Product Specifications:

  • Fixture Type: Outdoor Light Fixture

  • Power Supply: Transformer rated maximum of 300 watts at 15
    volts

  • Distance from Pool/Spa/Fountain: Not intended within 10 feet [3
    meters]

  • Wiring Requirement: UL Listed wire connectors suitable for the
    application

Product Usage Instructions:

Installation Instructions:

  1. Ensure power is turned OFF before installation or
    servicing.

  2. Avoid installing within 10 feet of a pool, spa, or
    fountain.

  3. Use a power supply (transformer) rated maximum of 300 watts at
    15 volts.

  4. Bury Underground Low Energy Cable no more than 6 inches in
    order to connect to the main low voltage cable.

  5. Make wiring connections with suitable UL Listed wire
    connectors.

  6. Position wire connectors within 6 inches from a building
    structure, luminaire, or fitting.

  7. For additional low voltage cable lengths, contact
    1-813978-3700.

Installation Steps:

  1. Dig Hole: Dig a hole in the ground with
    approximately 3 inches of space surrounding the PVC tube for pea
    gravel or sand.

  2. Wire Connection: Pass the fixture wire through
    the PVC tube. Place the fixture body into the PVC tube. Strip both
    leads from the fixture supply cable and the main supply cable.
    Using UL listed wire connectors, connect the leads.

  3. Fill Pea Gravel or Sand: Install the PVC tube
    with fixture in the hole and fill the hole with pea gravel or
    sand.

Frequently Asked Questions (FAQ):

Q: Can I use a power supply exceeding 300 watts?

A: No, it is recommended to use a power supply rated maximum of
300 watts at 15 volts as exceeding this may damage the fixture.

Q: How deep should I bury the Underground Low Energy

Cable?

A: The cable should not be buried over 6 inches in order to
connect to the main low voltage cable.

Q: What should I do if I need additional low voltage cable

lengths?

A: Please contact 1-813978-3700 for assistance with obtaining
additional lengths of low voltage cable.

“`

INSTALLATION INSTRUCTIONS
VOLT® LOW VOLTAGE LANDSCAPE LIGHTING VOLT® Well Light ITEM: VWL-7127
1-813-978-3700 · Mon-Fri 8am-8pm · Sat- Sun 10am – 6pm (EST)

INSTALLATION INSTRUCTIONS
VOLT® Well Light – VWL-7127 & AWL-5013
! IMPORTANT: PLEASE READ BEFORE INSTALLATION
This fixture is intended for installation in accordance with local codes and the National Electric Code (NEC). Failure to adhere to these codes and instructions may result in serious injury, property damage and void the warranty.
These instructions do not intend to cover all variations in installation, operation maintenance or mounting situation.
1.Make sure that the power is turned OFF before installing or servicing this fixture.
2.Warning: this fixture is not intended to be installed within 10 feet [3 meters] of a pool, spa or fountain.
3.This fixture is intended to be used only with a power supply (transformer) rated maximum of 300 watts (25 AMPS) at 15 volts.
4.Underground Low Energy Cable must not be buried over 6″ (15.2 cm) in order to connect to the main low voltage cable.
5.Wiring connections must be made with UL Listed wire connectors that is suitable for the application.
6.Position the wire connector so that it is located within 6 inches (15.2 cm) from a building structure, a luminaire, or fitting.
7.If additional lengths of low voltage cable is required, please call 1-813978-3700.
! IMPORTANT SAFETY INSTRUCTIONS
LIGHTED LAMP IS HOT!
WARNING ­ To reduce the risk of FIRE OR INJURY TO PERSONS. 1.Turn off/unplug and allow to cool before reducing lamp. 2.Lamp gets HOT quickly! 3.Do not touch the hot lens, guard or cowl. 4.Keep lamp away from materials that may burn. 5.Do not touch lamp at any time. 6.Use a soft cloth. 7.Oil from skin may damage lamp. 8.Do not operate the fixture with a damaged or missing lens or shield. SAVE THESE INSTRUCTIONS
813.978.3700 · customersupport@voltlighting.com · www.voltlighting.com
2

PACKAGE CONTENTS
A. (1) Fixture Body B. (1) PVC tube

PRODUCT DIMENSIONS

0.75″

2.17″

2.11″

1 DIG HOLE
PVC Tube
3″

Ground 3″

Dig a hole in the ground with approximately 3″ of space surrounding the PVC tube for pea gravel or sand.

3″ Hole Soil
813.978.3700 · customersupport@voltlighting.com · www.voltlighting.com 3

INSTALLATION INSTRUCTIONS
VOLT® Well Light – VWL-7127 & AWL-5013

2 WIRE CONNECTION
Fixture Body PVC Tube
Soil

Pass the fixture wire through the PVC tube. Place the fixture body into the PVC tube.
Strip both leads from the fixture supply cable and the main supply cable. Using two UL listed wire connectors (sold separately), connect the leads from the fixture supply cable to the main supply cable.

Fixture Supply Cable
Wire Connector Main Supply Cable

3 FILL PEA GRAVEL OR SAND

Pea Gravel or Sand

PVC Tube with Fixture

Install the PVC tube with fixture in the hole and fill hole with pea gravel or sand.

Soil