VARIA04 Brewing Scale Instruction Manual

October 29, 2023
Varia

VARIA04 Brewing Scale

Product Information

The VARIA04 is a digital weighing scale that can weigh objects up to 3kg with a deviation of 0.3g to 500g: 0.1g, 500g to 1000g: 0.5g, and 1000g to 3000g: 1g. It has a weighing platform, a 4-digit digital LED display, ON/OFF switch, START/STOP switch, UNIT switch, and TARE switch. The maximum count-up time of the timer display is 99 minutes 59 seconds. It is powered by DC 6V 4 x AAA batteries and has an automatic power-off feature after approximately 3 minutes of inactivity to save battery life.

The VARIA04 is manufactured and tested according to the technical standards of the Measurement Act. However, the variance of gravity from region to region may cause detrimental errors.

Product Usage Instructions

  1. Touch the ON/OFF switch to turn on the scale. Place it on a horizontal level surface.
  2. When the power is turned on, all letters and symbols will appear on the scale display. “0’00 / 0.0g” will appear on the display. If anything other than 0.0g appears, press the ON/OFF switch for 2 seconds to turn off the power and turn the scale off. Then try turning it back on.
  3. Make sure that nothing is on the scale when turning it on. When an object is placed on the weighing platform, the weight will be displayed. Make sure the display is showing 0.0g before placing anything on the scale.
  4. Place objects in the center of the weighing platform. The maximum display range is up to 3000g. If anything heavier than 3000g is placed on the scale, “Err” will be displayed.
  5. To measure/tare/weigh items in containers, press the ON/OFF switch to turn on the scale. When the container is placed on the scale, the weight will be displayed. Make sure the display is showing 0.0g before placing anything on the scale. Place objects in the center of the weighing platform. Press the TARE switch, and 0.0g will be displayed. Only the weight of the content in the container will be displayed. If the weight of the container and its contents are heavier than the maximum weight range, “Err” will be displayed. When the container and contents are removed, “–” will be displayed.
  6. To use the timer function, press START STOP to start the timer. Press START STOP once to pause the timer. Press START STOP again to resume the timer. Press START STOP for about 2 seconds to reset the timer to zero.
  7. Remove objects from the weighing platform and press ON/OFF (about 2 seconds) to turn off the scale.
  8. When replacing batteries, remove the battery cover on the back of the product. Remove the old batteries and then place in new batteries of the same brand with + and – facing the correct direction. Replace the battery cover and click it back into place. When the battery runs low while the scale is in use, “Lo” will be displayed. Please replace the batteries immediately.
  9. To clean the scale, use a slightly damp cloth to clean the main body of the product. Use a mild detergent to wipe hard-to-clean areas. Do not use thinners, benzene, gasoline, kerosene, or alcohol to clean the product as it may cause deterioration and/or discoloration.
  10. After reading the instruction manual, store it in a safe place.

Model: VARIA04
Thank you very much for your purchase. For directions on how to use the procuct, please be sure to read the instruction manual. After reading the manual, store it in a safe place.

PRODUCT OVERVIEW

VARIA04-Brewing-Scale-Instruction-
fig-1

Specifications

VARIA04-Brewing-Scale-Instruction-fig-2

Accuracy assurance range

  1. This product is manufactured and tested according to the technical standards of the Measurement Act.
    *Weight range is 0.3g ~ 3000g
  2. When heated objects are placed on the scale the weight may fluctuate (accuracy ± 2g)
  3. The variance of gravity from region to region may cause detrimental errors.

How to use

  1. Touch the ON/OFF switch to turn it on.
    Place the scale on a horizontal level surface. When the power is turned on, all letters and symbols will appear on the scale display. “0’00” / 0.0g” will appear on the display. If anything other than “0.0g” appears, press the “ON/OFF” switch 2 seconds the power and turn the scale off. Then try turning it back on.
  • Please make sure that nothing is on the scale when turning it on. 2. When an object is placed on the weighing platform the weight will be displayed.

  • Make sure the display is showing ”0.0g” before placing anything on the scale.

  • place objects in the center of the weighting platform.

  • The maximum display range is up to 3000g.
    If anything heavier than(3000g) is placed on the scale “Err” will be displayed.

    1. Remove objects from weighing platform and press ”ON/OFF “ (about 2 seconds) to turn off.

How to measure/tare/weigh items in containers

  1. Press the“ON/OFF”switch to turn on
  2. When the container is placed on the scale the weight will be displayed.
  • Make sure the display is showing”0.0g”before placing anything on the scale
  • Place objects in the center of the weighing platform 3. Press the“ TARE”switch and “0.0g”will be displayed 4. Only the weight of the content in the container will be displayed.
  • If the weight of the container and its contents are heavier than the maximum weight range “Err” will be displayed. 5. When the container and contents are removed “—” will be displayed.

Timer function

  1. Press “START STOP” to start the timer.

  2. Press “START STOP” once to pause the timer
    Press “START STOP” again to resume timer.

  3. Press “START STOP” for about 2 seconds will reset the timer to zero.

Maintenance

  1. Please use a slightly damp cloth to clean the main body of the product. Use a mild detergent to wipe hard to clean areas.
  2. Do not use thinners, benzene, gasoline, kerosene or alcohol to clean for this product. It may cause deterioration and/or discoloration..

How to replace the batteries

  1. Remove the battery cover on the back of the product.
  2. Remove the old batteries and then place in the new batteries of the same brand with “+” and “-” facing the correct direction.
  3. Replace the battery cover and click it back into place.
    When the battery runs low while the scale is in use, “Lo” will be displayed. Please replace the batteries immediately.
  • Please follow the rules of your local environmental policy when disposing batteries.

Handling Precautions

  • This is a precisive instrument, please do not drop and avoid strong impact as it may cause the product to malfunction.
  • Place objects to be weighed gently onto the weighing platform, dropping the product may cause malfunctions.
  • When storing the product do not place anything on or load the weighing platform with other objects,It many lead to malfunctions.
  • Please use on a flat stable surface where the product will not slip. unstable surfaces may lead to the proper weight not being displayed or cause the scale to fall.
  • Please do not stick fingers in zopenings. It may cause injuries.
  • Do not place in areas that are subject to high temperatures. High temperatures many cause deterioration of the product surface or cause fires. Please avoid leaving the product near stoves,other heating devices and exposed to direct sunlight.
  • Mobile RF communication devices may affect the measurement of electronic scales. When use it should avoid strong electromagnetic interference, such as near mobile phones, microwave ovens, etc., It may cause malfunctions.
  • Do not use when the product has been heated ,disassembled,modified or immersed in water as this may cause malfunctions the product to malfunction.

Battery Precautions

Please follow the directions below. If batteries are misused it may lead to battery solution leakage or explosions. and may cause product malfunction and injury.

  • Please make sure the polarities(+/-)are facing the correct directions .
  • Please remove old batteries from the product as soon as possible.
  • When the product will not be used for an extended period of time please remove batteries.

Do not short circuit,disassemble,heat or place batteries in fire. It will lead to over heating, battery solution leakage or explosion. Keep batteries out of reach of children If swallowed, consult a physician immediately. If alkaline solution leaks from batteries on to skin or clothes wash thoroughly with clean water. If solution gets in to eyes, wash thoroughly with clean water and consult a physician immediately. When disposing or storing batteries, please insulate batteries with tape or other methods. If they come in con tact with other metals or batteries it may cause fires or explosions.
www.variabrewing.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals