KENT Crystal Star Water Purifier with Display of Minerals and Purity Instruction Manual
- June 7, 2024
- Kent
Table of Contents
- KENT TECHNOLOGY – A Breakthrough in Water Purification*
- Salient Features of KENT Crystal Star Mineral RO™ Water Purifier
- Items in the Box
- Important Instructions
- Reverse Osmosis Process
- UV Process
- Auto-flushing System
- Water Flow Diagram
- Electrical Circuit Diagram
- Crystal Star Operations
- Computer Controlled Operation
- Automatic Operation
- Installation Instructions
- TDS Adjustment*
- Starting-up the Purifier
- Maintenance
- Important Safety Instructions
- Warning
- Technical Specifications
- Testing Information
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
KENT Crystal Star Water Purifier with Display of Minerals and Purity
Instruction Manual
Welcome to Kent
Dear Customer
At the outset, allow us to thank you for your trust in KENT water purifier. We take pride in our reputation for product quality and industry proven performance. We are certain that your decision to own KENT Crystal Star Mineral ROTM Water Purifier will go a long way towards keeping you and your family in good health. We are confident that you will be satisfied with its performance and that it will serve your need for safer and cleaner drinking water without any compromise.
This guide will help you in getting the best out of your water purifier.
Please go through this booklet to familiarise yourself with its operation and
maintenance.
You can look forward to years of trouble-free service. In case you need any further information, contact your nearest KENT dealer or branch.
Best Wishes,
KENT RO SYSTEMS LTD
KENT TECHNOLOGY – A Breakthrough in Water Purification*
Presenting the KENT Crystal Star Mineral RO™ Smart RO Water Purifier. It uses futuristic and state-of-the-art technology to provide purer and healthier drinking water.
At the heart of the KENT Crystal Star Mineral RO™ Water Purifier is a Reverse Osmosis membrane having capillaries as small as 0.0001 microns, which reduce dissolved impurities (salts and heavy metals) and convert hard water to sweet and pure drinking water. With a patented mineral retention system, the KENT Crystal Star Mineral RO™ Water Purifier allows the user to control the Total Dissolved Solids (TDS) level in the purified water.
KENT is pleased to introduce Zero Water Wastage TechnologyTM that recirculates rejected water to overhead tank with its own pump to make it a Zero Water Wastage RO. This unique technology helps you make water pure, without wasting any water while retaining essential minerals.
Salient Features of KENT Crystal Star Mineral RO™ Water Purifier
- Water purifier with UV disinfection in tank for absolute purification
- Zero Water Wastage**
- Purification by RO + UV + UF + TDS Control + UV in tank makes water pure
- Real time monitoring and display of purity on a digital screen
- Suitable for purification of brackish/ tap water/ municipal corporation water supply
- Wall mounted design, best suited for Indianhomes and offices
- Fully automatic operation, with auto-on/off function
- Computer controlled operation for enhanced purity and long life
- RO Membrane fused inside membrane housing to prevent tampering
- Vertically mounted SMPS for protection from water
- Use of push-fit fittings for leakage and maintenance free performance
- An aesthetically appealing design
- ABS construction for corrosion free use
- Inbuilt Auto-flushing system
- 11L storage tank with water level indicator
- High purification capacity of 20 L/hr.
Items in the Box
- KENT Crystal Star Mineral RO™ Water Purifier : 1 N
- 3-Way Connector : 1 N
- S.S. Ball Valve : 1 N
- Food Grade Pipe (White) 0.952 cm : 2.5 Meters
- Food Grade Pipe (White) 0.952 cm : 20 Meters
- Bulk Head Union : 1 N
- Fixing Clips : 25 N
- Tie Wire 4 inch : 4 N
- Union Connector : 1 N
- Screws & Plastic Inserts : 2 N each
- Sticker Center Drill : 1 N.
- Warranty Card : 1 N
Important Instructions
-
Avoid exposure to direct sunlight and installation in damp areas.
-
Make sure that the temperature of water entering the purifier is within 10°C-40°C.
-
The rejected water can be re-circulated to overhead tank for Zero Water Wastage.
-
The maximum distance between the water source and the purifier should not be more than 3 meters.
-
Avoid sharp bends in the pipe. Do not bend or block the reject water pipe.
-
Do not confine the purifier in a cabinet.
-
In case of not using the purifier for more than two days, kindly switch off the power supply and drain the storage tank.
-
To keep the storage tank clean, it should be drained once in 15 days.
-
Use Genuine KENT Spares for optimum performance.
-
Do not try to service the purifier on your own. Instead, call service technician for help.
Reverse Osmosis Process
The Reverse Osmosis process, also known as hyper filtration, is the finest filtration process known till date. The process ensures the reduction of particles as small as ions from a solution. Reverse Osmosis uses a semi- permeable membrane to reduce salts from potable / brackish water. In Reverse Osmosis, water pressure applied to the concentrated side forces the process of osmosis into reverse. Under enough pressure, treated water is “squeezed” through the membrane from the concentrated side to the diluted side. Salts dissolved in water as charged ions are repelled by the RO membrane. The rejected impurities on the concentrated side of the membrane are washed away in a stream of waste water, and thus do not get accumulated as in a traditional filter.
UV Process
The UV light has shor ter wavelength (higher energy) than the visible light. It is called ultra-violet because it is just beyond the violet light in the light spectrum. Technically, the ultra-violet light is defined to be any wavelength of light, which is shor ter than 400 nanometer.
UV rays, which penetrate into the micro-organisms, are absorbed by the DNA of the pathogen in the water. The DNA is altered in such a way that the pathogen cannot reproduce. Thus, they are essentially killed and cannot cause infection. This process of DNA modification is called inactivation.
Note: The purified water stored in the tank is disinfected using UV LED, which automatically switches on for 30 minutes in a two hour cycle.
Auto-flushing System
The purpose of the Auto-flushing system is to help prevent scaling or fouling of the RO membrane by providing a rapid rinse which washes away impurities from the membrane’s surface and keeps the membrane clean. It offers following benefits.
- Lowers rejected water outflow
- Improves “TDS” rejection rate i.e increases RO membrane efficiency
- Extends life of RO membrane
Water Flow Diagram
S NO | SPARE PART CODE | ITEM DESCRIPTION |
---|---|---|
1 | 20035 | LOW PRESSURE SWITCH |
2 | 20010 | SEDIMENT FILTER |
3 | 20028 | SOLENOID VALVE |
4 | 20005 | BOOSTER PUMP |
5 | 20009 | ACTIVATED CARBON FILTER |
6 | 20003 | OF FILTER |
7 | 20034 | TDS CONTROL VALVE |
8 | 20529 | RO MEMBRANE |
9 | 20020 | FLOW RESTRICTOR TUBE |
10 | 20541 | UV CHAMBER |
11 | 20441 | TDS SENSOR |
12 | 20442 | FLOW SENSOR |
13 | 20015 | POST CARBON FILTER |
14 | 20058 | NON RETURN VALVE |
15 | 20373 | WATER STORAGE TANK |
16 | 20030 | WATER LEVEL SENSOR |
17 | 20630 | UV LED |
Electrical Circuit Diagram
S NO | SPARE PART CODE | ITEM DESCRIPTION |
---|---|---|
1 | 20630 | UV LED |
2 | 20035 | LOW PRESSURE SWITCH (LPSI |
3 | 20625 | DISPLAY SCREEN ASSEMBLY |
4 | 20442 | FLOW SENSOR |
5 | 20441 | TDS SENSOR |
6 | 20626 | COMPUTER CONTROL BALLAST |
7 | 20028 | SOLENOID VALVE |
8 | 20541 | UV CHAMBER |
9 | 20540 | UV LAMP |
10 | 20030 | WATER LEVEL SENSOR |
11 | 20005 | BOOSTER PUMP |
12 | 20059 | PUMP HEAD |
13 | 20016 | SMPS |
Note: The above specifications are subject to modifications for improvement without notice.
Crystal Star Operations
Screen Explained
- RO Flow Indicator
- Filter Life Indicator
- Power On/Off
- RO Pump On
- Tank Full
- Auto Flushing On
- Mineral Content in Purified Water
- Warning Signs
Normal Running Conditions
Under normal running conditions and without any fault,the users would be greeted with a screen as shown in figure, with Power, Tank Full, Filter Life and Water Quality Indicator On.
Since the tank is full, the RO flow rate would not be displayed.
Emptying of Tank
When water is drawn from the tank, thus emptying it, the water tank sign would turn Off, and instead RO Flow, Purification and Mineral Quality would turn On.
Depending upon the mineral contents in the water, the indicator would display Low, Good or High.
