,seeparagraph 7.1)
26100000000311 POWER CORD SCHUKO PLUG length = 2 m (see paragraph 7.4)
63
64
10 TECHNICAL SERVICE
In case of failure, contact the technical service accessing the website
www.custom4u.it and using the support tools on the
homepage.Itisadvisabletokeeptheidentiicationdataoftheproductathand. The
product code, the serial number and the hardware release number can be found
on the product label (see paragraph 2.4).
Theirmwarereleasenumber(SCODE)canbefound: · on the setup report (see paragraph
5.1) · connecting the device to a PC and starting the “PrinterSet” tool (see
paragraph 5.2)
65
66
Code : 0576200M000102 Rev.1.10
CUSTOM S.p.A.
World Headquarters Via Berettine, 2/B – 43010 Fontevivo, Parma ITALY Tel. +39
0521 680111 – Fax +39 0521 610701 info@custom.biz – www.custom.biz All rights
reserved
www.custom.biz