Honeywell AQ3STF SENSOR Sulfur Dioxide (SO2) Gas Sensor User Guide
- June 7, 2024
- Honeywell
Table of Contents
Honeywell AQ3STF SENSOR Sulfur Dioxide (SO2) Gas Sensor User Guide
Sensor Part Number (without board):
ADQ045-H04
Module Part Number (with board):
QAD045-H04
PCBA Part Number: AQ3-BP01
DOCUMENT PURPOSE
This document should be used in conjunction with the AQ3STF Characterization
Note and the Product Safety Datasheet (PSDS 19).
The data provided in this document is based on the assumption that the sensor
is used at 20°C, 50% rH, and 1013 mBar for three months from the date of
sensor manufacture. For guidance on sensor performance outside of these
limits, please refer to the AQ3STF Characterization Note.
Output signal can drift below the lower limit over time. For guidance on the
safe use of the sensor, please refer to the Operating Principles.
FEATURES AND BENEFITS
TECHNICAL SPECIFICATIONS
MEASUREMENT
ELECTRICAL
MECHANICAL
ENVIRONMENTAL
LIFETIME
*Specifications are valid at 20°C, 50% RH, and 1013 mbar using AQ3 low noise board. Performance characteristics outline the performance of sensors supplied within the first 3 months. Output signal can drift below the lower limit over time. Please be aware that sensors’ performance also reflected by circuit board design.
** Linear through the concentration range across the whole operational
environment range.
Product Dimensions
Filter Information
To remove H2S and HCl
Poisoning
Gas sensors are designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapors is avoided, during storage, fitting into instruments, and operation.
When using sensors with printed circuit boards (PCBs), degreasing agents
should be used before the sensor is fitted.
Do not glue directly on or near the sensor as the solvent may cause crazing of
the plastic.
Cross Sensitivity Table
Whilst AQ3 Series gas sensors are designed to be highly specific to the gas
they are intended to measure, they will still respond to some degree to
various other gases.
The table below is not exclusive and other gases not included in the table may
still cause a sensor to react.
IMPORTANT NOTE: The cross sensitivity data shown below does not form part of the product specification and is supplied for guidance only. Values quoted are based on tests conducted on a small number of sensors and any batch may show significant variation. For the most accurate measurements, an instrument should be calibrated using the gas under investigation.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of defective
materials and faulty workmanship during the applicable warranty period.
Honeywell’s standard product warranty applies unless agreed to otherwise by
Honeywell in writing; please refer to your order
acknowledgment or consult your local sales office for specific warranty
details. If warranted goods are returned to Honeywell during the
period of coverage, Honeywell will repair or replace, at its option, without
charge those items that Honeywell, in its sole discretion, finds defective.
The foregoing is buyer’s sole remedy and is in lieu of all other warranties,
expressed or implied, including those of merchantability and fitness for a
particular purpose. In no event shall Honeywell be liable for consequential,
special, or indirect damages.
While Honeywell may provide application assistance personally, through our
literature and the Honeywell web site, it is buyer’s sole
responsibility to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is
believed to be accurate and reliable as of this writing. However, Honeywell
assumes no responsibility for its use.
WARNING MISUSE OF DOCUMENTATION
- The information presented in this product sheet is for reference only. Do not use this document as a product installation guide.
- Complete installation, operation, and maintenance information is provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious injury.
SAFETY NOTE
This sensor is designed to be used in environmental applications. To ensure
that the sensor and/or instrument in which it is used, are operating properly,
it is a requirement that the function of the device is confirmed by exposure
to target gas (bump check) before each
use of the sensor and/or instrument. Failure to carry out such tests may
jeopardize the safety of people and property.
FOR MORE INFORMATION
Honeywell Advanced Sensing Technologies services its customers through a worldwide network of sales offices and distributors. For application assistance, current specifications, pricing or the nearest Authorized Distributor, visit our website or call:
USA/Canada +1 302 613 4491
Latin America +1 305 805 8188
Europe +44 1344 238258
Japan +81 (0) 3-6730-7152
Singapore +65 6355 2828
Greater China +86 4006396841
Honeywell
Advanced Sensing Technologies
830 East Arapaho Road
Richardson, TX 75081
sps.honeywell.com/ast
AQ3STF Datasheet ECN 5062 | 002724-1-EN | 1 | 05/21