HEATIT Z-TRM3 Thermostat User Guide
- June 7, 2024
- HEATIT
Table of Contents
HEATIT Z-TRM3 Thermostat User Guide
INTRODUCTION
Heatit Z-TRM3 is an electronic thermostat for electrical floor heating, designed to be mounted in a standard flush box. The thermostat has a built-in Z-Wave chip that can be connected with Home Automation systems. Heatit Z-TRM3 is equipped with a single pole relay and fits into System 55 frames. The thermostat can withstand a load of max 16A /3600W at 230V. The thermostat may be used for water based heating if the thermostat is linked with the Heatit Z-Water.
NB! If the sensor mode is changed to A or AF mode then a room sensor compensation process will start, which limits maximum power output to 75%. The thermostat adapts to the environment within a few days. No internal sensor calibration should be performed during the first few days.
INSTALLATION
Use e.g. a small slotted screwdriver. Start by carefully removing the front
cover by pushing the release springs. The front cover and the frame may now be
removed. Connect the wires to the thermostat terminals: Use 1,5mm² or 2,5mm²
according to load.
HEATING (N) Heating cable connection (Neutral)
N Power connection (Neutral) 230V
L Power connection (Live) 230V
HEATING (L) Heating cable connection
FLOOR SENSOR NTC type (10, 12, 15, 33 or 47kΩ). Standard 10kΩ.
EXTERNAL SENSOR NTC type (10, 12, 15, 33 or 47kΩ). Standard 10kΩ.
Next, position the thermostat and fasten it onto the wall mounting box using
2-4 screws. Position the frame, then position and carefully press the front
cover until it snaps in place. Check that the front cover has snapped in place
properly on both left and right side. The front cover should now be firmly
fixed on all sides. To be able to to read the Power Metering, the load needs
to be connected to both heating L + N.
ADD/REMOVE
- Press Center (confirm) for 10 seconds. The display will show OFF.
- Press Right (down) 5 times till you see Con in the display.
- Now start the add/remove device process in your home automation software.
- Start adding/removing mode by pressing Center (confirm) for approximately 2 seconds. Adding/removing mode is indicated in the display by rotating LED segments in the display until the timeout occurs after 90 seconds, or if the module has been added/removed in the network. Confirmation will show Inc/EcL in the display. Leave programming mode by choosing ESC in the menu. Your thermostat is now ready for use with default settings.
TECHNICAL DATA
Protocol | Z-Wave – 868,4MHz |
---|---|
Chip | Z-Wave 500 chip |
Rated voltage | 230V 50/60Hz |
Max load | 3600W (resistive load) 750W self-limiting heating cable |
Max current | 16A |
Power consumption | <2,0W |
Ambient temperature | 0°C to 40° (during operation) |
Temperature range | 5°C to 40°C |
Hysteresis | 0,3°C to 3,0°C (default 0,5°C) |
Compatible with NTC | |
sensors with values | 10, 12, 15, 22, 33 og 47 kΩ @ 25°C |
IP Code | IP 21 |
Approvals | Z-Wave Plus, CE, EN 60730-1 EN 60730-2-9 EMC 2014/30/EU RoHS |
2011/65/EU LVD 2014/35/EU
Approved for use in bathrooms.
Heatit Controls AB can not be held liable for typographical errors, other errors or omittances in our information. Product specifications may change without further notice. All electrical installations must be carried out by a licensed electrician. The product must be installed in accordance with national building codes and our installers manual.
Heatit Controls AB l Läkarvägen 4, 454 31 BRASTAD, SWEDEN
Phone: +47 61 18 77 77 l post@heatit.com –
www.heatit.com