Mineral Content – Low
If the TDS level in the purified water is less than the permissible range, the indicator would be in Yellow zone i.e Low
The warning sign would be displayed as shown in the figure.
Mineral Content – Good
If the TDS level in the purified water is within the permissible range, the indicator would be in Green zone i.e Good.
Mineral Content – High
If the TDS level in the purified water is more the permissible range, the indicator would be in Red zone i.e High
The warning sign would be displayed as shown in the figure.
No Water Input
In case of No Water Input, the warning would be displayed, as shown in the figure.
The water purifier would automatically shut off and will remain of till regular water supply is not restored.
Auto-flushing
What to do if Mineral Content is Low or High? Call Customer Care or Login to App *Mineral Content is displayed based on TDS levels in the purified water
UV Lamp Failure/LED Failure
Filter Replacement
Low RO Flow
Low RO flow warning sign indicates reduced capacity of RO Membrane.
All though the water purifier will continue working till the membrane failure happens, it is recommended to call the KENT Customer Care and ask for Membrane Replacement.
Computer Controlled Operation
To ensure delivery of purer and healthier water, a micro-processor is installed in the purifier that performs the following functions:-
UV Stabilization Delay: To ensure that the UV lamp is pre-heated and is working at its optimum level before it starts disinfecting water, the controller provides a two second delay to the UV lamp when the purifier is switched on. During this period, only the UV lamp is switched on and other electrical devices of the purifier are switched off.
Purification Delay: To ensure that the idle water lying in the internal pipes and in the UV chamber is disinfected before being passed into the storage tank, the system provides a 5 second delay when the purifier is switched on. During this time, the UV lamp kills all micro-organisms that may be in the water inside the UV chamber. After this delay, all other electrical devices such as the booster pump and solenoid valve are switched on to start normal purification process.
Alarm: To ensure delivery of purer water, KENT Crystal Star in-built micro controller controls and senses various vital components and displays their status on the digital interface.
Automatic Operation
- The purifier automatically shuts off when the storage tank is full
- The purifier does not start if the inlet water supply pressure falls below 0.3 kg/cm²
- The purifier automatically restarts when the water level drops below the maximum
- The purifier does not allow any water rejection in absence of electricity/when tank is full.
Installation Instructions
The KENT Crystal Star Mineral RO™ Water Purifier is a product of advanced technology, which ensures safe and clean drinking water. The purifier is easy and convenient to install.
Recommended Site Preparations:
- Single Phase 100-250 V AC, 50-60 Hz. connection not more than 3m away from the point of installation of the purifier
- Raw water supply with ½ inch nipple not more than 3m away
- Space as perthe dimensions of the purifier
- Wall/plane surface for mounting two screws and holding the machine
- The system and installation must comply with state and local laws & regulations.
Specific Instructions:
- KENT Crystal Star Mineral RO™ Water Purifier is a wall mountable purifier. Make sure that it is only mounted on a wall. Avoid installation on wooden and metallic stands
- For optimum performance and minimum inlet pressure required, ensure that the raw water supply tank is at least 10 ft. above the purifier.
Installation Procedure:
Step-1
-
Paste the central drill sticker on a wall at 3.6 Feet to 4.0 Feet from the ground as per your convenience.
-
Ensure that the sticker is pasted straight on the wall, then drill holes as per the space provided on the sticker.
-
Now, insert the puff up with the help of a hammer.
-
Screw in two 10X50 self-taping screws, 5.4 inches (138 mm) apart horizontally.
-
Carefully hang the purifier on the wall with the help of wall-mounting slot holes provided on back side of the purifier.
Note:
- If the wall is not straight or the screws are not properly drilled in an even position, it will damage your purifier.
- Keep the device away from heat or direct sunlight.
Step-2
- First fix the SS ball valve (marked as no. 4) to the 1/4 inch port of the 3-way connecter (marked as no. 2) as shown in figure 2.
- Connect the 3-way connector to the raw water supply (marked as no. 1) as shown in the figure 3. The 3-way connector is fit in line with the raw water supply.
- The other end of the 3-way connector can be connected to a tap (marked as no.3) as shown in figure or can be plugged off if not required.
Step-3
-
another end to the upper push-fit elbow fitting to the left hand side of the purifier labelled as WATER IN, as shown in fig 1.
-
Similarly, connect one end of the white pipe to the lower elbow fitting connector in tank labelled as REJECT WATER and leave the other end in the overhead tank, as shown in fig 2.
Step-4
Before connecting the power supply, it is important that you perform the following functions:
- Open the SS ball valve (Handle parallel to the ball valve) to start the flow of water into the purifier, as shown in the figure.
- Wait for 2-3 minutes to ensure that the filters are soaked in water.
Step-5
- Connect the power supply.
- Installation is complete.
TDS Adjustment*
The unique TDS Controller enables customers to retain the contents of natural minerals in purified water, as per their requirement.
- Turning the screw of the valve anti-clockwise results in an increased mineral content.
- Turning the screw of the valve clockwise results in a decreased mineral content.
Note: We recommend keeping the TDS at the lowest possible level but not below 50mg/l.
Starting-up the Purifier
- Switch on the power supply
- Wait till the storage tank completely fills up**
- Switch off the power supply
- Drain the storage tank by opening the drain plug present at the bottom of the storage tank, so as to remove any dust particles present in the pipes and storage tank
- Close the drain plug and switch on the power supply
- The purifier is ready to use
Maintenance
To ensure that the purifier operates at its best, a routine maintenance must be performed. The frequency of the maintenance will greatly depend upon the raw water quality and consumption of purified water.
-
The storage tank must be drained once in 2 weeks. To do so, switch off the power supply, open the drain plug at the bottom of the tank and allow the water to drain. Then, screw back the plug and switch on the power supply
-
Replace the sediment, activated carbon and post carbon filter when the filter change alarm is audible, or after every 12 months. It is recommended to change the FRT when the filters are replaced
-
Replace the RO membrane once every year
-
Replace the UV Lamp once in a year
-
If you are not going to use the purifier for a long time (in case you are on a holiday, tour or out of home), make sure that you disconnect the power supply, turn off the raw water supply and drain the storage tank.
-
Tested & Certified by TUV-SUD South Asia (P) Ltd.
** Tested or certified flushing time – 24hrs.
The Reverse Osmosis System contains a replaceable treatment component critical for the effective reduction of total dissolved solids and that product water shall be tested periodically to verify that the system is performing properly.
Replacement of spare parts are as under:
-20010 SP Inline Sediment Filter 8″
-20529| SP| RO Membrane
-20009| SP| Inline Carbon Filter 8″
-20015| SP| Post Carbon Filter (Blue)
-20003| SP| Hollow Fibre Membrane
-20020| SP| FRT 300/450
Important Safety Instructions
- If the supply cord is damaged, it must be replaced by the original part in order to avoid hazard.
- Children should be supervised to ensure that they do not play with the appliance
- This appliance is not intended for use by persons (including children) with reduced physical,sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Warning
- Do not operate the UV-C emitter when it is removed from the appliance enclosure.
- Read the maintenance instructions before opening the appliance.
- The appliance must be disconnected from the supply before replacing the UV C emitter.
Technical Specifications
Product
| KENT Crystal Star
---|---
Product Code|
11123
Product Generic Name
| Water Purifier
Product Colour|
White
Applications
| Suitable for Purification of Brackish /
Tap Water / Municipal Water Supply
Purification Production Rate|
Upto 20 L/hr.*
Body Material
| ABS Food Grade Plastic
Mounting|
Wall-mounted
Dimensions (mm)
| 380 (L) x 280 (W) x 535 (H)
Inlet Water Pressure/Temp (Min.)|
0.3 kg / cm2 / 10°C
Inlet Water Pressure/temp (Max.)
| 4 kg / cm2 / 40°C
Min./Max. Operating pH|
6.5-8.0
Filter Cartridge
| Sediment, Carbon Filter, UF and Post Carbon
UV Lamp Wattage|
11 W
UV LED wattage
| 0.7 W
Life of UV Lamp|
5000 hrs. of operation
Net Weight
| 8.40 kg
Storage Capacity|
11 L
Maximum Duty Cycle
| 100 L/day
Membrane Type|
Thin Film Composite RO
Booster Pump Voltage
| 24 V DC
Total Power Consumption|
60 W
Input Power Supply
| Single Phase 100-250 V AC, 50-60 Hz
IP Rating|
IPX1
- Purification capacity tested for raw water having TDS level of 750 ppm at room temperature.
Testing Information
The System has been tested according to IS 10500:2012 (Standards for drinking water as per Bureau of Indian Standards) for reduction of the hazardous substances.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>